[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-34":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":609},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,34,50,2670,[13,34,46,58,70,82,94,106,118,129,141,149,157,169,181,193,205,217,229,241,253,265,277,289,301,313,325,336,348,360,372,384,396,408,418,430,442,454,466,478,490,502,514,525,537,549,561,573,585,597],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1023408,1,"单选题","某地区电力系统远景规划预测的最髙发电负荷为15000MW,负荷备用率取2%、事故备用率取10%、计划检修按8%，在扣除200MW受阻装机容量后，经电力平衡初步计算为供需平衡，可满足用电要求。 该系统需要装机容量是（）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","1620MW；",false,{"key":24,"text":25,"correct":22},"B","16500MW；",{"key":27,"text":28,"correct":22},"C","15300MW；",{"key":30,"text":31,"correct":32},"D","18000MW。",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1023409,"某地区电力系统远景规划预测的最髙发电负荷为15000MW,负荷备用率取2%、事故备用率取10%、计划检修按8%，在扣除200MW受阻装机容量后，经电力平衡初步计算为供需平衡，可满足用电要求。 本系统实际规划总装机容量是（）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"16400MW；",{"key":24,"text":41,"correct":32},"18200MW；",{"key":27,"text":43,"correct":22},"16700MW；",{"key":30,"text":45,"correct":22},"15500MW。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},1023410,"某电力系统为纯燃煤火电运行系统，无水电等其他电源，电源装机总容量（注：无受阻容量）是系统最髙发电负荷的1.3倍。另外，发电机組最低（最小）技术功率为50%，电力负荷日最小负荷率全年都不小于70外。 以下说法正确的是（）。",[50,52,54,56],{"key":20,"text":51,"correct":32},"电力电量平衡可得到保证；",{"key":24,"text":53,"correct":22},"电力平衡可得到保证，电量得不到保证；",{"key":27,"text":55,"correct":22},"电力平衡得不到保证，电量可得到保证；",{"key":30,"text":57,"correct":22},"电力电量平衡均得不到保证。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},1023411,"某电力系统为纯燃煤火电运行系统，无水电等其他电源，电源装机总容量（注：无受阻容量）是系统最髙发电负荷的1.3倍。另外，发电机組最低（最小）技术功率为50%，电力负荷日最小负荷率全年都不小于70外。 关于调峰问题，下面说法不正确的是（）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"能适应负荷变动的需要和满足调冷要求；",{"key":24,"text":65,"correct":32},"不能适应负荷变动的需要，也不能满足调峰要求；",{"key":27,"text":67,"correct":22},"火电调峰幅度大于负荷变动范围，不存在调峰困难问題；",{"key":30,"text":69,"correct":22},"汽轮发电机组调节性能既可以担任基荷和腰荷，也可以担任峰荷。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},1023412,"某大区电力系统按发电能源种类分电源有水电（包括抽水蓄能电站）、火电（包括煤电、天然气和油电厂）及核电站，暂无其他新能源发电的电厂（如风力、太阳能等），请分析回答以下问题。 抽水蓄能电站在电力系统中的主要作用，下面（）说法是不合理的。",[74,76,78,80],{"key":20,"text":75,"correct":32},"担任基本负荷；",{"key":24,"text":77,"correct":22},"担任调峰负荷；",{"key":27,"text":79,"correct":22},"吸收低谷电量（也叫填谷）；",{"key":30,"text":81,"correct":22},"担任系统短时备用。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":27,"analysis":33},1023413,"某大区电力系统按发电能源种类分电源有水电（包括抽水蓄能电站）、火电（包括煤电、天然气和油电厂）及核电站，暂无其他新能源发电的电厂（如风力、太阳能等），请分析回答以下问题。 关于各类电厂分工（即在电力系统中的工作位置）原则，不正确的是（）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"峰荷：由具有调节水库的水电站、火电厂中的调峰机组和燃气轮机等电厂承担；",{"key":24,"text":89,"correct":22},"腰荷：由腰荷火电厂、引水道较长且调节池较小的水电站、抽汽供热机組的凝汽发电部分等承担；",{"key":27,"text":91,"correct":32},"基荷：由基荷火电厂、核电站、热电厂（供热强制出力）、径流水电站和水电站（为灌溉、航运等综合利用放水发出）的强制出力，以及抽水蓄能电站等承担；",{"key":30,"text":93,"correct":22},"填谷负荷：由抽水蓄能电站承担。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},1023414,"某煤电联营坑口火力发电厂，采用交流500kV电压等级、二回出线将电厂电力送到受端负荷中心变电所，送电线路长度（L）250km,每公里电容 （C）0.0126336 F，为限制工頻过电压和潜供电流要在每条500kV线路受端侧装设150Mvar髙压并联电抗器。请分析和计算以下问题。 按电网最高工作电压计算，线路每公里充电功率（Qc）是（），",[98,100,102,104],{"key":20,"text":99,"correct":32},"1.20Mvar；",{"key":24,"text":101,"correct":22},"1.1OMvar；",{"key":27,"text":103,"correct":22},"1.OOMvar；",{"key":30,"text":105,"correct":22},"0.90Mvar。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},1023415,"某煤电联营坑口火力发电厂，采用交流500kV电压等级、二回出线将电厂电力送到受端负荷中心变电所，送电线路长度（L）250km,每公里电容 （C）0.0126336 F，为限制工頻过电压和潜供电流要在每条500kV线路受端侧装设150Mvar髙压并联电抗器。请分析和计算以下问题。 电厂二回5OOkV出线线路总充电功率（QcΣ）是（）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"500Mvar；",{"key":24,"text":113,"correct":32},"600Mvar；",{"key":27,"text":115,"correct":22},"700Mvar；",{"key":30,"text":117,"correct":22},"400Mvar。",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":27,"analysis":33},1023416,"某煤电联营坑口火力发电厂，采用交流500kV电压等级、二回出线将电厂电力送到受端负荷中心变电所，送电线路长度（L）250km,每公里电容 （C）0.0126336 F，为限制工頻过电压和潜供电流要在每条500kV线路受端侧装设150Mvar髙压并联电抗器。请分析和计算以下问题。 —般情况下采用高、低压并联电抗器容量（QLΣ）为（）来补偿线路充电功率，才能符合《电力系统电压和无功电力技术导则》（SD325—1989）要求。",[122,124,125,127],{"key":20,"text":123,"correct":22},"420Mvar；",{"key":24,"text":113,"correct":22},{"key":27,"text":126,"correct":32},"540Mvar；",{"key":30,"text":128,"correct":22},"480Mvar。",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":30,"analysis":33},1023417,"某±500kV直流线路，试根据规程规定回答下列问题。 靠近±500kV直流线路的民房拆迁标准，下述不符合的是（）。",[133,135,137,139],{"key":20,"text":134,"correct":22},"导线最大弧善风偏后与民房的最小距离为8.5m；",{"key":24,"text":136,"correct":22},"民房所在地的地表未畸变合成场强不超过30kV\u002Fm；",{"key":27,"text":138,"correct":22},"导线风偏后与民房的水平距离不小于8.5m；",{"key":30,"text":140,"correct":32},"民房所在地的离子流小于1OOnA。",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":30,"analysis":33},1023418,"某超髙压送电线路，试根据下列给定条件判断。 该线路假设为B类区，参照机场（A类区）风速记录，但塔台风速仪高度距地表为30m，其风速换算到线路髙度1Om时为（）。",[145,146,147,148],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":32},{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":27,"analysis":33},1023419,"某超髙压送电线路，试根据下列给定条件判断。 分别列出110、220、500kV频率为1MHz时，高压交流架空送电线无线电干扰限值dB（μV\u002Fm）为（）（距边导线20m处）。",[153,154,155,156],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":32},{"key":30,"text":30,"correct":22},{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":20,"analysis":33},1023420,"某超髙压送电线路，试根据下列给定条件判断。 架空避雷线对导线的保护角变小时，防雷保护的效果（）。",[161,163,165,167],{"key":20,"text":162,"correct":32},"变好；",{"key":24,"text":164,"correct":22},"变差；",{"key":27,"text":166,"correct":22},"无明显变化；",{"key":30,"text":168,"correct":22},"根据地形确定，",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":20,"analysis":33},1023421,"某超髙压送电线路，试根据下列给定条件判断。 计算频率为0.8MHz时，500kV线路的无线电干扰限值（距边导线投影20m）为（）dB（μV\u002Fm）。",[173,175,177,179],{"key":20,"text":174,"correct":32},"52；",{"key":24,"text":176,"correct":22},"48；",{"key":27,"text":178,"correct":22},"50；",{"key":30,"text":180,"correct":22},"54。",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":30,"analysis":33},1023422,"某超髙压送电线路，试根据下列给定条件判断。 某220kV双回同塔线路，按垂直同相序排列，悬垂绝缘子串长为2.5m，最大弧垂16m,求不同回路间相导线的最小水平线距为（）。",[185,187,189,191],{"key":20,"text":186,"correct":22},"5.6m；",{"key":24,"text":188,"correct":22},"4.6m；",{"key":27,"text":190,"correct":22},"4.1m；",{"key":30,"text":192,"correct":32},"6.1m。",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":27,"analysis":33},1023423,"某超髙压送电线路，试根据下列给定条件判断。 导线为双分裂（2XLGJ-240\u002F55）,子导线垂直排列，不用间隔棒，若档距500m，用防振锤保护，每档每端安装数量为（）。",[197,199,201,203],{"key":20,"text":198,"correct":22},"不必安装；",{"key":24,"text":200,"correct":22},"1个；",{"key":27,"text":202,"correct":32},"2个；",{"key":30,"text":204,"correct":22},"3个，",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":24,"analysis":33},1023424,"某超髙压送电线路，试根据下列给定条件判断。 定位中要检查耐张绝缘子的允许荷载是否大于导线张力，设该档两悬挂点高差为80m,两点至导线最低点的弧垂为10m，导线最低点张力为40kN,导线重量为1.633kg\u002Fm,计算导线悬挂点张力为（）。",[209,211,213,215],{"key":20,"text":210,"correct":22},"41.51kN；",{"key":24,"text":212,"correct":32},"41.44kV；",{"key":27,"text":214,"correct":22},"40.15kN；",{"key":30,"text":216,"correct":22},"40.48kN。",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":27,"analysis":33},1023425,"某山区大型水电站，拟用500kV线路送出，预期毎回线路的最大输送功率为1100MW,COSφ=O.9年最大负荷利用小时数为5OOOh,假设经济电流密度取0.9A\u002Fmm2,试选择导线： 相导线铝截面应为（ ）mm2。",[221,223,225,227],{"key":20,"text":222,"correct":22},"1400；",{"key":24,"text":224,"correct":22},"1500；",{"key":27,"text":226,"correct":32},"1570；",{"key":30,"text":228,"correct":22},"1700。",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":30,"analysis":33},1023426,"某山区大型水电站，拟用500kV线路送出，预期毎回线路的最大输送功率为1100MW,COSφ=O.9年最大负荷利用小时数为5OOOh,假设经济电流密度取0.9A\u002Fmm2,试选择导线： 宜选用导线的分裂方式（）。",[233,235,237,239],{"key":20,"text":234,"correct":22},"2X800；",{"key":24,"text":236,"correct":22},"3X500；",{"key":27,"text":238,"correct":22},"3X630；",{"key":30,"text":240,"correct":32},"4X400。",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":27,"analysis":33},1023427,"某山区大型水电站，拟用500kV线路送出，预期毎回线路的最大输送功率为1100MW,COSφ=O.9年最大负荷利用小时数为5OOOh,假设经济电流密度取0.9A\u002Fmm2,试选择导线： 宜选用的钢芯铝绞线型号（）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"4XLGJ-400\u002F20；",{"key":24,"text":248,"correct":22},"4XLGJ-400\u002F35；",{"key":27,"text":250,"correct":32},"4XLGJ-400\u002F50,",{"key":30,"text":252,"correct":22},"4XLGJ—400\u002F95。",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":24,"analysis":33},1023428,"某220kV单回线路，导线为LGJ —400\u002F50（d0=27.63mm）,三相水平排列，相间距离6.5m，避雷线为双根钢绞线，计算： 单位长（km）正序电抗为（）。",[257,259,261,263],{"key":20,"text":258,"correct":22},"0.355；",{"key":24,"text":260,"correct":32},"0.415；",{"key":27,"text":262,"correct":22},"0.435；",{"key":30,"text":264,"correct":22},"0.44。",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":27,"analysis":33},1023429,"某220kV单回线路，导线为LGJ —400\u002F50（d0=27.63mm）,三相水平排列，相间距离6.5m，避雷线为双根钢绞线，计算： 单位长（km）零序电抗为（）。",[269,271,273,275],{"key":20,"text":270,"correct":22},"1.1；",{"key":24,"text":272,"correct":22},"1.12；",{"key":27,"text":274,"correct":32},"1.245；",{"key":30,"text":276,"correct":22},"1.305。",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":24,"analysis":33},1023430,"某220kV单回线路，导线为LGJ —400\u002F50（d0=27.63mm）,三相水平排列，相间距离6.5m，避雷线为双根钢绞线，计算： 若将避雷线改为良导体，其零序电抗约为（）。",[281,283,285,287],{"key":20,"text":282,"correct":22},"0.8；",{"key":24,"text":284,"correct":32},"0.83；",{"key":27,"text":286,"correct":22},"1.O1；",{"key":30,"text":288,"correct":22},"1.11。",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":27,"analysis":33},1023431,"某220kV单回线路，导线为LGJ —400\u002F50（d0=27.63mm）,三相水平排列，相间距离6.5m，避雷线为双根钢绞线，计算： 若该线路不架设避雷线，其零序电抗约为（）。",[293,295,297,299],{"key":20,"text":294,"correct":22},"1.35；",{"key":24,"text":296,"correct":22},"1.403,",{"key":27,"text":298,"correct":32},"1.4525,",{"key":30,"text":300,"correct":22},"1.55.",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":24,"analysis":33},1023433,"某330kV单回线路，导线为2X LGJ—400\u002F50（d0=27.63mm）双分裂，分裂间距为0.4m,导线水平排列，相间距离8m，计算： 线路单位长度的零序电抗（）（约值）Ω\u002Fkm。",[305,307,309,311],{"key":20,"text":306,"correct":22},"0.888；",{"key":24,"text":308,"correct":32},"O.948；",{"key":27,"text":310,"correct":22},"1.13；",{"key":30,"text":312,"correct":22},"1.25。",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":27,"analysis":33},1023434,"某330kV单回线路，导线为2X LGJ—400\u002F50（d0=27.63mm）双分裂，分裂间距为0.4m,导线水平排列，相间距离8m，计算： 线路若按同规格同塔双回线架设，则零序电抗大约为正序电抗值的（）倍。",[317,319,321,323],{"key":20,"text":318,"correct":22},"3.5；",{"key":24,"text":320,"correct":22},"4.0；",{"key":27,"text":322,"correct":32},"4.7；",{"key":30,"text":324,"correct":22},"5.0。",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":27,"analysis":33},1023435,"某330kV单回线路，导线为2X LGJ—400\u002F50（d0=27.63mm）双分裂，分裂间距为0.4m,导线水平排列，相间距离8m，计算： 若该线路未架设避雷线，其零序电抗大约为正序电抗值的（）倍。",[329,331,333,334],{"key":20,"text":330,"correct":22},"2.0；",{"key":24,"text":332,"correct":22},"2.5；",{"key":27,"text":318,"correct":32},{"key":30,"text":335,"correct":22},"5.5。",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":20,"analysis":33},1023436,"某110kV单回线路，导线为LGJ—400\u002F50（d0=27.63mm）,三相水平排列，相间距离为4.5m，平均对地高度为10m，请计算： 该线单位长度正序电容（）F\u002Fkm。",[340,342,344,346],{"key":20,"text":341,"correct":32},"0.00923X10-6；",{"key":24,"text":343,"correct":22},"0.015X10—6；",{"key":27,"text":345,"correct":22},"O.15X10-6；",{"key":30,"text":347,"correct":22},"0.9X10-6。",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":24,"analysis":33},1023437,"某110kV单回线路，导线为LGJ—400\u002F50（d0=27.63mm）,三相水平排列，相间距离为4.5m，平均对地高度为10m，请计算： 该线单位长度正序电纳（）S\u002Fkm。",[352,354,356,358],{"key":20,"text":353,"correct":22},"2.OX1O-6；",{"key":24,"text":355,"correct":32},"2.899X10—6；",{"key":27,"text":357,"correct":22},"3.5X10-6；",{"key":30,"text":359,"correct":22},"5X10-6。",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":24,"analysis":33},1023438,"某110kV单回线路，导线为LGJ—400\u002F50（d0=27.63mm）,三相水平排列，相间距离为4.5m，平均对地高度为10m，请计算： 该线单位长度零序电容（）F\u002Fkm。",[364,366,368,370],{"key":20,"text":365,"correct":22},"0.004X1O-6；",{"key":24,"text":367,"correct":32},"0.0056X1O-6；",{"key":27,"text":369,"correct":22},"0.008X1O-6；",{"key":30,"text":371,"correct":22},"0.009X10-6。",{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":27,"analysis":33},1023439,"某110kV单回线路，导线为LGJ—400\u002F50（d0=27.63mm）,三相水平排列，相间距离为4.5m，平均对地高度为10m，请计算： 该线单位长度零序电纳（）S\u002Fkm。",[376,378,380,382],{"key":20,"text":377,"correct":22},"1.6X10-6；",{"key":24,"text":379,"correct":22},"1.70X10—6；",{"key":27,"text":381,"correct":32},"1.759X10-6；",{"key":30,"text":383,"correct":22},"2.06X10-6。",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":24,"analysis":33},1023440,"为了解超高压和特高压线路电晕放电现象需计算导线表面电场强度及电晕临界电场强度。其比值是导线电晕及电晕损失的基本判据。如某5OOkV超高压单回线路，导线为4XLGJ-400\u002F50（d0=27.63mm）,正方形排列，导线间距0.45m,相间距离12m’水平排列，导线对地平均高度为15m。最髙运行电压525kV，平均正序电容（边相）为0.013Xl0-6 F\u002Fkm试计算： 平均电场强度（边相）有效值（）MV\u002Fm。",[388,390,392,394],{"key":20,"text":389,"correct":22},"1.20；",{"key":24,"text":391,"correct":32},"1.28；",{"key":27,"text":393,"correct":22},"1.33；",{"key":30,"text":395,"correct":22},"1.40。",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":20,"analysis":33},1023441,"为了解超高压和特高压线路电晕放电现象需计算导线表面电场强度及电晕临界电场强度。其比值是导线电晕及电晕损失的基本判据。如某5OOkV超高压单回线路，导线为4XLGJ-400\u002F50（d0=27.63mm）,正方形排列，导线间距0.45m,相间距离12m’水平排列，导线对地平均高度为15m。最髙运行电压525kV，平均正序电容（边相）为0.013Xl0-6 F\u002Fkm试计算： 平均电场强度（边相）最大值（）MV\u002Fm。",[400,402,404,406],{"key":20,"text":401,"correct":32},"1.81；",{"key":24,"text":403,"correct":22},"1.85；",{"key":27,"text":405,"correct":22},"1.95；",{"key":30,"text":407,"correct":22},"2.O。",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":27,"analysis":33},1023442,"为了解超高压和特高压线路电晕放电现象需计算导线表面电场强度及电晕临界电场强度。其比值是导线电晕及电晕损失的基本判据。如某5OOkV超高压单回线路，导线为4XLGJ-400\u002F50（d0=27.63mm）,正方形排列，导线间距0.45m,相间距离12m’水平排列，导线对地平均高度为15m。最髙运行电压525kV，平均正序电容（边相）为0.013Xl0-6 F\u002Fkm试计算： 导线最大电场强度约为（）MV\u002Fm。",[412,414,415,417],{"key":20,"text":413,"correct":22},"1.8;",{"key":24,"text":403,"correct":22},{"key":27,"text":416,"correct":32},"1.94；",{"key":30,"text":407,"correct":22},{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":30,"analysis":33},1023443,"为了解超高压和特高压线路电晕放电现象需计算导线表面电场强度及电晕临界电场强度。其比值是导线电晕及电晕损失的基本判据。如某5OOkV超高压单回线路，导线为4XLGJ-400\u002F50（d0=27.63mm）,正方形排列，导线间距0.45m,相间距离12m’水平排列，导线对地平均高度为15m。最髙运行电压525kV，平均正序电容（边相）为0.013Xl0-6 F\u002Fkm试计算： 在标准气象条件下（气压P=1O1. 325X1O3Pa,气温t=20℃，相对空气密度δ=1）,该导线的电晕临界电场强度为（）MV\u002Fm。",[422,424,426,428],{"key":20,"text":423,"correct":22},"2.9；",{"key":24,"text":425,"correct":22},"2.96；",{"key":27,"text":427,"correct":22},"3.O1；",{"key":30,"text":429,"correct":32},"3.12。",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":20,"analysis":33},1023444,"在忽略线路的电阻损失后，送电线路的波阻抗及自然功率是判断线路输电能力的重要参数。当线路输送自然功率时，沿全线的电压、电流数值均保持不变，线路产生的无功和消耗的无功相抵消。线路输送功率大于自然功率时，送端电压高于受端电压。线路无功损耗由系统供给。下面请计算： 某220kV单回线路，导线LGJ —400\u002F50，单位长度正序电感0.133X10-2H\u002Fkm,正序电容0.00867X10-6F\u002Fkm，其波阻抗为（）Ω。",[434,436,438,440],{"key":20,"text":435,"correct":32},"392；",{"key":24,"text":437,"correct":22},"400；",{"key":27,"text":439,"correct":22},"410；",{"key":30,"text":441,"correct":22},"420。",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":24,"analysis":33},1023445,"在忽略线路的电阻损失后，送电线路的波阻抗及自然功率是判断线路输电能力的重要参数。当线路输送自然功率时，沿全线的电压、电流数值均保持不变，线路产生的无功和消耗的无功相抵消。线路输送功率大于自然功率时，送端电压高于受端电压。线路无功损耗由系统供给。下面请计算： 同（1）题参数其自然输送功率应为（）MW。",[446,448,450,452],{"key":20,"text":447,"correct":22},"120；",{"key":24,"text":449,"correct":32},"123.5；",{"key":27,"text":451,"correct":22},"130；",{"key":30,"text":453,"correct":22},"135。",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":24,"analysis":33},1023446,"在忽略线路的电阻损失后，送电线路的波阻抗及自然功率是判断线路输电能力的重要参数。当线路输送自然功率时，沿全线的电压、电流数值均保持不变，线路产生的无功和消耗的无功相抵消。线路输送功率大于自然功率时，送端电压高于受端电压。线路无功损耗由系统供给。下面请计算： 某500kV单回送电线路，导线4X LGJ—400\u002F50，其单位长度正序电感0.0918X1O-2H\u002Fkm,正序电容0.013X10-6F\u002Fkm,线路波阻抗为（）Ω。",[458,460,462,464],{"key":20,"text":459,"correct":22},"255；",{"key":24,"text":461,"correct":32},"266；",{"key":27,"text":463,"correct":22},"285；",{"key":30,"text":465,"correct":22},"300。",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":30,"analysis":33},1023447,"在忽略线路的电阻损失后，送电线路的波阻抗及自然功率是判断线路输电能力的重要参数。当线路输送自然功率时，沿全线的电压、电流数值均保持不变，线路产生的无功和消耗的无功相抵消。线路输送功率大于自然功率时，送端电压高于受端电压。线路无功损耗由系统供给。下面请计算： 同（3）题参数，该线路自然输送功率为（）MW。",[470,472,474,476],{"key":20,"text":471,"correct":22},"810；",{"key":24,"text":473,"correct":22},"850；",{"key":27,"text":475,"correct":22},"900；",{"key":30,"text":477,"correct":32},"940。",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":27,"analysis":33},1023448,"某220kV线路，某地段穿越海拔2200m的高原地区，为了该段线路的绝缘配合及塔头请核算：",[482,484,486,488],{"key":20,"text":483,"correct":22},"该段线路若选用片高146mm的标准绝缘子，其悬垂绝缘子片的片数为（）。",{"key":24,"text":485,"correct":22},"13；",{"key":27,"text":487,"correct":32},"14； C15；",{"key":30,"text":489,"correct":22},"16。",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":30,"analysis":33},1023449,"某220kV线路，某地段穿越海拔2200m的高原地区，为了该段线路的绝缘配合及塔头请核算： 该段线路操作过电压的间隙值为（）m。",[494,496,498,500],{"key":20,"text":495,"correct":22},"1.45；",{"key":24,"text":497,"correct":22},"1.55；",{"key":27,"text":499,"correct":22},"1.65；",{"key":30,"text":501,"correct":32},"1.624。",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":27,"analysis":33},1023450,"某220kV线路，某地段穿越海拔2200m的高原地区，为了该段线路的绝缘配合及塔头请核算： 该段线路工作电压的间隙值为（）m。",[506,508,510,512],{"key":20,"text":507,"correct":22},"0.55；",{"key":24,"text":509,"correct":22},"0.58；",{"key":27,"text":511,"correct":32},"0.62；",{"key":30,"text":513,"correct":22},"0.65,",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":30,"analysis":33},1023451,"某220kV线路，某地段穿越海拔2200m的高原地区，为了该段线路的绝缘配合及塔头请核算： 该段线路雷电过电压间隙值为（）m。",[518,520,521,523],{"key":20,"text":519,"correct":22},"1.9；",{"key":24,"text":330,"correct":22},{"key":27,"text":522,"correct":22},"2.1；",{"key":30,"text":524,"correct":32},"2.2。",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":27,"analysis":33},1023452,"有一额定电压为500kV的输电网，已知500kV输电线路使用4XLGJQ-300型分裂导线，长度为100km。其电气参数电阻R=2.4Ω、电抗X=28Ω、充电功率Q=1OOMvar如图13所示。 电源侧A母线送出的功率为（）。",[529,531,533,535],{"key":20,"text":530,"correct":22},"1058.45MW、130.18Mvar；",{"key":24,"text":532,"correct":22},"1608.65MW、49.16Mvar；",{"key":27,"text":534,"correct":32},"1111.9MW、248.4Mvar；",{"key":30,"text":536,"correct":22},"1268.45MW、84.18Mvar。",{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":20,"analysis":33},1023453,"有一额定电压为500kV的输电网，已知500kV输电线路使用4XLGJQ-300型分裂导线，长度为100km。其电气参数电阻R=2.4Ω、电抗X=28Ω、充电功率Q=1OOMvar如图13所示。 B点电压为（）。",[541,543,545,547],{"key":20,"text":542,"correct":32},"494∠-6.8°；",{"key":24,"text":544,"correct":22},"504.49∠-1.87°；",{"key":27,"text":546,"correct":22},"524.49∠-2.87°；",{"key":30,"text":548,"correct":22},"501∠-3.87°。",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":20,"analysis":33},1023454,"某单端供电220kV电网如图14所示，AB线路A侧、BC线路B侧、BD线路B侧分别配置有三段式相间距离保护。 已知：可靠系数k=0.8,k'=0.8,k2=1时间级差△t=0.5，II段与相邻线路I段配合，灵敏系数km≥1.5，不考虑振荡闭锁和负荷电流的影响。 求：AB线路A侧相间距离保护I段的定值，即AB线路A侧、BC线路B侧、BD线路B侧距离保护的定值分别为（）Ω。",[553,555,557,559],{"key":20,"text":554,"correct":32},"8、16、12；",{"key":24,"text":556,"correct":22},"8、14、12；",{"key":27,"text":558,"correct":22},"8,16、14；",{"key":30,"text":560,"correct":22},"12、16、14。",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":24,"analysis":33},1023455,"某单端供电220kV电网如图14所示，AB线路A侧、BC线路B侧、BD线路B侧分别配置有三段式相间距离保护。 已知：可靠系数k=0.8,k'=0.8,k2=1时间级差△t=0.5，II段与相邻线路I段配合，灵敏系数km≥1.5，不考虑振荡闭锁和负荷电流的影响。 已知ZAB=8Ω、ZBc=16Ω、ZBD =12Ω，求：AB线路A侧相间距离保护II段的定值为（）。",[565,567,569,571],{"key":20,"text":566,"correct":22},"17.6Ω；",{"key":24,"text":568,"correct":32},"16Ω；",{"key":27,"text":570,"correct":22},"18.6Ω；",{"key":30,"text":572,"correct":22},"19.2Ω。",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":27,"analysis":33},1023456,"某新建220kV枢纽开关站220kV电气主接线示意图如图15所示。 已知：下面开列了一些保护柜的名称，线路1回路上标示出详细的电流互感器二次绕组及编号。站内仅有一个继电器室。 根据《继电保护和安全自动装置技术规程》（GB 14825—2006）,从表中选择可适用的保护柜的名字，母线保护柜按双重化配置，并且统计出需要的每种保护柜（线路保护柜、母线保护柜、故障录波器柜）的合理数量为（）。",[577,579,581,583],{"key":20,"text":578,"correct":22},"2、.6、1；",{"key":24,"text":580,"correct":22},"8、4、2；",{"key":27,"text":582,"correct":32},"6、2、1；",{"key":30,"text":584,"correct":22},"4、2、1。",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":30,"analysis":33},1023457,"某新建220kV枢纽开关站220kV电气主接线示意图如图15所示。 已知：下面开列了一些保护柜的名称，线路1回路上标示出详细的电流互感器二次绕组及编号。站内仅有一个继电器室。 根据图15中的电流互感器回路二次绕组布置图，确定线路保护和母线保护使用的电流互感器二次绕组编号（L2、L3、L4、L5）为（）。",[589,591,593,595],{"key":20,"text":590,"correct":22},"线路保护柜、母线保护柜、母线保护柜、线路保护柜；",{"key":24,"text":592,"correct":22},"母线保护柜、线路保护柜、母线保护柜、线路保护柜；",{"key":27,"text":594,"correct":22},"母线保护柜、线路保护柜、线路保护柜、母线保护柜；",{"key":30,"text":596,"correct":32},"母线保护柜、母线保护柜、线路保护柜、线路保护柜。",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":27,"analysis":33},1023458,"图16是一个500kV电网图，AB线上的故障切除时间必须控制在100ms以内（含100ms）,才能保证500kV电网稳定运行。 请从图16中确定A站与B站之间的AB线路的主保护为（）。",[601,603,605,607],{"key":20,"text":602,"correct":22},"距离I段保护+距离II段保护；",{"key":24,"text":604,"correct":22},"方向零序电流I段保护+方向零序电流II段保护；",{"key":27,"text":606,"correct":32},"分相电流差动保护+高頻距离保护；",{"key":30,"text":608,"correct":22},"短引线保护+断路器失灵保护。",[610,613,616,619,622,625],{"id":15,"name":611,"category":7,"favorite":612},"领导干部任职前廉政法规知识测试题",92,{"id":614,"name":615,"category":7,"favorite":15},595,"建筑结构与设备",{"id":617,"name":618,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":620,"name":621,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":623,"name":624,"category":7,"favorite":8},534,"BIM工程师",{"id":626,"name":624,"category":7,"favorite":8},535]