[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-49":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":626},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,49,50,2670,[13,35,48,61,74,87,100,112,125,138,150,162,175,187,198,210,222,234,247,259,270,281,292,302,314,326,338,350,362,374,386,398,410,422,434,446,458,470,482,494,506,518,530,542,554,566,578,590,602,614],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},1024163,2,"多选题","对发电机定子绕组的异常过电压，应装设过电压保护的是（）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","水轮发电机；",true,{"key":24,"text":25,"correct":22},"B","100MW及以上水轮发电机；",{"key":27,"text":28,"correct":29},"C","200MW及以上汽轮发电机；",false,{"key":31,"text":32,"correct":29},"D","300MW及以上汽轮发电机。","AB","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},1024164,"发电机转子承受负序电流的能力，以I22为判据，（ ）应装设发电机转子表层过负荷保护。",[39,41,43,45],{"key":20,"text":40,"correct":29},"25MW及以上发电机A≥10的发电机；",{"key":24,"text":42,"correct":22},"50MW及以上发电机A≥10的发电机；",{"key":27,"text":44,"correct":29},"50MW及以上发电机A≤10的发电机；",{"key":31,"text":46,"correct":22},"100MW及以上发电机A 10的发电机。","BD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},1024165,"（）应装设失磁保护。",[52,54,56,58],{"key":20,"text":53,"correct":29},"50MW及以上的发电机；",{"key":24,"text":55,"correct":22},"100MW及以上的发电机；",{"key":27,"text":57,"correct":22},"100MW以下不允许失磁运行的发电机；",{"key":31,"text":59,"correct":29},"30MW及以上的发电机。","BC",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},1024166,"()均应装瓦斯保护。",[65,67,69,71],{"key":20,"text":66,"correct":22},"0.8MVA及以上的油浸式变压器；",{"key":24,"text":68,"correct":29},"1.OMVA及以上的油浸式变压器；",{"key":27,"text":70,"correct":22},"0.4MVA及以上的车间内油浸式变压器；",{"key":31,"text":72,"correct":29},"0.63MVA及以上的车间内油漫式变压器.","AC",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":86,"analysis":34},1024167,"对变压器、引出线、套管及内部的短路故障，按规定，（ )应装纵联差动作为主保护。",[78,80,82,84],{"key":20,"text":79,"correct":22},"电压在10kV以上、容量在10MVA及以上的变压器；",{"key":24,"text":81,"correct":29},"6.3MVA及以上的并列运行变压器；",{"key":27,"text":83,"correct":29},"6.3MVA及以下单独运行的变压器；",{"key":31,"text":85,"correct":22},"对于电压为10kV的重要变压器（当电流速断灵敏系数不符合要求时）。","AD",{"id":88,"libraryId":5,"type":15,"typeLabel":16,"stem":89,"options":90,"answer":99,"analysis":34},1024168,"变压器采用纵联差动保护时，按（）确定保护装置的一次动作电流。",[91,93,95,97],{"key":20,"text":92,"correct":29},"躲过电动机自启动的最大工作电流；",{"key":24,"text":94,"correct":22},"躲过励磁涌流；",{"key":27,"text":96,"correct":22},"躲过外部短路产生的不平衡电流；",{"key":31,"text":98,"correct":22},"躲过电流互感器二次回路断线时的最大负荷电流。","BCD",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":99,"analysis":34},1024169,"对由外部相间短路引起的变压器过电流，按（）规定装设相应保护作为后备保护。",[104,106,108,110],{"key":20,"text":105,"correct":29},"单相式低电压启动过电流用于降压变压器；",{"key":24,"text":107,"correct":22},"复合电压启动的过电流保护，宜用于升压变压器、系统联络变压器、过电流保护不符合要求的降压变压器；",{"key":27,"text":109,"correct":22},"6.3MVA及以上升压变压器，可采用负序电流和单相式低电压启动过电流保护；",{"key":31,"text":111,"correct":22},"当以上选项不能满足灵敏度和选择性要求时，可采用阻抗保护。",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":124,"analysis":34},1024171,"变压器外部相间短躲护’应符合（）规定。",[116,118,120,122],{"key":20,"text":117,"correct":22},"双绕组变压器应装于主电源侧；",{"key":24,"text":119,"correct":22},"三绕组变压器宜装于主电源侧及主负荷侧，若不符合灵敏性要求时，可在各侧装设，根据选择性要求装设方向元件；",{"key":27,"text":121,"correct":29},"三绕组变压器应在高、中压侧装设；",{"key":31,"text":123,"correct":22},"500kV系统联络变压器高、中压侧装设。","ABD",{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":127,"options":128,"answer":137,"analysis":34},1024173,"一次电压为10kV及以下，绕组为三角形一星形接线，低压侧中性点直接接地的变压器，对低压侧单相接地短路应装设下列（)保护之一。",[129,131,133,135],{"key":20,"text":130,"correct":29},"零序电流电压保护；",{"key":24,"text":132,"correct":29},"接于低压侧的三相电流保护；",{"key":27,"text":134,"correct":22},"c.接于低压例中性线上的零序电流保护；",{"key":31,"text":136,"correct":22},"利用髙压侧的三相式过电流保护。","CD",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":99,"analysis":34},1024175,"对330~500kV并联电抗器内部及其引出线的相间和单相接地短路，按规定装设（）。",[142,144,146,148],{"key":20,"text":143,"correct":29},"电流速断保护；",{"key":24,"text":145,"correct":22},"纵联差动保护；",{"key":27,"text":147,"correct":22},"过电流保护；",{"key":31,"text":149,"correct":22},"匝间短路保护。",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":99,"analysis":34},1024177,"下列容量发电机励磁系统顶值电压的倍数应为（）。",[154,156,158,160],{"key":20,"text":155,"correct":29},"50MW及以上汽轮发电机不低于1.8倍；",{"key":24,"text":157,"correct":22},"100MW及以上汽轮发电机不低于1.8倍；",{"key":27,"text":159,"correct":22},"50MW及以上水轮发电机不低于2倍；",{"key":31,"text":161,"correct":22},"其他不低于1. 6倍。",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":174,"analysis":34},1024179,"发电机励磁系统的自动灭磁功能，能在（）工况时可靠地灭磁。",[166,168,170,172],{"key":20,"text":167,"correct":22},"发电机运行在系统中，其磁场电流不超过额定值，定子回路外部或内部短路；",{"key":24,"text":169,"correct":29},"发电机运行中，励磁回路接地故障；",{"key":27,"text":171,"correct":22},"发电机空载；",{"key":31,"text":173,"correct":22},"发电机空载强励。","ACD",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":73,"analysis":34},1024181,"大、中型汽轮发电机和水轮发电机的励磁机励磁回路可采用（ ）灭磁方式的自动灭磁装置。",[179,181,183,185],{"key":20,"text":180,"correct":22},"对电阻放电逆变灭磁；",{"key":24,"text":182,"correct":29},"串联接入灭磁电阻；",{"key":27,"text":184,"correct":22},"非线性电阻灭磁；",{"key":31,"text":186,"correct":29},"对消弧栅放电。",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":33,"analysis":34},1024183,"可装设自同期装置的发电机容量为（）。",[191,192,194,196],{"key":20,"text":21,"correct":22},{"key":24,"text":193,"correct":22},"100MW以上汽轮发电机；",{"key":27,"text":195,"correct":29},"50MW以下汽轮发电机；",{"key":31,"text":197,"correct":29},"100MW以下水轮发电机。",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":137,"analysis":34},1024185,"对由外部相间短路引起的变压器过电流，正确的保护配置是()。",[202,204,206,208],{"key":20,"text":203,"correct":29},"过电流保护宜用于升压变压器；",{"key":24,"text":205,"correct":29},"复合电压（含负序电压及线电压）启动的过电流保护，宜用于降压变压器；",{"key":27,"text":207,"correct":22},"负序电流和单相式低电压启动的过电流保护，可用于6.3MVA及以上升压变压器；",{"key":31,"text":209,"correct":22},"当以上保护不能满足灵敏性和选择性要求时，可采用阻抗保护。",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":33,"analysis":34},1024187,"发电机过负荷保护的反时限部分宜动作于（）两项出口（选择两项可切换的出口)。",[214,216,218,220],{"key":20,"text":215,"correct":22},"解列,",{"key":24,"text":217,"correct":22},"程序跳闸；",{"key":27,"text":219,"correct":29},"减出力；",{"key":31,"text":221,"correct":29},"延时动作于信号，有条件时，可自动减负荷。",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":137,"analysis":34},1024189,"()应装设过负荷保护。",[226,228,230,232],{"key":20,"text":227,"correct":29},"高压电动机（3kV及以上）；",{"key":24,"text":229,"correct":29},"低压I类电动机（380V)；",{"key":27,"text":231,"correct":22},"易过负荷的电动机；",{"key":31,"text":233,"correct":22},"需要防止虏动或自启动时间过长的电动机。",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":246,"analysis":34},1024192,"()应装设低电压保护。",[238,240,242,244],{"key":20,"text":239,"correct":22},"当电源电压短时降低或短时中断后，为保证重要电动机自启动而需要断开的次要电动机；",{"key":24,"text":241,"correct":22},"当电源电压短时降低或短时中断后，不允许或不需要自启动的电动机；",{"key":27,"text":243,"correct":22},"需要自启动，但为保证人身和设备安全，在电源电压长时间消失后，须从电力两中自动断开的电动机；",{"key":31,"text":245,"correct":29},"I类负荷电动机。","ABC",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":174,"analysis":34},1024196,"对63kV及以下油浸式并联电抗器，（）保护配置是正确的。",[251,253,255,257],{"key":20,"text":252,"correct":22},"瓦斯保护；",{"key":24,"text":254,"correct":29},"差动保护及过电流保护；",{"key":27,"text":256,"correct":22},"中性点差流保护（双星形接线）；",{"key":31,"text":258,"correct":22},"温度升高和冷却系统故障保护。",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":124,"analysis":34},1024199,"对单星形接线的330~500kV干式并联电抗器，()保护配置是正确的。",[263,265,267,269],{"key":20,"text":264,"correct":22},"差动保护、过电流保护；",{"key":24,"text":266,"correct":22},"过负荷保护、匝间保护；",{"key":27,"text":268,"correct":29},"过电压保护；",{"key":31,"text":258,"correct":22},{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":73,"analysis":34},1024201,"汽轮发电机失磁保护动作后，如母线电压低于允许值时，保护装置应动作于（）两种出口方式（两种出口方式可切块）。",[274,276,277,279],{"key":20,"text":275,"correct":22},"伴机；",{"key":24,"text":217,"correct":29},{"key":27,"text":278,"correct":22},"解列；",{"key":31,"text":280,"correct":29},"信号、切换厂用电源，有条件时，也可动作于自动减出力。",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":99,"analysis":34},1024204,"汽轮发电机失磁保护动作后，如母线电压未低于允许值时，保护装置应动作于（）。",[285,286,288,290],{"key":20,"text":217,"correct":29},{"key":24,"text":287,"correct":22},"切換厂用电源；",{"key":27,"text":289,"correct":22},"有条件时，也可动作于自动减出力；",{"key":31,"text":291,"correct":22},"信号。",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":137,"analysis":34},1024207,"发电机失步保护应动作于（）。",[296,298,299,301],{"key":20,"text":297,"correct":29},"解列灭磁；",{"key":24,"text":217,"correct":29},{"key":27,"text":300,"correct":22},"失步时间超过整定值或振荡次数超过规定值时动作于解列；",{"key":31,"text":291,"correct":22},{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":33,"analysis":34},1024210,"根据发电机组容量的不同，可选择（）作为发电机外部相间短路故障和作为发电机主保护的后备保护.",[306,308,310,312],{"key":20,"text":307,"correct":22},"过电流保护，或复合电压启动的过电流保护；",{"key":24,"text":309,"correct":22},"低阻抗保护；",{"key":27,"text":311,"correct":29},"负序过电流保护；",{"key":31,"text":313,"correct":29},"过电压保护。",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":60,"analysis":34},1024213,"对发电机定子绕组过负荷保护，正确的说法是（）。",[318,320,322,324],{"key":20,"text":319,"correct":29},"保护装置接三相电流;",{"key":24,"text":321,"correct":22},"保护的定时限部分带时限动作于信号，有条件时，动作于自动减负荷；",{"key":27,"text":323,"correct":22},"保护的反时限部分动作于解列或程序跳闸；",{"key":31,"text":325,"correct":29},"该保护应考虑在灵敏系数和时限方面与其他短路保护配合。",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":47,"analysis":34},1024216,"10OMW及以上A值小于10的发电机的负序电流保护，正确的说法是（）。",[330,332,334,336],{"key":20,"text":331,"correct":29},"定时限部分的动作电流按发电机承受负序电流的能力确定；",{"key":24,"text":333,"correct":22},"定时限部分带时限动作于信号；",{"key":27,"text":335,"correct":29},"反时限部分按躲过发电机长期允许的负序电流值确定；",{"key":31,"text":337,"correct":22},"反时限部分动作于解列或程序跳闸。",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":174,"analysis":34},1024219,"对300MW及以上的发电机励磁绕组过负荷保护，正确的说法是（）。",[342,344,346,348],{"key":20,"text":343,"correct":22},"定时限部分动作电流按照正常运行时最大励磁电流下能可靠返面的条件整定；",{"key":24,"text":345,"correct":29},"定时限部分只动作于信号；",{"key":27,"text":347,"correct":22},"反时限部分动作特性按发电机励磁绕组的过负荷能力确定；",{"key":31,"text":349,"correct":22},"反时限部分动作于解列灭磁，保护应能反映电流变化时励磁绕组的热积累过程。",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":33,"analysis":34},1024222,"对发电机失磁保护，正确的说法是()。",[354,356,358,360],{"key":20,"text":355,"correct":22},"对600MW的发电机可装设双重化的失磁保护；",{"key":24,"text":357,"correct":22},"阻抗元件可按静稳边界或异步边界整定；",{"key":27,"text":359,"correct":29},"母线低电压元件按母线电压的80%整定；",{"key":31,"text":361,"correct":29},"失磁后，母线电压低于允许值时，保护带时限动作于信号。",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":137,"analysis":34},1024224,"控制负荷、动力负荷和直流事故照明共用蓄电池组的电压可采用（）。",[366,368,370,372],{"key":20,"text":367,"correct":29},"24V；",{"key":24,"text":369,"correct":29},"48V；",{"key":27,"text":371,"correct":22},"110V；",{"key":31,"text":373,"correct":22},"220V。",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":73,"analysis":34},1024227,"发电厂和变电所直流系统宜采用的接线型式有（）。",[378,380,382,384],{"key":20,"text":379,"correct":22},"单母线；",{"key":24,"text":381,"correct":29},"双母线；",{"key":27,"text":383,"correct":22},"单母线分段；",{"key":31,"text":385,"correct":29},"双母线单分段。",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":47,"analysis":34},1024230,"下列蓄电池组应进行直流系统短路电流计算的有（ )。",[390,392,394,396],{"key":20,"text":391,"correct":29},"电压为110V的蓄电池组容量大于800Ah；",{"key":24,"text":393,"correct":22},"电压为110V的蓄电池组容量大于1600Ah；",{"key":27,"text":395,"correct":29},"电压为220V的當电池组容量大于1500Ah；",{"key":31,"text":397,"correct":22},"电压为220V的蓄电池组容量大于1600Ah。",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":174,"analysis":34},1024233,"下列宜由两组蓄电池供电的地方是（），",[402,404,406,408],{"key":20,"text":403,"correct":22},"220~500kV变电所；",{"key":24,"text":405,"correct":29},"普通110kV变电所；",{"key":27,"text":407,"correct":22},"发电厂的220kV网络控制室；",{"key":31,"text":409,"correct":22},"发电厂的500kV网络控制室。",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":33,"analysis":34},1024236,"下列直流供电网络宜采取环状供电方式的有（），",[414,416,418,420],{"key":20,"text":415,"correct":22},"发电厂6kV各段开关拒；",{"key":24,"text":417,"correct":22},"发电厂380V各段PC开关拒；",{"key":27,"text":419,"correct":29},"直流主屏至直流分屏；",{"key":31,"text":421,"correct":29},"直流分电屏对直流负荷。",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":137,"analysis":34},1024239,"浮充电装置的输出电流应按()与（）的总和选择。",[426,428,430,432],{"key":20,"text":427,"correct":29},"动力负荷电流之和；",{"key":24,"text":429,"correct":29},"亊故照明负荷电流之和；",{"key":27,"text":431,"correct":22},"经常负荷电流之和；",{"key":31,"text":433,"correct":22},"蓄电池组自放电电流。",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":99,"analysis":34},1024242,"充电设备的选择应满足的条件有（）。",[438,440,442,444],{"key":20,"text":439,"correct":29},"亊故放电电流之和；",{"key":24,"text":441,"correct":22},"大于初充电电流；",{"key":27,"text":443,"correct":22},"大于亊故放电后的补充电流；",{"key":31,"text":445,"correct":22},"大于核对性放电后的充电电流。",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":124,"analysis":34},1024245,"下列蓄电池组布置方式正确的是（）。",[450,452,454,456],{"key":20,"text":451,"correct":22},"蓄电池组宜布置在电气控制楼（主控制楼、网络控制楼、单元控制楼）的底层；",{"key":24,"text":453,"correct":22},"不同—容量、不同电压的酸性蓄电池组可以同室布置；",{"key":27,"text":455,"correct":29},"酸性蓄电池和碱性蓄电池可以同室布置；",{"key":31,"text":457,"correct":22},"蓄电池组布置应避开潮湿和多灰尘的地方。",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":73,"analysis":34},1024248,"蓄电池组的容量宜选择范围正确的是（）。",[462,464,466,468],{"key":20,"text":463,"correct":22},"铅酸蓄电池组容量宜选择在100~3000Ah内；",{"key":24,"text":465,"correct":29},"铅酸蓄电池组容量宜选择在50~2000Ah内；",{"key":27,"text":467,"correct":22},"中倍率镉镍蓄电池组容量宜选择在30~800Ah内；",{"key":31,"text":469,"correct":29},"中倍率镉镍蓄电池组容量宜选择在20~500Ah内。",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":246,"analysis":34},1024251,"发电厂单元控制室装设两组相同电庄、容量且互联的蓄电池组（动力与控制合用），在进行蓄电池组负荷统计计算时，下列说法正确的是（）。",[474,476,478,480],{"key":20,"text":475,"correct":22},"每組蓄电池按照全部控制负荷的100%统计；",{"key":24,"text":477,"correct":22},"每组當电池按照全部直流亊故照明负荷的60%统计；",{"key":27,"text":479,"correct":22},"动力负荷宜平均分配在两组蓄电池上；",{"key":31,"text":481,"correct":29},"应考虑互联増加的负荷统计。",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":47,"analysis":34},1024254,"关于直流配电屏上熔断器熔件和自动开关热脱扣器的额定电流选择，正确的是（）。",[486,488,490,492],{"key":20,"text":487,"correct":29},"对于直流电动机馈线可不考虑电动机启动电流；",{"key":24,"text":489,"correct":22},"对于控制、信号馈线应接短时最大工作电流选择；",{"key":27,"text":491,"correct":29},"对于电磁型操动机构，按额定合闸电流选择，但熔件的熔断时间应大于断路器固有合闸时间；",{"key":31,"text":493,"correct":22},"应保证短路时各级保护设备的选择性，",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":99,"analysis":34},1024256,"下列直流电缆选择方法正确的是（）。",[498,500,502,504],{"key":20,"text":499,"correct":29},"蓄电池组引出线为电缆时，其正极和负极引出线可共用一根电缆；",{"key":24,"text":501,"correct":22},"蓄电池组引出线为电缆时，其正极和负极引出线不应共用一根电缆；",{"key":27,"text":503,"correct":22},"蓄电池组与直流屏之间的联络电缆压降不应大于直流系统标称电压的1%；",{"key":31,"text":505,"correct":22},"由直流屏主环网最远断开点的电压降不应大于直流系统标称电压的5%。",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":99,"analysis":34},1024259,"关于事故停电时间，下列说法正确的是（）。",[510,512,514,516],{"key":20,"text":511,"correct":29},"无人值班变电所3h；",{"key":24,"text":513,"correct":22},"有人值班变电所1h；",{"key":27,"text":515,"correct":22},"与电力系统相连的发电厂1h；",{"key":31,"text":517,"correct":22},"交流不停电电源装里0.5h。",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":124,"analysis":34},1024262,"关于水电厂厂用电配电装置布置，下列描述正确的是()。",[522,524,526,528],{"key":20,"text":523,"correct":22},"低压厂用电配电屏宜靠近负荷中心，尽可能与中央控制室或发电机电压配电装置位于同一髙程；",{"key":24,"text":525,"correct":22},"低压厂用电变压器应靠近相应的低压配电装置，便于用母线引接；",{"key":27,"text":527,"correct":29},"机旁动力配电屏与机组保护、自动装置等二次屏呈一列布置时，宜分隔一块屏位置布置；",{"key":31,"text":529,"correct":22},"高压开关拒室布置宜预留备用柜位置，当采用手车式开关拒时宜留有手车的检修场地。",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":99,"analysis":34},1024265,"对水电厂的I类负荷供电，下列描述正确的是（）。",[534,536,538,540],{"key":20,"text":535,"correct":29},"宜由两个电源供电；",{"key":24,"text":537,"correct":22},"互为备用的I类负荷应从不同分段的主配电展供电；",{"key":27,"text":539,"correct":22},"向I类负荷供电的分配电屏，以双投刀开关与不同分段的主配电屏连接；",{"key":31,"text":541,"correct":22},"装有双电源切换装里的分配电箱宜尽量靠近用电负荷。",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":246,"analysis":34},1024268,"关于水电厂厂用变压器容量选择，下列描述正确的是（）。",[546,548,550,552],{"key":20,"text":547,"correct":22},"装设两台互为备用的厂用电电源变压器时，每台变压器的額定容量应满足所有I、II类负荷或短时满足厂用电最大负荷的需要；",{"key":24,"text":549,"correct":22},"装设三台厂用电电源变压器互为备用或其中一台为明备用时，计及负荷分配不均匀等情况，每台的额定容量宜为厂用电最大负荷的50%~60%；",{"key":27,"text":551,"correct":22},"装设三台以上厂用电电源变压器时，应按其接线的运行方式及所连接的负荷分析确定；",{"key":31,"text":553,"correct":29},"厂用电变压器可采用铎迫A冷时持续输出容量作为额定容量选择的依据。",{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":124,"analysis":34},1024271,"水电厂厂用电的外来电源，取得方式一般是()。",[558,560,562,564],{"key":20,"text":559,"correct":22},"从电厂的髙压例母线引接；",{"key":24,"text":561,"correct":22},"取自自耦变压器的第三绕组；",{"key":27,"text":563,"correct":29},"装设小水轮发电机组或柴油发电机组；",{"key":31,"text":565,"correct":22},"与系统相连的地区电两或保留的施工用变电所。",{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":174,"analysis":34},1024274,"水电厂极少采用小水轮发电机组或柴油发电机组作应急电源，这是因为（）。",[570,572,574,576],{"key":20,"text":571,"correct":22},"布置复杂；",{"key":24,"text":573,"correct":29},"可靠性低；",{"key":27,"text":575,"correct":22},"増加维护工作量；",{"key":31,"text":577,"correct":22},"加大投资、使用率极低。",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":60,"analysis":34},1024277,".水电厂高压厂用电电压一般采用（ ）。",[582,584,586,588],{"key":20,"text":583,"correct":29},"13.8kV；",{"key":24,"text":585,"correct":22},"10.5kV；",{"key":27,"text":587,"correct":22},"6.3kV；",{"key":31,"text":589,"correct":29},"3.15kV。",{"id":591,"libraryId":5,"type":15,"typeLabel":16,"stem":592,"options":593,"answer":73,"analysis":34},1024280,"对担任基、腰荷并采用单元接线的大型水电厂，机组自用变压器的电源宜从（)引接。",[594,596,598,600],{"key":20,"text":595,"correct":22},"电厂髙压厂用电母线；",{"key":24,"text":597,"correct":29},"地区电网；",{"key":27,"text":599,"correct":22},"发电机机端；",{"key":31,"text":601,"correct":29},"电厂高压侧母线。",{"id":603,"libraryId":5,"type":15,"typeLabel":16,"stem":604,"options":605,"answer":137,"analysis":34},1024283,"对水电厂高压厂用电负荷的连接，说法正确的有（）。",[606,608,610,612],{"key":20,"text":607,"correct":29},"有地区电网但为扩大电厂的供电范围，从高压厂用电母线上引出近区用电回路；",{"key":24,"text":609,"correct":29},"有地区电网但为供电可靠，从高压厂用电母线上引出电厂生活用电回路；",{"key":27,"text":611,"correct":22},"厂用电高压电动机、坝区用电电源及低压厂用电变压器宜由高压厂用电母线上直接供电；",{"key":31,"text":613,"correct":22},"同一用途的高压电动机、低压厂用变压器应分别接至不同分段的髙压厂用电母线上，",{"id":615,"libraryId":5,"type":15,"typeLabel":16,"stem":616,"options":617,"answer":124,"analysis":34},1024286,"水电厂厂用电变压器容量的选择和校验要考虑（）。",[618,620,622,624],{"key":20,"text":619,"correct":22},"满足在各种运行方式下，可能出现的最大负荷；",{"key":24,"text":621,"correct":22},"一台厂用电变压器计划检修或故障，其余厂用电变压器应能担负I、n类厂用电负荷或短时担负厂用电最大负荷；",{"key":27,"text":623,"correct":29},"一台厂用电变压器计划检修时，另一台厂用变压器故障，其余厂用电变压器应能担负I、II类厂用电负荷；",{"key":31,"text":625,"correct":22},"保证需要自启动的电动机在故障消除后电动机启动时母线电压不低于规范的要求。",[627,631,634,637,640,643],{"id":628,"name":629,"category":7,"favorite":630},1,"领导干部任职前廉政法规知识测试题",92,{"id":632,"name":633,"category":7,"favorite":628},595,"建筑结构与设备",{"id":635,"name":636,"category":7,"favorite":628},715,"招标采购专业知识与法律法规",{"id":638,"name":639,"category":7,"favorite":628},848,"市政方向-通用基础",{"id":641,"name":642,"category":7,"favorite":8},534,"BIM工程师",{"id":644,"name":642,"category":7,"favorite":8},535]