[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-48":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":631},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,48,50,2670,[13,35,47,60,73,85,98,110,123,136,148,160,172,184,197,210,222,234,246,258,270,282,295,308,320,331,343,355,367,379,391,403,415,427,439,451,463,475,487,499,511,523,535,547,559,571,583,595,607,619],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},1024113,2,"多选题","电力系统振荡时，可能发生误动作的保护是（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","相间电流保护；",true,{"key":24,"text":25,"correct":26},"B","零序电流保护；",false,{"key":28,"text":29,"correct":26},"C","负序电流保护；",{"key":31,"text":32,"correct":22},"D","相间距离保护。","AD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":33,"analysis":34},1024114,"电力线载波纵联保护通道，应按（)原则设计.",[39,41,43,45],{"key":20,"text":40,"correct":22},"当线路上只装设一套载波纵联保护时，载波保护宜采用完全独立的载波通道；",{"key":24,"text":42,"correct":26},"线路上只装设一套载波纵联保护时，载波保护宜与通信复用一个通道；",{"key":28,"text":44,"correct":26},"线路上配置二套载波纵联保护时，二套载波保护宜与通信分别复用通道；",{"key":31,"text":46,"correct":22},"线路上配置二套载波纵联保护时，一套载波保护使用完全独立的载波通道，另一套载波保护可与通信复用一个通道。",{"id":48,"libraryId":5,"type":15,"typeLabel":16,"stem":49,"options":50,"answer":59,"analysis":34},1024115,"330~500kV线路主保护下列配置要求中正确的是()。",[51,53,55,57],{"key":20,"text":52,"correct":22},"设置两套完整、独立的全线速动主保护；",{"key":24,"text":54,"correct":22},"两套主保护的交流电流、电压回路和直流电源相互独立（双母线接线，两套保护可合用交流电压回路）；",{"key":28,"text":56,"correct":26},"两套主保护共用一套远方信号传输设备；",{"key":31,"text":58,"correct":22},"每套主保护应具有独立选相功能。","ABD",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":72,"analysis":34},1024116,"330~500kV线路后备保护下列配置要求中’正确的是（ ）。",[64,66,68,70],{"key":20,"text":65,"correct":22},"采用近后备方式；",{"key":24,"text":67,"correct":26},"后备保护只反应线路的接地故障,",{"key":28,"text":69,"correct":22},"为快速切除中长线路出口故障，在保护配置中宜有专门反今近端故障的快速辅助保护；",{"key":31,"text":71,"correct":22},"当330~500kV配里的双重化主保护都具有完善的后备保护功能时，可不再设后备保护，只要其中一套主保护无后备，则应再设一套完整的独立的后备保护。","ACD",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":33,"analysis":34},1024117,"220kV双母线接线配置的母线保护，动作行为正确的是（）；",[77,79,81,83],{"key":20,"text":78,"correct":22},"母线发生各种相间及接地故障时动作；",{"key":24,"text":80,"correct":26},"母线上的一回220kV线路发生三相短路，母线保护动作；",{"key":28,"text":82,"correct":26},"母线上的一台变压器内部发生单相接地短路，母线保护动作；",{"key":31,"text":84,"correct":22},"双母线同时故障及先后故障时，母线保护动作。",{"id":86,"libraryId":5,"type":15,"typeLabel":16,"stem":87,"options":88,"answer":97,"analysis":34},1024118,"断路器失灵保护必须同时具备()条件，方可启动。",[89,91,93,95],{"key":20,"text":90,"correct":26},"线路保护动作；",{"key":24,"text":92,"correct":22},"故障线路或设备的保护能瞬时复归的出口继电器动作后不返回；",{"key":28,"text":94,"correct":22},"断路器未断开的判别元件，可采用能够瞬时复归的相电流元件；",{"key":31,"text":96,"correct":26},"变压器保护动作。","BC",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":33,"analysis":34},1024119,"断路器失灵保护动作时间，（）整定原则是正确的。",[102,104,106,108],{"key":20,"text":103,"correct":22},"对于一个半断路器接线，应瞬时再次动作于本嶄路器跳用，经一时限动作于断开其他相邻断路器；",{"key":24,"text":105,"correct":26},"对于一个半断路器接线，应瞬时动作于断开其他相邻断路器；",{"key":28,"text":107,"correct":26},"对双母线（或分段单母线）接线，以无时跟动作于断开与拒动断路器相关的母联或分段断路器；",{"key":31,"text":109,"correct":22},"对双母线（或分段单母线〉接线，可仅经一时限动作于断开与拒动断路器连接在同一母线上的所有有源支路的断路器。",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":122,"analysis":34},1024120,"并列运行的发电厂或电力系统之间，具有两条联系的线路或三条联系不紧密的线路，可采用（）重合闸方式。",[114,116,118,120],{"key":20,"text":115,"correct":22},"同步检定和无电压检定的三相重合闸方式；",{"key":24,"text":117,"correct":26},"不检同期的三相重合闸方式；",{"key":28,"text":119,"correct":22},"并列运行双回线路，也可采用栓查另一回线路有电流的自动重合闸方式；",{"key":31,"text":121,"correct":26},"解列重合闸方式，即将一侧电源解列，另一侧装设线路无电压检定的重合闸方式。","AC",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":135,"analysis":34},1024121,"220~500kV电网的线路启动重合闸的方式有().",[127,129,131,133],{"key":20,"text":128,"correct":26},"母线保护动作启动；",{"key":24,"text":130,"correct":22},"线路保护动作启动；",{"key":28,"text":132,"correct":26},"变压器保护动作启动；",{"key":31,"text":134,"correct":22},"断路器位直不对应启动.","BD",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":33,"analysis":34},1024122,"为限制电压严重降低和防止系统电压崩溃，应采取（）措施。",[140,142,144,146],{"key":20,"text":141,"correct":22},"根据无功功率和电压水平的分析结果在系统中配里低电压减载装里；",{"key":24,"text":143,"correct":26},"投入并联电抗器；",{"key":28,"text":145,"correct":26},"切除电容补偿装置；",{"key":31,"text":147,"correct":22},"必要时设罝自动限制电压降低的控制装里，作用于増发无功功率或减少无功功率的需求",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":72,"analysis":34},1024123,"在系统由于事故扰动引起频率降低时，应采取()措施。",[152,154,156,158],{"key":20,"text":153,"correct":22},"有条件时，首先将处于抽水状态的當能机组切除或改发电运行，将调相运行机组改为发电运行，自动启动水电机組和燃气轮机组等；",{"key":24,"text":155,"correct":26},"投入补偿电容装里；",{"key":28,"text":157,"correct":22},"自动低频减负荷或集辛切负荷；",{"key":31,"text":159,"correct":22},"在系统的适当地点设置低頻解列装置，",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":72,"analysis":34},1024124,"为防止电力系统暂态稳定破^，应采取的措施是（）。",[164,166,168,170],{"key":20,"text":165,"correct":22},"对功率过剩地区采用发电机快速减出力，切除部分发电机、投入电气制动等；",{"key":24,"text":167,"correct":26},"将调相运行的机组改发电运行；",{"key":28,"text":169,"correct":22},"对功率缺额地区采用发电机快速加出力、切除部分负荷；",{"key":31,"text":171,"correct":22},"在预定地点将系统解列。",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":122,"analysis":34},1024125,"在电力系统出现失步状态时，应采用失步解列装置，下列解列地点的选择原则中正确的是（）。",[176,178,180,182],{"key":20,"text":177,"correct":22},"送端孤立的大型发电厂，在失步时应优先切除部分机组，以利其他机组再同步；",{"key":24,"text":179,"correct":26},"地区.电网与主系统的联络线；",{"key":28,"text":181,"correct":22},"解列后的两側系统，各自可以同步运行；",{"key":31,"text":183,"correct":26},"有2个及以上联,、通道中选择一个通道进行解列。",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":196,"analysis":34},1024126,"对300MW及以上汽轮发电机，发电机的（ ）动作于停机时，宜采用程序跳闸的方式。",[188,190,192,194],{"key":20,"text":189,"correct":22},"定子绕组过负荷保护及负序电流过负荷保护；",{"key":24,"text":191,"correct":22},"过励磁保护；",{"key":28,"text":193,"correct":22},"失磁保护；",{"key":31,"text":195,"correct":26},"低阻抗保护。","ABC",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":209,"analysis":34},1024127,"电力系统故障动态记录的主要任务是（）。",[201,203,205,207],{"key":20,"text":202,"correct":22},"记录系统大扰动如短路故障、系统振荡、频率崩溃、电压崩溃等发生后的各有关系统电参量的变化过程；",{"key":24,"text":204,"correct":22},"记录系统大扰动变化过程中继电保护及安全自动装置的动作行为；",{"key":28,"text":206,"correct":26},"记录正常运行时发电机的电流和电压；",{"key":31,"text":208,"correct":26},"记录正常运行时变压器的电流和电压。","AB",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":72,"analysis":34},1024128,"自动投入装置应符合的要求有（）。",[214,216,218,220],{"key":20,"text":215,"correct":22},"应保证在工作电源或设备断开后，才投入备用电源或设备；",{"key":24,"text":217,"correct":26},"应保证工作电源或设备完好的情况下，才投入备用电源；",{"key":28,"text":219,"correct":22},"工作电源或设备上的电压，不论因任何原因消失时，除有闭锁信号外，自动趴装置均应动作；",{"key":31,"text":221,"correct":22},"自动投入装置应保证只动作一次。",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":196,"analysis":34},1024129,"在我国对各类双断路器接线方式的线路， 一般按（)原则装设保护。",[226,228,230,232],{"key":20,"text":227,"correct":22},"线路保护宜按线路为单元装设；",{"key":24,"text":229,"correct":22},"重合闸装里宜按断路器为单元装设；",{"key":28,"text":231,"correct":22},"失灵保护宜按断路器为单元装设；",{"key":31,"text":233,"correct":26},"重合闸装置宜按线路为单元装设。",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":122,"analysis":34},1024130,"110~220kV中性点直接接地电力网中线路后备保护按（）原则配置。",[238,240,242,244],{"key":20,"text":239,"correct":22},"110kV线路宜采用远后备方式；",{"key":24,"text":241,"correct":26},"110kV线路宜采用近后备方式；",{"key":28,"text":243,"correct":22},"220kV线路宜采用近后备方式，但某些线路，如能实现远后备，則宜采用远后备或同时采用远、近结合的后备方式；",{"key":31,"text":245,"correct":26},"220kV线路宜采用远后备方式。",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":59,"analysis":34},1024131,"使用于220~500kV电网的微机距离保护，对其振荡闭锁的要求，（ ）是正确的。",[250,252,254,256],{"key":20,"text":251,"correct":22},"系统发生全相或非全相振荡，保护装置不应误动作跳闸；",{"key":24,"text":253,"correct":22},"系统在全相或非全相振荡过程中，被保护线路如发生各种类型的不对称故障，距离保护装里应有选择性地动作跳闸，纵联保护装里仍应快速动作；",{"key":28,"text":255,"correct":26},"系统全相根荡过程中发生三相故障，保护装里应能快速跳闸；",{"key":31,"text":257,"correct":22},"系统在全相振荡过程中发生三相故障，保护装置应能可靠动作跳闸，并允许带短延时。",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":97,"analysis":34},1024132,"对适用于220kV及以上电压的线路徽机继电保护装置，装置在交流电压失压情况下，（）是正确的。",[262,264,266,268],{"key":20,"text":263,"correct":26},"应在失压后自动退出保护；",{"key":24,"text":265,"correct":22},"应具有在失压情况下投入的后备保护功能；",{"key":28,"text":267,"correct":22},"在失压情况下，允许不保证选择性；",{"key":31,"text":269,"correct":26},"在失压情况下，必须保证选择性。",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":33,"analysis":34},1024133,"使用于220kV及以上电压的电力设备非电量保护（如瓦斯保护）下列要求正确的是（）。",[274,276,278,280],{"key":20,"text":275,"correct":22},"应相对独立，并具有独立的姚闸出3回路；",{"key":24,"text":277,"correct":26},"动作后应启动断路器失灵回路；",{"key":28,"text":279,"correct":26},"应启动重合闸装置；",{"key":31,"text":281,"correct":22},"不应启动断路器失灵保护。",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":294,"analysis":34},1024134,"微机继电保护装置中的零序电流方向元件采用的零序电压，下列要求中正确的是（）。",[286,288,290,292],{"key":20,"text":287,"correct":26},"接用电压互感器的开口三角电压；",{"key":24,"text":289,"correct":26},"采用自产零序电压，同时接用开口三角电压；",{"key":28,"text":291,"correct":22},"采用自产零序电压；",{"key":31,"text":293,"correct":22},"不能接用电压互感器开口三角电压。","CD",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":307,"analysis":34},1024135,"电力系统安全稳定控制的定义，以下分类正确的是（）。",[299,301,303,305],{"key":20,"text":300,"correct":26},"正常潮流控制；",{"key":24,"text":302,"correct":22},"预防控制；",{"key":28,"text":304,"correct":22},"紧急控制；",{"key":31,"text":306,"correct":22},"恢复控制。","BCD",{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":196,"analysis":34},1024136,"电力系统失步后，被分割为两部分，为实现再同步，对功率过剩一侧，正确的措施是（）。",[312,314,316,318],{"key":20,"text":313,"correct":22},"原动机减功率；",{"key":24,"text":315,"correct":22},"切除发电机；",{"key":28,"text":317,"correct":22},"某些送电系统解列；",{"key":31,"text":319,"correct":26},"切除部分负荷。",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":294,"analysis":34},1024137,"电力系统失步后，被分割为两部分，为实现再同步，对功率不足一侧，正确的措施是（）。",[324,326,327,329],{"key":20,"text":325,"correct":26},",切除发电机；",{"key":24,"text":313,"correct":26},{"key":28,"text":328,"correct":22},"切除负荷；",{"key":31,"text":330,"correct":22},"某些受电系统解列。",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":209,"analysis":34},1024138,"实时数据采集下列量（）。",[335,337,339,341],{"key":20,"text":336,"correct":22},"模拟量、状态量、带时间标志的亊件顺序记录量；",{"key":24,"text":338,"correct":22},"数字量、脉冲量、完整的电能量数据及调度自动化系统需要的其他数据；",{"key":28,"text":340,"correct":26},"摸拟量、数字量、状态量、带时同标志的亊件順序记录量、通信道运行质量数据；",{"key":31,"text":342,"correct":26},"状态量、数字量、完整的电能量数棋。",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":72,"analysis":34},1024139,"数据库管理正确的内容是（）。",[347,349,351,353],{"key":20,"text":348,"correct":22},"对历史与实时数据库有机协调统一管理i",{"key":24,"text":350,"correct":26},"支持并灵活设定历史数据存储周期和不少于二年的历史数据存贮能力，灵活的统计计算与方便的查询能力；",{"key":28,"text":352,"correct":22},"对数据库中的数据按电网中的设备为对象进行组织；",{"key":31,"text":354,"correct":22},"向用户提供统一的访问接口。",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":209,"analysis":34},1024140,"前置系统可按（）方式接人系统。",[359,361,363,365],{"key":20,"text":360,"correct":22},"异步；",{"key":24,"text":362,"correct":22},"同步；",{"key":28,"text":364,"correct":26},"链路；",{"key":31,"text":366,"correct":26},"串口。",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":33,"analysis":34},1024141,"在线经济调度运行方式()。",[371,373,375,377],{"key":20,"text":372,"correct":22},"可闭环控制；",{"key":24,"text":374,"correct":26},"不可附环控制；",{"key":28,"text":376,"correct":26},"不可开环运行；",{"key":31,"text":378,"correct":22},"可开环运行。",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":59,"analysis":34},1024142,"AGC\u002FEDC软件主要模块应包括().",[383,385,387,389],{"key":20,"text":384,"correct":22},"ACE计算A发送控制命令；",{"key":24,"text":386,"correct":22},"电厂控制器调节功率计算；",{"key":28,"text":388,"correct":26},"频偏（K)系数计算；",{"key":31,"text":390,"correct":22},"电厂控制器基准功率计算。",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":59,"analysis":34},1024143,"调度员培训仿真（DTS)用于（）。",[395,397,399,401],{"key":20,"text":396,"correct":22},"电网亊故仿真；",{"key":24,"text":398,"correct":22},"对办公管理人员进行概念性培训；",{"key":28,"text":400,"correct":26},"产生电网计算用的母线和网络模型。",{"key":31,"text":402,"correct":22},"培训值班调度员。",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":135,"analysis":34},1024144,"下列说法正确的是（ ）。 A. DMS通过FTU监控配电变电所的断路器及重合闸工作状态； B. DMS通过",[407,409,411,413],{"key":20,"text":408,"correct":26},"TU益控配电变电所的断路器及重合闸工作状态；",{"key":24,"text":410,"correct":22},"DMS通过",{"key":28,"text":412,"correct":26},"TU监控馈电线路设备的线路重合器的状态，分段器和柱上断路器状态；",{"key":31,"text":414,"correct":22},"DMS通过FTU监控馈电线路设备的线路重合器的状态，分段器和柱上断路器状态。",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":59,"analysis":34},1024145,"调度自动化系统主站应基本配置（）。",[419,421,423,425],{"key":20,"text":420,"correct":22},"服务器\u002F工作站与软件系统，前置系统；",{"key":24,"text":422,"correct":22},"网络设备、人机联系系统；",{"key":28,"text":424,"correct":26},"RTU,遥调、遥控执行设备；",{"key":31,"text":426,"correct":22},"电源系统、安全环保等。",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":135,"analysis":34},1024146,"现代EMS主站系统一般都采用（）.",[431,433,435,437],{"key":20,"text":432,"correct":26},"准分布式处理系统；",{"key":24,"text":434,"correct":22},"面向开放的系统结构；",{"key":28,"text":436,"correct":26},"集中式处理系统；",{"key":31,"text":438,"correct":22},"分布式处理系统。",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":33,"analysis":34},1024147,"由厂站和下级调度向上级调度传送的信息为（）。",[443,445,447,449],{"key":20,"text":444,"correct":22},"遥測信息及数据；",{"key":24,"text":446,"correct":26},"遥调命令；",{"key":28,"text":448,"correct":26},"遥控命令；",{"key":31,"text":450,"correct":22},"遥测信息。",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":294,"analysis":34},1024148,"远动终端与DMS配套的为（ ）。",[455,457,459,461],{"key":20,"text":456,"correct":26},"ERTU；",{"key":24,"text":458,"correct":26},"RTU;",{"key":28,"text":460,"correct":22},"FTU;",{"key":31,"text":462,"correct":22},"DTU、TTU。",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":135,"analysis":34},1024149,"微机型RTU主要类型有（）。",[467,469,471,473],{"key":20,"text":468,"correct":26},"分立元件式；",{"key":24,"text":470,"correct":22},"集中式；",{"key":28,"text":472,"correct":26},"集成电路式；",{"key":31,"text":474,"correct":22},"分布式。",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":72,"analysis":34},1024150,"宜装设四象限多功能电能表的位置为()。",[479,481,483,485],{"key":20,"text":480,"correct":22},"省级电网间和电网内的联络线路；",{"key":24,"text":482,"correct":26},"执行峰谷电价和功率因数调整电费的计量点；",{"key":28,"text":484,"correct":22},"具有穿越功率的送电线路和发电厂主变压器的高压侧；",{"key":31,"text":486,"correct":22},"具有并网自备发电机的用户线路。",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":294,"analysis":34},1024151,"下列传输速率属于远动数字通道的是（）。",[491,493,495,497],{"key":20,"text":492,"correct":26},"9600(bit\u002Fs);",{"key":24,"text":494,"correct":26},"1200(bit\u002Fs)；",{"key":28,"text":496,"correct":22},"64.384(kbit\u002Fs)；",{"key":31,"text":498,"correct":22},"2.32(Mbit\u002Fs)。",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":135,"analysis":34},1024152,"不是常用RTU的基本功能的是（）。",[503,505,507,509],{"key":20,"text":504,"correct":26},"采集并向远方发送状态量，遥信变位优先传送；",{"key":24,"text":506,"correct":22},"接收并执行遥调命令；",{"key":28,"text":508,"correct":26},"采集并向远方发送模拟量；",{"key":31,"text":510,"correct":22},"与两个及以上主站通信。",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":97,"analysis":34},1024153,"IEEE对SCADA\u002FEMS系统开放性定义是（）。",[515,517,519,521],{"key":20,"text":516,"correct":26},"前期产品与当前产品的硬\u002F软件兼容,",{"key":24,"text":518,"correct":22},"能够増扩或完全取代现存的EMS系统的郜分或全部；",{"key":28,"text":520,"correct":22},"对于所有的供应设备不依赖于某一个供货商（厂家）；",{"key":31,"text":522,"correct":26},"能不断改进和升级，以延长其系统的使用寿命。",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":97,"analysis":34},1024154,"6300kVA以下高压厂用变压器（带一段母线）电流速断保护装置配置应为（）",[527,529,531,533],{"key":20,"text":528,"correct":26},"两相二继电器式；",{"key":24,"text":530,"correct":22},"两相三继电器式；",{"key":28,"text":532,"correct":22},"三相三继电器式；",{"key":31,"text":534,"correct":26},"三相二继电器式。",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":72,"analysis":34},1024155,"频率特性系数K的解释正确的是（）。",[539,541,543,545],{"key":20,"text":540,"correct":22},"是一个常数，不是变量；",{"key":24,"text":542,"correct":26},"通过精确测量获得；",{"key":28,"text":544,"correct":22},"表示频率下降0.1Hz，系统缺少的功牟（MW\u002F0.1Hz)；",{"key":31,"text":546,"correct":22},"通过试驗与统计资料方法获得。",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":307,"analysis":34},1024156,"关于交流采样分布式 B.TU,下列说法正确的是（）。",[551,553,555,557],{"key":20,"text":552,"correct":26},"从电量变送器获取直流信号经模\u002F数变换得到测量值；",{"key":24,"text":554,"correct":22},"从现场设备TA\u002FTV获取信号经DSP计算得到测量值；",{"key":28,"text":556,"correct":22},"采用综合功能I\u002FO单元，适合于现场分散布里；",{"key":31,"text":558,"correct":22},"具备将分时电能表和I\u002FO单元集成在一起的条件。",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":307,"analysis":34},1024157,"状态估计软件应具有（）。",[563,565,567,569],{"key":20,"text":564,"correct":26},"产生电两计算用的母线和网络模型；",{"key":24,"text":566,"correct":22},"的开关構该辨识能力；",{"key":28,"text":568,"correct":22},"对遥測数据中不良数据进行检測和辨识能力；",{"key":31,"text":570,"correct":22},"对变压器分接头位置估计，母线负荷预报、量測误差分析统计屏蔽修改等。",{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":196,"analysis":34},1024158,"配电管理系统（DMS)的负荷管理(LM)功能用以（）。",[575,577,579,581],{"key":20,"text":576,"correct":22},"控制用户负荷，削峰和减载；",{"key":24,"text":578,"correct":22},"帮助控制中心操作页制定负荷控制策略和计划；",{"key":28,"text":580,"correct":22},"实现对配网负荷的监控、预測和分配；",{"key":31,"text":582,"correct":26},"进行负荷頻率控制，保持系统頻率在规定值内。",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":59,"analysis":34},1024159,"主站端系统的系统软件结构要求().",[587,589,591,593],{"key":20,"text":588,"correct":22},"开放；",{"key":24,"text":590,"correct":22},"通用;",{"key":28,"text":592,"correct":26},"模拟化；",{"key":31,"text":594,"correct":22},"符合国际标准。",{"id":596,"libraryId":5,"type":15,"typeLabel":16,"stem":597,"options":598,"answer":59,"analysis":34},1024160,"问答式远动传输规约（Polling)适用于（）。",[599,601,603,605],{"key":20,"text":600,"correct":22},"点对点；",{"key":24,"text":602,"correct":22},"多点星形；",{"key":28,"text":604,"correct":26},"两点串接；",{"key":31,"text":606,"correct":22},"多点环形。",{"id":608,"libraryId":5,"type":15,"typeLabel":16,"stem":609,"options":610,"answer":97,"analysis":34},1024161,"装设发电机的匝间短路保护应符合的条件有（）。",[611,613,615,617],{"key":20,"text":612,"correct":26},"定子绕组为星形接线，每相有并联分支的发电机；",{"key":24,"text":614,"correct":22},"50MW及以上发电机定子绕组为星形接线，中性点只有三个引出端子的发电机；",{"key":28,"text":616,"correct":22},"定子绕组为星形接线，每相有并联分支且中性点有分支引出端子的发电机；",{"key":31,"text":618,"correct":26},"定子绕组为双星形接线的发电机。",{"id":620,"libraryId":5,"type":15,"typeLabel":16,"stem":621,"options":622,"answer":97,"analysis":34},1024162,"对50MW及以上发电机外部相间短路故障和作为发电机主保护的后备，可装设的保护有（）。",[623,625,627,629],{"key":20,"text":624,"correct":26},"低电压闭锁过流保护；",{"key":24,"text":626,"correct":22},"复合电压启动的过电流保护；",{"key":28,"text":628,"correct":22},"负序过电流和单元件低压启动过电流保护；",{"key":31,"text":630,"correct":26},"当装上述保护不能满足要求时，用阻抗保护。",[632,636,639,642,645,648],{"id":633,"name":634,"category":7,"favorite":635},1,"领导干部任职前廉政法规知识测试题",92,{"id":637,"name":638,"category":7,"favorite":633},595,"建筑结构与设备",{"id":640,"name":641,"category":7,"favorite":633},715,"招标采购专业知识与法律法规",{"id":643,"name":644,"category":7,"favorite":633},848,"市政方向-通用基础",{"id":646,"name":647,"category":7,"favorite":8},534,"BIM工程师",{"id":649,"name":647,"category":7,"favorite":8},535]