[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-29":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":595},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,29,50,2670,[13,34,46,58,70,82,90,102,114,126,138,150,162,174,183,195,207,217,229,241,253,265,277,287,295,306,318,330,342,354,366,378,389,401,409,417,429,441,453,465,477,488,500,511,523,535,547,559,571,583],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1023156,1,"单选题","电线是由多股单线绞制而成，受力后会产生塑性伸长和蠕变（简称初伸长），它与拉力的大小和时间有关，在运行中，这种初伸长逐渐放出，使弧垂增大，减小了安全距离，所以在架线施工中，需预先补偿，即适当减小施工弧垂，使初伸长放出后达到设计预期弧垂。 常用的初伸长补偿方法有（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","将电线预拉；",false,{"key":24,"text":25,"correct":26},"B","较实际施工温度降低一定温度数傳At查施工孤垂；",true,{"key":28,"text":29,"correct":22},"C","加大施工张力；",{"key":31,"text":32,"correct":22},"D","降低施工张力。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},1023157,"电线是由多股单线绞制而成，受力后会产生塑性伸长和蠕变（简称初伸长），它与拉力的大小和时间有关，在运行中，这种初伸长逐渐放出，使弧垂增大，减小了安全距离，所以在架线施工中，需预先补偿，即适当减小施工弧垂，使初伸长放出后达到设计预期弧垂。 钢芯铝绞线视铝钢比不同，初伸长约3\u002F万~4\u002F万，若采用降温法补偿，其值为（）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"5~20℃；",{"key":24,"text":41,"correct":22},"10~15℃；",{"key":28,"text":43,"correct":26},"15~25℃；",{"key":31,"text":45,"correct":22},"25~35℃。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1023158,"电线是由多股单线绞制而成，受力后会产生塑性伸长和蠕变（简称初伸长），它与拉力的大小和时间有关，在运行中，这种初伸长逐渐放出，使弧垂增大，减小了安全距离，所以在架线施工中，需预先补偿，即适当减小施工弧垂，使初伸长放出后达到设计预期弧垂。 镀锌钢绞线的初伸长约1\u002F万，若用降温法补偿，其值为（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"5℃；",{"key":24,"text":53,"correct":26},"1O℃；",{"key":28,"text":55,"correct":22},"15℃；",{"key":31,"text":57,"correct":22},"20℃。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},1023159,"架空地线是逐塔接地的，由于雷电，污秽及绝缘子故障等导致线路接地短路时（特别是在变电所附近接地短路），地线中将短时间流过很大短路电流，使地线温度骤然猛烈升高而丧失机械强度。因此，需要验算地线短路时的热稳定、计算时间及相应的短路电流值根据系统情况决定，地线的允许温度为： 钢绞线（）℃。",[62,64,66,68],{"key":20,"text":63,"correct":22},"350；",{"key":24,"text":65,"correct":26},"400；",{"key":28,"text":67,"correct":22},"450；",{"key":31,"text":69,"correct":22},"500。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},1023160,"架空地线是逐塔接地的，由于雷电，污秽及绝缘子故障等导致线路接地短路时（特别是在变电所附近接地短路），地线中将短时间流过很大短路电流，使地线温度骤然猛烈升高而丧失机械强度。因此，需要验算地线短路时的热稳定、计算时间及相应的短路电流值根据系统情况决定，地线的允许温度为： 钢芯铝绞线和钢芯铝合金绞线（）℃。",[74,76,78,80],{"key":20,"text":75,"correct":26},"200；",{"key":24,"text":77,"correct":22},"250；",{"key":28,"text":79,"correct":22},"300；",{"key":31,"text":81,"correct":22},"350。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":28,"analysis":33},1023161,"架空地线是逐塔接地的，由于雷电，污秽及绝缘子故瘅等导致线路接地短路时（特别是在变电所附近接地短路），地线中将短时间流过很大短路电流，使地线温度骤然猛烈升高而丧失机械强度。因此，需要验算地线短路时的热稳定、计算时间及相应的短路电流值根据系统情况决定，地线的允许温度为： 铝包钢绞线和钢芯铝包钢绞线C ）℃。",[86,87,88,89],{"key":20,"text":75,"correct":22},{"key":24,"text":77,"correct":22},{"key":28,"text":79,"correct":26},{"key":31,"text":81,"correct":22},{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":28,"analysis":33},1023162,"单导线的单回路或双回路直线杆塔，导线的断线条件为无冰、无风，断任意一根导线。由于导线断线后悬垂绝缘子串偏移，使残余的断线张力减少。该张力与断线气象条件，断线后剩余档的档数、档距、髙差、绝缘子串长，杆塔刚度及地线支持力等多种因素有关。因断线时导线剧烈振荡，还将产生冲击荷载，因此影响因索众多，计算复杂而不准确。故规程规定断线张力取最大使用张力的一个百分值，其值为。 导线LGJ—120\u002F20至LGJ—185\u002F45的拉线杆塔\u002F自立铁塔为（）。",[94,96,98,100],{"key":20,"text":95,"correct":22},"25\u002F30；",{"key":24,"text":97,"correct":22},"30\u002F35；",{"key":28,"text":99,"correct":26},"35\u002F40；",{"key":31,"text":101,"correct":22},"40\u002F45.",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":24,"analysis":33},1023163,"单导线的单回路或双回路直线杆塔，导线的断线条件为无冰、无风，断任意一根导线。由于导线断线后悬垂绝缘子串偏移，使残余的断线张力减少。该张力与断线气象条件，断线后剩余档的档数、档距、髙差、绝缘子串长，杆塔刚度及地线支持力等多种因素有关。因断线时导线剧烈振荡，还将产生冲击荷载，因此影响因索众多，计算复杂而不准确。故规程规定断线张力取最大使用张力的一个百分值，其值为。",[106,108,110,112],{"key":20,"text":107,"correct":22},"导线LGJ—240\u002F20及以上的拉线杆塔\u002F自立塔为（）。",{"key":24,"text":109,"correct":26},"35\u002F45,",{"key":28,"text":111,"correct":22},"40\u002F50； C45\u002F55；",{"key":31,"text":113,"correct":22},"50\u002F60。",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":28,"analysis":33},1023164,"单回路或双回路分裂导线的直线杆塔不考虑一相全部子导线同时断线，而其中一根子导线断线时，剩余的子导线将通过间隔棒及悬垂金具分担断线张力，杆塔上只承受较小的不平衡张力。故规程规定，分裂导线直线杆塔的断线条件为无冰，无风，任一相有纵向不平衡张力，取值为导线最大使用张力的百分数，其值为：",[118,120,122,124],{"key":20,"text":119,"correct":22},"二分裂导线平地\u002F山地，分别取一根子导线的（）。",{"key":24,"text":121,"correct":22},"30\u002F40；",{"key":28,"text":123,"correct":26},"35\u002F45； C40\u002F50；",{"key":31,"text":125,"correct":22},"45\u002F55。",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":24,"analysis":33},1023165,"单回路或双回路分裂导线的直线杆塔不考虑一相全部子导线同时断线，而其中一根子导线断线时，剩余的子导线将通过间隔棒及悬垂金具分担断线张力，杆塔上只承受较小的不平衡张力。故规程规定，分裂导线直线杆塔的断线条件为无冰，无风，任一相有纵向不平衡张力，取值为导线最大使用张力的百分数，其值为： 三分裂及以上导线，平地\u002F丘陵\u002F山地分别取一相导电的（）（且均应大于20kN）。",[130,132,134,136],{"key":20,"text":131,"correct":22},"10\u002F15\u002F20；",{"key":24,"text":133,"correct":26},"15\u002F20\u002F25；",{"key":28,"text":135,"correct":22},"20\u002F25\u002F30；",{"key":31,"text":137,"correct":22},"25\u002F30\u002F35。",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":24,"analysis":33},1023166,"耐张转角杆塔，除承受导地线冰、风荷载，断线张力外，还同时承受导地线张力产生的角度合力及纵向张力差。由于承力杆塔两侧代表档距不同’故两侧张力不等。正常情况下，横担应位于导地线的角平分线上。故α1=α2=1\u002F2α（α为线路转角）。设有某转角60°的铁塔，4分裂导线，子导线张力T1=3600kg?f，T2=3000kg?f。 每相导线的角度合力为（）kg?f。",[142,144,146,148],{"key":20,"text":143,"correct":22},"12000；",{"key":24,"text":145,"correct":26},"13200；",{"key":28,"text":147,"correct":22},"14100；",{"key":31,"text":149,"correct":22},"15000。",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":28,"analysis":33},1023167,"耐张转角杆塔，除承受导地线冰、风荷载，断线张力外，还同时承受导地线张力产生的角度合力及纵向张力差。由于承力杆塔两侧代表档距不同’故两侧张力不等。正常情况下，横担应位于导地线的角平分线上。故α1=α2=1\u002F2α（α为线路转角）。设有某转角60°的铁塔，4分裂导线，子导线张力T1=3600kg?f，T2=3000kg?f。 每相导线的张力差为（）kg ?f。",[154,156,158,160],{"key":20,"text":155,"correct":22},"1500,",{"key":24,"text":157,"correct":22},"1810；",{"key":28,"text":159,"correct":26},"2080；",{"key":31,"text":161,"correct":22},"2200?",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":24,"analysis":33},1023168,"由于三相导线在空间位置上对地、对杆塔和导地线自身间位置的不等同，故每相的阻抗和导纳是不相等的，从而引起负序和零序电流，为使阻抗和导纳平衡，长线路要采用换位，使每相导线在左、中、右或上、中、下位置的长度相等。 规程要求在中性点直接接地的电网中，长度超过（）要求换位。",[166,168,170,172],{"key":20,"text":167,"correct":22},"50km；",{"key":24,"text":169,"correct":26},"100km；",{"key":28,"text":171,"correct":22},"150km；",{"key":31,"text":173,"correct":22},"200km。",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":31,"analysis":33},1023169,"由于三相导线在空间位置上对地、对杆塔和导地线自身间位置的不等同，故每相的阻抗和导纳是不相等的，从而引起负序和零序电流，为使阻抗和导纳平衡，长线路要采用换位，使每相导线在左、中、右或上、中、下位置的长度相等。 规程要求每个换位循环长度不宜大于（）。",[178,179,180,181],{"key":20,"text":167,"correct":22},{"key":24,"text":169,"correct":22},{"key":28,"text":171,"correct":22},{"key":31,"text":182,"correct":26},"2OOkm。",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":20,"analysis":33},1023170,"由于三相导线在空间位置上对地、对杆塔和导地线自身间位置的不等同，故每相的阻抗和导纳是不相等的，从而引起负序和零序电流，为使阻抗和导纳平衡，长线路要采用换位，使每相导线在左、中、右或上、中、下位置的长度相等。 如一个变电所某级电压的每回出线虽小于100km,但总长大于200km，还可采取（）措施平衡不对称电流。",[187,189,191,193],{"key":20,"text":188,"correct":26},"变换各回路的相序排列；",{"key":24,"text":190,"correct":22},"不需采取措施；",{"key":28,"text":192,"correct":22},"取消架空地线；",{"key":31,"text":194,"correct":22},"改用双回路铁塔。",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":24,"analysis":33},1023171,"送电线路应根据最髙气温情况或覆冰无风情况求得的最大弧垂，校验对地及被跨越物的距离。 110kV\u002F220kV线路对居民区的最小距离为（）。",[199,201,203,205],{"key":20,"text":200,"correct":22},"6.5m\u002F7m；",{"key":24,"text":202,"correct":26},"7m\u002F7.5m；",{"key":28,"text":204,"correct":22},"7.5m\u002F8m；",{"key":31,"text":206,"correct":22},"8.5m\u002F9m。",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":20,"analysis":33},1023172,"送电线路应根据最髙气温情况或覆冰无风情况求得的最大弧垂，校验对地及被跨越物的距离。 110kV\u002F220kV线路对非居民区的最小距离为（），",[211,213,214,215],{"key":20,"text":212,"correct":26},"6m\u002F6.5m?",{"key":24,"text":200,"correct":22},{"key":28,"text":202,"correct":22},{"key":31,"text":216,"correct":22},"7.5m\u002F8m。",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":28,"analysis":33},1023173,"送电线应根据最大设计风速情况或覆冰有风情况求得的导线最大风偏，校验对山坡、峭壁、岩石的最小净空距离。 110kV\u002F220kV线路对步行可以达到的山坡的最小距离为（）。",[221,223,225,227],{"key":20,"text":222,"correct":22},"4m\u002F4.5m；",{"key":24,"text":224,"correct":22},"4.5m\u002F5m；",{"key":28,"text":226,"correct":26},"5m\u002F5.5m；",{"key":31,"text":228,"correct":22},"5.5m\u002F6m。",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":28,"analysis":33},1023174,"海拔不超过1OOOm地区的送电线路，通常可不验算电晕的导线最小外径为： 200kV线路是（）。",[233,235,237,239],{"key":20,"text":234,"correct":22},"17.5mm；",{"key":24,"text":236,"correct":22},"19mm；",{"key":28,"text":238,"correct":26},"21.6mm；",{"key":31,"text":240,"correct":22},"21mm。",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":31,"analysis":33},1023175,"海拔不超过1OOOm地区的送电线路，通常可不验算电晕的导线最小外径为： 330kV线路是（）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"29.14mm；",{"key":24,"text":248,"correct":22},"30.96mm；",{"key":28,"text":250,"correct":22},"2X19mm；",{"key":31,"text":252,"correct":26},"2X21.6mm。",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":31,"analysis":33},1023176,"海拔不超过1OOOm地区的送电线路，通常可不验算电晕的导线最小外径为： 500kV线路是（）。",[257,259,261,263],{"key":20,"text":258,"correct":22},"2X33.6mm；",{"key":24,"text":260,"correct":22},"3X23.94mm；",{"key":28,"text":262,"correct":22},"4X19mm；",{"key":31,"text":264,"correct":26},"4X21.6mm。",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":20,"analysis":33},1023177,"控制导线允许载流量的主要依据是导线的最高允许温度。 钢芯铝纹线和钢芯铝合金绞线可采用（）。",[269,271,273,275],{"key":20,"text":270,"correct":26},"70℃；",{"key":24,"text":272,"correct":22},"75℃；",{"key":28,"text":274,"correct":22},"80℃；",{"key":31,"text":276,"correct":22},"90℃。",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":28,"analysis":33},1023178,"控制导线允许载流量的主要依据是导线的最高允许温度。 钢芯铝包钢绞线（包括招包钢绞线）可采用（）。",[281,282,284,286],{"key":20,"text":270,"correct":22},{"key":24,"text":283,"correct":22},"75°；",{"key":28,"text":285,"correct":26},"80°C；",{"key":31,"text":276,"correct":22},{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":31,"analysis":33},1023179,"控制导线允许载流量的主要依据是导线的最高允许温度。 用于大跨越线段的钢芯铝绞线和钢芯铝合金线可采用（）。",[291,292,293,294],{"key":20,"text":270,"correct":22},{"key":24,"text":272,"correct":22},{"key":28,"text":274,"correct":22},{"key":31,"text":276,"correct":26},{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":28,"analysis":33},1023180,"控制导线允许载流量的主要依据是导线的最高允许温度。 用于大跨越线段的钢芯铝包钢绞线可采用（）。",[299,300,302,304],{"key":20,"text":274,"correct":22},{"key":24,"text":301,"correct":22},"90℃；",{"key":28,"text":303,"correct":26},"100℃；",{"key":31,"text":305,"correct":22},"125℃。",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":24,"analysis":33},1023181,"在海拔1000m以下的非污秽区，送电线路操作及雷电过电压要求悬垂绝缘子串的最少片数为： 110kV送电线路是（）。",[310,312,314,316],{"key":20,"text":311,"correct":22},"6片；",{"key":24,"text":313,"correct":26},"7片；",{"key":28,"text":315,"correct":22},"8片；",{"key":31,"text":317,"correct":22},"9片。",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":28,"analysis":33},1023183,"在海拔1000m以下的非污秽区，送电线路操作及雷电过电压要求悬垂绝缘子串的最少片数为：",[322,324,326,328],{"key":20,"text":323,"correct":22},"3300kV送电线路是（）。",{"key":24,"text":325,"correct":22},"15片；",{"key":28,"text":327,"correct":26},"16片；C17片；",{"key":31,"text":329,"correct":22},"18片。",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":31,"analysis":33},1023184,"在海拔1000m以下的非污秽区，送电线路操作及雷电过电压要求悬垂绝缘子串的最少片数为： 500kV送电线路是（）。",[334,336,338,340],{"key":20,"text":335,"correct":22},"22片；",{"key":24,"text":337,"correct":22},"23片；",{"key":28,"text":339,"correct":22},"24片；",{"key":31,"text":341,"correct":26},"25片。",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":28,"analysis":33},1023185,"海拔1000m以下非污秽区，送电线路悬垂绝缘子串的片数，一般按设计规程要求的最少片数选择，但应根据线路实际情况修正。 对全髙超过40m有地线的杆塔，其绝缘子串的片数应（）。",[346,348,350,352],{"key":20,"text":347,"correct":22},"不变；",{"key":24,"text":349,"correct":22},"増加一片；",{"key":28,"text":351,"correct":26},"每増高1Om加1片；",{"key":31,"text":353,"correct":22},"每増高20m加一片。",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":24,"analysis":33},1023186,"海拔1000m以下非污秽区，送电线路悬垂绝缘子串的片数，一般按设计规程要求的最少片数选择，但应根据线路实际情况修正。 海拔超过1000m的地区，海拔髙度每增髙100m，其绝缘子片数较1000m以下规定片数增加（）。",[358,360,362,364],{"key":20,"text":359,"correct":22},"0.5%；",{"key":24,"text":361,"correct":26},"1%；",{"key":28,"text":363,"correct":22},"1.5%,",{"key":31,"text":365,"correct":22},"2%。",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":20,"analysis":33},1023187,"海拔1000m以下非污秽区，送电线路悬垂绝缘子串的片数，一般按设计规程要求的最少片数选择，但应根据线路实际情况修正。 送电线路绝缘应依照审定的污秽分区图进行防污设计，其选择绝缘子片数的原则是：（）。",[370,372,374,376],{"key":20,"text":371,"correct":26},"线路爬电比距要求；",{"key":24,"text":373,"correct":22},"绝缘子串污耐压；",{"key":28,"text":375,"correct":22},"污秽物的导电率及吸湿性；",{"key":31,"text":377,"correct":22},"离污秽源的距离。",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":31,"analysis":33},1023188,"海拔1000m以下非污秽区，送电线路悬垂绝缘子串的片数，一般按设计规程要求的最少片数选择，但应根据线路实际情况修正。 耐张绝缘子串的片数应较悬垂绝缘子串（）。",[382,384,386,387],{"key":20,"text":383,"correct":22},"减少一片；",{"key":24,"text":385,"correct":22},"相同；",{"key":28,"text":349,"correct":22},{"key":31,"text":388,"correct":26},"根据电压等级增加1~2片。",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":28,"analysis":33},1023189,"某220kV线路，某段路径穿越工矿污秽区，据地网局审定的“污区分布图”，被划分为II级污移区，现拟选用XWP-70耐污型悬式绝缘子（高146cm泄漏距离400mm）请核算： 悬垂绝缘子串需要的片数（）。",[393,395,397,399],{"key":20,"text":394,"correct":22},"13；",{"key":24,"text":396,"correct":22},"14；",{"key":28,"text":398,"correct":26},"15；",{"key":31,"text":400,"correct":22},"16。",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":28,"analysis":33},1023190,"某220kV线路，某段路径穿越工矿污秽区，据地网局审定的“污区分布图”，被划分为II级污移区，现拟选用XWP-70耐污型悬式绝缘子（高146cm泄漏距离400mm）请核算：",[405,406,407,408],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":28,"analysis":33},1023191,"某220kV线路，某地段穿越海拔2200m的髙原地区，为了该段线路的绝缘配合及塔头设计，请核算： 该段线路若选用片高146mm的标准绝缘子，其悬垂绝缘子片的片数为（）。",[413,414,415,416],{"key":20,"text":394,"correct":22},{"key":24,"text":396,"correct":22},{"key":28,"text":398,"correct":26},{"key":31,"text":400,"correct":22},{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":31,"analysis":33},1023192,"某220kV线路，某地段穿越海拔2200m的髙原地区，为了该段线路的绝缘配合及塔头设计，请核算： 该段线路操作过电压的间隙值为（）m。",[421,423,425,427],{"key":20,"text":422,"correct":22},"1.45；",{"key":24,"text":424,"correct":22},"1.55；",{"key":28,"text":426,"correct":22},"1.65；",{"key":31,"text":428,"correct":26},"1.75.",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":28,"analysis":33},1023193,"某220kV线路，某地段穿越海拔2200m的髙原地区，为了该段线路的绝缘配合及塔头设计，请核算： 该段线路工作电压的间隙值为（）m。",[433,435,437,439],{"key":20,"text":434,"correct":22},"0.55；",{"key":24,"text":436,"correct":22},"0.58；",{"key":28,"text":438,"correct":26},"0.62；",{"key":31,"text":440,"correct":22},"O.65。",{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":31,"analysis":33},1023194,"某220kV线路，某地段穿越海拔2200m的髙原地区，为了该段线路的绝缘配合及塔头设计，请核算： 该段线路雷电过电压间隙值为（）M。",[445,447,449,451],{"key":20,"text":446,"correct":22},"1.9；",{"key":24,"text":448,"correct":22},"2.0,",{"key":28,"text":450,"correct":22},"2.1；",{"key":31,"text":452,"correct":26},"2.2。",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":28,"analysis":33},1023195,"送电线路导线布置，单回路多用水平排列，双回路则多用垂直排列，若某220kV线路直线铁塔，设计用于1Omm冰区，最大使用档距700m，其最大弧垂为36m，绝缘子串长2.5m。 若单回路铁塔导线水平排列，其线间距离应不小于（）。",[457,459,461,463],{"key":20,"text":458,"correct":22},"5m；",{"key":24,"text":460,"correct":22},"6m；",{"key":28,"text":462,"correct":26},"7m；",{"key":31,"text":464,"correct":22},"8m。",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":24,"analysis":33},1023196,"送电线路导线布置，单回路多用水平排列，双回路则多用垂直排列，若某220kV线路直线铁塔，设计用于1Omm冰区，最大使用档距700m，其最大弧垂为36m，绝缘子串长2.5m。 若设计双回路铁塔，导线垂直排列’其线间垂直距离不小于（）。",[469,471,473,475],{"key":20,"text":470,"correct":22},"4.5m；",{"key":24,"text":472,"correct":26},"5.5m；",{"key":28,"text":474,"correct":22},"6.5m；",{"key":31,"text":476,"correct":22},"7.5m。",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":28,"analysis":33},1023197,"送电线路导线布置，单回路多用水平排列，双回路则多用垂直排列，若某220kV线路直线铁塔，设计用于1Omm冰区，最大使用档距700m，其最大弧垂为36m，绝缘子串长2.5m。 如上双回路垂直排列，两回路间的水平线间距离应不小于（）。",[481,483,484,486],{"key":20,"text":482,"correct":22},"5.5ms",{"key":24,"text":474,"correct":22},{"key":28,"text":485,"correct":26},"7.4m；",{"key":31,"text":487,"correct":22},"8.5m。",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":24,"analysis":33},1023198,"送电线路导线布置，单回路多用水平排列，双回路则多用垂直排列，若某220kV线路直线铁塔，设计用于1Omm冰区，最大使用档距700m，其最大弧垂为36m，绝缘子串长2.5m。 上、下层相邻导线间的水平偏移应不小于（）。",[492,494,496,498],{"key":20,"text":493,"correct":22},"0.5m；",{"key":24,"text":495,"correct":26},"1m；",{"key":28,"text":497,"correct":22},"1.5m；",{"key":31,"text":499,"correct":22},"2m。",{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":31,"analysis":33},1023199,"为防止雷击档距中央的地线反击导线造成事故，导地线在15℃无风的气象条件下，在档距中央应保持足够距离S。 某110kV线路，档距700m，S应大于（）。",[504,506,507,509],{"key":20,"text":505,"correct":22},"6.4m；",{"key":24,"text":485,"correct":22},{"key":28,"text":508,"correct":22},"8.4m；",{"key":31,"text":510,"correct":26},"9.4m。",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":24,"analysis":33},1023200,"为防止雷击档距中央的地线反击导线造成事故，导地线在15℃无风的气象条件下，在档距中央应保持足够距离S。 某500kV线路，档距700m，S应大于（）。",[515,517,519,521],{"key":20,"text":516,"correct":22},"8.4；",{"key":24,"text":518,"correct":26},"9.4；",{"key":28,"text":520,"correct":22},"10.4；",{"key":31,"text":522,"correct":22},"11.4。",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":24,"analysis":33},1023201,"直线塔间隙圆图是校验在各种过电压的气象条件下，绝缘子串风偏后对杆塔构件的空气间隙应满足规程要求： 间隙圆图不应校验（）。",[527,529,531,533],{"key":20,"text":528,"correct":22},"最髙运行电压；",{"key":24,"text":530,"correct":26},"工頻过电压；",{"key":28,"text":532,"correct":22},"操作过电压；",{"key":31,"text":534,"correct":22},"大气过电压，",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":31,"analysis":33},1023202,"直线塔间隙圆图是校验在各种过电压的气象条件下，绝缘子串风偏后对杆塔构件的空气间隙应满足规程要求： 在计算悬垂绝缘子串风偏角时，不应考虑（）。",[539,541,543,545],{"key":20,"text":540,"correct":22},"悬垂绝缘子串的重量及风压；",{"key":24,"text":542,"correct":22},"用水平档距计算导线风压；",{"key":28,"text":544,"correct":22},"用垂直档距计算导线重量；",{"key":31,"text":546,"correct":26},"用地形高差计算张力的垂直分量。",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":31,"analysis":33},1023203,"承力塔间隙画图是校验在各种过电压的气象条件下，跳线风偏后对接地构件的空气间隙是否满足规程要求。若跳线弧垂取得过小，会对横担及金具串接地端的距离不够；取得过大，则风偏后会对塔身或跳线下面的构件（如杯型塔中线对平口或垂直排列时对下面的横担）距离不够。施工弧垂参照允许最小和允许最大弧垂间的中值选取。 跳线计算中有以下假定，不正确的是（）。",[551,553,555,557],{"key":20,"text":552,"correct":22},"计算中不考虑跳线刚度的影响；",{"key":24,"text":554,"correct":22},"跳线形状假定为悬链线；",{"key":28,"text":556,"correct":22},"计算中，不考虑跳线应力的影响；",{"key":31,"text":558,"correct":26},"跳线形状假定为闽弧形。",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":31,"analysis":33},1023204,"承力塔间隙画图是校验在各种过电压的气象条件下，跳线风偏后对接地构件的空气间隙是否满足规程要求。若跳线弧垂取得过小，会对横担及金具串接地端的距离不够；取得过大，则风偏后会对塔身或跳线下面的构件（如杯型塔中线对平口或垂直排列时对下面的横担）距离不够。施工弧垂参照允许最小和允许最大弧垂间的中值选取。 耐张绝缘子串的水平偏角计算不应计及（）。",[563,565,567,569],{"key":20,"text":564,"correct":22},"线路路径转角的一半；",{"key":24,"text":566,"correct":22},"导线风压造成的耐张绝缘子串水平偏角的増加；",{"key":28,"text":568,"correct":22},"绝缘子串风压造成的耐张绝缘子串水平偏角的增加；",{"key":31,"text":570,"correct":26},"导线摆动造成的耐张绝缘子串偏角。",{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":31,"analysis":33},1023205,"承力塔间隙画图是校验在各种过电压的气象条件下，跳线风偏后对接地构件的空气间隙是否满足规程要求。若跳线弧垂取得过小，会对横担及金具串接地端的距离不够；取得过大，则风偏后会对塔身或跳线下面的构件（如杯型塔中线对平口或垂直排列时对下面的横担）距离不够。施工弧垂参照允许最小和允许最大弧垂间的中值选取。 耐张绝缘子串倾斜角的计算中不应计及（）。",[575,577,579,581],{"key":20,"text":576,"correct":22},"耐张绝缘子串重量；",{"key":24,"text":578,"correct":22},"耐张串侧导线垂直档距的重量；",{"key":28,"text":580,"correct":22},"导线水平张力；",{"key":31,"text":582,"correct":26},"导线弧垂。",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":28,"analysis":33},1023206,"由于铝股线直径越小，强度越高，而铝线股数越多，强度损失系数越大，故铝绞线计算拉断力与股数和股径有关。 铝绞线LJ一95 （结构7\u002F4.16）σ0=160N\u002Fmm2，其抗拉强度为（）。",[587,589,591,593],{"key":20,"text":588,"correct":22},"13540N；",{"key":24,"text":590,"correct":22},"14000N；",{"key":28,"text":592,"correct":26},"14459N；",{"key":31,"text":594,"correct":22},"15100N。",[596,599,602,605,608,611],{"id":15,"name":597,"category":7,"favorite":598},"领导干部任职前廉政法规知识测试题",92,{"id":600,"name":601,"category":7,"favorite":15},595,"建筑结构与设备",{"id":603,"name":604,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":606,"name":607,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":609,"name":610,"category":7,"favorite":8},534,"BIM工程师",{"id":612,"name":610,"category":7,"favorite":8},535]