[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-44":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":634},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,44,50,2670,[13,34,46,58,70,82,94,109,122,135,148,161,174,186,199,212,224,236,249,261,273,285,297,309,321,333,345,357,369,381,393,405,417,429,441,453,465,477,489,501,513,526,538,550,562,574,586,598,610,622],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1023913,1,"单选题","B类电气装置进行接地保护时，可燃液体或气体、供暖系统的金属管道（）用 作保护接地极",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","可以；",false,{"key":24,"text":25,"correct":22},"B","有条件；",{"key":27,"text":28,"correct":22},"C","不可；",{"key":30,"text":31,"correct":32},"D","严禁。",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1023914,"等电位连接主母线的最小截面应不小于装置最大保护线截面的（），并不应小 于 6mm2",[38,40,42,44],{"key":20,"text":39,"correct":22},"1\u002F3；",{"key":24,"text":41,"correct":32},"一半；",{"key":27,"text":43,"correct":22},"2\u002F3;",{"key":30,"text":45,"correct":22},"3\u002F4。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1023915,"消弧线圏接地系统，在正常运行情况下，中性点的长时间电压位移不应超过系统 标称相电压的（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"10%；",{"key":24,"text":53,"correct":32},"15%；",{"key":27,"text":55,"correct":22},"20%；",{"key":30,"text":57,"correct":22},"30%。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":30,"analysis":33},1023916,"应该采取措施防止或减少发电厂和变电所近区的雷击闪络，并在厂、所内适当配 置（）以减少雷电侵入波过电压和危害。",[62,64,66,68],{"key":20,"text":63,"correct":22},"避雷针；",{"key":24,"text":65,"correct":22},"避雷串；",{"key":27,"text":67,"correct":22},"排气式避雷器；",{"key":30,"text":69,"correct":32},"阀式避雷器。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":27,"analysis":33},1023917,"陶式避雷器标称放电电流下的残压，不应大于被保护电气设备（旋转电机除外) 标准雷电冲击全波耐受电压的（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"60%;",{"key":24,"text":77,"correct":22},"66%",{"key":27,"text":79,"correct":32},"71%,",{"key":30,"text":81,"correct":22},"75%。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},1023918,"水电厂主变压器引至高压配电装置的架空线，其安全系数应不小于（）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"4",{"key":24,"text":89,"correct":32},"3.5",{"key":27,"text":91,"correct":22},"3",{"key":30,"text":93,"correct":22},"2.5",{"id":95,"libraryId":5,"type":96,"typeLabel":97,"stem":98,"options":99,"answer":108,"analysis":33},1023919,2,"多选题","对于电力系统，电网中的限流措施有（）。",[100,102,104,106],{"key":20,"text":101,"correct":22},"主网加强，次网闭环运行；",{"key":24,"text":103,"correct":32},"采用全星形的变压器，增加零序阻抗；",{"key":27,"text":105,"correct":32},"增大变压器阻抗；",{"key":30,"text":107,"correct":32},"提高系统电压。","BCD",{"id":110,"libraryId":5,"type":96,"typeLabel":97,"stem":111,"options":112,"answer":121,"analysis":33},1023920,"非对称分量的计算常用于（），",[113,115,117,119],{"key":20,"text":114,"correct":22},"设备热稳定校验；",{"key":24,"text":116,"correct":32},"继电保护用不同故障电流计算；",{"key":27,"text":118,"correct":22},"设备动稳定校验；",{"key":30,"text":120,"correct":32},"接地跨步电压计算。","BD",{"id":123,"libraryId":5,"type":96,"typeLabel":97,"stem":124,"options":125,"answer":134,"analysis":33},1023921,"短路电流计算用于设备选择时应考虑的影响是（）。",[126,128,130,132],{"key":20,"text":127,"correct":32},"异步电机反馈；",{"key":24,"text":129,"correct":22},"电抗器充电；",{"key":27,"text":131,"correct":22},"变压器励磁；",{"key":30,"text":133,"correct":32},"电容器放电。","AD",{"id":136,"libraryId":5,"type":96,"typeLabel":97,"stem":137,"options":138,"answer":147,"analysis":33},1023922,"对多支路非周期分量的计算，一般采用叠加法将时间常数类似的合并。一般，系统时间常数（Ta）较小，而发电机时间常数（Tb）较大，其范围为（）。",[139,141,143,145],{"key":20,"text":140,"correct":22},"Ta≤13；",{"key":24,"text":142,"correct":22},"Ta≤14；",{"key":27,"text":144,"correct":32},"Ta≤15；",{"key":30,"text":146,"correct":32},"15≤Tb 80,","CD",{"id":149,"libraryId":5,"type":96,"typeLabel":97,"stem":150,"options":151,"answer":160,"analysis":33},1023923,"大容量的电容器对短路电流有助增作用，由于其衰减较快，可以不考虑的情况是（）。",[152,154,156,158],{"key":20,"text":153,"correct":32},"短路点在电抗器后；",{"key":24,"text":155,"correct":32},"短路点在主变压器高压側；",{"key":27,"text":157,"correct":22},"对称短路；",{"key":30,"text":159,"correct":32},"与电容器的容量及安装点的Q\u002FJ有关，","ABD",{"id":162,"libraryId":5,"type":96,"typeLabel":97,"stem":163,"options":164,"answer":173,"analysis":33},1023924,"短路电流的热效应的组成为（ ）。",[165,167,169,171],{"key":20,"text":166,"correct":22},"短路电流的全电流在导体中的热效应；",{"key":24,"text":168,"correct":32},"短路电流的周期分量在导体中的热效应；",{"key":27,"text":170,"correct":32},"短路电流的非周期分量在导体中的热效应；",{"key":30,"text":172,"correct":22},"短路电流的起始值在导体中的热效应。","BC",{"id":175,"libraryId":5,"type":96,"typeLabel":97,"stem":176,"options":177,"answer":147,"analysis":33},1023925,"短路电流计算在网络中忽略的参数为（）。",[178,180,182,184],{"key":20,"text":179,"correct":22},"电气设备的电抗；",{"key":24,"text":181,"correct":22},"电气设备的电容；",{"key":27,"text":183,"correct":32},"网络内的电容；",{"key":30,"text":185,"correct":32},"线路电容，",{"id":187,"libraryId":5,"type":96,"typeLabel":97,"stem":188,"options":189,"answer":198,"analysis":33},1023926,"35~110kV变电所限制短路电流一般采用的措施为（）。",[190,192,194,196],{"key":20,"text":191,"correct":32},"在主变压器回路加电抗器；",{"key":24,"text":193,"correct":32},"分裂运行；",{"key":27,"text":195,"correct":22},"采用分裂变压器；",{"key":30,"text":197,"correct":22},"在出线闻路上加电抗器。","AB",{"id":200,"libraryId":5,"type":96,"typeLabel":97,"stem":201,"options":202,"answer":211,"analysis":33},1023927,"短路电流计算采用标么值法，故此时（ ）。",[203,205,207,209],{"key":20,"text":204,"correct":32},"相电压和线电压相等；",{"key":24,"text":206,"correct":22},"相电流和线电流相等；",{"key":27,"text":208,"correct":32},"单相功率和三相功率相等；",{"key":30,"text":210,"correct":32},"标么值电流代替标么值容量。","ACD",{"id":213,"libraryId":5,"type":96,"typeLabel":97,"stem":214,"options":215,"answer":198,"analysis":33},1023928,"对带电抗器的6~1OkV的厂用分支线回路，导体和电器的计算短路点选择在电抗器后的是（）。",[216,218,220,222],{"key":20,"text":217,"correct":32},"分支隔离开关；",{"key":24,"text":219,"correct":32},"分支断路器；",{"key":27,"text":221,"correct":22},"分支隔离开关之前的母线；",{"key":30,"text":223,"correct":22},"分支隔离开关之前的母线套管。",{"id":225,"libraryId":5,"type":96,"typeLabel":97,"stem":226,"options":227,"answer":211,"analysis":33},1023929,"以下等值电源中可以归并的是（）?",[228,230,232,234],{"key":20,"text":229,"correct":32},"同型式发电机，距离相差小；",{"key":24,"text":231,"correct":22},"不同型式发电机，距离相似；",{"key":27,"text":233,"correct":32},"不同型式发电机，距离较远；",{"key":30,"text":235,"correct":32},"同接于短路点上的发电机。",{"id":237,"libraryId":5,"type":96,"typeLabel":97,"stem":238,"options":239,"answer":248,"analysis":33},1023930,"短路电流计算中，下列假设条件正确的是（）。",[240,242,244,246],{"key":20,"text":241,"correct":32},"三相系统对称运行；",{"key":24,"text":243,"correct":32},"各电源的电动势相位相同；",{"key":27,"text":245,"correct":32},"各元件的磁路不饱和；",{"key":30,"text":247,"correct":22},"同步电机不设自动助磁装置。","ABC",{"id":250,"libraryId":5,"type":96,"typeLabel":97,"stem":251,"options":252,"answer":211,"analysis":33},1023931,"正序阻抗和负序阻抗相等的元件是（）。",[253,255,257,259],{"key":20,"text":254,"correct":32},"变压器；",{"key":24,"text":256,"correct":22},"发电机；",{"key":27,"text":258,"correct":32},"电抗器；",{"key":30,"text":260,"correct":32},"架空线路。",{"id":262,"libraryId":5,"type":96,"typeLabel":97,"stem":263,"options":264,"answer":248,"analysis":33},1023932,"短路电流的计箅结果主要用于（）。",[265,267,269,271],{"key":20,"text":266,"correct":32},"电气主接线比选；",{"key":24,"text":268,"correct":32},"选择电器和导体；",{"key":27,"text":270,"correct":32},"确定中性点接地方式；",{"key":30,"text":272,"correct":22},"电气设备布里。",{"id":274,"libraryId":5,"type":96,"typeLabel":97,"stem":275,"options":276,"answer":248,"analysis":33},1023933,"变压器并列运行的条件是（）。",[277,279,281,283],{"key":20,"text":278,"correct":32},"接线组别相同；",{"key":24,"text":280,"correct":32},"变比相同；",{"key":27,"text":282,"correct":32},"短路电压相等；",{"key":30,"text":284,"correct":22},"容量相等。",{"id":286,"libraryId":5,"type":96,"typeLabel":97,"stem":287,"options":288,"answer":211,"analysis":33},1023934,"用于6~1OkV回路的负荷开关与熔断器组合使用时，要求加装分励脱扣器的条件是（）。",[289,291,293,295],{"key":20,"text":290,"correct":32},"用于800kVA及以上的油浸变压器回路时；",{"key":24,"text":292,"correct":22},"用于400kVA及以上的干式变压器回路时；",{"key":27,"text":294,"correct":32},"当干式变压器设置超温跳闸保护时；",{"key":30,"text":296,"correct":32},"当带外壳干式变压器设置误带电开门跳闸保护时。",{"id":298,"libraryId":5,"type":96,"typeLabel":97,"stem":299,"options":300,"answer":211,"analysis":33},1023935,"对330kV及以上悬式绝缘子型式及毎串片数的选择，以下说法正确的有（）.",[301,303,305,307],{"key":20,"text":302,"correct":32},"应按额定电压和爬电比距选择；",{"key":24,"text":304,"correct":22},"应按内过电压倍数和绝缘于串的工頻湿闪电压选择；",{"key":27,"text":306,"correct":32},"应按避雷器的操作过电压保护水平和绝缘子串正极性操作冲击50%放电电压选择；",{"key":30,"text":308,"correct":32},"应按雷电过电压选择。",{"id":310,"libraryId":5,"type":96,"typeLabel":97,"stem":311,"options":312,"answer":248,"analysis":33},1023936,"在技术经济合理时，全封闭组合电器宜用于11OkV及以上电网的（ ）。",[313,315,317,319],{"key":20,"text":314,"correct":32},"重污秽地区；",{"key":24,"text":316,"correct":32},"布里场所特别狭窄的水电厂；",{"key":27,"text":318,"correct":32},"地下变电所；",{"key":30,"text":320,"correct":22},"大城市郊区变电所。",{"id":322,"libraryId":5,"type":96,"typeLabel":97,"stem":323,"options":324,"answer":248,"analysis":33},1023937,"保护35kV及以下电力变压器的高压熔断器熔体，在（）不应误溶断.",[325,327,329,331],{"key":20,"text":326,"correct":32},"当这体内通过电力变压器回路最大工作电流时；",{"key":24,"text":328,"correct":32},"当熔体内通过电力变压器的励磁涌流时；",{"key":27,"text":330,"correct":32},"当熔体内通过保护范围以外的短路电流时；",{"key":30,"text":332,"correct":22},"当熔体内通过电力变压器低压侧出口的单相接地短路电流时。",{"id":334,"libraryId":5,"type":96,"typeLabel":97,"stem":335,"options":336,"answer":211,"analysis":33},1023938,"以下关于主变压器冷却方式的说法，正确的是（）。",[337,339,341,343],{"key":20,"text":338,"correct":32},"小容量变压器一般采用自然冷却；",{"key":24,"text":340,"correct":22},"残迫导向油循环风冷却方式与弦迫油循环水冷却方式相比具有更高的冷却效率；",{"key":27,"text":342,"correct":32},"自然油循环风冷却方式的代号是ONAF；",{"key":30,"text":344,"correct":32},"弦迫油循环风冷却系统应采用两路独立电源供电，并能实现自投，",{"id":346,"libraryId":5,"type":96,"typeLabel":97,"stem":347,"options":348,"answer":147,"analysis":33},1023939,"以下关于断路器额定值的说法，正确的是（）。",[349,351,353,355],{"key":20,"text":350,"correct":22},"額定短珞开断电流由交流分量有效值和直流分量绝对值两个值来表征；",{"key":24,"text":352,"correct":22},"用于500kV配电装里的高压断路器，其額定操作顺序应选择O~0.3s~C0~180s~CO；",{"key":27,"text":354,"correct":32},"额度冷值耐受电流等于额定短路关合电流；",{"key":30,"text":356,"correct":32},"额度短时耐受电流等于额定短路开断电流。",{"id":358,"libraryId":5,"type":96,"typeLabel":97,"stem":359,"options":360,"answer":121,"analysis":33},1023940,"关于并联电抗器的选择，以下说法正确的有（）。",[361,363,365,367],{"key":20,"text":362,"correct":22},"330~500kV并联电抗器的容量和台数，应首先满足无功平衡的需要，并结合限制潜供电流、限制工频过电压、防止自励磁等方面的要求；",{"key":24,"text":364,"correct":32},"高压并联电抗器可采用单相式或三相式；",{"key":27,"text":366,"correct":22},"330~500kV并联电抗器的中性点一般采用直接接地；",{"key":30,"text":368,"correct":32},"高压并联电抗器回路一般不装设断路器或负荷开关。",{"id":370,"libraryId":5,"type":96,"typeLabel":97,"stem":371,"options":372,"answer":198,"analysis":33},1023941,"关于电流互感器的配置，以下说法正确的有（ ）。",[373,375,377,379],{"key":20,"text":374,"correct":32},"对中性点非有效接地系统，电流互感器可按两相或三相配里；",{"key":24,"text":376,"correct":32},"一个厂站内的电流互感器额定二次电流允许同时采用1A和5A；",{"key":27,"text":378,"correct":22},"一组电流互感器一般具有多个二次绕组，各个二次绕组的变比应相同；",{"key":30,"text":380,"correct":22},"测量用电流互感器必须规定仪表保安系数（FS）,以避免故陣时一次回路短时通过大短路电流而损坏測量仪表。",{"id":382,"libraryId":5,"type":96,"typeLabel":97,"stem":383,"options":384,"answer":198,"analysis":33},1023942,"关于主设备选择的一般原则，下列各项说法正确的是（）。",[385,387,389,391],{"key":20,"text":386,"correct":32},"应力求技术先进、安全适用、经济合理，满足正常运行、检修、短路和过电压情况下的要求，并考虑远景发展；",{"key":24,"text":388,"correct":32},"应按当地环境条件校核，与整个工程的建设标准协调一致；",{"key":27,"text":390,"correct":22},"应根据品种实际需要选用导体及其他设备，以免造成浪费；",{"key":30,"text":392,"correct":22},"使用新技术、新产品。",{"id":394,"libraryId":5,"type":96,"typeLabel":97,"stem":395,"options":396,"answer":198,"analysis":33},1023943,"对各种髙压电器的选择最通用和最基本的条件是（）。",[397,399,401,403],{"key":20,"text":398,"correct":32},"按额定电压选用；",{"key":24,"text":400,"correct":32},"按机械荷载、绝缘水平选用；",{"key":27,"text":402,"correct":22},"按教定电流、額定容量和额定开断电流选用；",{"key":30,"text":404,"correct":22},"要考虑短路稳定性。",{"id":406,"libraryId":5,"type":96,"typeLabel":97,"stem":407,"options":408,"answer":147,"analysis":33},1023944,"下面关于高原电器环境使用条件的叙述正确的是（）。",[409,411,413,415],{"key":20,"text":410,"correct":22},"海拔高度为1OOOm,最湿月平均最大空气相对湿度20℃时90%；",{"key":24,"text":412,"correct":22},"海拔高度为2000m，最湿月平均最大空气相对湿度18℃时90%；",{"key":27,"text":414,"correct":32},"海拔高度为2500m,最湿月平均最大空气相对湿度12.5℃时90%；",{"key":30,"text":416,"correct":32},"海拔高度为4000m，最湿月平均最大空气相对湿度5℃时90%。",{"id":418,"libraryId":5,"type":96,"typeLabel":97,"stem":419,"options":420,"answer":108,"analysis":33},1023945,"下面关于条件和污秽等级的叙述正确的是（）。",[421,423,425,427],{"key":20,"text":422,"correct":22},"工业区和人口低密集区，在污闪季节中干燥少雾（含毛毛雨）或雨量较多时，为0级污秽等级；",{"key":24,"text":424,"correct":32},"轻盆城和炉烟污秽地区，在污闪季节中潮湿多雾（含毛毛雨）但雨量较少时，为II级污秽等级；",{"key":27,"text":426,"correct":32},"重雾和重盐碱地区，工业人口密度较大地区，为III级污秽等级；",{"key":30,"text":428,"correct":32},"大气特别严重污染地区，离化学污源和炉烟污秽300m以内地区，为IV级污秽等级。",{"id":430,"libraryId":5,"type":96,"typeLabel":97,"stem":431,"options":432,"answer":211,"analysis":33},1023946,"对于高海拔地区电器的选用，下面各项说法中正确的是（）。",[433,435,437,439],{"key":20,"text":434,"correct":32},"在高原地区，由于气温降低足够补偿海拔对温升的影响，因而在实际使用争其额定电流值可与一般地区相同；",{"key":24,"text":436,"correct":22},"对安装在海拔高度超过3000m地区的电器外绝缘一般应予加强；",{"key":27,"text":438,"correct":32},"在海拔3000m以下地区，220kV及以下配电装里也可以选用性能优良的避雷器未保护一般电器的外绝缘；",{"key":30,"text":440,"correct":32},"由于现有11OkV及以下大多数电器的外绝缘有一定裕度，故可使用在海拔2OOOm以下的地区。",{"id":442,"libraryId":5,"type":96,"typeLabel":97,"stem":443,"options":444,"answer":160,"analysis":33},1023947,"选择电器时关于防震要求的阐述正确的是（）。",[445,447,449,451],{"key":20,"text":446,"correct":32},"选择电器时，应根据当地的地震烈庋选用能够满足地震要求的产品；",{"key":24,"text":448,"correct":32},"地震基本烈度为7度及以下地区的电器可不另釆取防震措施；",{"key":27,"text":450,"correct":22},"在地震烈度9度以上地区，电器应能承受相应地震烈度的地震力，在安装时，应考虑支架对地震力的放大作用；",{"key":30,"text":452,"correct":32},"电器的辅助设备应具有与主设备相同的抗震能力。",{"id":454,"libraryId":5,"type":96,"typeLabel":97,"stem":455,"options":456,"answer":248,"analysis":33},1023948,"选择发电机组时，应主要考虑（）。",[457,459,461,463],{"key":20,"text":458,"correct":32},"发电机的容量，电压等级，绝缘等级；",{"key":24,"text":460,"correct":32},"异常运行工况，冷却方式，氢、油、水系统及发电机本体结构：",{"key":27,"text":462,"correct":32},"励磁系统方式及电网的要求；",{"key":30,"text":464,"correct":22},"发电机搬运尺寸，搬运重量。",{"id":466,"libraryId":5,"type":96,"typeLabel":97,"stem":467,"options":468,"answer":198,"analysis":33},1023949,"进出线在发生故障时，有两台断路器同时断开的是（）。",[469,471,473,475],{"key":20,"text":470,"correct":32},"一台半断路器回路；",{"key":24,"text":472,"correct":32},"多角形接线回路；",{"key":27,"text":474,"correct":22},"桥形接线回路；",{"key":30,"text":476,"correct":22},"双母线接线回路。",{"id":478,"libraryId":5,"type":96,"typeLabel":97,"stem":479,"options":480,"answer":160,"analysis":33},1023950,"下列关于使用断路器的叙述中正确的是（）。",[481,483,485,487],{"key":20,"text":482,"correct":32},"采用封闭母线的大容量机组当需要装设断路器时，应选用发电机专用断路器；",{"key":24,"text":484,"correct":32},"35kV及以上电压级的电容器组宜选用专用断路器；",{"key":27,"text":486,"correct":22},"对110kV及以上的电网，当电力系统稳定要求快速切除故障时，应选用分闸时间不大于0.06s的断路器；",{"key":30,"text":488,"correct":32},"用于为提高系统动稳定装设的电气制动回路中的断路器，其合闸时同不宜大于0.04~0.06s。",{"id":490,"libraryId":5,"type":96,"typeLabel":97,"stem":491,"options":492,"answer":198,"analysis":33},1023951,"断路器开断下列（ ）电容器组时，不应发生重击穿。",[493,495,497,499],{"key":20,"text":494,"correct":32},"1OkV开断电容器组参考容量1000~1OOOOkvar；",{"key":24,"text":496,"correct":32},"35kV开断电容器组参考容量5000~30000kvar；",{"key":27,"text":498,"correct":22},"63kV开断电容器组参考容量9000~35000kvar；",{"key":30,"text":500,"correct":22},"11OkV开断电容器组参考容量15000~50000kvar。",{"id":502,"libraryId":5,"type":96,"typeLabel":97,"stem":503,"options":504,"answer":198,"analysis":33},1023952,"在选择时需要考虑关合性能的高压设备有（）。",[505,507,509,511],{"key":20,"text":506,"correct":32},"高压断路器；",{"key":24,"text":508,"correct":32},"高压负荷开关；",{"key":27,"text":510,"correct":22},"高压隔离开关；",{"key":30,"text":512,"correct":22},"高压熔断器。",{"id":514,"libraryId":5,"type":96,"typeLabel":97,"stem":515,"options":516,"answer":525,"analysis":33},1023953,"关于髙压馆断器的使用条件，下列说法正确的有（）。",[517,519,521,523],{"key":20,"text":518,"correct":32},"限流式高压熔断器保护电器可不校检动稳定和热穗定；",{"key":24,"text":520,"correct":22},"限流式高压熔断器可以使用在工作电压低于其额定电压的电网中；",{"key":27,"text":522,"correct":32},"高压熔断器熔管的额定电流应大于或等于熔体的額定电流；",{"key":30,"text":524,"correct":22},"保护电压互感器的熔断器，需要按額定电压和断流容量选择，还应校验額定电流。","AC",{"id":527,"libraryId":5,"type":96,"typeLabel":97,"stem":528,"options":529,"answer":121,"analysis":33},1023954,"屋外负荷开关的接线端子允许水平静拉力，下列数据正确的是（）。",[530,532,534,536],{"key":20,"text":531,"correct":22},"1OkV及以下、750N；",{"key":24,"text":533,"correct":32},"35~63kV、500N；",{"key":27,"text":535,"correct":22},"11OkV、250N,",{"key":30,"text":537,"correct":32},"220kV、1000N。",{"id":539,"libraryId":5,"type":96,"typeLabel":97,"stem":540,"options":541,"answer":211,"analysis":33},1023955,"关于隔离开关装设位置的说法正确的有（）。",[542,544,546,548],{"key":20,"text":543,"correct":32},"一台半断路器接线中，视发变电工程的具体情况，进出线可装设隔离开关也可不装设隔离开关；",{"key":24,"text":545,"correct":22},"多角形接线的进出线视工程具体情况可装设隔离开关也可不装设隔离开关；",{"key":27,"text":547,"correct":32},"桥形接线中的跨条宜装两组隔离开关串联；",{"key":30,"text":549,"correct":32},"断路器的两侧均应配置隔离开关。",{"id":551,"libraryId":5,"type":96,"typeLabel":97,"stem":552,"options":553,"answer":211,"analysis":33},1023956,"关于配置避雷器的叙述正确的有（ ）。",[554,556,558,560],{"key":20,"text":555,"correct":32},"330~500kV的母线上是否装设避雷器，应根据过电压计算的结果确定；",{"key":24,"text":557,"correct":22},"有旁路母线的旁路母线上，应装设避雷器；",{"key":27,"text":559,"correct":32},"330kV及以上变压器处必须装设避雷器；",{"key":30,"text":561,"correct":32},"三绕组变压器低压侧的一相上宜设里一台避雷器。",{"id":563,"libraryId":5,"type":96,"typeLabel":97,"stem":564,"options":565,"answer":211,"analysis":33},1023957,"下面所列发电机接地电流允许值中正确的是（ ）。 A.发电机额定电压6.3kV，发电机额定容量不大于50kW，接地电流允许值4A；",[566,568,570,572],{"key":20,"text":567,"correct":32},"发电机额定电压10.5kV，发电机额定容量50~1OOkW，接地电流允许值3.5A；",{"key":24,"text":569,"correct":22},"发电机额定电压13. 8~15.75kV，发电机额定容量125~200kW,接地电流允许值之2A(氢冷为2.5",{"key":27,"text":571,"correct":32},"；",{"key":30,"text":573,"correct":32},"发电机额定电压18~20kV，发电机額定容量300kW，接地电流允许值1A。",{"id":575,"libraryId":5,"type":96,"typeLabel":97,"stem":576,"options":577,"answer":211,"analysis":33},1023958,"下面所列各项，支柱绝缘子的选择和校验的项目应包括（）。",[578,580,582,584],{"key":20,"text":579,"correct":32},"电压；",{"key":24,"text":581,"correct":22},"电流；",{"key":27,"text":583,"correct":32},"动稳定；",{"key":30,"text":585,"correct":32},"正常机械荷载。",{"id":587,"libraryId":5,"type":96,"typeLabel":97,"stem":588,"options":589,"answer":160,"analysis":33},1023959,"下列关于SF6封闭式组合电器的断路器的阐述中，正确的有（）。",[590,592,594,596],{"key":20,"text":591,"correct":32},"其断路器断口布置为水平布置时，宜在屋外或对增大配电装里宽度影响不大的场所使用；",{"key":24,"text":593,"correct":32},"其断路器断口布里为垂直布里时，适用于地下开关站；",{"key":27,"text":595,"correct":22},"断路器的操动机构采用电动操动机构；",{"key":30,"text":597,"correct":32},"断路器的操动机构一般釆用液压或弹簧操动机构。",{"id":599,"libraryId":5,"type":96,"typeLabel":97,"stem":600,"options":601,"answer":248,"analysis":33},1023960,"对主设备选择的一般原则，正确的有（）。",[602,604,606,608],{"key":20,"text":603,"correct":32},"应力求技术先进，安全适用，经济合理；",{"key":24,"text":605,"correct":32},"应满足正常运行、检修、短路和过电压情况下的要求，并考虑远景发展；",{"key":27,"text":607,"correct":32},"应按当地环境条件校核；",{"key":30,"text":609,"correct":22},"应选用新产品。",{"id":611,"libraryId":5,"type":96,"typeLabel":97,"stem":612,"options":613,"answer":525,"analysis":33},1023961,"选择户内高压断路器时，必须校验的环境条件有（）。",[614,616,618,620],{"key":20,"text":615,"correct":32},"海拔高度；",{"key":24,"text":617,"correct":22},"日温差；",{"key":27,"text":619,"correct":32},"相对湿度；",{"key":30,"text":621,"correct":22},"污秽。",{"id":623,"libraryId":5,"type":96,"typeLabel":97,"stem":624,"options":625,"answer":108,"analysis":33},1023962,"对发电机励磁系统的要求，以下描述正确的是（）.",[626,628,630,632],{"key":20,"text":627,"correct":22},"励磁系统的强励倍数一般应不小于3，并且应满足所在电力系统的暂态穗定的要求；",{"key":24,"text":629,"correct":32},"大型发电机组如选用旋转励磁，应采用无刷助磁；",{"key":27,"text":631,"correct":32},"助磁系统应以承受发电机出口短路而不应产生有害变形；",{"key":30,"text":633,"correct":32},"大型发电机組选用机端自并时，应综合考虑不同生产厂家的汽轮发电机组及电力系统稳定性的要求。",[635,638,641,644,647,650],{"id":15,"name":636,"category":7,"favorite":637},"领导干部任职前廉政法规知识测试题",92,{"id":639,"name":640,"category":7,"favorite":15},595,"建筑结构与设备",{"id":642,"name":643,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":645,"name":646,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":648,"name":649,"category":7,"favorite":8},534,"BIM工程师",{"id":651,"name":649,"category":7,"favorite":8},535]