[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-42":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":579},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,42,50,2670,[13,34,46,57,69,81,89,101,113,125,133,143,155,167,179,191,199,211,223,231,243,255,267,275,287,299,311,323,335,347,359,371,383,395,407,415,427,435,447,459,471,479,491,503,515,527,535,547,559,567],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},1023813,1,"单选题","±500kV直流线路与通航河流交叉时，导线至五年一遇洪水位最小距离不应小于 ( ).",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","10. 0m",false,{"key":24,"text":25,"correct":22},"B","10. 5m;",{"key":27,"text":28,"correct":29},"C","12. 0m;",true,{"key":31,"text":32,"correct":22},"D","12. 5m。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},1023814,"绝缘导线及悬挂绝缘导线的绞线的设计安全系数均不应小于（）。",[38,40,42,44],{"key":20,"text":39,"correct":29},"3；",{"key":24,"text":41,"correct":22},"4；",{"key":27,"text":43,"correct":22},"2",{"key":31,"text":45,"correct":22},"5。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1023815,"绝缘支架的安全系数不应小于（），绝缘拉棒的破坏力不小于导线计算拉力的 90%。",[50,51,53,55],{"key":20,"text":41,"correct":22},{"key":24,"text":52,"correct":29},"5；",{"key":27,"text":54,"correct":22},"6;",{"key":31,"text":56,"correct":22},"7。",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":27,"analysis":33},1023816,"跨越通车街道的低压绝缘接户线，导线至路面中心的垂直距离不应小于（）。",[61,63,65,67],{"key":20,"text":62,"correct":22},"5m;",{"key":24,"text":64,"correct":22},"5. 5m；",{"key":27,"text":66,"correct":29},"6. 0m;",{"key":31,"text":68,"correct":22},"7. 0m",{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":31,"analysis":33},1023817,"跨越胡同（里、弄、巷）的低压绝缘接户线，至路面中心的垂直距离不应小于 ( )。",[73,75,77,79],{"key":20,"text":74,"correct":22},"5m",{"key":24,"text":76,"correct":22},"4m；",{"key":27,"text":78,"correct":22},"3. 5m；",{"key":31,"text":80,"correct":29},"3m",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":27,"analysis":33},1023818,"低压绝缘接户线与接户线下方窗户的垂直炬离不应小于（）。 A. 0. 8m； B. 0. 6m C 0.3m D.0. 2m。",[85,86,87,88],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},{"id":90,"libraryId":5,"type":15,"typeLabel":16,"stem":91,"options":92,"answer":24,"analysis":33},1023819,"低压绝缘接户线与接户线上方阳台或窗户的垂直距离不应小于（）。",[93,95,97,99],{"key":20,"text":94,"correct":22},"1. Om；",{"key":24,"text":96,"correct":29},"0.8m；",{"key":27,"text":98,"correct":22},"0.6m;",{"key":31,"text":100,"correct":22},"O. 5m。",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":20,"analysis":33},1023820,"低压绝缘接户线与弱电线路交叉时，低压绝缘接户线在弱电线路上方情况下，其距 离不应小于（）。",[105,107,109,111],{"key":20,"text":106,"correct":29},"0. 6m；",{"key":24,"text":108,"correct":22},"0. 5m",{"key":27,"text":110,"correct":22},"0. 4m；",{"key":31,"text":112,"correct":22},"0. 3m。",{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":115,"options":116,"answer":27,"analysis":33},1023821,"绝缘配电线路与甲类火灾危险性的生产厂房、甲类物品库房、易燃、易爆材料堆场 以及可燃或易燃、易爆液（气）体贮罐的防火间距，不应小于杆塔髙度的（）倍。",[117,119,121,123],{"key":20,"text":118,"correct":22},"1；",{"key":24,"text":120,"correct":22},"1.2；",{"key":27,"text":122,"correct":29},"1.5；",{"key":31,"text":124,"correct":22},"2。",{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":127,"options":128,"answer":31,"analysis":33},1023822,"柱上变压器台距地面高度不应小于（ ）。 A. 3. 5m B. 3. 2m； C 3.0m D. 2. 5m。",[129,130,131,132],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":24,"analysis":33},1023823,"高压接户线受电端的对地面距离不应小于（）。",[137,139,140,141],{"key":20,"text":138,"correct":22},"5m；",{"key":24,"text":76,"correct":29},{"key":27,"text":78,"correct":22},{"key":31,"text":142,"correct":22},"3m。",{"id":144,"libraryId":5,"type":15,"typeLabel":16,"stem":145,"options":146,"answer":27,"analysis":33},1023824,"电缆与热力管道、热力设备之间的净距，平行时不应小于（）。",[147,149,151,153],{"key":20,"text":148,"correct":22},"1. 5m；",{"key":24,"text":150,"correct":22},"1. 2m",{"key":27,"text":152,"correct":29},"1. Om;",{"key":31,"text":154,"correct":22},"0.8m.",{"id":156,"libraryId":5,"type":15,"typeLabel":16,"stem":157,"options":158,"answer":31,"analysis":33},1023825,"住宅电器安装完毕，调整试验合格后,宜对调整机构进行（）处理。",[159,161,163,165],{"key":20,"text":160,"correct":22},"联销；",{"key":24,"text":162,"correct":22},"封闭；",{"key":27,"text":164,"correct":22},"标识；",{"key":31,"text":166,"correct":29},"封锁。",{"id":168,"libraryId":5,"type":15,"typeLabel":16,"stem":169,"options":170,"answer":20,"analysis":33},1023826,"事故排风机的按钮，应单独安装在便于操作的位置，且应有（）。",[171,173,175,177],{"key":20,"text":172,"correct":29},"特殊标志；",{"key":24,"text":174,"correct":22},"明显标志",{"key":27,"text":176,"correct":22},"安全标志",{"key":31,"text":178,"correct":22},"操作标志。",{"id":180,"libraryId":5,"type":15,"typeLabel":16,"stem":181,"options":182,"answer":24,"analysis":33},1023827,"微压继电器应装设在风压、气压最低点的出口处。运行中的电气设备及通风、充气 系统内的风压、气压值不应低于产品技术条件中规定的最低所需压力值，当低于规定值时， 微压继电器应可靠动作，在爆炸性气体环境为I区时.，还应能可靠地（）。",[183,185,187,189],{"key":20,"text":184,"correct":22},"发出信号",{"key":24,"text":186,"correct":29},"切断电源；",{"key":27,"text":188,"correct":22},"发出警告；",{"key":31,"text":190,"correct":22},"安全维护。",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":31,"analysis":33},1023828,"爆炸危险环境内采用的低压电缆和绝缘导线，其额定电压必须高于线路的工作电压 且不得低于（），绝缘导线必须敷设在钢管内。 A. 110kV B. 220V； C 380V； D. 500V。",[195,196,197,198],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":24,"analysis":33},1023829,"电气工作中性线绝缘层的额定电压（），并应在同一护套或钢管内敷设。",[203,205,207,209],{"key":20,"text":204,"correct":22},"应比相线电压略高；",{"key":24,"text":206,"correct":29},"应与相线电压相同；",{"key":27,"text":208,"correct":22},"应比相线电压略低；",{"key":31,"text":210,"correct":22},"应与相线电压匹配。",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":27,"analysis":33},1023830,"电气开关和正常运行产生火花或外壳表面温度较高的电气设备，应远离可燃物质的 存放点，其最小距离不应小于（）。",[215,217,219,221],{"key":20,"text":216,"correct":22},"2m；",{"key":24,"text":218,"correct":22},"2.5m；",{"key":27,"text":220,"correct":29},"3m;",{"key":31,"text":222,"correct":22},"4m。",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":24,"analysis":33},1023831,"10kV及以下架空线路严禁跨越火灾危险环境，架空线路与火灾危险环境的水平距 离不应小于杆塔高度的（）。 A.1倍； B. 1.5倍； C 2倍； D.3倍。",[227,228,229,230],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":20,"analysis":33},1023832,"在试验和推广新技术、新工艺、新设备、新材料的同时,必须制定相应的安全技术 措施，经（）批准后执行。",[235,237,239,241],{"key":20,"text":236,"correct":29},"总工程师；",{"key":24,"text":238,"correct":22},"项目经理；",{"key":27,"text":240,"correct":22},"安全主管；",{"key":31,"text":242,"correct":22},"监理。",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":24,"analysis":33},1023833,"在易燃、易爆区周围动用明火，必须办理（），经有关部门批准，并采取相关措 施方可进行。",[247,249,251,253],{"key":20,"text":248,"correct":22},"监护手续；",{"key":24,"text":250,"correct":29},"动火工作票；",{"key":27,"text":252,"correct":22},"监理手续；",{"key":31,"text":254,"correct":22},"消防手续",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":20,"analysis":33},1023834,"330kV和500kV线路应沿全线架设（ ），但少雷区除外。",[259,261,263,265],{"key":20,"text":260,"correct":29},"双避雷线；",{"key":24,"text":262,"correct":22},"单避雷线",{"key":27,"text":264,"correct":22},"避雷针",{"key":31,"text":266,"correct":22},"避雷串。",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":31,"analysis":33},1023835,"在（）电压等级的正在运行的变电所构架上作业，必须采取防静电感应措施， A. 110、220kV； B 220、330kV； C 330kV D. 330、500kV。",[271,272,273,274],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":277,"options":278,"answer":31,"analysis":33},1023836,"严禁采用预约（）时间的方式在线路或设备上进行任何工作",[279,281,283,285],{"key":20,"text":280,"correct":22},"停电；",{"key":24,"text":282,"correct":22},"送电；",{"key":27,"text":284,"correct":22},"发送电；",{"key":31,"text":286,"correct":29},"停送电。",{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":20,"analysis":33},1023837,"对新人厂人员必须进行（），经考试合格后持证上岗。",[291,293,295,297],{"key":20,"text":292,"correct":29},"三级安全教育培训；",{"key":24,"text":294,"correct":22},"上岗安全教育培训",{"key":27,"text":296,"correct":22},"技术安全教育培训；",{"key":31,"text":298,"correct":22},"岗位安全教育培训。",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":24,"analysis":33},1023838,"油量为2500kg及以上的屋外油浸变电器，在电压等级220kV及以上时，它们之间 的最小间距不小于（）。",[303,305,307,309],{"key":20,"text":304,"correct":22},"8m；",{"key":24,"text":306,"correct":29},"10m；",{"key":27,"text":308,"correct":22},"12m 5",{"key":31,"text":310,"correct":22},"15m。",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":24,"analysis":33},1023839,"屋外单台总油量（）以上电气设备,应设置贮油或挡油设施。",[315,317,319,321],{"key":20,"text":316,"correct":22},"2500kg",{"key":24,"text":318,"correct":29},"1000kg；",{"key":27,"text":320,"correct":22},"600kg；",{"key":31,"text":322,"correct":22},"100kg。",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":31,"analysis":33},1023840,"架空敷设的电缆与热力管路应保持足够的距离，控制电缆、动力电缆与热力管道平 行时，两者距离分别应不小于（）。",[327,329,331,333],{"key":20,"text":328,"correct":22},"0.2m 及 0. 3m",{"key":24,"text":330,"correct":22},"0. 25m 及 0. 3m;",{"key":27,"text":332,"correct":22},"0.2m 及 0.5m;",{"key":31,"text":334,"correct":29},"0.5m 及 1.0m。",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":20,"analysis":33},1023841,"架空敷设的控制电缆、动力电缆与热力管道交叉时，两者距离分别不应小于 ()，当不能满足时，应采取有效的隔热防火措施。",[339,341,343,345],{"key":20,"text":340,"correct":29},"0.25m及0.5m;",{"key":24,"text":342,"correct":22},"0.3m及 0.6m;",{"key":27,"text":344,"correct":22},"O. 5m及0.6m;",{"key":31,"text":346,"correct":22},"O. 5m及 1.0m,",{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":20,"analysis":33},1023842,"移动式电气设备等需经常弯移或有较高柔软性要求的回路，应使用（）电缆。",[351,353,355,357],{"key":20,"text":352,"correct":29},"橡皮绝缘；",{"key":24,"text":354,"correct":22},"塑料绝缘；",{"key":27,"text":356,"correct":22},"铜芯；",{"key":31,"text":358,"correct":22},"铝芯。",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":31,"analysis":33},1023843,"放射性作用场所，应按绝缘型类要求选用交联聚乙烯、（）等耐射线辐照强度的 电缆。",[363,365,367,369],{"key":20,"text":364,"correct":22},"普通聚乙烯",{"key":24,"text":366,"correct":22},"耐热聚氯乙稀；",{"key":27,"text":368,"correct":22},"辐照式交联聚乙烯",{"key":31,"text":370,"correct":29},"乙丙橡皮绝缘。",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":20,"analysis":33},1023844,"敷设于保护管中的电缆，应具有（）。",[375,377,379,381],{"key":20,"text":376,"correct":29},"挤塑外套；",{"key":24,"text":378,"correct":22},"橡胶外套；",{"key":27,"text":380,"correct":22},"铝皮外套；",{"key":31,"text":382,"correct":22},"钢丝铠装。",{"id":384,"libraryId":5,"type":15,"typeLabel":16,"stem":385,"options":386,"answer":27,"analysis":33},1023845,"在地震烈度7度及以上地区，电缆、接地线等应采取防止地震时被（）的措施。",[387,389,391,393],{"key":20,"text":388,"correct":22},"震落；",{"key":24,"text":390,"correct":22},"拉伸；",{"key":27,"text":392,"correct":29},"切断；",{"key":31,"text":394,"correct":22},"掩埋。",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":27,"analysis":33},1023846,"在地震烈度7度及以上地区，调相机、空气压缩机和柴油发电机附近应设置 ( ).",[399,401,403,405],{"key":20,"text":400,"correct":22},"消火栓；",{"key":24,"text":402,"correct":22},"干粉灭火器",{"key":27,"text":404,"correct":29},"补楼装置；",{"key":31,"text":406,"correct":22},"抗震保护装里。",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":24,"analysis":33},1023847,"在3?110kV装有管型避雷器的线路，保护装置的动作时间不应大于（）。 A. 0.10s; B.0. 08s CO. 06s； D. 0.05s。",[411,412,413,414],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":24,"analysis":33},1023848,"保护装置采用的电流互感器及中间电流互感器的稳态比误差不应大于（）。",[419,421,423,425],{"key":20,"text":420,"correct":22},"15%；",{"key":24,"text":422,"correct":29},"10%;",{"key":27,"text":424,"correct":22},"8%",{"key":31,"text":426,"correct":22},"5%。",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":20,"analysis":33},1023849,"0. 8MVA及以上的油浸式变压器和0. 4MVA及以上的车间内油浸式变压器，均应 装设（）。 A.瓦斯保护； B.接地保护； C灭火装置； D.零序电流保护。",[431,432,433,434],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":27,"analysis":33},1023850,"对单相接地故障，（3kV及以上电动机的保护）当接地电流大于（）时，应装设 有选择性的单相接地保护。",[439,441,443,445],{"key":20,"text":440,"correct":22},"10A；",{"key":24,"text":442,"correct":22},"8A；",{"key":27,"text":444,"correct":29},"5A；",{"key":31,"text":446,"correct":22},"3A。",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":31,"analysis":33},1023851,"自动重合闸装置在装置的某些元件损坏以及新电器触点粘住或拒动等情况下，均不 应使断路器（）。",[451,453,455,457],{"key":20,"text":452,"correct":22},"再次重合；",{"key":24,"text":454,"correct":22},"反复重合；",{"key":27,"text":456,"correct":22},"自动重合；",{"key":31,"text":458,"correct":29},"多次重合。",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":24,"analysis":33},1023852,"置于屋内的干式变压器之间的距离不应小于（），并应满足巡视维修的需求。",[463,465,467,469],{"key":20,"text":464,"correct":22},"1. 2m；",{"key":24,"text":466,"correct":29},"1. Om",{"key":27,"text":468,"correct":22},"0. 9m;",{"key":31,"text":470,"correct":22},"0. 8m",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":31,"analysis":33},1023853,"配电装置电气设备网状遮栏高度不应小于（ ），网孔不应大于40mmX40mm。 A. 2.0m; B.1. 9m C 1.8m D. 1. 7m",[475,476,477,478],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":24,"analysis":33},1023854,"在电气连接的网络中，应考虑具有（）作用的异步电动机的彩响和电容补偿装置 放电电流的影响。",[483,485,487,489],{"key":20,"text":484,"correct":22},"回流",{"key":24,"text":486,"correct":29},"反馈；",{"key":27,"text":488,"correct":22},"防爆；",{"key":31,"text":490,"correct":22},"联锁。",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":31,"analysis":33},1023855,"燃煤电厂主厂房电缆采用架空托架和电缆隧道敷设时，还应采取（）的措施。",[495,497,499,501],{"key":20,"text":496,"correct":22},"防水、防潮；",{"key":24,"text":498,"correct":22},"防雷击;",{"key":27,"text":500,"correct":22},"防辐射；",{"key":31,"text":502,"correct":29},"防止煤粉积聚和火灾蔓延。",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":20,"analysis":33},1023856,"发电厂应设置电气用的总事故贮油池，其容量应按（）确定。",[507,509,511,513],{"key":20,"text":508,"correct":29},"最大一台变压器的油量；",{"key":24,"text":510,"correct":22},"最大一台变压器油量的2倍；",{"key":27,"text":512,"correct":22},"所有变压器油量的总量；",{"key":31,"text":514,"correct":22},"所有变压器油量的总量的1\u002F2。",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":24,"analysis":33},1023857,"同一路径中，全厂公用的（）回路的电缆应采取耐火分隔或分别敷设在两个互相 独立的电缆通道中。",[519,521,523,525],{"key":20,"text":520,"correct":22},"各个；",{"key":24,"text":522,"correct":29},"重要负荷；",{"key":27,"text":524,"correct":22},"所有；",{"key":31,"text":526,"correct":22},"各个等级。",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":24,"analysis":33},1023858,"简单循环及联合循环的发电机容量为（）及以上时’应设置交流保安电源。 A. 100MW； B. 200MW； C 300MW； D. 600MW；",[531,532,533,534],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":31,"analysis":33},1023859,"油浸式变压器及其他户内充油电气设备单台油量在（）以上时，应设置贮油渖及 .公共集油池。",[539,541,543,545],{"key":20,"text":540,"correct":22},"500kg；",{"key":24,"text":542,"correct":22},"750kg;",{"key":27,"text":544,"correct":22},"800kg；",{"key":31,"text":546,"correct":29},"1000kg。",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":20,"analysis":33},1023860,"贮油池容积应按贮存单台设备（）的油量确定.",[551,553,555,557],{"key":20,"text":552,"correct":29},"100%,",{"key":24,"text":554,"correct":22},"90%,",{"key":27,"text":556,"correct":22},"80%；",{"key":31,"text":558,"correct":22},"50%。",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":27,"analysis":33},1023861,"当公共集油池设有油水分离设施时，其容积可按最大一台充油箱的（）油量确定。 A. 80% ； B. 75%； C 60%； D.50%。",[563,564,565,566],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":24,"analysis":33},1023862,"消防用电设备应采用（）供电回路，当发生火灾时，仍应保证消防用电。",[571,573,575,577],{"key":20,"text":572,"correct":22},"双回路；",{"key":24,"text":574,"correct":29},"单独的；",{"key":27,"text":576,"correct":22},"公用的；",{"key":31,"text":578,"correct":22},"专用的。",[580,583,586,589,592,595],{"id":15,"name":581,"category":7,"favorite":582},"领导干部任职前廉政法规知识测试题",92,{"id":584,"name":585,"category":7,"favorite":15},595,"建筑结构与设备",{"id":587,"name":588,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":590,"name":591,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":593,"name":594,"category":7,"favorite":8},534,"BIM工程师",{"id":596,"name":594,"category":7,"favorite":8},535]