[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-3":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":598},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,3,50,2670,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,246,258,270,282,292,304,314,326,338,350,358,370,380,390,402,414,426,438,450,458,468,478,490,502,514,526,538,550,562,574,586],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1021850,1,"单选题","380V低压短路电流计算中，所采用的计算曲线（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","只适用于铅芯电缆；",false,{"key":24,"text":25,"correct":26},"B","各种电缆均可适用；",true,{"key":28,"text":29,"correct":22},"C","适用于油浸低绝缘电缆；",{"key":31,"text":32,"correct":22},"D","适用于PVC电缆。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1021851,"网络化简和归并是短路电流计算的必须步骤，图5-2变化后的x'1、x'2、x'3值为（）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"x'1=0.5、x'2—0-33、x'3=1；",{"key":24,"text":41,"correct":26},"x'1=0.33、x'2=0.5,x'3=1；",{"key":28,"text":43,"correct":22},"x'1=0.6,x'2=0.5,x’3=0.33；",{"key":31,"text":45,"correct":22},"x'1=0.44,x’2=0.6,x'3=0.5。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},1021852,"短路电流计算中，下列假设条件错误的是（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"三相系统对称运行；",{"key":24,"text":53,"correct":22},"各年源的电动势相位相同；",{"key":28,"text":55,"correct":22},"各元件的磁路不饱和；",{"key":31,"text":57,"correct":26},"同步电机不设自动励磁装置",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},1021853,"导体和电器的动、热稳定以及电器的开断电流，按（）验算。",[62,64,66,68],{"key":20,"text":63,"correct":22},"三相短路；",{"key":24,"text":65,"correct":22},"两相短路；",{"key":28,"text":67,"correct":22},"单相短路；",{"key":31,"text":69,"correct":26},"所有短路中最严重的情况。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},1021854,"短路电流计算中，电路元件的参数采用（）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"基准值；",{"key":24,"text":77,"correct":22},"额定值；",{"key":28,"text":79,"correct":26},"标么值；",{"key":31,"text":81,"correct":22},"有名值。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":28,"analysis":33},1021855,"220kV系统的基准电压为（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"220kV；",{"key":24,"text":89,"correct":22},"242kV5",{"key":28,"text":91,"correct":26},"230kV;",{"key":31,"text":93,"correct":22},"200kV。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},1021856,"电路元件的标么值为（）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"有名值与基准值之比；",{"key":24,"text":101,"correct":22},"有名值与额定值之比；",{"key":28,"text":103,"correct":22},"基准值与有名值之比；",{"key":31,"text":105,"correct":22},"额定值与有名值之比。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},1021857,"若已知系统简图如图5-8所示，图中正序电抗：x1Σ=0.055，负序电抗x2Σ=0.0565,零序电抗：x0Σ=0.0424,Sj=1OOOMVA。 两相短路正序电流有名值为（）。",[110,112,114,116],{"key":20,"text":111,"correct":26},"9.867kA；",{"key":24,"text":113,"correct":22},"9.877kA；",{"key":28,"text":115,"correct":22},"9.887kA；",{"key":31,"text":117,"correct":22},"9.879kA。",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},1021858,"某500kV变电所，所址海拔2100m， 500kV出线本期2回，最终6回；主变压器本期1组750MV A，最终2组，220kV出线本期8回，最终120。 该变电所500kV接线既可采用一个半断路器接线，也可采用双母线四分段接线，则这两种接线的造价等价进出线回路数是（）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"7回；",{"key":24,"text":125,"correct":26},"8回；",{"key":28,"text":127,"correct":22},"9回；",{"key":31,"text":129,"correct":22},"10回。",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":28,"analysis":33},1021859,"某500kV变电所，所址海拔2100m， 500kV出线本期2回，最终6回；主变压器本期1组750MV A，最终2组，220kV出线本期8回，最终120。 该变电所220kV最终最合理的接线应为（）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"一个半断路器接线；",{"key":24,"text":137,"correct":22},"双母线接线；",{"key":28,"text":139,"correct":26},"双母线单分段接线；",{"key":31,"text":141,"correct":22},"双母线双分段接线。",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},1021860,"某发电厂新建2台600MW机组，以发电机一变压器组单元接线接入厂内220kV升压站，220kV送出线路4回。 对本电厂发电机励磁系统的选择，以下说法错误的是（）。",[146,148,150,152],{"key":20,"text":147,"correct":26},"如选用机端自并励，强励倍数一般应不大于2；",{"key":24,"text":149,"correct":22},"如选用旋转励磁，应東用无刷励磁；",{"key":28,"text":151,"correct":22},"励磁系统应能承受发电机出口短路而不应产生有害变形；",{"key":31,"text":153,"correct":22},"当选用机端自并励时，应综合考虑不同生产厂家的汽轮发电机组及电力系统稳定性的要求。",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},1021861,"某发电厂新建2台600MW机组，以发电机一变压器组单元接线接入厂内220kV升压站，220kV送出线路4回。 220kV电气主接线为双母线单分段，在选择22OkV断路器时，不需要求的项目是（）.",[158,160,162,164],{"key":20,"text":159,"correct":22},"近区故障开断能力；",{"key":24,"text":161,"correct":26},"并联开断能力；",{"key":28,"text":163,"correct":22},"失步开断能力；",{"key":31,"text":165,"correct":22},"电容性电流的开断能力。",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":28,"analysis":33},1021862,"某220kV变电所建于平原地区，污秽等级为III级，220kV采用双母线接线，主变压器的变比为220\u002F115±8Xl.25%\u002F10.5kV,接线组别为YNynOd11。 通过计算，确定变电所内220kV电压等级悬垂绝缘子串的片数为（），悬式绝缘子采用XWP—100,爬距为450mm,其爬距有效系数为0.95。",[170,172,174,176],{"key":20,"text":171,"correct":22},"14片；",{"key":24,"text":173,"correct":22},"15片；",{"key":28,"text":175,"correct":26},"16片；",{"key":31,"text":177,"correct":22},"17片。",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":28,"analysis":33},1021863,"某220kV变电所建于平原地区，污秽等级为III级，220kV采用双母线接线，主变压器的变比为220\u002F115±8Xl.25%\u002F10.5kV,接线组别为YNynOd11。 1OkV均为电缆出线，测得电容电流为38 A，对该1OkV系统的中性点接地方式的说法，以下正确的是（）。",[182,184,186,188],{"key":20,"text":183,"correct":22},"由于主变压器1OkV侧为三角形接线，故选择不接地方式；",{"key":24,"text":185,"correct":22},"可采用消弧线明接地方式，正常情况下，长时间中性点位移电压均不超i±額定相电压的15%；",{"key":28,"text":187,"correct":26},"可采用专用接地变压器，经消孤线圏接地；",{"key":31,"text":189,"correct":22},"可采用高电阻接地。",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":24,"analysis":33},1021864,"某11OkV系统，断路器的全分闸时间为0.06s，主保护动作时间为0.09s，后备保护动作时间为1.94s。 经计算，短路电流热效应Qdt =1O1OkA2s,请选择断路器的热稳定电流为（）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"16kA；",{"key":24,"text":197,"correct":26},"25kA；",{"key":28,"text":199,"correct":22},"31.5kA；",{"key":31,"text":201,"correct":22},"85kA。",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":20,"analysis":33},1021865,"某11OkV系统，断路器的全分闸时间为0.06s，主保护动作时间为0.09s，后备保护动作时间为1.94s。 仍采用上述热效应，确定110kV铜管母线最小热稳定截面为（）（短路前导体温度为50℃）。",[206,208,210,212],{"key":20,"text":207,"correct":26},"175mm2；",{"key":24,"text":209,"correct":22},"185mm2；",{"key":28,"text":211,"correct":22},"330mm2；",{"key":31,"text":213,"correct":22},"365mm2.",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":28,"analysis":33},1021866,"某220kV变电所，所址海拔1900m,位于II级污移区。 如果选用的耐张绝缘子单片爬距450mm，11OkV耐张绝缘子串至少应为（）。",[218,220,222,224],{"key":20,"text":219,"correct":22},"7片；",{"key":24,"text":221,"correct":22},"8片；",{"key":28,"text":223,"correct":26},"9片；",{"key":31,"text":225,"correct":22},"10片，",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":31,"analysis":33},1021867,"某220kV变电所，所址海拔1900m,位于II级污移区。 对该变电所耐张绝缘子的选择，以下说法错误的是（）。",[230,232,234,236],{"key":20,"text":231,"correct":22},"应按額定电压和爬电比距选择；",{"key":24,"text":233,"correct":22},"应按内过电压倍数和绝缘子串的工频湿闪电压选择；",{"key":28,"text":235,"correct":22},"应按避雷器的操作过电压保护水平和绝缘子串正极性操作冲击50%放电电压选择；",{"key":31,"text":237,"correct":26},"应按雷电过电压选择。",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":24,"analysis":33},1021868,"某220kV变电所位于大城市中心，220kV为内桥接线，11OkV为双母线接线；220kV和11OkV均采用GIS设备，户内布置。 220kV断路器的额定失步开断电流及工频恢复电压分别为（）。",[242,243,244,245],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":31,"analysis":33},1021869,"某220kV变电所位于大城市中心，220kV为内桥接线，11OkV为双母线接线；220kV和11OkV均采用GIS设备，户内布置。 220kVGIS中应采用快速接地开关的是（）。",[250,252,254,256],{"key":20,"text":251,"correct":22},"变压器回路的变压器侧接地开关；",{"key":24,"text":253,"correct":22},"TV回路的母线侧接地开关；",{"key":28,"text":255,"correct":22},"TV回路的TV侧接地开关；",{"key":31,"text":257,"correct":26},"出线回路的出线倒接地开关。",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":31,"analysis":33},1021870,"某11OkV变电站，主变压器电压为110\u002F35\u002F10kV，容量为40MV A，无功；用并联电容器装置装设于1OkV侧，假定并联电容器补偿容量按主变容量的10%装设，分成两组，电网主谐波为5次及以上，3次谐波不超标，请分析（或计算）回答以下问题。 根据题中的假定条件，电容器组的单组容量为（ ）kvar；当选择容量为1OOkvar单台电容器组合成电容器组，则电容器组容量为（）kvar。",[262,264,266,268],{"key":20,"text":263,"correct":22},"1200，1500；",{"key":24,"text":265,"correct":22},"1800,2100;",{"key":28,"text":267,"correct":22},"1500，1800；",{"key":31,"text":269,"correct":26},"2000,2100。",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":24,"analysis":33},1021871,"某11OkV变电站，主变压器电压为110\u002F35\u002F10kV，容量为40MV",[274,276,278,280],{"key":20,"text":275,"correct":22},"无功；用并联电容器装置装设于1OkV侧，假定并联电容器补偿容量按主变容量的10%装设，分成两组，电网主谐波为5次及以上，3次谐波不超标，请分析（或计算）回答以下问题。",{"key":24,"text":277,"correct":26},"本站电容器组的电抗率选择应为（）。",{"key":28,"text":279,"correct":22},"1%； B5%； C12%；",{"key":31,"text":281,"correct":22},"13%.",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":20,"analysis":33},1021872,"某11OkV变电站，主变压器电压为110\u002F35\u002F10kV，容量为40MV A，无功；用并联电容器装置装设于1OkV侧，假定并联电容器补偿容量按主变容量的10%装设，分成两组，电网主谐波为5次及以上，3次谐波不超标，请分析（或计算）回答以下问题。 单组电容器回路的工作电流为（）。",[286,288,290],{"key":20,"text":287,"correct":26},"156A； B135A；",{"key":24,"text":289,"correct":22},"189A；",{"key":28,"text":291,"correct":22},"223",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":28,"analysis":33},1021873,"某11OkV变电站，主变压器电压为110\u002F35\u002F10kV，容量为40MV A，无功；用并联电容器装置装设于1OkV侧，假定并联电容器补偿容量按主变容量的10%装设，分成两组，电网主谐波为5次及以上，3次谐波不超标，请分析（或计算）回答以下问题。 针对本题情况，选择适合本站电容器组的接线和保护方式（）。",[296,298,300,302],{"key":20,"text":297,"correct":22},"双星形接线采用中性点不平衡电流保护;",{"key":24,"text":299,"correct":22},"单星形接线采用相电压差动保；",{"key":28,"text":301,"correct":26},"单星形接线采用开口三角电压保护；",{"key":31,"text":303,"correct":22},"单星形接线采用桥式差电流保护。",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":33,"analysis":33},1021874,"某11OkV变电站，主变压器电压为110\u002F35\u002F10kV，容量为40MV A，无功；用并联电容器装置装设于1OkV侧，假定并联电容器补偿容量按主变容量的10%装设，分成两组，电网主谐波为5次及以上，3次谐波不超标，请分析（或计算）回答以下问题。 当单台电容器容量为1OOkvar,选择外熔断器作单台电容器内部故障保护时，熔断器的熔丝额定电流为（）。",[308,310,312],{"key":20,"text":309,"correct":22},"18A；",{"key":24,"text":311,"correct":22},"20A； C22A；",{"key":28,"text":313,"correct":22},"24",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":20,"analysis":33},1021875,"变电所的主变压器容量及台数选择。",[318,320,322,324],{"key":20,"text":319,"correct":26},"关于220~500kV变电所主变压器容量的叙述中正确的是（）。",{"key":24,"text":321,"correct":22},"主变压器容量选择应根据有关规定和上级审批的电力系统规划设计决定；",{"key":28,"text":323,"correct":22},"凡装有两台（组）及以上主变压器的变电所，其中一台（组）亊故停运后，其余主变压器的容量应保证该所全部负荷的60%，在计及过负荷能力后的允许时间内，保证用户的一级和二级负荷；",{"key":31,"text":325,"correct":22},"主变压器容量应根据地区供电条件、负荷性质、用电容量和运行方式等条件综合考虑确定。",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":24,"analysis":33},1021876,"变电所的主变压器容量及台数选择。 35~11OkV变电所中变压器的设置错误的是（）。",[330,332,334,336],{"key":20,"text":331,"correct":22},"在有一、二级负荷的变电所中，宜装设2台主变压器；",{"key":24,"text":333,"correct":26},"在有一、二级负荷的变电所中，一般应装设3台主变压器；",{"key":28,"text":335,"correct":22},"在有一、二级负荷的变电所中，当技术经济比较合理时，可装设2台以上主变压器；",{"key":31,"text":337,"correct":22},"如变电所可由中、低压侧电力网取得足够容量的备用电源时，可装设1台主变压器。",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":24,"analysis":33},1021877,"变电所的主变压器容量及台数选择。 关于主变压器的调压方式，下面所列各项正确的是（）。",[342,344,346,348],{"key":20,"text":343,"correct":22},"220kV及以上的降压变压器，一般不采用无励磁调压方式；",{"key":24,"text":345,"correct":26},"220kV及以上的降压变压器，仅在电网电压可能有较大变化的情况下，采用有载调压；",{"key":28,"text":347,"correct":22},"220kV及以上的降压变压器，一般釆用有载调压方式；",{"key":31,"text":349,"correct":22},"11OkV及以下的变压器，一般采用无励磁谓压方式。",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":31,"analysis":33},1021878,"消弧线圈容量选择及其他指标。 关于消弧线圏的过补偿容量计算公式，下面公式正确的是（）。",[354,355,356,357],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":31,"analysis":33},1021879,"消弧线圈容量选择及其他指标。 中性点经消弧线围接地的电网，在正常情况下，长时间中性点位移电压不应超过额定相电压的（）。",[362,364,366,368],{"key":20,"text":363,"correct":22},"5%；",{"key":24,"text":365,"correct":22},"8%,",{"key":28,"text":367,"correct":22},"10%；",{"key":31,"text":369,"correct":26},"15%。",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":28,"analysis":33},1021880,"消弧线圈容量选择及其他指标。 中性点经消弧线圏接地的发电机，在正常情况下，长时间中性点位移电压不应超过额定相电压的（）。",[374,375,377,379],{"key":20,"text":363,"correct":22},{"key":24,"text":376,"correct":22},"8%；",{"key":28,"text":378,"correct":26},"10%,",{"key":31,"text":369,"correct":22},{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":24,"analysis":33},1021881,"消弧线圈容量选择及其他指标。 中性点经消弧线圈接地的电网，在正常情况下，脱谐度一般不大于（）。",[384,385,386,388],{"key":20,"text":365,"correct":22},{"key":24,"text":367,"correct":26},{"key":28,"text":387,"correct":22},"15%；",{"key":31,"text":389,"correct":22},"20%。",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":31,"analysis":33},1021882,"消弧线圈容量选择及其他指标。 中性点经消弧线圏接地的发电机，在正常情况下，考虑到限制传递过电压等因素，脱谐度不宜超过（）。",[394,396,398,400],{"key":20,"text":395,"correct":22},"±8%；",{"key":24,"text":397,"correct":22},"±10%；",{"key":28,"text":399,"correct":22},"±15%；",{"key":31,"text":401,"correct":26},"±30%。",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":28,"analysis":33},1021883,"穿墙套管的选择。 穿墙套管按技术条件选择，不需要考虑的项目包括（）。",[406,408,410,412],{"key":20,"text":407,"correct":22},"电压；",{"key":24,"text":409,"correct":22},"电流；",{"key":28,"text":411,"correct":26},"正常机械荷载；",{"key":31,"text":413,"correct":22},"动稳定。",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":20,"analysis":33},1021884,"穿墙套管的选择。 装在屋内的穿墙套管的环境条件，需要校验的项目包括（）。",[418,420,422,424],{"key":20,"text":419,"correct":26},"环境温度；",{"key":24,"text":421,"correct":22},"最大风速；",{"key":28,"text":423,"correct":22},"日温差；",{"key":31,"text":425,"correct":22},"污秽。",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":31,"analysis":33},1021885,"穿墙套管的选择。 穿墙套管按短路动稳定要求ρ≤kρxu，其中ρxu是穿墙套管的抗弯破坏负荷（N）,为在短路时作用于穿墙套管的力（N）。系数A值正确的是（）。",[430,432,434,436],{"key":20,"text":431,"correct":22},"k=0.4；",{"key":24,"text":433,"correct":22},"k=0.5；",{"key":28,"text":435,"correct":22},"k=0.55；",{"key":31,"text":437,"correct":26},"k=0.6。",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":24,"analysis":33},1021886,"穿墙套管的选择。 在发电厂或变电所与6kV屋外母线桥连的穿墙套管，当有冰雪时，根据有关规定宜选（）。",[442,444,446,448],{"key":20,"text":443,"correct":22},"用6kV的屋外穿墻套管；",{"key":24,"text":445,"correct":26},"用1OkV的屋外穿墙套管；",{"key":28,"text":447,"correct":22},"用20kV的屋外穿墙套管；",{"key":31,"text":449,"correct":22},"用35kV的屋外穿墙套管。",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":28,"analysis":33},1021887,"穿墙套管的选择。 当穿墙套管装在户内，环境温度高于+40℃，但不超过+60℃时，穿墙套管的持续允许电流会降低，它的降低有一修正的计算公式，下面所列式子正确的是（）（θ是周围实际环境温度）。",[454,455,456,457],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":28,"analysis":33},1021888,"支柱绝缘子选择。 装在屋外的支柱绝缘子，不需要校验的环境条件包括（）。",[462,463,465,467],{"key":20,"text":419,"correct":22},{"key":24,"text":464,"correct":22},"日温差、最大风速；",{"key":28,"text":466,"correct":26},"相对湿度；",{"key":31,"text":425,"correct":22},{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":31,"analysis":33},1021889,"支柱绝缘子选择。 支柱绝缘子按短路动稳定要求ρ≤kρxu，其中为支柱绝缘子的抗弯破坏负荷（N），ρxu为在短路时作用于支柱绝缘子的力（N）,系数A值正确的为（）。",[472,474,476,477],{"key":20,"text":473,"correct":22},"k=O.45；",{"key":24,"text":475,"correct":22},"k=O.5；",{"key":28,"text":435,"correct":22},{"key":31,"text":437,"correct":26},{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":28,"analysis":33},1021890,"支柱绝缘子选择。 在发电厂或变电所的屋外10kV母线桥用的支柱绝缘子，当有冰雷时，应选用（）更合理。",[482,484,486,488],{"key":20,"text":483,"correct":22},"6kV的屋外支柱绝缘子；",{"key":24,"text":485,"correct":22},"10kV的屋外支柱绝缘子；",{"key":28,"text":487,"correct":26},"20kV的屋外支柱绝缘子；",{"key":31,"text":489,"correct":22},"35kV的屋外支柱絶缘子。",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":31,"analysis":33},1021891,"支柱绝缘子选择。 支柱绝缘子的安全系数，下面所列各数值正确的是（）。",[494,496,498,500],{"key":20,"text":495,"correct":22},"荷载长期作用时为1.2；",{"key":24,"text":497,"correct":22},"荷载短时作用时为1.45；",{"key":28,"text":499,"correct":22},"荷载长期作用时为2.0；",{"key":31,"text":501,"correct":26},"荷载短时作用时为1.67。",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":31,"analysis":33},1021892,"设备的额定电压与设备最高电压， 系统额定电压为3kV时，电气设备最高允许电压应为（）。",[506,508,510,512],{"key":20,"text":507,"correct":22},"3.15kV；",{"key":24,"text":509,"correct":22},"3.25kV,",{"key":28,"text":511,"correct":22},"3.3kV；",{"key":31,"text":513,"correct":26},"3.6kV。",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":31,"analysis":33},1021893,"设备的额定电压与设备最高电压， 系统额定电压为1OkV时，电气设备最高允许电压应为（ ）。",[518,520,522,524],{"key":20,"text":519,"correct":22},"10.5kV；",{"key":24,"text":521,"correct":22},"11kV；",{"key":28,"text":523,"correct":22},"11.5kV；",{"key":31,"text":525,"correct":26},"12kV。",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":31,"analysis":33},1021894,"设备的额定电压与设备最高电压， 系统额定电压为220kV，电气设备最髙允许电压应为（ ）。",[530,532,534,536],{"key":20,"text":531,"correct":22},"225kV；",{"key":24,"text":533,"correct":22},"230kV；",{"key":28,"text":535,"correct":22},"240kV；",{"key":31,"text":537,"correct":26},"252kV.",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":31,"analysis":33},1021895,"设备的额定电压与设备最高电压， 系统额定电压为330kV，电气设备最高允许电压应为（ ）。",[542,544,546,548],{"key":20,"text":543,"correct":22},"340kV；",{"key":24,"text":545,"correct":22},"345kV；",{"key":28,"text":547,"correct":22},"356kV；",{"key":31,"text":549,"correct":26},"362kV。",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":31,"analysis":33},1021896,"设备的额定电压与设备最高电压， 系统额定电压为500kV，电气设备最髙允许电压应为（ ）。",[554,556,558,560],{"key":20,"text":555,"correct":22},"520kV；",{"key":24,"text":557,"correct":22},"530kV；",{"key":28,"text":559,"correct":22},"540kV；",{"key":31,"text":561,"correct":26},"550kV,",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":20,"analysis":33},1021897,"选用电器额定电流不得低于所在回路各种可能运行方式下的持续工作电流，即IN≥Ig,不同回路的持续工作电流： 带出线电抗器的出线回路计算工作电流应选用下面所给的条件中的（）。",[566,568,570,572],{"key":20,"text":567,"correct":26},"电抗器的额定电流；",{"key":24,"text":569,"correct":22},"1.05倍的电抗器的额定电流；",{"key":28,"text":571,"correct":22},"1.07倍的电抗器的额定电流；",{"key":31,"text":573,"correct":22},"1.1倍的电抗器的额定电流。",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":24,"analysis":33},1021898,"选用电器额定电流不得低于所在回路各种可能运行方式下的持续工作电流，即IN≥Ig,不同回路的持续工作电流： 变压器回路计算工作电流应选择下面条件中的（）。",[578,580,582,584],{"key":20,"text":579,"correct":22},"变压器的额定电流丨",{"key":24,"text":581,"correct":26},"1.05倍变压器額定电流；",{"key":28,"text":583,"correct":22},"1.1倍变压器颏定电流；",{"key":31,"text":585,"correct":22},"1.2倍变压器额定电流。",{"id":587,"libraryId":5,"type":15,"typeLabel":16,"stem":588,"options":589,"answer":24,"analysis":33},1021899,"选用电器额定电流不得低于所在回路各种可能运行方式下的持续工作电流，即IN≥Ig,不同回路的持续工作电流： 发电机回路计算工作电流应选用下面所给的条件中的（）。",[590,592,594,596],{"key":20,"text":591,"correct":22},"发电机额定电流；",{"key":24,"text":593,"correct":26},"1.05倍发电机額定电流f",{"key":28,"text":595,"correct":22},"1.1倍发电机额定电流；",{"key":31,"text":597,"correct":22},"1.2倍发电机額定电流。",[599,602,605,608,611,614],{"id":15,"name":600,"category":7,"favorite":601},"领导干部任职前廉政法规知识测试题",92,{"id":603,"name":604,"category":7,"favorite":15},595,"建筑结构与设备",{"id":606,"name":607,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":609,"name":610,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":612,"name":613,"category":7,"favorite":8},534,"BIM工程师",{"id":615,"name":613,"category":7,"favorite":8},535]