[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-30":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":585},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,30,50,2670,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,189,201,213,225,233,241,253,265,277,289,301,313,325,333,345,356,366,378,390,402,414,426,438,450,461,473,481,493,501,512,523,534,543,552,561,573],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1023207,1,"单选题","由于铝股线直径越小，强度越高，而铝线股数越多，强度损失系数越大，故铝绞线计算拉断力与股数和股径有关。 铝绞线 LJ一630（结构61\u002F3.63）σ0=162N\u002Fmm2,其抗拉强度为（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","85000N；",false,{"key":24,"text":25,"correct":26},"B","92000N；",true,{"key":28,"text":29,"correct":22},"C","97000N；",{"key":31,"text":32,"correct":22},"D","105000N。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},1023208,"钢芯招绞线的强度，由铝绞强度总和加钢丝1%伸长时的强度总和组成。 钢芯话绞线 LGJ300\u002F25（结构为铝48\u002F2.85，钢7\u002F2.22）。σ0=169N\u002Fmm2,=1172，其拉断力应为（）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"83500N；",{"key":24,"text":41,"correct":22},"84100N；",{"key":28,"text":43,"correct":22},"84600N；",{"key":31,"text":45,"correct":22},"85100N。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},1023209,"钢芯招绞线的强度，由铝绞强度总和加钢丝1%伸长时的强度总和组成。 钢芯铝绞线 LGJ300\u002F70（结构为铝30\u002F3.6，钢7\u002F3.6），σ0=162N\u002Fmm2,σ1%=1103，其拉断力应为（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"11OOOON；",{"key":24,"text":53,"correct":22},"115000N；",{"key":28,"text":55,"correct":22},"120000N；",{"key":31,"text":57,"correct":26},"128000N。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},1023210,"钢绞线破断拉力等于钢丝破断拉力总和乘以换算系数。",[62,64,66,68],{"key":20,"text":63,"correct":22},"110kV线路地线常用GJ—50，其结构为7\u002F3.0，截面49.46mm2，地线钢丝的公称抗拉强度一般选用1270N\u002Fmm2级。其破断拉力为（）。",{"key":24,"text":65,"correct":26},"51600N；",{"key":28,"text":67,"correct":22},"57790N； C61000N；",{"key":31,"text":69,"correct":22},"62150N。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},1023211,"钢绞线破断拉力等于钢丝破断拉力总和乘以换算系数。 220kV及以上线路地线常用GJ—70，其结构为19\u002F2.2，截面72.19mm2,地线钢丝的公称抗拉强度一般选用1270N\u002Fmm2级。其破断拉力为（）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"79500N；",{"key":24,"text":77,"correct":22},"81000N；",{"key":28,"text":79,"correct":26},"82520N；",{"key":31,"text":81,"correct":22},"8325GN。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},1023212,"线路上有各种杆塔用于各种档距，但其导线是相同的，故每米电线的荷载是相同的，该荷载称为电线的单位荷载，用于各种杆塔和绝缘子串的荷载计算。各种电线标称截面很多，拉断力各异，但其拉断应力是一致的，如铝绞线约157N\u002Fmm2，钢绞线约1175N\u002Fmm2,轻型钢芯铝绞线约245N\u002Fmm2，正常型钢芯铝纹线约275N\u002Fmm2，加强型钢芯铝绞线约305N\u002Fmm2。故电线的力学计算与其他结构计算一样，用应力作计算参数，故将单位荷载换算到电线每平方毫米上的荷载，称为比荷载，简称比载。 表征电线垂直荷载或比载有以下各种，其中不是的为（）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"电线自重；",{"key":24,"text":89,"correct":22},"电线覆冰的冰重；",{"key":28,"text":91,"correct":22},"分裂导线间隔棒重或覆冰间隔棒重；",{"key":31,"text":93,"correct":26},"电线振动荷载。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},1023213,"线路上有各种杆塔用于各种档距，但其导线是相同的，故每米电线的荷载是相同的，该荷载称为电线的单位荷载，用于各种杆塔和绝缘子串的荷载计算。各种电线标称截面很多，拉断力各异，但其拉断应力是一致的，如铝绞线约157N\u002Fmm2，钢绞线约1175N\u002Fmm2,轻型钢芯铝绞线约245N\u002Fmm2，正常型钢芯铝纹线约275N\u002Fmm2，加强型钢芯铝绞线约305N\u002Fmm2。故电线的力学计算与其他结构计算一样，用应力作计算参数，故将单位荷载换算到电线每平方毫米上的荷载，称为比荷载，简称比载。 表征电线横向荷载或比载有以下各种，其中不是的为（）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"电线风荷载；",{"key":24,"text":101,"correct":22},"覆冰电线的风荷载；",{"key":28,"text":103,"correct":26},"电线摆动荷载；",{"key":31,"text":105,"correct":22},"分裂导线间隔棒或覆冰间隔棒风荷载，",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},1023214,"线路上有各种杆塔用于各种档距，但其导线是相同的，故每米电线的荷载是相同的，该荷载称为电线的单位荷载，用于各种杆塔和绝缘子串的荷载计算。各种电线标称截面很多，拉断力各异，但其拉断应力是一致的，如铝绞线约157N\u002Fmm2，钢绞线约1175N\u002Fmm2,轻型钢芯铝绞线约245N\u002Fmm2，正常型钢芯铝纹线约275N\u002Fmm2，加强型钢芯铝绞线约305N\u002Fmm2。故电线的力学计算与其他结构计算一样，用应力作计算参数，故将单位荷载换算到电线每平方毫米上的荷载，称为比荷载，简称比载。 表征电线荷载向量和的综合比载有以下各种，不正确的是（）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"电线自重加电线风荷载；",{"key":24,"text":113,"correct":22},"覆冰电线重加瘦冰电线风荷载；",{"key":28,"text":115,"correct":22},"电线自重加电线覆冰重；",{"key":31,"text":117,"correct":26},"覆冰电线重加电线风荷载。",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},1023215,"电线自重比载A为电线自重g, （kg\u002Fm）除截面积A（mm2）。 LGJ-300\u002F25总截面333.31mm2。自重1.058kg\u002Fm,其自重比载为（），",[122,124,126,128],{"key":20,"text":123,"correct":22},"2.91X10-2；",{"key":24,"text":125,"correct":26},"3.11XlO-2；",{"key":28,"text":127,"correct":22},"3.22X10-2；",{"key":31,"text":129,"correct":22},"3.31X10-2。",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":28,"analysis":33},1023216,"电线自重比载A为电线自重g, （kg\u002Fm）除截面积A（mm2）。 LGJ—300\u002F50总截面348.36mm2。自重1.21kg\u002Fm,其自重比载为（）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"3.21X10—2；",{"key":24,"text":137,"correct":22},"3.11X1O-2；",{"key":28,"text":139,"correct":26},"3.40X10-2；",{"key":31,"text":141,"correct":22},"3.45X10-2。",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":28,"analysis":33},1023217,"电线覆冰有湿雪、雾淞、雨淞，比重从0.2~0.9。电线覆冰形状受风的影响，会呈现出千奇百怪的样子，一般迎风面较大，但是偏心使电线扭转，从而覆冰包严电线电线设计冰厚（W是将其折算为比重0.9的正圆筒。因此，电线覆冰单位荷载（kg\u002Fm）的计算， 要先算出内径为d（mm）,外径为d+26（mm）,1m冰筒的体积，公式为π\u002F4[(d+2b）2-d2]=π（b+d）b（cm3）,再乘以冰的比重0.9，即得单位冰荷重P2（g）。 LGJ—300\u002F50，d=24.26mm,A=348.36mm2,1Omm冰区，γ2（N\u002Fm?mm2）为（）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"2.25X10-2；",{"key":24,"text":149,"correct":22},"2.52X10—2；",{"key":28,"text":151,"correct":26},"2.73X10—2；",{"key":31,"text":153,"correct":22},"2.83X10-2,",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":28,"analysis":33},1023218,"电线覆冰有湿雪、雾淞、雨淞，比重从0.2~0.9。电线覆冰形状受风的影响，会呈现出千奇百怪的样子，一般迎风面较大，但是偏心使电线扭转，从而覆冰包严电线电线设计冰厚（W是将其折算为比重0.9的正圆筒。因此，电线覆冰单位荷载（kg\u002Fm）的计算， 要先算出内径为d（mm）,外径为d+26（mm）,1m冰筒的体积，公式为π\u002F4[(d+2b）2-d2]=π（b+d）b（cm3）,再乘以冰的比重0.9，即得单位冰荷重P2（g）。 同上，但在20mm冰区，γ2[N\u002F （m?mm2）]为（）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"5.25X10-2；",{"key":24,"text":161,"correct":22},"6.31X10-2；",{"key":28,"text":163,"correct":26},"7.04X10-2；",{"key":31,"text":165,"correct":22},"7.51X10-2。",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":28,"analysis":33},1023219,"在送电线上，无结冰或轻冰地区，其机械强度主要受最大设计风速控制’该风速取值主要根据沿线气象台资料及附近已有线路的运行经验，并计入以下规定确定。 110~330kV送电线路的重现期（）年。",[170,172,174,176],{"key":20,"text":171,"correct":22},"5；",{"key":24,"text":173,"correct":22},"10；",{"key":28,"text":175,"correct":26},"15；",{"key":31,"text":177,"correct":22},"20。",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":28,"analysis":33},1023220,"在送电线上，无结冰或轻冰地区，其机械强度主要受最大设计风速控制’该风速取值主要根据沿线气象台资料及附近已有线路的运行经验，并计入以下规定确定。 500kV送电线路的重现期（）。",[182,183,185,187],{"key":20,"text":173,"correct":22},{"key":24,"text":184,"correct":22},"20；",{"key":28,"text":186,"correct":26},"30；",{"key":31,"text":188,"correct":22},"40.",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":24,"analysis":33},1023221,"在送电线上，无结冰或轻冰地区，其机械强度主要受最大设计风速控制’该风速取值主要根据沿线气象台资料及附近已有线路的运行经验，并计入以下规定确定。 110~330kV\u002F500kV送电线路设计风速的髙度（m）应为（）。",[193,195,197,199],{"key":20,"text":194,"correct":22},"10\u002F15；",{"key":24,"text":196,"correct":26},"15\u002F20；",{"key":28,"text":198,"correct":22},"20\u002F30；",{"key":31,"text":200,"correct":22},"25\u002F40。",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":31,"analysis":33},1023222,"在送电线上，无结冰或轻冰地区，其机械强度主要受最大设计风速控制’该风速取值主要根据沿线气象台资料及附近已有线路的运行经验，并计入以下规定确定。 统计设计最大风速时，取年最大风速何种时距（）的平均值为样本。",[205,207,209,211],{"key":20,"text":206,"correct":22},"瞬时；",{"key":24,"text":208,"correct":22},"2分钟；",{"key":28,"text":210,"correct":22},"5分钟；",{"key":31,"text":212,"correct":26},"10分钟。",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":24,"analysis":33},1023223,"电线上风荷载昨计算是以风速V （m\u002Fs）的基本风压=W0=V2\u002F16（kg?f\u002Fm）=V2\u002F16 （N\u002Fm2）乘以风速在档距中不均匀的折减系数α，电线风载体型系数C和受风面积（m2）。 LGJ-300\u002F50,d=24.26mm,A=348.36mm2,V=35m\u002Fs,其γ4[N\u002F（m?mm2）]为（）。",[217,219,221,223],{"key":20,"text":218,"correct":22},"3.32X1O-2；",{"key":24,"text":220,"correct":26},"4.02X10-2；",{"key":28,"text":222,"correct":22},"4.35X10-2；",{"key":31,"text":224,"correct":22},"4.53X10-2。",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":24,"analysis":33},1023224,"计算单回单导线送电线路的正序电抗（Ω\u002Fkm）公式是（）。",[229,230,231,232],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":24,"analysis":33},1023225,"计算单回送电线路正多边形n分裂导线的正序电抗（Ω\u002Fkm）公式是（）。",[237,238,239,240],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":20,"analysis":33},1023226,"海拔1OOOm以下的110kV送电线路，在雷电过电压\u002F操作过电压\u002F工作电压的风偏条件下，带电部分对杆塔的最小间隙（m）为（）。",[245,247,249,251],{"key":20,"text":246,"correct":26},"1.0\u002F0.7\u002F0.25；",{"key":24,"text":248,"correct":22},"1.1\u002F0.8\u002F0.3；",{"key":28,"text":250,"correct":22},"1.2\u002F0.9\u002F0.35；",{"key":31,"text":252,"correct":22},"1.3\u002F1.0\u002F0.4。",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":24,"analysis":33},1023227,"海拔500~1OOOm的500kV线路，在雷电过电压\u002F操作过电压\u002F工作电压的风偏条件下，带电部分对杆塔的最小间隙（m）为（）。",[257,259,261,263],{"key":20,"text":258,"correct":22},"3.2\u002F2.6\u002F1.2；",{"key":24,"text":260,"correct":26},"3.3\u002F2.7\u002F1.3；",{"key":28,"text":262,"correct":22},"3.4\u002F2.8\u002F1.4；",{"key":31,"text":264,"correct":22},"3.5\u002F2.9\u002F1.5.",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":24,"analysis":33},1023228,"在海拔髙度超过1OOOm地区，操作过电压及工作电压的间隙，当海拔高度从1OOOm算起每增加100m，间隙增加（）。",[269,271,273,275],{"key":20,"text":270,"correct":22},"0.5%；",{"key":24,"text":272,"correct":26},"1%；",{"key":28,"text":274,"correct":22},"1.5%；",{"key":31,"text":276,"correct":22},"2%。",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":24,"analysis":33},1023229,"为方便带电作业，在气温15℃,风速10m\u002Fs的风偏条件下，在操作人员要停留工作部位，考虑30~50cm人体活动范围后，500kV线路带电部分对接地部分的间隙（m）不小于（）。",[281,283,285,287],{"key":20,"text":282,"correct":22},"3.0；",{"key":24,"text":284,"correct":26},"3.25",{"key":28,"text":286,"correct":22},"3.4；",{"key":31,"text":288,"correct":22},"3.6。",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":24,"analysis":33},1023230,"重冰区导线的排列方式应采用（）。",[293,295,297,299],{"key":20,"text":294,"correct":22},"三角排列；",{"key":24,"text":296,"correct":26},"水平排列；",{"key":28,"text":298,"correct":22},"垂直排列；",{"key":31,"text":300,"correct":22},"均可，但加大线距。",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":28,"analysis":33},1023231,"按防雷要求，500kV铁塔线路，地线对边导线的保护角宜采用（）。",[305,307,309,311],{"key":20,"text":306,"correct":22},"0°~5°；",{"key":24,"text":308,"correct":22},"5°~10°；",{"key":28,"text":310,"correct":26},"10°~15°；",{"key":31,"text":312,"correct":22},"15°~20°。",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":28,"analysis":33},1023232,"按防雷要求，220kV双地线铁塔线路，地线对边导线的保护角宜用（）。",[317,319,321,323],{"key":20,"text":318,"correct":22},"10°左右；",{"key":24,"text":320,"correct":22},"15°左右；",{"key":28,"text":322,"correct":26},"20°左右；",{"key":31,"text":324,"correct":22},"25°左右。",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":31,"analysis":33},1023233,"按防雷要求，110kV山区单地线送电线路,地线对边导线的保护角宜采用（）。",[329,330,331,332],{"key":20,"text":318,"correct":22},{"key":24,"text":320,"correct":22},{"key":28,"text":322,"correct":22},{"key":31,"text":324,"correct":26},{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":28,"analysis":33},1023234,"为防止覆冰或脱冰时，导地线间发生闪络，220kV线路在15mm冰区，地线对边导线的水平偏移应不小于（）。",[337,339,341,343],{"key":20,"text":338,"correct":22},"0.5m；",{"key":24,"text":340,"correct":22},"1.0m；",{"key":28,"text":342,"correct":26},"1.5m；",{"key":31,"text":344,"correct":22},"2.Om。",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":24,"analysis":33},1023235,"为防止覆冰或脱冰时，导地线间发生闪络，500kV线路在1Omm冰区，地线对边导线的水平偏移应不小于（）。",[349,350,352,354],{"key":20,"text":342,"correct":22},{"key":24,"text":351,"correct":26},"1.75m；",{"key":28,"text":353,"correct":22},"2.Om；",{"key":31,"text":355,"correct":22},"2.25m。",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":28,"analysis":33},1023236,"为防止覆冰或脱冰时，导地线间发生闪络，窗线路在15画冰区，地线对边导线的水平偏移应不小于（）。",[360,361,362,364],{"key":20,"text":340,"correct":22},{"key":24,"text":342,"correct":22},{"key":28,"text":363,"correct":26},"2.0m；",{"key":31,"text":365,"correct":22},"2.5m。",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":24,"analysis":33},1023237,"某水平排列单回路双地线耐张铁塔，导地线挂线点间垂直距离为2m，按防雷要求两地线间的水平距离不得大于（）。",[370,372,374,376],{"key":20,"text":371,"correct":22},"8m；",{"key":24,"text":373,"correct":26},"10m；",{"key":28,"text":375,"correct":22},"12m；",{"key":31,"text":377,"correct":22},"14m。",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":28,"analysis":33},1023238,"导线排列方式改变时，导线在档距中间最小距离应满足最小净空距离的规定，如220kV线路应大于（）。",[382,384,386,388],{"key":20,"text":383,"correct":22},"3~3.5m；",{"key":24,"text":385,"correct":22},"3.5~4m；",{"key":28,"text":387,"correct":26},"4~4.5m；",{"key":31,"text":389,"correct":22},"4.5~5m?",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":20,"analysis":33},1023239,"钢绞线的弹性系数E,在计算中采用（）。",[394,396,398,400],{"key":20,"text":395,"correct":26},"181400MPa；",{"key":24,"text":397,"correct":22},"185000MPa；",{"key":28,"text":399,"correct":22},"187000MPa；",{"key":31,"text":401,"correct":22},"199000MPa。",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":24,"analysis":33},1023240,"钢绞线的线膨胀系数α（10 6\u002F℃）在计算中采用（）。",[406,408,410,412],{"key":20,"text":407,"correct":22},"10.5；",{"key":24,"text":409,"correct":26},"11.5；",{"key":28,"text":411,"correct":22},"12.5；",{"key":31,"text":413,"correct":22},"13.5。",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":24,"analysis":33},1023241,"钢绞线的公称抗拉强度分别为1175, 1270，1370,1470N\u002Fmm2和1570N\u002Fmm2五个等级，架空地线一般选用（）。",[418,420,422,424],{"key":20,"text":419,"correct":22},"1175；",{"key":24,"text":421,"correct":26},"1270；",{"key":28,"text":423,"correct":22},"1370；",{"key":31,"text":425,"correct":22},"1570。",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":24,"analysis":33},1023242,"钢绞线的钢丝镀锌层级别分为A级特厚，B级厚，C级薄。送电线路一般选用（）。",[430,432,434,436],{"key":20,"text":431,"correct":22},"A级；",{"key":24,"text":433,"correct":26},"B级；",{"key":28,"text":435,"correct":22},"C级；",{"key":31,"text":437,"correct":22},"A级和C级。",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":28,"analysis":33},1023243,"电线以杆塔为支撑悬挂于空间，其弧线几何形状的精确表达式为（）。",[442,444,446,448],{"key":20,"text":443,"correct":22},"抛物线；",{"key":24,"text":445,"correct":22},"斜抛物线；",{"key":28,"text":447,"correct":26},"悬链线；",{"key":31,"text":449,"correct":22},"双曲线。",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":20,"analysis":33},1023244,"悬链线方程为： 可见悬链线方程含双曲线函数，计算复杂。在档距",[454,456,457,459],{"key":20,"text":455,"correct":26},"和高差均不大时，可取其级数展开的主要项，得到足够精度的近似公式，其方程为（）。",{"key":24,"text":443,"correct":22},{"key":28,"text":458,"correct":22},"双曲线；",{"key":31,"text":460,"correct":22},"闽弧线； D,椭圆弧线。",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":28,"analysis":33},1023245,"导线拉断力与孤垂最低点的导线最大使用张力的比为导线设计安全系数，其值应不小于（）。",[465,467,469,471],{"key":20,"text":466,"correct":22},"2；",{"key":24,"text":468,"correct":22},"2.25；",{"key":28,"text":470,"correct":26},"2.5；",{"key":31,"text":472,"correct":22},"3。",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":24,"analysis":33},1023246,"由于导线在悬挂点的张力大于导线最低点的张力，故导线在悬挂点的张力应予校验。导线悬挂点的安全系数应不小于（）。",[477,478,479,480],{"key":20,"text":466,"correct":22},{"key":24,"text":468,"correct":26},{"key":28,"text":470,"correct":22},{"key":31,"text":472,"correct":22},{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":24,"analysis":33},1023247,"在某些气象条件恶劣的地区，送电线路还应校验稀有风速和稀有覆冰的气象条件，此时，弧垂最低点的最大使用张力的安全系数应不小于（）。",[485,487,489,491],{"key":20,"text":486,"correct":22},"1.3；",{"key":24,"text":488,"correct":26},"1.66；",{"key":28,"text":490,"correct":22},"2.0；",{"key":31,"text":492,"correct":22},"2.25。",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":31,"analysis":33},1023248,"架空地线的设计安全系数应为（）。 A.2.75； B.3； C3.25； D.大于导线。",[497,498,499,500],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":24,"analysis":33},1023249,"悬式绝缘子的额定机械破坏负荷与其承受的最大使用负荷的比为绝缘子安全系数，其值应不小于（）。",[505,506,508,510],{"key":20,"text":470,"correct":22},{"key":24,"text":507,"correct":26},"2.7；",{"key":28,"text":509,"correct":22},"3；",{"key":31,"text":511,"correct":22},"3.5。",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":24,"analysis":33},1023250,"悬垂绝缘子串下悬挂连续的导线，导线的张力自身平衡。故绝缘子串只承受导线的垂直重量和风荷载，但当一档中导线断线时，杆塔将承受断线后的导线残余张力。为防止事故扩大，在断线情况下，悬垂绝缘子串的安全系数应不小于（）。",[516,518,520,521],{"key":20,"text":517,"correct":22},"1.5；",{"key":24,"text":519,"correct":26},"1.8；",{"key":28,"text":490,"correct":22},{"key":31,"text":522,"correct":22},"2.5。",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":31,"analysis":33},1023251,"悬式绝缘子瓷件的头部，承受着巨大的机械应力和电场强度，国内外的运行经验证明，若瓷件长期在过大的机械应力下运行，则易于劣化。故在年平均气温，无风的荷载条件下，绝缘子的安全系数应不小于（）。",[527,528,530,532],{"key":20,"text":509,"correct":22},{"key":24,"text":529,"correct":22},"3.5；",{"key":28,"text":531,"correct":22},"4；",{"key":31,"text":533,"correct":26},"4.5。",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":28,"analysis":33},1023252,"绝缘子串的连接金具，在最大使用负荷下的安全系数不小于（）。",[538,539,540,541],{"key":20,"text":466,"correct":22},{"key":24,"text":468,"correct":22},{"key":28,"text":470,"correct":26},{"key":31,"text":542,"correct":22},"2.75。",{"id":544,"libraryId":5,"type":15,"typeLabel":16,"stem":545,"options":546,"answer":20,"analysis":33},1023253,"绝缘子串的连接金具，在断线或断联的情况下，其安全系数应不小于（）。",[547,548,550,551],{"key":20,"text":517,"correct":26},{"key":24,"text":549,"correct":22},"1.75；",{"key":28,"text":490,"correct":22},{"key":31,"text":492,"correct":22},{"id":553,"libraryId":5,"type":15,"typeLabel":16,"stem":554,"options":555,"answer":20,"analysis":33},1023254,"当负荷特别大或重要的交叉跨越，常会使用双联或多联绝缘子并联的组串方式，这 时还应校验其中一联断裂后绝缘子的安全系数应不小于（）。",[556,557,558,559],{"key":20,"text":517,"correct":26},{"key":24,"text":549,"correct":22},{"key":28,"text":466,"correct":22},{"key":31,"text":560,"correct":22},"2.25.",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":28,"analysis":33},1023255,"绝缘子串的等值电路为每片绝缘子的自电容串联和片间金厲件对塔身（地）电容并联构成，致使电容电流在每片间分流，带电侧电压分布远髙于接地侧，在绝缘子串很长时，在带电端应安装均压环，以均衡带电端绝缘子串的过高电压，并防止电晕，规程要求（）电压等级及以上线路的绝缘子串应安装均压环。",[565,567,569,571],{"key":20,"text":566,"correct":22},"110kV；",{"key":24,"text":568,"correct":22},"220kV；",{"key":28,"text":570,"correct":26},"330kV；",{"key":31,"text":572,"correct":22},"500kV.",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":20,"analysis":33},1023256,"送电线路最常用的悬垂线夹为（）。",[577,579,581,583],{"key":20,"text":578,"correct":26},"固定线夹；",{"key":24,"text":580,"correct":22},"释放线夹；",{"key":28,"text":582,"correct":22},"滑动线夹；",{"key":31,"text":584,"correct":22},"潜轮线夹.",[586,589,592,595,598,601],{"id":15,"name":587,"category":7,"favorite":588},"领导干部任职前廉政法规知识测试题",92,{"id":590,"name":591,"category":7,"favorite":15},595,"建筑结构与设备",{"id":593,"name":594,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":596,"name":597,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":599,"name":600,"category":7,"favorite":8},534,"BIM工程师",{"id":602,"name":600,"category":7,"favorite":8},535]