[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-4":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":606},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,4,50,2670,[13,34,46,58,70,82,94,106,118,128,140,152,163,175,187,199,211,223,235,247,259,271,283,295,307,319,331,343,355,367,379,391,403,415,426,437,449,461,473,485,497,509,519,531,543,553,565,573,584,596],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},1021900,1,"单选题","选用电器额定电流不得低于所在回路各种可能运行方式下的持续工作电流，即IN≥Ig,不同回路的持续工作电流： 电动机回路计算工作电流应选用下面所给的条件中的（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","电动机的額定电流；",true,{"key":24,"text":25,"correct":26},"B","1.05倍电动机额定电流；",false,{"key":28,"text":29,"correct":26},"C","1.1倍电动机额定电流；",{"key":31,"text":32,"correct":26},"D","1.2倍电动机額定电流。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},1021901,"某大型发电厂建有4台300MW机组，以发变组单元接线接入厂内330kV配电装置。330kV出线共4回。该电厂发电机中性点接地方式应为（），要求发电机内部发生单相接地时应瞬时跳闸。",[38,40,42,44],{"key":20,"text":39,"correct":26},"不接地；",{"key":24,"text":41,"correct":26},"经消孤线圓接地；",{"key":28,"text":43,"correct":22},"经高电阻接地；",{"key":31,"text":45,"correct":26},"经低电阻接地。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},1021902,"隔离开关选择， 隔离开关按技术条件选择，下面所列错误的是（）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"电压、电流、频芈、机械荷载；",{"key":24,"text":53,"correct":26},"动稳定电流，热稳定电流和持续时间；",{"key":28,"text":55,"correct":22},"开断和关合性能；",{"key":31,"text":57,"correct":26},"对地和断口间的绝缘水平泄漏比距。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},1021903,"隔离开关选择，",[62,64,66,68],{"key":20,"text":63,"correct":26},"装在屋外的隔离开关环境校验中，无须检验（）。",{"key":24,"text":65,"correct":26},"环境温度； B最大风速、覆冰厚度；",{"key":28,"text":67,"correct":22},"相对湿度；",{"key":31,"text":69,"correct":26},"污秽。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},1021904,"隔离开关选择， 关于屋外隔离开关接线端允许水平机械荷载，下面所列正确的是（），",[74,76,78,80],{"key":20,"text":75,"correct":26},"35~63kV单柱式隔离开关为800N；",{"key":24,"text":77,"correct":26},"11OkV单柱式隔离开关为1100N；",{"key":28,"text":79,"correct":22},"11OkV单柱式隔离开关为1000N；",{"key":31,"text":81,"correct":26},"220kV单柱式隔离开关为1600N。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},1021905,"髙压熔选择. 高压熔断器按技术条件选择中，不作要求的是（）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"电压、电流；",{"key":24,"text":89,"correct":22},"机械荷载；",{"key":28,"text":91,"correct":26},"开断能力；",{"key":31,"text":93,"correct":26},"被保护电器特性。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},1021906,"髙压熔选择. 屋内髙压熔断器，不需检验的项目是（）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"环境温度；",{"key":24,"text":101,"correct":26},"地震裂度；",{"key":28,"text":103,"correct":22},"污移；",{"key":31,"text":105,"correct":26},"海技高度。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},1021907,"髙压熔选择. 关于髙压熔断器的使用条件，错误的是（）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"限流式高压熔断器可以使用在电网工作电压低于熔断器额定电压的电网中；",{"key":24,"text":113,"correct":26},"限流式高压熔断器不宜使用在电闲工作电庄低于熔断器額定电压的电网中；",{"key":28,"text":115,"correct":26},"高压熔断器熔管的頼定电流应大于熔体的额定电流；",{"key":31,"text":117,"correct":26},"高压熔断器熔管的額定电流可以等于熔体的額定电流。",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":28,"analysis":33},1021908,"避雷器选择. 屋内避雷器，不需检验的项目是（）。",[122,123,124,126],{"key":20,"text":99,"correct":26},{"key":24,"text":101,"correct":26},{"key":28,"text":125,"correct":22},"污秽；",{"key":31,"text":127,"correct":26},"海拔高度。",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":31,"analysis":33},1021909,"避雷器选择. 关于避雷器的配置，以下所述错误的是（）。",[132,134,136,138],{"key":20,"text":133,"correct":26},"配电装置的每组母线上应装设避雷器，但进出线都装设避雷器时除外；",{"key":24,"text":135,"correct":26},"配电装置的每组母线上应装设避雷器，变压器进线是否装避雷器另行校核；",{"key":28,"text":137,"correct":26},"330kV及以上变压器处必须装设避雷器，并尽可能靠近设备本体；",{"key":31,"text":139,"correct":22},"220kV及以下变压器处，应在变压器附近装设一组避雷器。",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":28,"analysis":33},1021910,"电流互感器选择. 电流互感器不按下列（）技术条件选择和棱验。",[144,146,148,150],{"key":20,"text":145,"correct":26},"一次回路电压和电流；",{"key":24,"text":147,"correct":26},"二次电流和二次负荷；",{"key":28,"text":149,"correct":22},"开断电流；",{"key":31,"text":151,"correct":26},"准确度等级和暂态特性。",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":28,"analysis":33},1021911,"电流互感器选择. 户外电流互感器，不需检验的是（）。",[156,158,160,161],{"key":20,"text":157,"correct":26},"环境溫度；",{"key":24,"text":159,"correct":26},"最大风速；",{"key":28,"text":67,"correct":22},{"key":31,"text":162,"correct":26},"污秽.",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":20,"analysis":33},1021912,"电流互感器选择. 关于电流互感器二次侧额定电流的数值，以下正确的是（）。",[167,169,171,173],{"key":20,"text":168,"correct":22},"1A；",{"key":24,"text":170,"correct":26},"2A；",{"key":28,"text":172,"correct":26},"3A；",{"key":31,"text":174,"correct":26},"4A。",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":24,"analysis":33},1021913,"电流互感器选择. 关于电流互感器型式选择，下面所述错误的是（）。 A. 6~20kV屋内配电装直用LD单匝贯穿式，和LF复匝貫穿式； B. 6~20kV高压开关拒中用LMC或LAJ型； C.发电机回路用LM",[179,181,183,185],{"key":20,"text":180,"correct":26},"LMZ型LAJ、LBJ型；",{"key":24,"text":182,"correct":22},"2000A以上回路用LM",{"key":28,"text":184,"correct":26},"LMZ型LAJ、LBJ型、LR",{"key":31,"text":186,"correct":26},"LRZD型。",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":24,"analysis":33},1021914,"某500kV配电装置，共有出线6回，为节省线路走廊，均采用同塔双回，经计算，线路重合闸时，过电压水平超过规程要求，为此考虑在断路器的断口间装设并联电阻，其电阻值为（）。",[191,193,195,197],{"key":20,"text":192,"correct":26},"200；",{"key":24,"text":194,"correct":22},"200~1000；",{"key":28,"text":196,"correct":26},"1~1Ok;",{"key":31,"text":198,"correct":26},"10k。",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":28,"analysis":33},1021915,"某发电厂升压站220kV配电装置的主接线为四角形接线，2台200MW发电机组,2回出线。 经计算，某一档线的拉力为23000N，该档线的耐张绝缘子应选择（）。",[203,205,207,209],{"key":20,"text":204,"correct":26},"X—4.5；",{"key":24,"text":206,"correct":26},"XP-7；",{"key":28,"text":208,"correct":22},"XP-10；",{"key":31,"text":210,"correct":26},"XP—16。",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":28,"analysis":33},1021916,"某发电厂升压站220kV配电装置的主接线为四角形接线，2台200MW发电机组,2回出线。 如果短路水平按40k A，TA准确级取5P20\u002F5P20\u002F5P20\u002F0.5\u002F0.2，则四角形内TA变比宜为（）。",[215,217,219,221],{"key":20,"text":216,"correct":26},"2000-4000\u002F5A；",{"key":24,"text":218,"correct":26},"1500-3000\u002F5A；",{"key":28,"text":220,"correct":22},"1000-2000\u002F5A；",{"key":31,"text":222,"correct":26},"800-1600\u002F5A。",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":20,"analysis":33},1021917,"某发电厂升压站220kV配电装置的主接线为四角形接线，2台200MW发电机组,2回出线。 下列位置不需装设过电压保护的是（）。",[227,229,231,233],{"key":20,"text":228,"correct":22},"发电机中性点；",{"key":24,"text":230,"correct":26},"发电机出口；",{"key":28,"text":232,"correct":26},"主变中性点；",{"key":31,"text":234,"correct":26},"主变高压侧。",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":31,"analysis":33},1021918,"某热电厂装机2X50MW, cosΨ=0.8,接10.5kV发电机电压母线，10.5kV为双母线单分段接线，为限制短路电流，分段回路装设有限流电抗器。 分段断路器的额定电流不合理的是（）。",[239,241,243,245],{"key":20,"text":240,"correct":26},"2000A；",{"key":24,"text":242,"correct":26},"2500A；",{"key":28,"text":244,"correct":26},"3150A；",{"key":31,"text":246,"correct":22},"4000A。",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":24,"analysis":33},1021919,"某热电厂装机2X50MW, cosΨ=0.8,接10.5kV发电机电压母线，10.5kV为双母线单分段接线，为限制短路电流，分段回路装设有限流电抗器。 对该分段电抗器的选择，以下说法错误的是（）。",[251,253,255,257],{"key":20,"text":252,"correct":26},"应将短录电流限制到要求值；",{"key":24,"text":254,"correct":22},"应校验母线剩余电压；",{"key":28,"text":256,"correct":26},"正常工作时，电抗器的电压损失不得大于母线额定电压的5%；",{"key":31,"text":258,"correct":26},"应校验动稳定。",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":28,"analysis":33},1021920,"某热电厂装机2X50MW, cosΨ=0.8,接10.5kV发电机电压母线，10.5kV为双母线单分段接线，为限制短路电流，分段回路装设有限流电抗器。 发电机电压负荷最大为70MW，最小为45MW,cosψ=0.8,为将剩余容量送入系统，需装设主变压器，下列装设方式最合理的是（）。",[263,265,267,269],{"key":20,"text":264,"correct":26},"1台70MVA的变压器；",{"key":24,"text":266,"correct":26},"2台70MVA的变压器；",{"key":28,"text":268,"correct":22},"2台50MVA的变压器；",{"key":31,"text":270,"correct":26},"2台40MVA的变压器。",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":28,"analysis":33},1021921,"某220kV变电所距海边约0.8km。 所内66kV配电装置宜选用（）。",[275,277,279,281],{"key":20,"text":276,"correct":26},"户外GIS；",{"key":24,"text":278,"correct":26},"户内GIS；",{"key":28,"text":280,"correct":22},"屋内配电装置；",{"key":31,"text":282,"correct":26},"屋外配电装置，但应选用罐路器和大爬距电瓷产品。",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":31,"analysis":33},1021922,"某220kV变电所距海边约0.8km。 66kV经消弧线圏接地，主变压器66kV侧的爬距宜取（）。",[287,289,291,293],{"key":20,"text":288,"correct":26},"1813mm；",{"key":24,"text":290,"correct":26},"2248mm；",{"key":28,"text":292,"correct":26},"3150mm；",{"key":31,"text":294,"correct":22},"3906mm,",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":24,"analysis":33},1021923,"某500kV变电所，所址海拔2100m， 500kV出线本期2回，最终6回；主变压器本期1组750MV A，最终2组，220kV出线本期8回，最终120。",[299,301,303,305],{"key":20,"text":300,"correct":26},"如果该变电所为降压变电所，则最终220kV出线的输送总容量不超过（）.",{"key":24,"text":302,"correct":22},"1071MVA；",{"key":28,"text":304,"correct":26},"1500MVA； C750MVA；",{"key":31,"text":306,"correct":26},"1050MVA。",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":28,"analysis":33},1021924,"某500kV变电所，所址海拔2100m， 500kV出线本期2回，最终6回；主变压器本期1组750MV A，最终2组，220kV出线本期8回，最终120。 如果主变压器容量为1000MV A，中压侧抽头为230±2X2.5%kV,则220kV主变压器回路的工作电流为（）。",[311,313,315,317],{"key":20,"text":312,"correct":26},"2756A；",{"key":24,"text":314,"correct":26},"2624A；",{"key":28,"text":316,"correct":22},"2636A；",{"key":31,"text":318,"correct":26},"2510A。",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":24,"analysis":33},1021925,"—台电压比为525\u002F230±8X1.25%\u002F35kV的自耦变压器，当高压側电压升髙到550kV时，要求中压侧仍维持230kV. 分接头位置应选择（）。",[323,325,327,329],{"key":20,"text":324,"correct":26},"5；",{"key":24,"text":326,"correct":22},"6；",{"key":28,"text":328,"correct":26},"7；",{"key":31,"text":330,"correct":26},"8。",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":28,"analysis":33},1021926,"—台电压比为525\u002F230±8X1.25%\u002F35kV的自耦变压器，当高压側电压升髙到550kV时，要求中压侧仍维持230kV. 调压后，低压侧电压为（）。",[335,337,339,341],{"key":20,"text":336,"correct":26},"35kV；",{"key":24,"text":338,"correct":26},"37.5kV；",{"key":28,"text":340,"correct":22},"37.9kV；",{"key":31,"text":342,"correct":26},"38.2kV。",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":24,"analysis":33},1021927,"某发电厂装机为2X350MW+2X200MW，以发电机一变压器组单元接线接入220kV配电装置，送出线路共5回，每回线路的最大输送功率均为300MW,功率因素cosψ=0.85。主变压器为420MVA或250MV A，髙压侧抽头为（230—2X2.5%）kV。220kV配电装置选用双母线单分段出线带旁路母线接线。 母联回路、旁路回路的持续工作电流分别为（）。",[347,349,351,353],{"key":20,"text":348,"correct":26},"1102A,926A；",{"key":24,"text":350,"correct":22},"1107A,926A;",{"key":28,"text":352,"correct":26},"1102A,1107A；",{"key":31,"text":354,"correct":26},"1107A,1107A。",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":31,"analysis":33},1021928,"某发电厂装机为2X350MW+2X200MW，以发电机一变压器组单元接线接入220kV配电装置，送出线路共5回，每回线路的最大输送功率均为300MW,功率因素cosψ=0.85。主变压器为420MVA或250MV A，髙压侧抽头为（230—2X2.5%）kV。220kV配电装置选用双母线单分段出线带旁路母线接线。 该电厂2台350MW机组和2台200MW机组的发电机额定电压可以分别是（）。",[359,361,363,365],{"key":20,"text":360,"correct":26},"20kV,18kV；",{"key":24,"text":362,"correct":26},"22kV,20kV；",{"key":28,"text":364,"correct":26},"22kV,18kV；",{"key":31,"text":366,"correct":22},"18kV,15.75kV.",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":28,"analysis":33},1021929,"某热电厂扩建2台机组，发电机单机额定容量Se=50MW,额定功率因数为0.85,额定电压Ue=10.5kV，2台发电机以扩大单元接线接入已建的11OkV升压站。经计算，发电机电压回路及主变压器低压绕组的电容电流总计为4.5A。 主变压器宜选择（）。",[371,373,375,377],{"key":20,"text":372,"correct":26},"2台60MVA的变压器；",{"key":24,"text":374,"correct":26},"1台120MVA的双绕组变压器；",{"key":28,"text":376,"correct":22},"1台120\u002F60—60MVA的低压分裂绕组变压器；",{"key":31,"text":378,"correct":26},"1台120MVA的三绕组变压器。",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":31,"analysis":33},1021930,"某热电厂扩建2台机组，发电机单机额定容量Se=50MW,额定功率因数为0.85,额定电压Ue=10.5kV，2台发电机以扩大单元接线接入已建的11OkV升压站。经计算，发电机电压回路及主变压器低压绕组的电容电流总计为4.5A。 2台机组的中性点接地方式一般是（）。",[383,385,387,389],{"key":20,"text":384,"correct":26},"中性点不接地；",{"key":24,"text":386,"correct":26},"中性点直接接地；",{"key":28,"text":388,"correct":26},"中性点经消弧线圈接地（过补偿）；",{"key":31,"text":390,"correct":22},"中性点经消弧线国接地（欠补偿）。",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":31,"analysis":33},1021931,"某热电厂扩建2台机组，发电机单机额定容量Se=50MW,额定功率因数为0.85,额定电压Ue=10.5kV，2台发电机以扩大单元接线接入已建的11OkV升压站。经计算，发电机电压回路及主变压器低压绕组的电容电流总计为4.5A。 在正常情况下，发电机长时间中性点位移电压不应超过（ ）。",[395,397,399,401],{"key":20,"text":396,"correct":26},"1.05kV；",{"key":24,"text":398,"correct":26},"0.61kV；",{"key":28,"text":400,"correct":26},"1.83kV；",{"key":31,"text":402,"correct":22},"6.06kV。",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":24,"analysis":33},1021932,"某工程6kV配电装置其出线带电抗器。 6kV出线回路工作电流为523 A，为限制短路电流装设出线电抗器，电抗器夏天排风温度为55℃,应选用电抗器的型号规范为（）。",[407,409,411,413],{"key":20,"text":408,"correct":26},"XKK-6-600-5；",{"key":24,"text":410,"correct":22},"XKK-6-800-5；",{"key":28,"text":412,"correct":26},"XKK-6-1000-5；",{"key":31,"text":414,"correct":26},"XKK—6—1500—5。",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":28,"analysis":33},1021933,"某工程6kV配电装置其出线带电抗器。 6kV出线回路电压损失为3.15%,为满足线路末端电压损失不大于5%，应选用电抗器的型号规范为（）。",[419,420,422,424],{"key":20,"text":408,"correct":26},{"key":24,"text":421,"correct":26},"XKK—6—80.0-5；",{"key":28,"text":423,"correct":22},"XKK—6-1000-5；",{"key":31,"text":425,"correct":26},"XKK-6-1500-5。",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":31,"analysis":33},1021934,"某工程6kV配电装置其出线带电抗器。 6kV出线系厂用电源，最大一台厂用辅机（给水泵）电动机型号为YK2000—2\u002F1180,额定功率Pe=2000kW，启动电流倍数kg=6，功率因素cosψ=0.86，效率η=O.95，给水果电动机启动前已带负荷S1=4576kV A，应选用的电抗器为（）。",[430,431,433,435],{"key":20,"text":410,"correct":26},{"key":24,"text":432,"correct":26},"XKK—6—1000-5；",{"key":28,"text":434,"correct":26},"XKK-6-1500-5；",{"key":31,"text":436,"correct":22},"XKK-6-2000-5。",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":24,"analysis":33},1021935,"某35kV线路全长为35km? 当全线为架空地线的架空线路时，下面电容电流正确的是（）。",[441,443,445,447],{"key":20,"text":442,"correct":26},"3.042A；",{"key":24,"text":444,"correct":22},"4.04A；",{"key":28,"text":446,"correct":26},"4.5A；",{"key":31,"text":448,"correct":26},"4.73A,",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":28,"analysis":33},1021936,"某35kV线路全长为35km? 当全线为无架空地线的架空线路时，下面电容电流正确的是（）。",[453,455,457,459],{"key":20,"text":454,"correct":26},"2.52A；",{"key":24,"text":456,"correct":26},"3.17A；",{"key":28,"text":458,"correct":22},"3.3075A；",{"key":31,"text":460,"correct":26},"3.5A。",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":20,"analysis":33},1021937,"某35kV线路全长为35km? 当全线为有架空地线的词杆双回线路时，下面电容电流正确的是（）。",[465,467,469,471],{"key":20,"text":466,"correct":22},"6.468A；",{"key":24,"text":468,"correct":26},"6.755A；",{"key":28,"text":470,"correct":26},"7.015A；",{"key":31,"text":472,"correct":26},"7.445A。",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":31,"analysis":33},1021938,"某35kV线路全长为35km? 当全线为无架空地线的同杆双线路时，下面电容电流正确的是（ ）。",[477,479,481,483],{"key":20,"text":478,"correct":26},"4.041A；",{"key":24,"text":480,"correct":26},"4.525A；",{"key":28,"text":482,"correct":26},"4.995A；",{"key":31,"text":484,"correct":22},"5.292A。",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":31,"analysis":33},1021939,"某电厂装机容量为25MW，发电机出口电压为6.3kV,cosψ=0.8。 发电机出口装设电流互感器应选用的型号规范为（）。",[489,491,493,495],{"key":20,"text":490,"correct":26},"LMZD2—10\u002F1500,一次额定电流为1500A；",{"key":24,"text":492,"correct":26},"LMZD2—10\u002F2000,一次额定电流为2000A；",{"key":28,"text":494,"correct":26},"LMZD2—10\u002F3000,一次颏定电流为3000A；",{"key":31,"text":496,"correct":22},"LMZD2—10\u002F4000,一次额定电流为4000A。",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":20,"analysis":33},1021940,"某电厂装机容量为25MW，发电机出口电压为6.3kV,cosψ=0.8。 发电机中性点装设电流互感器，电流互感器的变比应为（）。",[501,503,505,507],{"key":20,"text":502,"correct":22},"750\u002F5A；",{"key":24,"text":504,"correct":26},"1000\u002F5A；",{"key":28,"text":506,"correct":26},"1200\u002F5A；",{"key":31,"text":508,"correct":26},"1250\u002F5A。",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":28,"analysis":33},1021941,"某电厂装机容量为25MW，发电机出口电压为6.3kV,cosψ=0.8。 关于发电机的额定电流，下面数值正确的是（）。 A.2520A；",[513,515,517],{"key":20,"text":514,"correct":26},"2720A；",{"key":24,"text":516,"correct":26},"2863A；",{"key":28,"text":518,"correct":22},"3160",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":24,"analysis":33},1021942,"耐张绝缘子串采用X—4.5或XP—6型悬垂绝缘子。 在海拔髙度为1OOOm及以下的一级污秽地区，220kV耐张绝缘子串不宜少于（ ）。",[523,525,527,529],{"key":20,"text":524,"correct":26},"13片；",{"key":24,"text":526,"correct":22},"14片；",{"key":28,"text":528,"correct":26},"15片；",{"key":31,"text":530,"correct":26},"16片。",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":28,"analysis":33},1021943,"耐张绝缘子串采用X—4.5或XP—6型悬垂绝缘子。 在海拔高度为1OOOm及以下一级污秽地区，11OkV耐张绝缘子串不宜少于（）。",[535,537,539,541],{"key":20,"text":536,"correct":26},"6片；",{"key":24,"text":538,"correct":26},"7片；",{"key":28,"text":540,"correct":22},"8片;",{"key":31,"text":542,"correct":26},"9片。",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":31,"analysis":33},1021944,"耐张绝缘子串采用X—4.5或XP—6型悬垂绝缘子。 在海拔高度为3000m时，220kV耐张绝缘子串应为（ ）。",[547,548,549,551],{"key":20,"text":526,"correct":26},{"key":24,"text":528,"correct":26},{"key":28,"text":550,"correct":26},"16片；",{"key":31,"text":552,"correct":22},"17片。",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":31,"analysis":33},1021945,"耐张绝缘子串采用X—4.5或XP—6型悬垂绝缘子。 在海拔髙度为3500m时，11OkV耐张绝缘子串应为（ ）。",[557,559,561,563],{"key":20,"text":558,"correct":26},"7片,",{"key":24,"text":560,"correct":26},"8片；",{"key":28,"text":562,"correct":26},"9片；",{"key":31,"text":564,"correct":22},"10片",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":24,"analysis":33},1021946,"选用绝缘子应能承受污秽条件下的工频电压、操作过电压和雷电过电压. 在海拔高度11OOOm以下地区单片绝缘子的高度为146mm时，操作过电压和雷电过电压要求悬垂绝缘子串的绝缘子片在电压为11OkV时不应少于（）。",[569,570,571,572],{"key":20,"text":536,"correct":26},{"key":24,"text":538,"correct":22},{"key":28,"text":560,"correct":26},{"key":31,"text":542,"correct":26},{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":28,"analysis":33},1021947,"选用绝缘子应能承受污秽条件下的工频电压、操作过电压和雷电过电压. 在海拔高度1OOOm以下地区单片绝缘子的髙度为146mm时，操作过电压和雷电过电压要求悬垂绝缘子串的绝缘子片数，在电压为220kV时不应少于（）。",[577,579,581,582],{"key":20,"text":578,"correct":26},"11片；",{"key":24,"text":580,"correct":26},"12片；",{"key":28,"text":524,"correct":22},{"key":31,"text":583,"correct":26},"14片。",{"id":585,"libraryId":5,"type":15,"typeLabel":16,"stem":586,"options":587,"answer":24,"analysis":33},1021948,"选用绝缘子应能承受污秽条件下的工频电压、操作过电压和雷电过电压。 在海拔3000m的地区，单片绝缘子的髙度为146mm时，操作过电压和雷电过电压要求耐张绝缘子串的绝缘子片数，在电压为330kV时不应少于（）。",[588,590,592,594],{"key":20,"text":589,"correct":26},"21片；",{"key":24,"text":591,"correct":22},"22片；",{"key":28,"text":593,"correct":26},"23片；",{"key":31,"text":595,"correct":26},"24片。",{"id":597,"libraryId":5,"type":15,"typeLabel":16,"stem":598,"options":599,"answer":31,"analysis":33},1021949,"选用绝缘子应能承受污秽条件下的工频电压、操作过电压和雷电过电压. 在海拔3500m的地区，单片绝缘子的高度为146mm时，操作过电压和雷电过电压要求耐张绝缘子串的绝缘子片数，在电压为220kV时不应少于（）。",[600,601,602,604],{"key":20,"text":528,"correct":26},{"key":24,"text":550,"correct":26},{"key":28,"text":603,"correct":26},"17片；",{"key":31,"text":605,"correct":22},"18片，",[607,610,613,616,619,622],{"id":15,"name":608,"category":7,"favorite":609},"领导干部任职前廉政法规知识测试题",92,{"id":611,"name":612,"category":7,"favorite":15},595,"建筑结构与设备",{"id":614,"name":615,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":617,"name":618,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":620,"name":621,"category":7,"favorite":8},534,"BIM工程师",{"id":623,"name":621,"category":7,"favorite":8},535]