[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-46":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":630},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,46,50,2670,[13,35,48,61,74,86,98,110,122,134,146,159,171,183,195,208,220,232,244,256,269,281,293,305,317,329,341,353,365,377,389,401,413,425,437,449,461,473,485,498,510,522,534,546,558,570,582,594,606,618],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},1024013,2,"多选题","送电线路、配电装置及电气设备的绝缘配合方法有（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","工程计算法；",false,{"key":24,"text":25,"correct":26},"B","统计法；",true,{"key":28,"text":29,"correct":26},"C","简化统计法；",{"key":31,"text":32,"correct":26},"D","确定性法，","BCD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":47,"analysis":34},1024014,"在变电所的绝缘配合中，对于清洁区变电所的绝缘于串应该同时符合以下（）要求。",[39,41,43,45],{"key":20,"text":40,"correct":26},"絶缘子串正极性操作冲击电压波50%放电电压的计算值，应符合操作过电压的要求；",{"key":24,"text":42,"correct":26},"绝缘子串正极性雷电冲击电压波50%放电电压计算值，应符合变电所雷电过电压的要求；",{"key":28,"text":44,"correct":22},"絶缘子串正极性工频过电压波50%放电电压计算值，应符合变电所工頻过电压要求； ,",{"key":31,"text":46,"correct":26},"每串绝缘子片数应满足工频电压爬电距离计算值的要求。","ABD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":34},1024015,"操作过电压下的绝缘配合中，电压范围II电气设备的相对地绝缘，一般是根据设备上的统计操作过电压水平或避雷器的操作冲击保护水平和设备的绝缘特性，并取一定的配合因数Kc计算、选取设备的额定操作耐受电压的。其中配合因数Kc要考虑下列（）因素。",[52,54,56,58],{"key":20,"text":53,"correct":26},"设备生产及安装质量；",{"key":24,"text":55,"correct":26},"过电压幅值及分布特性；",{"key":28,"text":57,"correct":26},"绝缘类型及其特性、性能指标、过电压幅值及分布特性；",{"key":31,"text":59,"correct":22},"运行条件。","ABC",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":73,"analysis":34},1024016,"对下列的变压器类设备选用的短时工频（1min）相对地耐受电压数值中，正确的是（）。",[65,67,69,71],{"key":20,"text":66,"correct":26},"3kV系统20kV;",{"key":24,"text":68,"correct":22},"15kV系统85kV;",{"key":28,"text":70,"correct":26},"110kV系统185\u002F200kV（外\u002F内绝缘）；",{"key":31,"text":72,"correct":26},"500kV系统630kV（对应于雷电冲击耐受电压1425kV）。","ACD",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":33,"analysis":34},1024017,"在选用设备的额定耐受电压及其组合时，对同一设备的最高电压，有的给出两个及以上的绝缘水平，这主要是结合考虑了以下（）因索。",[78,80,82,84],{"key":20,"text":79,"correct":22},"设备的生产、制造条件和安装质量；",{"key":24,"text":81,"correct":26},"电网结构及过电压水平；",{"key":28,"text":83,"correct":26},"C过电压保护装里的配里及其性能；",{"key":31,"text":85,"correct":26},"设备类型、绝缘特性及可接受的绝缘故陣率。",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":60,"analysis":34},1024018,"设备在运行中可能受到的作用电压，按照作用电压的幅值、波形及持续时间可分为（）。",[90,92,94,96],{"key":20,"text":91,"correct":26},"持续工频过电压；",{"key":24,"text":93,"correct":26},"暂时过电压；",{"key":28,"text":95,"correct":26},"缓波前（操作）过电压；",{"key":31,"text":97,"correct":22},"快波前（操作）过电压。",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":60,"analysis":34},1024019,"谐振过电压包括（）。",[102,104,106,108],{"key":20,"text":103,"correct":26},"传递过电压；",{"key":24,"text":105,"correct":26},"电磁式电压互感器饱和过电压；",{"key":28,"text":107,"correct":26},"发电机同步或异步自助磁过电压；",{"key":31,"text":109,"correct":22},"甩负荷过电压。",{"id":111,"libraryId":5,"type":15,"typeLabel":16,"stem":112,"options":113,"answer":47,"analysis":34},1024020,"降低范围II系统的工频过电压水平，一般采用的措施有（）。",[114,116,118,120],{"key":20,"text":115,"correct":26},"在线路上安装氧化锌避雷器；",{"key":24,"text":117,"correct":26},"在线路上安装并联电抗器；",{"key":28,"text":119,"correct":22},"在线路上安装串联电容器；",{"key":31,"text":121,"correct":26},"在线路上装设良导体避雷线。",{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":73,"analysis":34},1024021,"为防止发电机电感参数周期性变化引起的发电机自励磁过电压，一般可采取下列防止措施（）.",[126,128,130,132],{"key":20,"text":127,"correct":26},"使发电机的容量大于被投入空载线路的充电功率；",{"key":24,"text":129,"correct":22},"使发电机带空载线路启动；",{"key":28,"text":131,"correct":26},"避免以全电压向空载线路合闸；",{"key":31,"text":133,"correct":26},"利用快速励磁自动调节器。",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":47,"analysis":34},1024022,"在范围II的系统当空载线路上接有并联电抗器时，在并联电抗器的中性点与大地之间串接一接地电抗器，以防止铁磁谐振过电压的产生。该接地电抗器的选择需考虑（）因素。",[138,140,142,144],{"key":20,"text":139,"correct":26},"并联电抗器所接线路的相间电容；",{"key":24,"text":141,"correct":26},"并联电抗器、接地电抗器的电抗与线路电抗的实际值与设计值的变异范围；",{"key":28,"text":143,"correct":22},"限制短路电流的要求；",{"key":31,"text":145,"correct":26},"并联电抗器中性点绝缘水平。",{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":158,"analysis":34},1024023,"如发电厂采用发电机一变压器一线路单元接线接人500kV系统时，满足（ ）条件时，可仅用金属氧化物避雷器限制合闸和重合闸过电压。",[150,152,154,156],{"key":20,"text":151,"correct":26},"发电机容量为300MW、线路长度小于150km;",{"key":24,"text":153,"correct":22},"发电机容量为300MW、线路长度小于180km;",{"key":28,"text":155,"correct":26},"发电机容量不小于500MW、线路长度小于200km;",{"key":31,"text":157,"correct":22},"发电机容量不小于500MW、线路长度小于230km。","AC",{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":47,"analysis":34},1024024,"造成真空断路器开断高压感应电动机产生过电压的原因有（）。",[163,165,167,169],{"key":20,"text":164,"correct":26},"截流；",{"key":24,"text":166,"correct":26},"三相同时开断；",{"key":28,"text":168,"correct":22},"两相同时开断；",{"key":31,"text":170,"correct":26},"高频重复重击穿。",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":73,"analysis":34},1024025,"影响真空断路器开断高压感应电动机产生过电压的幅值的因素有（）。",[175,177,179,181],{"key":20,"text":176,"correct":26},"断路器熄弧性能；",{"key":24,"text":178,"correct":22},"断路器开断性能；",{"key":28,"text":180,"correct":26},"电动机参数；",{"key":31,"text":182,"correct":26},"回路元件参数。",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":47,"analysis":34},1024026,"发电厂和变电所内产生雷电过电压的因素有（）。",[187,189,191,193],{"key":20,"text":188,"correct":26},"雷电对配电装里的直接雷击；",{"key":24,"text":190,"correct":26},"雷电对配电装里的反击；",{"key":28,"text":192,"correct":22},"雷电对配电装里的绕击；",{"key":31,"text":194,"correct":26},"架空进线上的雷电侵入波。",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":207,"analysis":34},1024027,"对高压配电装置进行直击雷保护应采用的措施有（）。",[199,201,203,205],{"key":20,"text":200,"correct":26},"采用避雷针；",{"key":24,"text":202,"correct":26},"采用避雷线；",{"key":28,"text":204,"correct":22},"采用金属氧化物避雷器；",{"key":31,"text":206,"correct":22},"采用碳化硅避雷器。","AB",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":60,"analysis":34},1024028,"采用阀式避雷器进行雷电过电压保护时，以下避雷器选型正确的是（）。",[212,214,216,218],{"key":20,"text":213,"correct":26},"有效接地系统、范围I应选用金属氧化物避雷器；",{"key":24,"text":215,"correct":26},"有效接地系统、范围I宜选用金属氧化物避雷器；",{"key":28,"text":217,"correct":26},"气体绝缘全封闭组合电器应选用金属氧化物避雷器；",{"key":31,"text":219,"correct":22},"低电阻接地系统应选用碳化硅避雷器。",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":60,"analysis":34},1024029,"采用串联间隙金属氧化物避雷器进行雷电过电压保护时，以下额定电压的正确选择是（）。 ，",[224,226,228,230],{"key":20,"text":225,"correct":26},"110k1V及220kV有效接地系统，其颏定电压不低于0.8Um；",{"key":24,"text":227,"correct":26},"35、66kV系统，其额定电压不低于1.2Um；",{"key":28,"text":229,"correct":26},"3~1OkV系统，其额定电压不低于1.1Um；",{"key":31,"text":231,"correct":22},"3kV及以上具有发电机的系统，其额定电压不低于1.1Um。",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":60,"analysis":34},1024030,"发电厂和变电所直击雷保护中，应装设直击雷保护装置的是（）。",[236,238,240,242],{"key":20,"text":237,"correct":26},"屋外配电装置，包括组合导线和母线廊道；",{"key":24,"text":239,"correct":26},"火力发电厂的烟囱、冷却塔和输煤系统的高建筑物；",{"key":28,"text":241,"correct":26},"燃油泵房、露天油權及其架空管道、装卸油台、易燃材料仓库等建筑物；",{"key":31,"text":243,"correct":22},"户外式布置的GIS外壳。",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":60,"analysis":34},1024031,"下列发电厂直击雷保护中叙述正确的是（）。",[248,250,252,254],{"key":20,"text":249,"correct":26},"发电厂的主厂房、主控制室和配电装I室一般不装设直击雷保护装里；",{"key":24,"text":251,"correct":26},"雷电活动特殊强烈地区的主厂房、主控制室和配电装里室宜设直击雷保护装置；",{"key":28,"text":253,"correct":26},"主厂房如装设直击雷保护装置或为保护其他设备而在主厂房装设避雷针，应采取加强分流，装设集中接地装里；",{"key":31,"text":255,"correct":22},"峡谷地区的发电厂宜用独立避雷针保护。",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":268,"analysis":34},1024032,"某发电厂易燃油罐区，贮油罐体积为800m3，贮油罐高度为10m，采用独立避雷针进行直击雷保护，避雷针的集中接地装置的冲击接地电阻为70，其避雷针的设置应满足的要求包括（）。",[260,262,264,266],{"key":20,"text":261,"correct":22},"避雷针与易燃油贮維及其呼吸阀等之间的空中距离需大于2.4m;",{"key":24,"text":263,"correct":26},"进雷针及其接地装置与罐体、罐体的接地装置及地下管道的地中距离应大于2.1m;",{"key":28,"text":265,"correct":22},"避雷针与油罐呼吸阀的水平距离不应小于2m;",{"key":31,"text":267,"correct":26},"避雷针针尖高出油罐呼吸阀不应小于3m。","BD",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":47,"analysis":34},1024033,"某220kV变电所场地狭小，采用220、110kV及1OkV三级电压出线，土壤电阻率为200Ω?m。若在主变压器门型构架上装设避雷针，正确的是（）。",[273,275,277,279],{"key":20,"text":274,"correct":26},"装在变压器门型构架上的避雷针应与接地网相连，并应沿不同方向引出3~4根放射性水平接地体；",{"key":24,"text":276,"correct":26},"在每根水平接地体上离避雷针构架3~5m处装设一根垂直接地体；",{"key":28,"text":278,"correct":22},"直接在1OkV绕组出线上装设阀式避雷器；",{"key":31,"text":280,"correct":26},"离变压器电气距离大于5m处装设阀式避雷器。",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":33,"analysis":34},1024034,"线路避雷线引至各级配电装置的出线门型架构的要求，如下叙述正确的是（）。",[285,287,289,291],{"key":20,"text":286,"correct":22},"11OkV及以上配电装置可将线路避雷线引至出线门型架构上，但土壤电阻率大于1200Ω?m的地区应装设集中接地装置；",{"key":24,"text":288,"correct":26},"110kV及以上配电装置可将线路避雷线引至出线门型架构上，但土壌电阻率大于1OOOΩ?m的地区应装设集中接地装里；",{"key":28,"text":290,"correct":26},"35,66kV配电装置，在土壤电阻率不大于500Ω?m的地区，允许将线路避雷线引主出线门型架构上，应装设集书接地装里；",{"key":31,"text":292,"correct":26},"35、66kV配电装置，在土壤电阻率大于500Ω?m的地区，不允许将线路避雷线引至出线门型架构上，",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":73,"analysis":34},1024035,"关于金属氧化锌避雷器与主变压器的最大电气距离，叙述正确的是（）。",[297,299,301,303],{"key":20,"text":298,"correct":26},"110kV系统，进线长度1km、进线回路2回，则金属氧化辞避雷器与主变压器的最大电气距离为85m；",{"key":24,"text":300,"correct":22},"110kV系统，进线长度1.5km、进线回路3回，则金属氧化锌避雷器与主变压器的最大电气距离为155m；",{"key":28,"text":302,"correct":26},"110kV系统，进线长度2km、进线回路4回，则金属氣化锌避雷器与主变压器的最大电气距离为230m；",{"key":31,"text":304,"correct":26},"220kV系统，进线长度2km、进线回路3回，则金属氧化辞避雷器与主变压器的最大电气距离为235m。",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":60,"analysis":34},1024036,"操作过电庄下变电所的绝缘配合，正确的叙述是（）。",[309,311,313,315],{"key":20,"text":310,"correct":26},"范围I变电所絶缘子串、空气间隙的操作过电压要求的绝缘水平，以计算用最大操作过电压为基础进行绝缘配合；",{"key":24,"text":312,"correct":26},"范围II变电所绝缘子串、空气间隙的操作冲击绝缘强度，以避雷器相应保护水平为基础进行絶缘配合；",{"key":28,"text":314,"correct":26},"对范围II变电所电气设备进行操作冲去绝缘配合时，对非自恢复绝缘采用惯用法；",{"key":31,"text":316,"correct":22},"对范围II变电所电气设备进行搡作冲击绝缘配合时，对自恢复绝缘采用统计法。",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":60,"analysis":34},1024037,"当变电所因海拔髙度引起气象条件变化而异于标准状态时，为满足绝缘配合的要求，正确的是（）。",[321,323,325,327],{"key":20,"text":322,"correct":26},"对空气间隙，不考虑雨的影响，仅进行相对空气密度和湿度的校正：",{"key":24,"text":324,"correct":26},"对绝缘子串，工频污秽放电电压暂不进行校正；",{"key":28,"text":326,"correct":26},"对操作冲击电压波放电电压，不考虑雨的影响，进行相对空气密度和湿度的校正；",{"key":31,"text":328,"correct":22},"对操作冲击电压波放电电压，考虑雨的影响使绝缘子正极性冲击电压波放电电压降低8%，再进行相对空气密度的校正。",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":33,"analysis":34},1024038,"对范围I各电压级相对地和相间计算用最大操作过电压标么值的选取，下列系数中正确的是（）。",[333,335,337,339],{"key":20,"text":334,"correct":22},"35kV及以下低电阻接地系统，其相对地计算用最大搮作过电压标么值取3.0；",{"key":24,"text":336,"correct":26},"66kV及以下（除低电阻接地系统外），其相对地计算用最大操作过电压标么值取4.0；",{"key":28,"text":338,"correct":26},"110kV及220kV系统，其相对地计算用最大操作过电压标么值取3.0；",{"key":31,"text":340,"correct":26},"3~220kV系统，其相间计算用最大操作过电压标么值取相应的相对地计算用最大操作过电压标么值的1.3~1.4倍。",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":60,"analysis":34},1024039,"在进行变电所绝缘子串雷电过电压绝缘配合时，应考虑的因素是（）。",[345,347,349,351],{"key":20,"text":346,"correct":26},"对500kV系统，应选取20kA标称雷电电流下的残压值进行絶缘配合；",{"key":24,"text":348,"correct":26},"对330kV和220kV系统，应选取1OkA标称雷电电流下的残压值进行绝缘配合；",{"key":28,"text":350,"correct":26},"对3~110kV系统，应选取5kA标称雷电电流下的残压值进行绝缘配合；",{"key":31,"text":352,"correct":22},"绝缘子串的雷电过电压配合系数都取为1.5。",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":47,"analysis":34},1024040,"在计算变电所导线对构架的空气间隙时，如下考虑因素正确的是（）。",[357,359,361,363],{"key":20,"text":358,"correct":26},"变电所相对地空气间隙在操作过电压下放电电压的变异系数取",{"key":24,"text":360,"correct":26},"变电所相间空气间隙在操作过电压下放电电压的变异系数取3.5%;",{"key":28,"text":362,"correct":22},"变电所相对地空气间隙雷电过电压的配合系数，有风偏间隙取1.4，无风偏同隙取1.5；",{"key":31,"text":364,"correct":26},"变电所的雷电过电压相间空气间隙可取相应的相对地空气间隙的1.1倍。",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":73,"analysis":34},1024041,"在进行500kV电气设备操作过电压绝缘配合时，应遵循的原则是（）。",[369,371,373,375],{"key":20,"text":370,"correct":26},"电气设备内绝缘相对地額定操作冲击耐压与避雷器操作冲击保炉水平间的配合系数不应小于1.15;",{"key":24,"text":372,"correct":22},"电气设备外绝缘相对地干态额定操作冲击耐压与相应设备的内絶缘相对地额定操作冲击耐压相同，淋雨耐压值可低3%；",{"key":28,"text":374,"correct":26},"变压器内絶缘相间额定操作冲击耐压取其等于内绝缘相对地颏定操作冲击耐压的1.5倍；",{"key":31,"text":376,"correct":26},"变压器外绝缘相间干态額定操作冲击耐压与其于内绝缘相间额定操作冲击耐压相同。",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":73,"analysis":34},1024042,"空气间隙的绝缘特性有（）。",[381,383,385,387],{"key":20,"text":382,"correct":26},"有自恢复性；",{"key":24,"text":384,"correct":22},"冲击耐压与湿度无关;",{"key":28,"text":386,"correct":26},"冲击耐压与极性有关；",{"key":31,"text":388,"correct":26},"冲击耐压与间隙长度有非线性关系。",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":47,"analysis":34},1024043,"工频电压下，绝缘配合的原则是（）。",[393,395,397,399],{"key":20,"text":394,"correct":26},"工頻运行电压下电瓷外绝缘的爬电距离应符合相应环境污秽等级的爬电比距要求；",{"key":24,"text":396,"correct":26},"电气设备应能承受一定幅值和时间的工頻过电压；",{"key":28,"text":398,"correct":22},"能承受一定幅值和时间的故障冲击波；",{"key":31,"text":400,"correct":26},"电气设备应能承受一定幅值和时间的谐振过电压。",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":60,"analysis":34},1024044,"操作过电压下，绝缘配合的原则是（）。",[405,407,409,411],{"key":20,"text":406,"correct":26},"330kV及以上送电线路仅考虑空载线路合闸、单相重合闸和成功的三相重合闸（如运行中使用）时的操作过电压；",{"key":24,"text":408,"correct":26},"330kV及以上变电所电气设备及绝缘子串、空气间隙的操作冲击强度，以避雷器相应保护水平为基础，进行绝缘配合；",{"key":28,"text":410,"correct":26},"220kV及以下变电所和线路的绝缘子串及空气间隙的搡作过电压要求的绝缘水平，以计算用最大操作过电压为基础进行配合；",{"key":31,"text":412,"correct":22},"操作过电压下绝缘配合，可不考虑海拔高度的修正。",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":33,"analysis":34},1024045,"标准中送电线路和变电所绝缘子串及空气间隙的绝缘配合公式均按标准气象条件给出，在髙海拔地区还应按规程进行校主，校正中应考虑的规定有（）。 A.雷电过电压可不作校正； B.空气间隙不考虑雨的影响，仅进行相对空气密度和?显度的校正；",[417,419,421,423],{"key":20,"text":418,"correct":22},"絶缘子串的工频污秽放电电压暂不进行校正；",{"key":24,"text":420,"correct":26},"絶缘子串正极性搮作冲击波放电电压按以下两种方法校正，取严苛条件值：",{"key":28,"text":422,"correct":26},"（1）考虑雨使放电电压降低5%，再进行相对空气密度校正；",{"key":31,"text":424,"correct":26},"（2）不考虑雨的影响，但进行相对空气密度和湿度的校正。",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":60,"analysis":34},1024046,"送电线路塔头设计要便利带电作业，应考虑的规定有（）。",[429,431,433,435],{"key":20,"text":430,"correct":26},"带电部分对杆塔接地部分的间隙应满足规定要求（如110kV时大于1.0m，220kV时大于1.8m,330kV时大于2.2m,500kV时大于3.2m）;",{"key":24,"text":432,"correct":26},"操作人员需要停留工作的部位，还应考虑人体活动范围30~50cm;",{"key":28,"text":434,"correct":26},"校验带电作业的间隙时，采用气温+15℃，风速10m\u002Fs的气象条件；",{"key":31,"text":436,"correct":22},"应考虑工頻过电压和谐振过电压对带电作业的影响。",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":47,"analysis":34},1024047,"接地装置按用途可分为（）。",[441,443,445,447],{"key":20,"text":442,"correct":26},"工作接地；",{"key":24,"text":444,"correct":26},"防磁感应接地；",{"key":28,"text":446,"correct":22},"雷电保护接地；",{"key":31,"text":448,"correct":26},"防静电接地。",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":60,"analysis":34},1024048,"A类电气装置中，金属部分均应接地的装置有（）。",[453,455,457,459],{"key":20,"text":454,"correct":26},"电机、变压器和高压电器等的底座和外壳；",{"key":24,"text":456,"correct":26},"电气设备传动装置；",{"key":28,"text":458,"correct":26},"配电、控制、保护用的屏（拒、箱）及操作台等的金属框架》",{"key":31,"text":460,"correct":22},"安装在配电屏、控制屏和配电装置上的电測量仪表、继电器和其他低压电器等的外壳。",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":158,"analysis":34},1024049,"确定发电厂、变电站接地装置的型式和布置时，考虑保护接地的要求，常用的接地装置的接触电位差（Ut）和跨步电位差（Us）允许值的计算式适用于（）。",[465,467,469,471],{"key":20,"text":466,"correct":26},"110kV及以上有效接地系统；",{"key":24,"text":468,"correct":22},"3~66kV不接地或经消弧线圈接地系统；",{"key":28,"text":470,"correct":26},"6~35kV低电阻接地系统；",{"key":31,"text":472,"correct":22},"3~66kV高电阻接地系统。",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":60,"analysis":34},1024050,"保护配电设备的避雷器明确要求接地线应与设备外壳相连，且其接地装置的接地电阻不应大于10Ω的配电设备是（）。",[477,479,481,483],{"key":20,"text":478,"correct":26},"柱上断路器；",{"key":24,"text":480,"correct":26},"负荷开关；",{"key":28,"text":482,"correct":26},"电容器组；",{"key":31,"text":484,"correct":22},"配电变压器。",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":497,"analysis":34},1024051,"发电厂、变电站电气装置的接地装置，人工接地网均压带采用的布置方式有（）。",[489,491,493,495],{"key":20,"text":490,"correct":22},"分散布里；",{"key":24,"text":492,"correct":22},"放射布置；",{"key":28,"text":494,"correct":26},"等间距布置；",{"key":31,"text":496,"correct":26},"不等间距布里。","CD",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":73,"analysis":34},1024052,"为防止转移电位引起的危害，对可能将接地网的髙电位引向厂站外，或将低电位引向厂站内的设施，一般采取的隔离措施有（）。",[502,504,506,508],{"key":20,"text":503,"correct":26},"对外的通信设备加隔离变压器；",{"key":24,"text":505,"correct":22},"向外供电的低压线路采用电缆，其电源中性点选在内面适当的地方接地；",{"key":28,"text":507,"correct":26},"铁路轨道分别在两处加绝缘鱼尾板；",{"key":31,"text":509,"correct":26},"通向厂、所外的管道采用绝缘段。",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":73,"analysis":34},1024053,"当变电站采用了在室内楼板上布置500kV GIS配电装置时，其接地线及其连接应该满足的要求是（）。",[514,516,518,520],{"key":20,"text":515,"correct":26},"GIS基座上的每一接地母线，应采用分设其两端的接地线与全站接地网连接，接地线并应和GIS室内环形接地母线连接；",{"key":24,"text":517,"correct":22},"接地线截面应进行动、热稳定校验；",{"key":28,"text":519,"correct":26},"GIS的接地开关、金属氧化物避雷器的专用接地端子与GIS接地母线的连接处，宜装设集中接地装置；",{"key":31,"text":521,"correct":26},"GIS室内应教设环形接地母线，室内各种设备需接地的部位应以最短路径与环形接地母线连接。",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":47,"analysis":34},1024054,"B类电气装置采用接地故障保护时，对建筑物内应采用总等电位连接线互相可靠连接的导电部分包括（）。",[526,528,530,532],{"key":20,"text":527,"correct":26},"建筑物内的水管、煤气管、采暖和空调管道等金属管道；",{"key":24,"text":529,"correct":26},"电气装置的接地装置中的接地干线；",{"key":28,"text":531,"correct":22},"建筑物内的通信线；",{"key":31,"text":533,"correct":26},"便于连接的建筑物金属构件等导电部分。",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":33,"analysis":34},1024055,"对B类电气装置的接地装置的等电位连接接线有（）要求。",[538,540,542,544],{"key":20,"text":539,"correct":22},"应采取防止杂散电流的绝缘措施；",{"key":24,"text":541,"correct":26},"等电位连接主母线的最小截面应不小于装置最大保护线截面的一半，且不应小于6mm2,当采用铜线时，其截面不宜大于25mm2;",{"key":28,"text":543,"correct":26},"连接两个外露导电部分的辅助等电位连接线，其截面不应小于接至该两个外露导电部分的较小保护线的截面；",{"key":31,"text":545,"correct":26},"当建筑物的水管被用作接地线或保护线时，水表必须跨接连接，其连接线的我面应根据其功能要求而采用适当的截面。",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":33,"analysis":34},1024056,"在髙土壤电阻率地区，可采取的降低接地电阻的措施有（）。",[550,552,554,556],{"key":20,"text":551,"correct":22},"在2000m以外敷设外引接地极；",{"key":24,"text":553,"correct":26},"采用井式或深钻式接地极；",{"key":28,"text":555,"correct":26},"填充降阻剂；",{"key":31,"text":557,"correct":26},"敷设水下接地网，",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":73,"analysis":34},1024057,"接地装置的导体设计应考虑的因素是（）",[562,564,566,568],{"key":20,"text":563,"correct":26},"导体应符合热稳定与均压的要求；",{"key":24,"text":565,"correct":22},"应考虑海拔高度的影响；",{"key":28,"text":567,"correct":26},"应考虑腐蚀的影响；",{"key":31,"text":569,"correct":26},"应满足机械弦度要求。",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":47,"analysis":34},1024058,"对于发电厂、变电站电气装置的人工接地网，下列要求中正确的是（）。",[574,576,578,580],{"key":20,"text":575,"correct":26},"人工接地网外缘应闭合，外缘各角应做成圆弧形；",{"key":24,"text":577,"correct":26},"接地网内应敷设水平均压带；",{"key":28,"text":579,"correct":22},"接地网埋深不宜小于0.8m;",{"key":31,"text":581,"correct":26},"接地网均压带可采用等间距或不等间距布置。",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":47,"analysis":34},1024059,"接地装置防腐设计应满足的要求是（）。",[586,588,590,592],{"key":20,"text":587,"correct":26},"设计使用年限与地面工程相当；",{"key":24,"text":589,"correct":26},"应取得当地的腐蚀数据；",{"key":28,"text":591,"correct":22},"在腐蚀严重地区，所有敷设在地面下和地面上的接地线，均应采用涂上一层沥青的方式来防腐；",{"key":31,"text":593,"correct":26},"接地装里的焊接点应涂防腐材料。",{"id":595,"libraryId":5,"type":15,"typeLabel":16,"stem":596,"options":597,"answer":60,"analysis":34},1024060,"当人工接地网局部地带的接触电位差、跨步电位差超过规定信时，应采取的措施包括（）。",[598,600,602,604],{"key":20,"text":599,"correct":26},"局部増设水平均压带；",{"key":24,"text":601,"correct":26},"増设垂直接地极；",{"key":28,"text":603,"correct":26},"销设碎石地面或沥青地面；",{"key":31,"text":605,"correct":22},"填充电阻率较低的物质或降阻剂。",{"id":607,"libraryId":5,"type":15,"typeLabel":16,"stem":608,"options":609,"answer":33,"analysis":34},1024061,"发电厂、变电站电气装置中，应采取专门敷设接地线的电气设施是（）。",[610,612,614,616],{"key":20,"text":611,"correct":22},"互感器的二次绕组；",{"key":24,"text":613,"correct":26},"直接接地的变压器中心点；",{"key":28,"text":615,"correct":26},"GIS的接地端子；",{"key":31,"text":617,"correct":26},"避雷器、避雷针的接地端子。",{"id":619,"libraryId":5,"type":15,"typeLabel":16,"stem":620,"options":621,"answer":60,"analysis":34},1024062,"发电厂、变电站电气设备接地线的连接，下列连接要求中正确的是（）。",[622,624,626,628],{"key":20,"text":623,"correct":26},"接地线采用焊接连接；",{"key":24,"text":625,"correct":26},"当利用穿线的钢管作接地线时，引向电气设备的钢管与电气设备之间，应有可靠的电气连接；",{"key":28,"text":627,"correct":26},"接地线与电气设备的连接，可用螺栓连接或焊接；",{"key":31,"text":629,"correct":22},"当单个电气设备接地部分与接地母线较远时，宜采用多个设备串接后与接地母线连接。",[631,635,638,641,644,647],{"id":632,"name":633,"category":7,"favorite":634},1,"领导干部任职前廉政法规知识测试题",92,{"id":636,"name":637,"category":7,"favorite":632},595,"建筑结构与设备",{"id":639,"name":640,"category":7,"favorite":632},715,"招标采购专业知识与法律法规",{"id":642,"name":643,"category":7,"favorite":632},848,"市政方向-通用基础",{"id":645,"name":646,"category":7,"favorite":8},534,"BIM工程师",{"id":648,"name":646,"category":7,"favorite":8},535]