[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-45":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":625},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,45,50,2670,[13,35,44,56,68,81,94,107,119,132,144,156,168,180,192,204,216,228,241,253,265,277,289,301,313,325,337,349,361,373,385,395,407,419,431,443,456,468,480,492,504,516,528,540,552,565,577,589,601,613],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":33,"analysis":34},1023963,2,"多选题","应校验断路器的并联开断性能的接线有（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","一台半断路器接线；",true,{"key":24,"text":25,"correct":26},"B","双母线接线；",false,{"key":28,"text":29,"correct":22},"C","桥形接线；",{"key":31,"text":32,"correct":22},"D","双断路器接线。","ACD","",{"id":36,"libraryId":5,"type":15,"typeLabel":16,"stem":37,"options":38,"answer":43,"analysis":34},1023964,"图6-1所示电压互感器的接线中，不能供电给绝缘检查电压表的是（）。",[39,40,41,42],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},"AC",{"id":45,"libraryId":5,"type":15,"typeLabel":16,"stem":46,"options":47,"answer":33,"analysis":34},1023965,"发电机中性点经高电阻接地的目的是（）。",[48,50,52,54],{"key":20,"text":49,"correct":22},"为发电机定子接地保护提供电源，便于检测；",{"key":24,"text":51,"correct":26},"限制长时间中性点位移电压不超过10%×Ue\u002F√3",{"key":28,"text":53,"correct":22},"限制接地故障电洗尽可能不超过10~15A；",{"key":31,"text":55,"correct":22},"限制接地故陣时，健全相的瞬时过电压不超过2.6倍的额定相电压。",{"id":57,"libraryId":5,"type":15,"typeLabel":16,"stem":58,"options":59,"answer":43,"analysis":34},1023966,"不宜采用自耦变压器的情况有（）。",[60,62,64,66],{"key":20,"text":61,"correct":22},"发电机升压变压器；",{"key":24,"text":63,"correct":26},"发电厂两种升高电压等级之间的联络变压器；",{"key":28,"text":65,"correct":22},"有110、35、1OkV三个电压等级的降压变压器；",{"key":31,"text":67,"correct":26},"500kV变电所的主变压器。",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":80,"analysis":34},1023967,"在海拔高于1OOOm但低于3000m的地区，以下关于220kV及以下配电装置电器设备选择的说法正确的是（）。",[72,74,76,78],{"key":20,"text":73,"correct":26},"不能选用一般电器产品；",{"key":24,"text":75,"correct":22},"可以选用相同电压等级的高原型电器产品；",{"key":28,"text":77,"correct":22},"可以选用相同电压等级但外绝缘提高一级的电器产品；",{"key":31,"text":79,"correct":22},"可以选用一般电器产品，但应用性能优良的避常器来保护。","BCD",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":93,"analysis":34},1023968,"需三相联动操动机构的断路器是（）。",[85,87,89,91],{"key":20,"text":86,"correct":26},"旁路断路器；",{"key":24,"text":88,"correct":22},"母联断路器；",{"key":28,"text":90,"correct":26},"出线断路器；",{"key":31,"text":92,"correct":22},"大容量发电机出口断路器。","BD",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":106,"analysis":34},1023969,"当断路器的两端为互不联系的电源时，设计中应按（）来校验。",[98,100,102,104],{"key":20,"text":99,"correct":22},"断路器断口间的绝缘水平满足另一侧出现工频反相电压的要求；",{"key":24,"text":101,"correct":22},"在失步下操作时的开断电流不超过断路器的額定反相开断性能的要求；",{"key":28,"text":103,"correct":22},"断路器同极断口间的公称爬电比距与对地公称爬电比距之比一般取为1.15~1.3；",{"key":31,"text":105,"correct":26},"当断路器起联络作用时，其断口的公称爬电比距与对地公称爬电比距之比一般不低于1.2。","ABC",{"id":108,"libraryId":5,"type":15,"typeLabel":16,"stem":109,"options":110,"answer":33,"analysis":34},1023970,"选择导体的一般原则是（）。",[111,113,115,117],{"key":20,"text":112,"correct":22},"以达到技术先进、安全可靠、经济适用、符合国情的要求；",{"key":24,"text":114,"correct":26},"应满足正常运行、检修、短路及过电压情况下的要求，考虑近景发展；",{"key":28,"text":116,"correct":22},"应按当地环境条件校核；",{"key":31,"text":118,"correct":22},"应与整个工程的建设标准协调一致。",{"id":120,"libraryId":5,"type":15,"typeLabel":16,"stem":121,"options":122,"answer":131,"analysis":34},1023971,"验算导体的动、热稳定使用的短路电流应（）。",[123,125,127,129],{"key":20,"text":124,"correct":22},"按工程的设计规划容量计算；",{"key":24,"text":126,"correct":22},"考虑电力系统的远景发展规划；",{"key":28,"text":128,"correct":26},"按工程的本期建设容量；",{"key":31,"text":130,"correct":26},"按工程的近期建设容量。","AB",{"id":133,"libraryId":5,"type":15,"typeLabel":16,"stem":134,"options":135,"answer":106,"analysis":34},1023972,"验算导体的短路电流应按（）计算。",[136,138,140,142],{"key":20,"text":137,"correct":22},"可能发生最大短路电流的正常接线方式,",{"key":24,"text":139,"correct":22},"除计算短路电流的衰减时间常数和低压网络的短路电流外，元件的电阻都略去不计；",{"key":28,"text":141,"correct":22},"在电气连接的网络中，应考虑具有反馈作用的异步电动机的影响和电容补偿装里放电电流的影响；",{"key":31,"text":143,"correct":26},"在电气连接的网络中，不考虑具有反馈作用的异步电机的影响。",{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":80,"analysis":34},1023973,"裸导体应按（）等环境条件校验。",[148,150,152,154],{"key":20,"text":149,"correct":26},"热稳定；",{"key":24,"text":151,"correct":22},"日照；",{"key":28,"text":153,"correct":22},"风速；",{"key":31,"text":155,"correct":22},"污秽。",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":43,"analysis":34},1023974,"下列场所可选用锎质材料的硬导体的有()。",[160,162,164,166],{"key":20,"text":161,"correct":22},"持续工作电流大且位置特别狭窄的发电机、变压器出线端部或采用硬铝导体穿套管有困难时；",{"key":24,"text":163,"correct":26},"污秽对铝腐蚀轻微而对铜有较严重腐蚀的场所；",{"key":28,"text":165,"correct":22},"污秽对铜腐蚀轻微而对铝有较严重腐蚀的场所；",{"key":31,"text":167,"correct":26},"配电装里的母线。",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":131,"analysis":34},1023975,"防腐型铝绞线一般应用的区域和场所有（）。",[172,174,176,178],{"key":20,"text":173,"correct":22},"空气中含盐量较大的地区；",{"key":24,"text":175,"correct":22},"周国气体对铭有明显腐蚀的场所;",{"key":28,"text":177,"correct":26},"I级污秽地区；",{"key":31,"text":179,"correct":26},"采用短托架。",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":106,"analysis":34},1023976,"当计算风速小于6m\u002Fs时，可采取消除微风振动的措施有()。",[184,186,188,190],{"key":20,"text":185,"correct":22},"在管内加装阻尼线；",{"key":24,"text":187,"correct":22},"加装动力消振器；",{"key":28,"text":189,"correct":22},"采用长托架；",{"key":31,"text":191,"correct":26},"上述播施均不对。",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":131,"analysis":34},1023977,"为减少钢构发热，可采取的措施有（）。",[196,198,200,202],{"key":20,"text":197,"correct":22},"当裸导体工作电流大于1500A时，不应使每相导体的支持钢构及导体支持夹板的零件（套管板、双头螺栓、压板、垫板等〉构成闭合磁路；",{"key":24,"text":199,"correct":22},"当裸导体工作电流大于4000A时，其邻近钢构应采取避免构成闭合磁路或装设短路环；",{"key":28,"text":201,"correct":26},"当裸导体工作电流大于1500A时，应使每相导体的支持钢构及导体支持夹板的零件(套管板、双头螺检、压板、垫板等）构成闭合磁路；",{"key":31,"text":203,"correct":26},"当裸导体工作电流大于4000A时，其邻近钢构应构成闭合磁路。",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":33,"analysis":34},1023978,"当选用的封闭母线为非定型产品时，应进行的工作有( )。",[208,210,212,214],{"key":20,"text":209,"correct":22},"导体计算；",{"key":24,"text":211,"correct":26},"外壳振动、应力计算；",{"key":28,"text":213,"correct":22},"绝缘子抗弯计算；",{"key":31,"text":215,"correct":22},"校验固有振动頻率额。",{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":131,"analysis":34},1023979,"封闭母线导体的可固定采用的方式有（）。",[220,222,224,226],{"key":20,"text":221,"correct":22},"三个绝缘子支持方式；",{"key":24,"text":223,"correct":22},"带有弹性固定结构的单个绝缘子支持方式；",{"key":28,"text":225,"correct":26},"一个绝缘子支持方式；",{"key":31,"text":227,"correct":26},"两个绝缘子支持方式。",{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":240,"analysis":34},1023980,"封闭母线的导体采用单个绝缘子支持时，应进行的计算有（）。",[232,234,236,238],{"key":20,"text":233,"correct":22},"母线应力计算；",{"key":24,"text":235,"correct":22},"弹性固定结构应力计算；",{"key":28,"text":237,"correct":26},"绝缘子抗震计算；",{"key":31,"text":239,"correct":22},"热平衡计算。","ABD",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":106,"analysis":34},1023981,"应选用锎芯的电力电缆包括（）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"电机励磁、重要电源、移动式电气设备等需要保持连接具有高可靠性的回路；",{"key":24,"text":248,"correct":22},"振动剧烈、有爆炸危险或对箱有腐蚀等严酷的工作环境；",{"key":28,"text":250,"correct":22},"耐火电缆；",{"key":31,"text":252,"correct":26},"6kV及以上电力电现。",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":106,"analysis":34},1023982,"宜选用铜芯的电力电缆包括（）。",[257,259,261,263],{"key":20,"text":258,"correct":22},"紧靠髙溫设备配里；",{"key":24,"text":260,"correct":22},"安全性要求高的重要公共设施中,",{"key":28,"text":262,"correct":22},"水下敷设当工作电流较大需増多电缆根数时；",{"key":31,"text":264,"correct":26},"1OkV及以上电力电缆。",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":43,"analysis":34},1023983,"直流供电回路电缆芯数选择为(）。",[269,271,273,275],{"key":20,"text":270,"correct":22},"宜采用两芯电缆；",{"key":24,"text":272,"correct":26},"宜采用三芯电缆;",{"key":28,"text":274,"correct":22},"当需要时可采用单芯电缆；",{"key":31,"text":276,"correct":26},"宜采用四芯电缆。",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":131,"analysis":34},1023984,"交流系统中电力电缆缆芯与绝缘屏蔽或金属套之间额定电压的选择，应符合的规定有（）。",[281,283,285,287],{"key":20,"text":282,"correct":22},"中性点直接接地或经低阻抗接地的系统当接地保护动作不超过1mim切除故障时，应按100%的使用回路工作相电压；",{"key":24,"text":284,"correct":22},"对于A項外的供电系统，不宜低于133%的使用回路工作相电压；",{"key":28,"text":286,"correct":26},"在单项接地故陣可能持续5h以上，或发电机回路等安全性要求较高的情况，宜采用173%的使用回路工作相电压；",{"key":31,"text":288,"correct":26},"交流系统中电缆的冲击耐压水平，宜满足系统绝缘配合要求。",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":43,"analysis":34},1023985,"直流输电用电力电缆绝缘水平，应计及的内容包括()。",[293,295,297,299],{"key":20,"text":294,"correct":22},"负荷变化因素；",{"key":24,"text":296,"correct":26},"外部过电压；",{"key":28,"text":298,"correct":22},"内部过电压；",{"key":31,"text":300,"correct":26},"过电压。",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":240,"analysis":34},1023986,"控制电缆额定电压的选择，应计及的内容包括（）。 A.应不低于该回路工作电压、满足可能经受的暂态和工频过电压作用要求;",[305,307,309,311],{"key":20,"text":306,"correct":22},"沿较长高压电缆并行敷设的控制电缆（导引电缆），选用相适合的额定电压；",{"key":24,"text":308,"correct":22},"在220kV及以上高压配电装置敷设的控制电缆宜选用500\u002F1000V,或在有良好屏蔽时可选用450\u002F750V;",{"key":28,"text":310,"correct":26},"除",{"key":31,"text":312,"correct":22},"C项情况外，一般宜选用450\u002F750V，当外部电气干扰影响很小时，可选用较低的額定电压。",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":106,"analysis":34},1023987,"以下环境，应按低温条件和绝缘型类要求，可选用的电缆有()。",[317,319,321,323],{"key":20,"text":318,"correct":22},"油浸紙绝缘电缆；",{"key":24,"text":320,"correct":22},"交联聚乙烯絶缘电缆；",{"key":28,"text":322,"correct":22},"聚乙烯绝缘电缆；",{"key":31,"text":324,"correct":26},"聚氯乙烯绝缘电缆。",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":80,"analysis":34},1023988,"电缆的外护层，应符合的要求有（ ）。",[329,331,333,335],{"key":20,"text":330,"correct":26},"交流单相回路的电力电缆，不得有未经磁性处理的金属带、钢丝铠装；",{"key":24,"text":332,"correct":22},"在潮湿、含化学腐蚀环境或易受水浸泡的电缆，金属套、加强层、铠装上应有挤塑外套，水中电现的粗钢丝铠装尚应有纤维外套；",{"key":28,"text":334,"correct":22},"除低温一20℃以下环境或化学液体浸泡场所，以及有低毒难燃性要求的电纸挤塑外套宜用聚乙烯外，可采用聚氯乙烯外套；",{"key":31,"text":336,"correct":22},"用在有水或化学液体浸泡场所的6~35kV重要性或35kV以上交联聚乙烯电缆，应具有符合使用要求的金属塑料复合阻水层、铅套、铝套或膨胀式阻水带等防水构造。",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":106,"analysis":34},1023989,"直埋敷设电缆的外护层选择，应符合的规定有()。",[341,343,345,347],{"key":20,"text":342,"correct":22},"电现承受较大压力或有机械损伤危險时，应有加强层或钢带铠装；",{"key":24,"text":344,"correct":22},"在流沙层、回填土地等可能出現位移的土壤中，电缆应有钢丝铠装；",{"key":28,"text":346,"correct":22},"白蚁严重危害且塑料电缆未有尼龙套时，可采用金属套或钢带铠装；",{"key":31,"text":348,"correct":26},"直埋教设电缆的外护层均采用带钢带铠装的外护层。",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":80,"analysis":34},1023990,"空气中固定敷设电缆时的外护层选择，应符合的规定有（）。",[353,355,357,359],{"key":20,"text":354,"correct":26},"油浸纸绝缘铅套电缆直接在臂式支架上敷设时，宜具有钢带铠装；",{"key":24,"text":356,"correct":22},"小截面挤塑绝缘电纜直接在臂式支架上教设时，应具有钢带铠装；",{"key":28,"text":358,"correct":22},"在地下客运、商生设施等安全性要求高而鼠害严重的场所，塑料绝缘电缆可具有金属套或钢带铠装；",{"key":31,"text":360,"correct":22},"电缆位于高落差的受力条件需要时，可含有钢丝铠装。",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":240,"analysis":34},1023991,"放射线作用场所的电缆，应选用具有适合耐受放射线辐照强度的防护外套，其类型有（）。",[365,367,369,371],{"key":20,"text":366,"correct":22},"聚氯乙烯；",{"key":24,"text":368,"correct":22},"氯丁橡皮；",{"key":28,"text":370,"correct":26},"交联聚乙烯；",{"key":31,"text":372,"correct":22},"氯磺聚乙烯。",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":106,"analysis":34},1023992,"电缆允许载流量校正系数计入了下列条件中的()。",[377,379,381,383],{"key":20,"text":378,"correct":22},"环境温度差异；",{"key":24,"text":380,"correct":22},"直埋敷设时土壤热阻系数差异；",{"key":28,"text":382,"correct":22},"电缆多根并列的影响；",{"key":31,"text":384,"correct":26},"户外架空敷设的日照影响。",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":28,"analysis":34},1023993,"电缆终端的装置类型选择，应符合的要求有（）。 A.电缆与六氟化破全封闭电器直接相连时，采用象鼻式终端； B.电缆与高压变压器直接相连时，采用封闭式终端；",[389,391,393],{"key":20,"text":390,"correct":26},"电缆与电器相连具有整体式播接功能式，采用可分离式（插接式）终端；",{"key":24,"text":392,"correct":26},"除上述",{"key":28,"text":394,"correct":22},"C项外，电缆与其他电器或导体相连时，采用敞开式终端。",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":80,"analysis":34},1023994,"系统运行中出现于设备绝缘上的过电压一般有（）。",[399,401,403,405],{"key":20,"text":400,"correct":26},"空载过电压；",{"key":24,"text":402,"correct":22},"雷电过电压；",{"key":28,"text":404,"correct":22},"操作过电压；",{"key":31,"text":406,"correct":22},"谐振过电压。",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":33,"analysis":34},1023995,"当雷击避雷针（线）或其他建（构）筑物时，将引起接地网冲击电位增高，对电气设备产生反击过电压，反击过电压的幅值取决于（）。",[411,413,415,417],{"key":20,"text":412,"correct":22},"雷电流幅值；",{"key":24,"text":414,"correct":26},"避声针（线）高度；",{"key":28,"text":416,"correct":22},"地网冲击电阻；",{"key":31,"text":418,"correct":22},"引流点位置和设备充电铒路的时间常数，",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":240,"analysis":34},1023996,"在发电厂和变电所中，防止雷电过电压危害的保护措施主要有（）。",[423,425,427,429],{"key":20,"text":424,"correct":22},"采用避雷针或避雷线进行直击雷保护；",{"key":24,"text":426,"correct":22},"适当配置阀式避雷器，以减少雷电侵入波过电压的危害；",{"key":28,"text":428,"correct":26},"加大接地线的截面，降低接地装里的接地电阻；",{"key":31,"text":430,"correct":22},"按标准要求对采用的雷电侵入波过电压保护方案校验。",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":80,"analysis":34},1023997,"当采用有串联间隙金属氧化物避雷器和碳化桂阀式避雷器时，避雷器的额定电压在一般情况下应符合（）要求。",[435,437,439,441],{"key":20,"text":436,"correct":26},"35、66kV系统中性点避雷器的額定电压不低于0.5Um；",{"key":24,"text":438,"correct":22},"110kV及220kV有效接地系统不低于0.8Um；",{"key":28,"text":440,"correct":22},"35、66kV系统不低于1.OUm;",{"key":31,"text":442,"correct":22},"3~1OkV系统不低于1.1Um。（Um为系统最高电压）",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":455,"analysis":34},1023998,"采用无间隙金属氧化物避雷器作为雷电过电压保护装置时，避雷器的持续运行电压（相对地）对于不同电压及接地系统采用不同值。在下面所列数据中，（)是错误的。",[447,449,451,453],{"key":20,"text":448,"correct":26},"500kV有效接地系统不低于Um\u002F√3（0.59Um）；",{"key":24,"text":450,"correct":22},"220kV有效接地系统不低于Um；",{"key":28,"text":452,"correct":22},"35kV消弧线圈接地系统不低于0.8Um；",{"key":31,"text":454,"correct":26},"1OkV不接地系统不低于1.1Um。","BC",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":93,"analysis":34},1023999,"采用排气式避雷器时，外间隙的最小距离在下列数据中符合要求的是（）。",[460,462,464,466],{"key":20,"text":461,"correct":26},"3kV系统1Omm;",{"key":24,"text":463,"correct":22},"1OkV系统15mm;",{"key":28,"text":465,"correct":26},"20kV系统40mm;",{"key":31,"text":467,"correct":22},"35kV系统1OOmm。",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":80,"analysis":34},1024000,"设备上产生的各种谐振过电压按原因分类可以归纳为（）类型。",[472,474,476,478],{"key":20,"text":473,"correct":26},"工頻电压谱振；",{"key":24,"text":475,"correct":22},"线性谐振；",{"key":28,"text":477,"correct":22},"铁磁谐振；",{"key":31,"text":479,"correct":22},"参数谐振。",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":240,"analysis":34},1024001,"系统中的工频过电压可由以下（）因素引起。",[484,486,488,490],{"key":20,"text":485,"correct":22},"线路空载；",{"key":24,"text":487,"correct":22},"正常送电状态下甩负荷；",{"key":28,"text":489,"correct":26},"发电机自励磁；",{"key":31,"text":491,"correct":22},"线路受端接地故障。",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":106,"analysis":34},1024002,"在并联电抗器的中性点与大地之间串接一接地电抗器（中性点小电抗），其主要作用是（）。",[496,498,500,502],{"key":20,"text":497,"correct":22},"防止以工频基波为主的铁磁谐振过电压；",{"key":24,"text":499,"correct":22},"限制潜供电流；",{"key":28,"text":501,"correct":22},"补偿并联电抗器所接线路的相间电容；",{"key":31,"text":503,"correct":26},"防止产生以2次谱波为主的高次谁波谐振过电压。",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":80,"analysis":34},1024003,"为了避免在110、220kV系统中，由于釆用带有均压电容的断路器开断连接有电磁式电压互感器的空载母线而产生的铁磁谐振过电压，可采取的措施有（）。",[508,510,512,514],{"key":20,"text":509,"correct":26},"增加同一系统中电压互感器中性点接地的数量；",{"key":24,"text":511,"correct":22},"用电容式电压互感器代替电磁式电压互感器；",{"key":28,"text":513,"correct":22},"运行中应避免可能引起谐振的操作方式；",{"key":31,"text":515,"correct":22},"装设专门消除此类铁磁谐振的装置。",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":240,"analysis":34},1024004,"在3~66kV不接地系统或消弧线圏接地系统偶然脱离消弧线圃的部分，当连接有中性点接地的电磁式电压互感器的空载母线时，可能产生铁磁谐振过电压。为限制这类过电压，可采用的措施是（）。",[520,522,524,526],{"key":20,"text":521,"correct":22},"减少同一系统中电压互感器中性点接地的数量；",{"key":24,"text":523,"correct":22},"选用励磁特性饱和点较髙的电磁式电压互感器；",{"key":28,"text":525,"correct":26},"1OkV及以下互感器高压绕组中性点加装避雷器；",{"key":31,"text":527,"correct":22},"在互感器的开口三角形绕组装设电阻或专用消谐装里。",{"id":529,"libraryId":5,"type":15,"typeLabel":16,"stem":530,"options":531,"answer":33,"analysis":34},1024005,"电力系统中操作过电压的幅值和波形与以下（）因素有关。",[532,534,536,538],{"key":20,"text":533,"correct":22},"电网的运行方式；",{"key":24,"text":535,"correct":26},"电网的结构；",{"key":28,"text":537,"correct":22},"电网的故障类型；",{"key":31,"text":539,"correct":22},"操作的对象。",{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":542,"options":543,"answer":455,"analysis":34},1024006,"为了防止3~66kV系统中，在开断并联电容补偿装置（如断路器发生单相或两相重击穿）时产生电容器高压端对地的过电压，采用的措施是（）。",[544,546,548,550],{"key":20,"text":545,"correct":26},"限制并联电容补偿装里容量；",{"key":24,"text":547,"correct":22},"采用开断时不重击穿的断路器；",{"key":28,"text":549,"correct":22},"装设金属氧化物进雷器；",{"key":31,"text":551,"correct":26},"增加并联电容补偿装置电抗器的电抗率。",{"id":553,"libraryId":5,"type":15,"typeLabel":16,"stem":554,"options":555,"answer":564,"analysis":34},1024007,"在开断髙压感应电动机时，因断路器的截流、三相同时开断和髙频重复重击穿等会产生过电压，一般工程中采取的措施有（）。",[556,558,560,562],{"key":20,"text":557,"correct":26},"采用不击穿断路器；",{"key":24,"text":559,"correct":26},"对其操作方式作出限制；",{"key":28,"text":561,"correct":22},"在断路器与电动机之间装设旋转电机金属氧化物避雷器；",{"key":31,"text":563,"correct":22},"在断路器与电动机之间装设阻容吸收装置。","CD",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":80,"analysis":34},1024008,"在装有避雷针、避雷线的构筑物上，下面未采取保护措施的设施严禁架设的有（）。",[569,571,573,575],{"key":20,"text":570,"correct":26},"架空线；",{"key":24,"text":572,"correct":22},"通信线；",{"key":28,"text":574,"correct":22},"广播线；",{"key":31,"text":576,"correct":22},"低压线。",{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":33,"analysis":34},1024009,"对于发电厂、变电所的35kV及以上的电缆进线段，设计中应该根据具体情况采取以下（）保护措施。",[581,583,585,587],{"key":20,"text":582,"correct":22},"在电缆与架空线的连接处应装设阀式避雷器，其接地端应与电缆金属外皮连接；",{"key":24,"text":584,"correct":26},"对三芯电覌，应经金属氧化物电缆护层保护器或保护间歇接地；",{"key":28,"text":586,"correct":22},"如电缆长度超过50m,且断路器在雷季可能经常断路运行，应在电缆末端装设排气式避雷器或阀式避雷器；",{"key":31,"text":588,"correct":22},"连接电缆段的1km架空线路应架设避雷线。",{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":240,"analysis":34},1024010,"具有架空进线的35kV及以上敞开式髙压配电装置中，在以下（）情况下，为了防止来自髙压绕组的雷电波的感应电压危及低压绕组绝缘，应在变压器低压绕组三相出线上装设阀式避雷器.",[593,595,597,599],{"key":20,"text":594,"correct":22},"与架空线路连接的三绕组自耦变压器、变压器（包括与两台电机相连的三绕组变压器）的低压绕组如有开路运行的可能时；",{"key":24,"text":596,"correct":22},"架空线未在2km进线段装设避雷线，与架空线路连接的三绕组自耦变压器、变压器；",{"key":28,"text":598,"correct":26},"采用一个半断路器接线的变压器；",{"key":31,"text":600,"correct":22},"与架空线路连接的发电厂双绕组变压器，有发电机断开由高压侧倒送厂用电的情况，",{"id":602,"libraryId":5,"type":15,"typeLabel":16,"stem":603,"options":604,"answer":106,"analysis":34},1024011,"对于110kV进线有电缆段的GIS变电所，在雷电侵人波过电压保护设计中，一般采取的措施有（）。",[605,607,609,611],{"key":20,"text":606,"correct":22},"在电现段与架空线路的连接处应装设金属氧化物避雷器，其接地端应与电缆的金属外皮连接",{"key":24,"text":608,"correct":22},"对连接电缆段的2km架空线路应架设避雷线；",{"key":28,"text":610,"correct":22},"电缆末端至变压器或GIS—次回路的任何电气部分间的最大电气距离不宜超过130m（参考值）；",{"key":31,"text":612,"correct":26},"对单芯电缆，电缆末端的金属外皮应与GIS管道金属外壳连接并接地。",{"id":614,"libraryId":5,"type":15,"typeLabel":16,"stem":615,"options":616,"answer":240,"analysis":34},1024012,"单机容量为25000~60000kW的直配电机，其雷电过电压保护除按规定接线外，还应采取若干措施，正确的措施是（）。",[617,619,621,623],{"key":20,"text":618,"correct":22},"不与架空线路直接连接，且进线电缆段不应小于150m;",{"key":24,"text":620,"correct":22},"进线电规段应直接埋设在土壤中，以充分利用其金属外皮的分流作用；",{"key":28,"text":622,"correct":26},"进线电缆段如受条件限制不能直接埋设，应将电缆金属外皮集中一点接地；",{"key":31,"text":624,"correct":22},"进线段上的阀式避雷器的接地端，应与电缆的金属外皮和避雷线连在一起接地，接地电阻R不应大于3Ω。",[626,630,633,636,639,642],{"id":627,"name":628,"category":7,"favorite":629},1,"领导干部任职前廉政法规知识测试题",92,{"id":631,"name":632,"category":7,"favorite":627},595,"建筑结构与设备",{"id":634,"name":635,"category":7,"favorite":627},715,"招标采购专业知识与法律法规",{"id":637,"name":638,"category":7,"favorite":627},848,"市政方向-通用基础",{"id":640,"name":641,"category":7,"favorite":8},534,"BIM工程师",{"id":643,"name":641,"category":7,"favorite":8},535]