[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-43":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":543},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,43,50,2670,[13,34,42,50,58,70,82,94,106,118,130,142,150,162,174,186,198,210,222,230,238,250,262,272,280,288,297,309,317,325,337,349,361,373,384,394,402,410,421,429,437,449,461,473,481,489,501,513,522,531],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},1023863,1,"单选题","大型水电厂在全部机组运行时应不少于（）厂用电电源。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","5个；",false,{"key":24,"text":25,"correct":22},"B","4个；",{"key":27,"text":28,"correct":29},"C","3个；",true,{"key":31,"text":32,"correct":22},"D","2个。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},1023864,"中型水电厂在全部机组运行时应不少于（）厂用电源。 A.5 个； B. 4 个； C 3 个； D.2 个。",[38,39,40,41],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":31,"analysis":33},1023865,"水电厂屋外配电装置场地四周应设置高（）的实体围墙，如配电装置位于厂区围 墙内，可只设不低于1. 5m的围栏。 A. 1. 5~1. 8m； B. 1.8?2. 0m; C, 2.0?2.2m; D. 2. 2?2. 5m。",[46,47,48,49],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":51,"libraryId":5,"type":15,"typeLabel":16,"stem":52,"options":53,"answer":20,"analysis":33},1023866,"从水电厂的（）kV及以上电压级的高压母线上引接厂用电电源必须通过技术经 济比较论证确定。 A.110; B 35； C. 10; D. 220。",[54,55,56,57],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},1023867,"铝芯绝缘导线或电缆的连接与封端应采用压接、熔焊或钎焊，当与电气设备（照明 灯具除外）连接时，应采用（〉接头。",[62,64,66,68],{"key":20,"text":63,"correct":22},"压接；",{"key":24,"text":65,"correct":22},"熔焊；",{"key":27,"text":67,"correct":29},"适当的过渡；",{"key":31,"text":69,"correct":22},"焊。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},1023868,"在爆炸性气体环境1区内，电缆线路严禁或不应有（）接头。",[74,76,78,80],{"key":20,"text":75,"correct":22},"两个以上；",{"key":24,"text":77,"correct":22},"三个以上；",{"key":27,"text":79,"correct":22},"四个以上;",{"key":31,"text":81,"correct":29},"中间。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},1023869,"在爆炸性气体环境1区、2区内，当电气设备本身接头部件无（）时，导体引向 电气设备接头部件前的管段处。",[86,88,90,92],{"key":20,"text":87,"correct":22},"隔离;",{"key":24,"text":89,"correct":22},"密封；",{"key":27,"text":91,"correct":22},"填充包装；",{"key":31,"text":93,"correct":29},"隔离密封。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},1023870,"( )kV及以下架空线路严禁跨越火灾危险区域。",[98,100,102,104],{"key":20,"text":99,"correct":29},"10；",{"key":24,"text":101,"correct":22},"35;",{"key":27,"text":103,"correct":22},"110；",{"key":31,"text":105,"correct":22},"220。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},1023871,"当机组采用计算机监控时，应设置（）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"直流不停电电源；",{"key":24,"text":113,"correct":29},"交流不停电电源；",{"key":27,"text":115,"correct":22},"C双向回路电源；",{"key":31,"text":117,"correct":22},"保安电源。",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},1023872,"发电厂应采取措施防止或减少近区雷击闪络。未沿全线架设避雷线的35?11OkV 架空线路，应在（）的进线段架设避雷线。",[122,124,126,128],{"key":20,"text":123,"correct":29},"1?2km;",{"key":24,"text":125,"correct":22},"1?3km;",{"key":27,"text":127,"correct":22},"1?3. 5km;",{"key":31,"text":129,"correct":22},"1 ?4km。",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":27,"analysis":33},1023873,"进线保护段上的避雷保护角不宜超过20°，最大不应超过（ 〉。",[134,136,138,140],{"key":20,"text":135,"correct":22},"24°；",{"key":24,"text":137,"correct":22},"28°；",{"key":27,"text":139,"correct":29},"30°",{"key":31,"text":141,"correct":22},"32° 。",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":31,"analysis":33},1023874,"在低压电力系统中，全部采用接地保护时，应装设能（）切除接地故障的继电保 护装置。 A.人工； B.遥控； C联动； D.自动。",[146,147,148,149],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":24,"analysis":33},1023875,"应急电源与正常电源之间必须采取防止（）运行的措施.",[154,156,158,160],{"key":20,"text":155,"correct":22},"串联；",{"key":24,"text":157,"correct":29},"并列；",{"key":27,"text":159,"correct":22},"相互影响；",{"key":31,"text":161,"correct":22},"共同。",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":20,"analysis":33},1023876,"民用主体建筑内的附设变电所和车间内变电所的可燃油油浸变压器室，应设置容量 为（）变压器油量的贮油池，",[166,168,170,172],{"key":20,"text":167,"correct":29},"100%；",{"key":24,"text":169,"correct":22},"80%;",{"key":27,"text":171,"correct":22},"75%;",{"key":31,"text":173,"correct":22},"50%。",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":27,"analysis":33},1023877,"当高压及低压配电设备设在同一室内时，且二者有一侧柜顶有裸露的母线，二者之 间净距不应小于（ ）。",[178,180,182,184],{"key":20,"text":179,"correct":22},"0.5m；",{"key":24,"text":181,"correct":22},"1m;",{"key":27,"text":183,"correct":29},"2m;",{"key":31,"text":185,"correct":22},"2.5m。",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":24,"analysis":33},1023878,"安装在生产车间和有人场所的开敞式配电设备，其未遮护的裸带电体距地髙度不应 小于（ ）。",[190,192,194,196],{"key":20,"text":191,"correct":22},"2. 2m；",{"key":24,"text":193,"correct":29},"2. 5m;",{"key":27,"text":195,"correct":22},"2. 8m；",{"key":31,"text":197,"correct":22},"3m。",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":31,"analysis":33},1023879,"隧道、沟、浅槽、竖井、夹层等封闭式电缆通道中，不得含有可能影响环境温升 持续超过（）的供热管道路。",[202,204,206,208],{"key":20,"text":203,"correct":22},"10℃；",{"key":24,"text":205,"correct":22},"8℃；",{"key":27,"text":207,"correct":22},"6℃",{"key":31,"text":209,"correct":29},"5℃。",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":27,"analysis":33},1023880,"海拔高度为1000m以下地区，35kV架空电力线路带电部分与杆塔构件、拉线、脚 钉的最小间隙，在雷电过电压工况下，应满足（）。",[214,216,218,220],{"key":20,"text":215,"correct":22},"0. 6m；",{"key":24,"text":217,"correct":22},"0.5m;",{"key":27,"text":219,"correct":29},"0.45m;",{"key":31,"text":221,"correct":22},"0. 3m。",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":20,"analysis":33},1023881,"3?10kV架空电力线路的引下线与3kV以下线路导线之间的距离不宜小于（）。 A. 0. 2m; B. 0.3m; C 0. 35m； D. 0. 4m。",[226,227,228,229],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":31,"analysis":33},1023882,"在人口稀少地区，35?66kV导线与地面距离在最大计算弧垂情况下，应保持 ( )及以上。 A. 9. 0m； B. 8.0m; C 7. 0m； D. 6. 0m。",[234,235,236,237],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":24,"analysis":33},1023883,"3?10kV的导线与建筑物之间垂直距离，在最大计算弧垂情况下，应保持在 ( )及以上。",[242,244,246,248],{"key":20,"text":243,"correct":22},"4. 0m；",{"key":24,"text":245,"correct":29},"3. 0m;",{"key":27,"text":247,"correct":22},"2. 5m；",{"key":31,"text":249,"correct":22},"2. 0m。",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":27,"analysis":33},1023884,"线路在最大计算风偏情况下，3?10kV的边导线与不在规划范围内的城市建筑物之 间的垂直距离应保持在（）及以上。",[254,256,258,260],{"key":20,"text":255,"correct":22},"4. 0m?",{"key":24,"text":257,"correct":22},"3. 0m；",{"key":27,"text":259,"correct":29},"1. 5m;",{"key":31,"text":261,"correct":22},"1. 0m。",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":27,"analysis":33},1023885,"35?66kV导线与树木（考虑自然生长高度）之间最小垂直距离应保持在（）及 以上。",[266,267,269,270],{"key":20,"text":245,"correct":22},{"key":24,"text":268,"correct":22},"3. 5m；",{"key":27,"text":243,"correct":29},{"key":31,"text":271,"correct":22},"4. 5m。",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":24,"analysis":33},1023886,"3?10kV导线与公园、绿化区或防护林带树木之间的最小距离，在最大计算风偏 情况下，应保持在（）及以上。",[276,277,278,279],{"key":20,"text":247,"correct":22},{"key":24,"text":257,"correct":29},{"key":27,"text":268,"correct":22},{"key":31,"text":271,"correct":22},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":20,"analysis":33},1023887,"35?66kV导线与果树、经济作物或城市灌木之间最小垂直距离，在最大计算弧垂 情况下，应保持在（）及以上。 A. 3. 0m; B. 3. 5m； C 4. 0m; D. 4. 5m。",[284,285,286,287],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":31,"analysis":33},1023888,"3kV以下的导线与街道行道树之间的最小垂直距离，在最大计算弧垂情况下，应 保持在（）及以上。",[292,293,294,296],{"key":20,"text":257,"correct":22},{"key":24,"text":193,"correct":22},{"key":27,"text":295,"correct":22},"2. 0m；",{"key":31,"text":261,"correct":29},{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":24,"analysis":33},1023889,"在海拔高度1000m以下地区，操作过电压及雷电过电压要求悬垂绝缘子串绝缘子片 数，220kV不应少于（ ）片。",[301,303,305,307],{"key":20,"text":302,"correct":22},"10;",{"key":24,"text":304,"correct":29},"13；",{"key":27,"text":306,"correct":22},"15；",{"key":31,"text":308,"correct":22},"16。",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":27,"analysis":33},1023890,"钢筋混凝土杆的铁横担、地线支架、爬梯等铁附件与接地引下线应有可靠的电气连 接。外敷的防雷接地引下线可采用镀锌钢绞线，其截面应按热稳定要求选取，且不应小于 ( )。 A. 40mm2; B. 30mm2; C 25mm2； D. 20mm2。",[313,314,315,316],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":24,"analysis":33},1023891,"钢筋混凝土杆的铁横担、地线支架、爬梯等铁附件与接地引下线应有可靠的电气连 接。接地体引出线的截面不应小于（），并应进行热稳定验算。 A. 60mm2； B. 50mm2 ； C 40mm2 ； D.30mm2。",[321,322,323,324],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":31,"analysis":33},1023892,"送电线路与标准轨距铁路、高速公路及一级公路交叉时，如交叉档距超过（）， 最大弧垂应按导线温度+70℃计算。",[329,331,333,335],{"key":20,"text":330,"correct":22},"120m；",{"key":24,"text":332,"correct":22},"150m;",{"key":27,"text":334,"correct":22},"180;",{"key":31,"text":336,"correct":29},"200m。",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":20,"analysis":33},1023893,"在居民区，110kV导线与地面距离，在最大计算弧垂情况下不应小于（ ）。",[341,343,345,347],{"key":20,"text":342,"correct":29},"7. 0m；",{"key":24,"text":344,"correct":22},"8. 0m",{"key":27,"text":346,"correct":22},"8. 5m",{"key":31,"text":348,"correct":22},"9m。",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":24,"analysis":33},1023894,"在非居民区，220kV导线与地面距离，在最大计算弧垂情况下不应小于（）。",[353,355,357,359],{"key":20,"text":354,"correct":22},"7. 5m；",{"key":24,"text":356,"correct":29},"6. 5m；",{"key":27,"text":358,"correct":22},"6m；",{"key":31,"text":360,"correct":22},"5. 5m",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":27,"analysis":33},1023895,"在交通困难地区，500kV导线与地面距离，在最大计算弧垂情况下不应小于 ()。",[365,367,369,371],{"key":20,"text":366,"correct":22},"10m；",{"key":24,"text":368,"correct":22},"9. 0m;",{"key":27,"text":370,"correct":29},"8. 5m;",{"key":31,"text":372,"correct":22},"8. 0m。",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":24,"analysis":33},1023896,"500kV送电线路不应跨越长期住人的建筑物，在最大计算弧垂情况下，导线与建 筑物之间最小垂直距离不应小于（）。",[377,379,380,382],{"key":20,"text":378,"correct":22},"8. 0m；",{"key":24,"text":368,"correct":29},{"key":27,"text":381,"correct":22},"9.5m；",{"key":31,"text":383,"correct":22},"10. 0m。",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":20,"analysis":33},1023897,"110kV送电线路边导线与建筑物之间的距离，在最大计算风偏情况下，不应小于 ()。",[388,389,391,393],{"key":20,"text":243,"correct":29},{"key":24,"text":390,"correct":22},"4. 5m；",{"key":27,"text":392,"correct":22},"5.0m;",{"key":31,"text":360,"correct":22},{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":31,"analysis":33},1023898,"500kV送电线路边导线与建筑物之间的距离，在最大计算风偏情况下，不应小于()。 A. 5. 0m； B. 7.0m; C 7. 5m D. 8. 5m。",[398,399,400,401],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":24,"analysis":33},1023899,"220kV边导线与不在规划范围内城市建筑物之间水平间距，在无风情况下，不应 小于（ ）。 A. 2. 0m; B. 2. 5m; C 3. 0m D. 3. 5m.",[406,407,408,409],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":31,"analysis":33},1023900,"500kV送电线路与标准轨铁路交叉时，导线到轨顶最小垂直距离不应小于（）。",[414,415,417,419],{"key":20,"text":354,"correct":22},{"key":24,"text":416,"correct":22},"8. 5m；",{"key":27,"text":418,"correct":22},"12.0m；",{"key":31,"text":420,"correct":29},"14.0m。",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":24,"analysis":33},1023901,"220kV送电线路与标准轨铁路交叉时，导线到轨顶最小垂直距离不应小于（）。 A. 8. 0m B. 8.5m; C 9. 5m； D. 10.5m。",[425,426,427,428],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":27,"analysis":33},1023902,"屋内配电装置电气设备外绝缘体最低部位距地小于（）时，应装设固定遮栏。 A. 2. 5m B. 2.4m C 2. 3m； D. 2. 2m。",[433,434,435,436],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":20,"analysis":33},1023903,"中性点非直接接地的电力网，应装设能迅速反应接地故障的（）。",[441,443,445,447],{"key":20,"text":442,"correct":29},"信号装置；",{"key":24,"text":444,"correct":22},"保护装置；",{"key":27,"text":446,"correct":22},"延时装里；",{"key":31,"text":448,"correct":22},"绝缘装置。",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":27,"analysis":33},1023904,"发电厂和变电所的屋外配电装置，包括组合导线的母线廊道应装设（）。",[453,455,457,459],{"key":20,"text":454,"correct":22},"阀式避雷器",{"key":24,"text":456,"correct":22},"集中接地装置；",{"key":27,"text":458,"correct":29},"直接雷过电压保护装置；",{"key":31,"text":460,"correct":22},"雷击侵入波过电压保护装置。",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":20,"analysis":33},1023905,"低压线路零线每一重复接地装置的接地电阻不应大于（）。",[465,467,469,471],{"key":20,"text":466,"correct":29},"10Ω",{"key":24,"text":468,"correct":22},"15Ω",{"key":27,"text":470,"correct":22},"20Ω",{"key":31,"text":472,"correct":22},"30Ω",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":27,"analysis":33},1023906,"为防止触电危险，在低压电力网中，严禁利用（）作相线或零线。 A.金属杆塔； B.钢筋混凝土杆塔;C大地； D.接地线。",[477,478,479,480],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":31,"analysis":33},1023907,"X光设备应接地，接地电阻不应大于（）。",[485,486,487,488],{"key":20,"text":472,"correct":22},{"key":24,"text":470,"correct":22},{"key":27,"text":468,"correct":22},{"key":31,"text":466,"correct":29},{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":24,"analysis":33},1023908,"兼作接地体用的直接与大地接触的各种金属构件、金属井管、金属管道、建筑物 基础等称为（）。",[493,495,497,499],{"key":20,"text":494,"correct":22},"接地体；",{"key":24,"text":496,"correct":29},"自然接地体；",{"key":27,"text":498,"correct":22},"接地线；",{"key":31,"text":500,"correct":22},"接地装里",{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":27,"analysis":33},1023909,"地面上水平距离为0.8m的电位差，称为（)",[505,507,509,511],{"key":20,"text":506,"correct":22},"接触电势；",{"key":24,"text":508,"correct":22},"接触电压；",{"key":27,"text":510,"correct":29},"跨步电势；",{"key":31,"text":512,"correct":22},"跨步电压。",{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":20,"analysis":33},1023910,"发电厂和变电所有爆炸危险且爆炸后可能波及发电厂和变电所内主要设备或严重 影响供电的建（构）筑物，防雷电感应的接地电阻不应大于（）。",[517,518,519,520],{"key":20,"text":472,"correct":29},{"key":24,"text":470,"correct":22},{"key":27,"text":466,"correct":22},{"key":31,"text":521,"correct":22},"40Ω",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":24,"analysis":33},1023911,"发电厂的易燃油和天然气设施防静电接地电阻不应大于（）。",[526,528,529,530],{"key":20,"text":527,"correct":22},"40Ω;",{"key":24,"text":472,"correct":29},{"key":27,"text":470,"correct":22},{"key":31,"text":466,"correct":22},{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":27,"analysis":33},1023912,"设计接地网时，应验箅（）和跨步电位差。",[535,537,539,541],{"key":20,"text":536,"correct":22},"接触电势差；",{"key":24,"text":538,"correct":22},"跨步电势差；",{"key":27,"text":540,"correct":29},"接触电位差；",{"key":31,"text":542,"correct":22},"跨步电位差。",[544,547,550,553,556,559],{"id":15,"name":545,"category":7,"favorite":546},"领导干部任职前廉政法规知识测试题",92,{"id":548,"name":549,"category":7,"favorite":15},595,"建筑结构与设备",{"id":551,"name":552,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":554,"name":555,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":557,"name":558,"category":7,"favorite":8},534,"BIM工程师",{"id":560,"name":558,"category":7,"favorite":8},535]