[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-40":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":574},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,40,50,2670,[13,30,38,48,60,72,84,92,103,114,122,130,138,146,155,167,179,191,203,215,227,239,247,259,271,283,295,307,315,327,339,351,363,374,386,398,410,420,432,444,456,468,479,491,503,515,527,539,550,562],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":23,"analysis":29},1023713,1,"单选题","发电机变压器组单元制接线中，如高压侧设有旁路母线，此时（）。 A.变压器回路可带旁路； B.变压器回路不宜带旁路； C可加旁路跨条D.根据系统要求确定。",[19,22,25,27],{"key":20,"text":20,"correct":21},"A",false,{"key":23,"text":23,"correct":24},"B",true,{"key":26,"text":26,"correct":21},"C",{"key":28,"text":28,"correct":21},"D","",{"id":31,"libraryId":5,"type":15,"typeLabel":16,"stem":32,"options":33,"answer":20,"analysis":29},1023714,"在变电所设计中，主变压器髙中压侧均设有旁路母线，此时主变压器回路（）。 A.均宜带旁路； B1不应带旁路； C.应带旁路； D.不宜带旁路",[34,35,36,37],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":21},{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":20,"analysis":29},1023715,"110?220kV配电装置选用全封闭SF6组合配电装置时，无论双母线还是单母线都 ( )",[42,44,46,47],{"key":20,"text":43,"correct":24},"不应设置旁路母线",{"key":23,"text":45,"correct":21},"设置旁路母线",{"key":26,"text":43,"correct":21},{"key":28,"text":45,"correct":21},{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":23,"analysis":29},1023716,"200MW机组以上的发电厂不宜采用三绕组变压器，如髙压和中压需要连接时可采用 变压器联络，当采用自耦变压器作联络变压器时，其主要潮流应为（）。",[52,54,56,58],{"key":20,"text":53,"correct":21},"高压向低、中压送电；",{"key":23,"text":55,"correct":24},"中、低压往高压送电；",{"key":26,"text":57,"correct":21},"C低压向高、中压送电",{"key":28,"text":59,"correct":21},"高、低压向中压送电.",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":23,"analysis":29},1023717,"200MW以上大型机组，发电机出口（）。",[64,66,68,70],{"key":20,"text":65,"correct":21},"可装设隔离开关；",{"key":23,"text":67,"correct":24},"不宜装设描离开关；",{"key":26,"text":69,"correct":21},"C应装设隔离开关；",{"key":28,"text":71,"correct":21},"不应装设隔离开关。",{"id":73,"libraryId":5,"type":15,"typeLabel":16,"stem":74,"options":75,"answer":23,"analysis":29},1023718,"220kV及以下的线路避雷器、主变压器出口避雷器、主变压器中性点避雷器 ( ).",[76,78,80,82],{"key":20,"text":77,"correct":21},"应装隔离开关；",{"key":23,"text":79,"correct":24},"不应装隔离开关；",{"key":26,"text":81,"correct":21},"宜装隔离开关；",{"key":28,"text":83,"correct":21},"可不装隔离开关。",{"id":85,"libraryId":5,"type":15,"typeLabel":16,"stem":86,"options":87,"answer":20,"analysis":29},1023719,"330、500kV 避雷器（ ）。 A.不应装设隔离开关 E应装设隔离开关； C.不宜装设隔离开关； D.可装设隔离开关。",[88,89,90,91],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":21},{"id":93,"libraryId":5,"type":15,"typeLabel":16,"stem":94,"options":95,"answer":20,"analysis":29},1023720,"直接接地系统中，当采用自耦变压器时，其中性点接地回路（）。",[96,98,99,101],{"key":20,"text":97,"correct":24},"不应装设隔离开关；",{"key":23,"text":65,"correct":21},{"key":26,"text":100,"correct":21},"不宜装设隔离开关",{"key":28,"text":102,"correct":21},"没有规定。",{"id":104,"libraryId":5,"type":15,"typeLabel":16,"stem":105,"options":106,"answer":20,"analysis":29},1023721,"直接接地系统中，当采用普通变压器时，中性点回路（)。",[107,109,110,112],{"key":20,"text":108,"correct":24},"应装设隔离开关；",{"key":23,"text":97,"correct":21},{"key":26,"text":111,"correct":21},"不宜装设隔离开关；",{"key":28,"text":113,"correct":21},"可装设隔离开关。",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":26,"analysis":29},1023722,"设有一台200MW机组，其额定容量为200MW，在额定容量运行时厂用电率为 6.8%,该机组最大连续出力为216MW,此出力时厂用电率为7. 2%。若电机的功率因数为 0.85’并设变压器温升不超过65℃’该机组主变压器容量宜选用（）。 A. 220kVA B. 230kVA C 240kVA； D. 250kVA。",[118,119,120,121],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":21},{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":23,"analysis":29},1023723,"阻波器和耦合电容器的配置是根据（)。 A.继电保护要求；通信要求； C捕捉同期要求； D.自动装里要求。",[126,127,128,129],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":21},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":23,"analysis":29},1023724,"330、500kV线路并联电抗器初期一般不装设断路器或隔离开关，因为其主要作用 是（），故不允许退出运行。 A.限制冲击过电压和接地电流B.限制工频过电压和潜供电流； C限制进行波过电压和接地电流； D.限制雷击过电压和接地电流。",[134,135,136,137],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":21},{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":23,"analysis":29},1023725,"当采用 接线，其初期回路只有两回进线和两回出线，此时的接线和（）相类似 A.内桥接线； B.四角形接线； C外桥接线； D.单母线接线。",[142,143,144,145],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":24},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":21},{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":23,"analysis":29},1023726,"接于发电机与变压器引出线上的避雷器（）。",[150,152,153,154],{"key":20,"text":151,"correct":21},"宜装设隔离开关；",{"key":23,"text":111,"correct":24},{"key":26,"text":69,"correct":21},{"key":28,"text":71,"correct":21},{"id":156,"libraryId":5,"type":15,"typeLabel":16,"stem":157,"options":158,"answer":23,"analysis":29},1023727,"最小发电机容量为100MW机组的电厂其出线电压（ ）。",[159,161,163,165],{"key":20,"text":160,"correct":21},"可超过两种；",{"key":23,"text":162,"correct":24},"不应超过两种；",{"key":26,"text":164,"correct":21},"根据需要确定；",{"key":28,"text":166,"correct":21},"—般不超过两种。",{"id":168,"libraryId":5,"type":15,"typeLabel":16,"stem":169,"options":170,"answer":26,"analysis":29},1023728,"容量为200MW机组的升压变压器当有两种高电压时（ )。",[171,173,175,177],{"key":20,"text":172,"correct":21},"应采用三绕组变压器；",{"key":23,"text":174,"correct":21},"不应采用三绕组变压器；",{"key":26,"text":176,"correct":24},"不宜采用三绕組变压器；",{"key":28,"text":178,"correct":21},"宜采用三绕組变压器。",{"id":180,"libraryId":5,"type":15,"typeLabel":16,"stem":181,"options":182,"answer":20,"analysis":29},1023729,"双母线接线的主要目的是解决（）。",[183,185,187,189],{"key":20,"text":184,"correct":24},"母线检修问题；",{"key":23,"text":186,"correct":21},"母线分段断路器检修问題；",{"key":26,"text":188,"correct":21},"母线联络断路器检修问题；",{"key":28,"text":190,"correct":21},"母线隔离开关检修问题。",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":20,"analysis":29},1023730,"当采用少油断路器时，220kV出线和110kV出线在（）时可采用带专用旁路的 旁路母线。",[195,197,199,201],{"key":20,"text":196,"correct":24},"220kV 四回，110kV 六回；",{"key":23,"text":198,"correct":21},"220kV 五回，110kV 七回；",{"key":26,"text":200,"correct":21},"220kV二回，110kV五回；",{"key":28,"text":202,"correct":21},"220kV三回，110kV六回。",{"id":204,"libraryId":5,"type":15,"typeLabel":16,"stem":205,"options":206,"answer":26,"analysis":29},1023731,"小型火力发电厂、发电机中性点采用不接地方式，当与发电机电气上直接连接的 6kV回路中单相接地故障电流超过（）时宜考虑装设消弧线圈。",[207,209,211,213],{"key":20,"text":208,"correct":21},"5A；",{"key":23,"text":210,"correct":21},"3A；",{"key":26,"text":212,"correct":24},"4A；",{"key":28,"text":214,"correct":21},"8A。",{"id":216,"libraryId":5,"type":15,"typeLabel":16,"stem":217,"options":218,"answer":23,"analysis":29},1023732,"采用旁路母线的目的是为了便于（）。",[219,221,223,225],{"key":20,"text":220,"correct":21},"母线分段断路器的检修;",{"key":23,"text":222,"correct":24},"进出线回路断路器的检修；",{"key":26,"text":224,"correct":21},"母线检修；",{"key":28,"text":226,"correct":21},"母线隔离开关的检修",{"id":228,"libraryId":5,"type":15,"typeLabel":16,"stem":229,"options":230,"answer":26,"analysis":29},1023733,"接线主要使用的电压等级为（）。",[231,233,235,237],{"key":20,"text":232,"correct":21},"220?500kV;",{"key":23,"text":234,"correct":21},"220?300kV;",{"key":26,"text":236,"correct":24},"300?500kV 及以上",{"key":28,"text":238,"correct":21},"110~300kV。",{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":20,"analysis":29},1023734,"采用扩大单元接线，首先宜考虑图4-1中的（）方式，如不合适再考虑另一种方式。",[243,244,245,246],{"key":20,"text":20,"correct":24},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":21},{"key":28,"text":28,"correct":21},{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":20,"analysis":29},1023735,"容量200MW机组中性点可采用（ ）。",[251,253,255,257],{"key":20,"text":252,"correct":24},"不接地，经消弧线圈或高电阻接地方式；",{"key":23,"text":254,"correct":21},"不接地，经消弧线圈或低电阻接地方式；",{"key":26,"text":256,"correct":21},"经消弧线圈或高阻抗接地方式；",{"key":28,"text":258,"correct":21},"经高阻抗接地方式。",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":26,"analysis":29},1023736,"3?60kV系统，中性点不直接接地，在发生单相接地故障后，仍能允许带负荷 ( )。",[263,265,267,269],{"key":20,"text":264,"correct":21},"0.5h；",{"key":23,"text":266,"correct":21},"1h;",{"key":26,"text":268,"correct":24},"2h；",{"key":28,"text":270,"correct":21},"1.5h",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":26,"analysis":29},1023737,"小电流接地系统，即中性点不直接接地系统在我国常用的电压系统（个别地区除外）为（）。",[275,277,279,281],{"key":20,"text":276,"correct":21},"220kV 系统；",{"key":23,"text":278,"correct":21},"35?110kV 系统；",{"key":26,"text":280,"correct":24},"3~35kV 系统；",{"key":28,"text":282,"correct":21},"3?10kV 系统。",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":23,"analysis":29},1023738,"如采用单母线分段接线，在变电所设计中与各级电压出线回路数有关，下列条件合 适的是（）。",[287,289,291,293],{"key":20,"text":288,"correct":21},"6?10kV4回以上，35?63kV4回以上，110?220kV2回以上；",{"key":23,"text":290,"correct":24},"6?10kV6回以上，35?63kV4?8回，110?220kV3?4回；",{"key":26,"text":292,"correct":21},"6?10kV8回以下，35?63kV6回以上，110?220kV2?4回；",{"key":28,"text":294,"correct":21},"6?10kV10回，35?63kV4回，110?220kV2回。",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":23,"analysis":29},1023739,"对电力系统的稳定性干扰最严重的故障一般是（）。",[299,301,303,305],{"key":20,"text":300,"correct":21},"投切大型空载变压器；",{"key":23,"text":302,"correct":24},"发生三相短路故障；",{"key":26,"text":304,"correct":21},"C发生两相接地短路；",{"key":28,"text":306,"correct":21},"发生单相接地。",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":26,"analysis":29},1023740,"在考虑系统新增机组时，一般最大机组容量不超过系统总容量的（）。 A. 4%?6% R 6%?8%; C. 8%?10%; D.5%?7%。",[311,312,313,314],{"key":20,"text":20,"correct":21},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":24},{"key":28,"text":28,"correct":21},{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":28,"analysis":29},1023741,"当220kV配电装置进出线数为（）时，宜采用双母线双分段接线。",[319,321,323,325],{"key":20,"text":320,"correct":21},"6?8回；",{"key":23,"text":322,"correct":21},"8?10回；",{"key":26,"text":324,"correct":21},"10~14回；",{"key":28,"text":326,"correct":24},"15回以上",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":20,"analysis":29},1023742,"110kV及以上配电装置采用角形接线的条件是（）。",[331,333,335,337],{"key":20,"text":332,"correct":24},"一次建成，最终进出线为3?5回;",{"key":23,"text":334,"correct":21},"一次建成，最终进出线为5回以上；",{"key":26,"text":336,"correct":21},"需再扩建，一期进出线为3?5回；",{"key":28,"text":338,"correct":21},"需再扩建，一期进出线为5回以上。",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":28,"analysis":29},1023743,"双母线接线采用双母线同时运行时具有单母线分段接线特点，以下说法正确的是 ( )。",[343,345,347,349],{"key":20,"text":344,"correct":21},"双母线接线与单母线分段接线是等效的；",{"key":23,"text":346,"correct":21},"单母线分段接线具有更大的运行灵活性；",{"key":26,"text":348,"correct":21},"两者的设备数量一样；",{"key":28,"text":350,"correct":24},"双母线接线具有更大的运行灵活性。",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":26,"analysis":29},1023744,"如果要求任一组母线发生短路故障均不会影响各支路供电，则应选用（）。",[355,357,359,361],{"key":20,"text":356,"correct":21},"双母线接线；",{"key":23,"text":358,"correct":21},"双母线分段带旁路接线；",{"key":26,"text":360,"correct":24},"一台半断路器接线；",{"key":28,"text":362,"correct":21},"多角形接线。",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":28,"analysis":29},1023745,"4台容量为600MW的机组接入500kV系统，分两期建设。一期先建2X 600MW 的机组并有2回出线，二期工程将再扩建2X600MW的机组，主接线宜采用（）。",[367,368,370,372],{"key":20,"text":356,"correct":21},{"key":23,"text":369,"correct":21},"桥形接线；",{"key":26,"text":371,"correct":21},"四角形接线；",{"key":28,"text":373,"correct":24},"一台半断路器接线",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":20,"analysis":29},1023746,"内桥接线具有的特点为（）。",[378,380,382,384],{"key":20,"text":379,"correct":24},"变压器不经常切换，线路长，故障率高，线路无穿越功率；",{"key":23,"text":381,"correct":21},"变压器不经常切换，线路长，故障率高，线路有穿越功率；",{"key":26,"text":383,"correct":21},"变压器经常切换，线路短，故障率低，线路无穿越功率；",{"key":28,"text":385,"correct":21},"变压器经常切换，线路短，故障率低，线路有穿越功率。",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":26,"analysis":29},1023747,"为便于运行调度灵活选择接地点，普通变压器中性点应（）。",[390,392,394,396],{"key":20,"text":391,"correct":21},"设置隔离开关，变压器中性点采用半绝缘；",{"key":23,"text":393,"correct":21},"设置隔离开关和避雷器，变压器中性点采用全绝缘；",{"key":26,"text":395,"correct":24},"设置隔离开关和避雷器,变压器采用半绝缘；",{"key":28,"text":397,"correct":21},"直接接地。",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":26,"analysis":29},1023748,"在一台半断路器接线中，当有3个及以上的完整串时，其配串原则宜为（）。",[402,404,406,408],{"key":20,"text":403,"correct":21},"同名回路配置在不同串内，并应接入不同侧母线，进出线应装设隔离开关；",{"key":23,"text":405,"correct":21},"同名回路配置在不同串内，并应接入不同侧母线，进出线不宜装设隔离开关；",{"key":26,"text":407,"correct":24},"同名回路配置在不同串内，可接入同侧母线，进出线不宜装设隔离开关；",{"key":28,"text":409,"correct":21},"同名回路配置在不同串内，可接入同侧母线，进出线应装设隔离开关。",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":26,"analysis":29},1023749,"330?500kV配电装置的接线，当进出线回路数为6回及以上且配电装置在系统中 具有重要地位时，宜采用（）。",[414,415,417,418],{"key":20,"text":356,"correct":21},{"key":23,"text":416,"correct":21},"双母线单分段带旁路接线；",{"key":26,"text":360,"correct":24},{"key":28,"text":419,"correct":21},"双母线单分段接线。",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":28,"analysis":29},1023750,"发电厂单台装机容量为200MW时，采用（），可不设发电机出口断路器。",[424,426,428,430],{"key":20,"text":425,"correct":21},"扩大单元接线；",{"key":23,"text":427,"correct":21},"发电机一三绕组变压器单元接线；",{"key":26,"text":429,"correct":21},"发电机一自耦变压器单元接线；",{"key":28,"text":431,"correct":24},"发电机一双绕組变压器单元接线。",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":20,"analysis":29},1023751,"容量为100MW的机组，采用发电机一双绕组变压器单元接线时，宜（）。",[436,438,440,442],{"key":20,"text":437,"correct":24},"设里发电机出口断路器和隔离开关，厂用分支应接在主变压器与断路器之间；",{"key":23,"text":439,"correct":21},"设置发电机出口断路器和隔离开关，厂用分支应接在发电机与断路器之间",{"key":26,"text":441,"correct":21},"不设里发电机出口断路器和隔离开关，厂用分支直接从发电机出口T接;",{"key":28,"text":443,"correct":21},"设置发电机出口隔离开关，厂用分支应接在发电机与隔离开关之间。",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":28,"analysis":29},1023752,"容量为200?300MW的发电机与双绕组为单元连接时，在发电机与变压器之间应 装设（）。",[448,450,452,454],{"key":20,"text":449,"correct":21},"断路器；",{"key":23,"text":451,"correct":21},"负荷开关；",{"key":26,"text":453,"correct":21},"隔离开关；",{"key":28,"text":455,"correct":24},"可拆连接点",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":26,"analysis":29},1023753,"在双母线接线中，为在进出线断路器检修时保证连续供电，采取设置旁路母线措施。 采用设置母联兼旁路断路器方案时，下列说法不正确的是()",[460,462,464,466],{"key":20,"text":461,"correct":21},"对双母线的固定连接的运行方式有影响；",{"key":23,"text":463,"correct":21},"可节约一台断路器；",{"key":26,"text":465,"correct":24},"C不増加隔离开关的倒闸操作；",{"key":28,"text":467,"correct":21},"节约一个断路器间隔。",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":20,"analysis":29},1023754,"在双母线接线中，为在进出线断路器检修时保证连续供电，采取设置旁路母线措施。 采用设置专用旁路断路器方案时，下列说法不正确的是（）.",[472,473,475,477],{"key":20,"text":461,"correct":24},{"key":23,"text":474,"correct":21},"需增加一台断路器;",{"key":26,"text":476,"correct":21},"不增加隔离开关的倒闸操作；",{"key":28,"text":478,"correct":21},"需増加一个断路器间隔。",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":26,"analysis":29},1023755,"在双母线接线中，为在进出线断路器检修时保证连续供电，采取设置旁路母线措施。 旁路母线投入运行时，（）设置避雷器。",[483,485,487,489],{"key":20,"text":484,"correct":21},"需要；",{"key":23,"text":486,"correct":21},"不需要；",{"key":26,"text":488,"correct":24},"根据避雷器到被保护设备的距离是否满足要求确定；",{"key":28,"text":490,"correct":21},"根据投资情况确定。",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":26,"analysis":29},1023756,"自耦变压器虽然有损耗小、造价低、效率高等优点，但在使用中仍应考虑下列问题。 电压比的选取（）。",[495,497,499,501],{"key":20,"text":496,"correct":21},"可任意组合比；",{"key":23,"text":498,"correct":21},"取相近的电压等级；",{"key":26,"text":500,"correct":24},"在3:1的范围内；",{"key":28,"text":502,"correct":21},"在4:1范围内。",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":26,"analysis":29},1023757,"自耦变压器虽然有损耗小、造价低、效率高等优点，但在使用中仍应考虑下列问题。 升压型结构的自耦变压器在高中压侧交换功率时，可能使额定容量受到限制，所以 应该（ ）。",[507,509,511,513],{"key":20,"text":508,"correct":21},"限制运行方式；",{"key":23,"text":510,"correct":21},"退出运行；",{"key":26,"text":512,"correct":24},"装设特殊过负荷保护",{"key":28,"text":514,"correct":21},"系统调度处理。",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":26,"analysis":29},1023758,"自耦变压器虽然有损耗小、造价低、效率高等优点，但在使用中仍应考虑下列问题。 自耦变压器采用中性点调压，当高压侧电压调整时，低压侧电压也随之两变，特别是在低压侧接有厂用电和无功设备时，在设计中应（）。",[519,521,523,525],{"key":20,"text":520,"correct":21},"改变选择方式；",{"key":23,"text":522,"correct":21},"重新考虑设计方案；",{"key":26,"text":524,"correct":24},"仔细核算电压和无功，改变设备参数；",{"key":28,"text":526,"correct":21},"限制运行方式。",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":26,"analysis":29},1023759,"35?110kV无人值班变电站的主接线。 可不考虑的因素是（）。",[531,533,535,537],{"key":20,"text":532,"correct":21},"电力系统中的地位；",{"key":23,"text":534,"correct":21},"出线回路数；",{"key":26,"text":536,"correct":24},"设备运输；",{"key":28,"text":538,"correct":21},"负荷性质。",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":26,"analysis":29},1023760,"35?110kV无人值班变电站的主接线。 其中若110kV出线为二回，并从经济性考虑，可采用（）。",[543,545,547,548],{"key":20,"text":544,"correct":21},"单母线或变压器线路组；",{"key":23,"text":546,"correct":21},"单母线分段；",{"key":26,"text":369,"correct":24},{"key":28,"text":549,"correct":21},"双母线接线。",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":20,"analysis":29},1023761,"35?110kV无人值班变电站的主接线。 若上述条件二回出线中有系统交换潮流，则宜采用（）。",[554,556,558,560],{"key":20,"text":555,"correct":24},"外桥接线；",{"key":23,"text":557,"correct":21},"扩大桥接线；",{"key":26,"text":559,"correct":21},"内桥接线；",{"key":28,"text":561,"correct":21},"单母线。",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":28,"analysis":29},1023762,"某35~110kV变电所若35kV出线8回，110kV出线为4回。 此时宜采用的接线方式为（）。",[566,568,570,572],{"key":20,"text":567,"correct":21},"35kV双母线，110kV双母线；",{"key":23,"text":569,"correct":21},"35kV单母线分段，110kV单母线分段；",{"key":26,"text":571,"correct":21},"35kV双母线，110kV单母线；",{"key":28,"text":573,"correct":24},"35kV双母线，110kV单母线分段。",[575,578,581,584,587,590],{"id":15,"name":576,"category":7,"favorite":577},"领导干部任职前廉政法规知识测试题",92,{"id":579,"name":580,"category":7,"favorite":15},595,"建筑结构与设备",{"id":582,"name":583,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":585,"name":586,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":588,"name":589,"category":7,"favorite":8},534,"BIM工程师",{"id":591,"name":589,"category":7,"favorite":8},535]