[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-28":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":609},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,28,50,2670,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,188,200,212,224,235,247,259,271,283,295,307,319,331,343,355,367,378,386,397,407,419,431,443,455,467,479,491,503,515,527,539,551,563,575,585,597],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1023105,1,"单选题","正常照明网络电压应为（）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","110V；",false,{"key":24,"text":25,"correct":22},"B","220V；",{"key":27,"text":28,"correct":22},"C","380V；",{"key":30,"text":31,"correct":32},"D","380V\u002F220V。",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},1023106,"照明灯具端电压的偏移，对视觉要求较髙的主控制室、单元控制室、集中控制室等的室内照明为（）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"100%；",{"key":24,"text":41,"correct":22},"105%；",{"key":27,"text":43,"correct":32},"97.5%,",{"key":30,"text":45,"correct":22},"90%.",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1023107,"供给气体放电灯的配电线路宜在线路或灯具内设置电容补偿，功率因数不应低于（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"0.85；",{"key":24,"text":53,"correct":32},"0.9；",{"key":27,"text":55,"correct":22},"O.95；",{"key":30,"text":57,"correct":22},"1.0。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},1023108,"由集中照明变压器供电的主厂房正常照明母线，应采用（）。",[62,64,66,68],{"key":20,"text":63,"correct":32},"单母线接线；",{"key":24,"text":65,"correct":22},"单母线单分段接线；",{"key":27,"text":67,"correct":22},"双母线接线；",{"key":30,"text":69,"correct":22},"双母成双分段接线。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":27,"analysis":33},1023109,"多灰尘与潮湿场所应装设外壳防护等级为（）的照明配电箱。",[74,76,78,80],{"key":20,"text":75,"correct":22},"IP20；",{"key":24,"text":77,"correct":22},"IP32；",{"key":27,"text":79,"correct":32},"IP54；",{"key":30,"text":81,"correct":22},"IP65。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},1023110,"某电厂扩建2X300MW国产亚临界燃煤机组，机组以发电机一变压器组单元接线接入220kV系统双母线，220kV配电装置采用双母线母联兼旁路母线接线方式’启动\u002F备用电源由老厂110kV母线引接。 生产综合楼中某办公室长10m，宽为6m,吊顶髙度2.6m，采用嵌入格荧光灯具（2X40W，舰量为2X2200lm,利用系数为0.7），共均匀安装12套灯具，灯具排数为4排，距地0.8m处的平均照度为（）lx。",[86,88,90,92],{"key":20,"text":87,"correct":32},"430.8；",{"key":24,"text":89,"correct":22},"215.4；",{"key":27,"text":91,"correct":22},"473.8；",{"key":30,"text":93,"correct":22},"560。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},1023111,"某电厂扩建2X300MW国产亚临界燃煤机组，机组以发电机一变压器组单元接线接入220kV系统双母线，220kV配电装置采用双母线母联兼旁路母线接线方式’启动\u002F备用电源由老厂110kV母线引接。 汽机房安装有一个深照型灯具，安装高度距地面10.8m，该灯具投射至被照点方向的光强为1000cd，被照点距地0.8m,光线与被照面法线的夹角为60°，该灯具在该点水平工作面上的照度为（）lx。",[98,100,102,104],{"key":20,"text":99,"correct":22},"2.1；",{"key":24,"text":101,"correct":32},"2.5；",{"key":27,"text":103,"correct":22},"2.7；",{"key":30,"text":105,"correct":22},"2.。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},1023112,"某电厂扩建2X300MW国产亚临界燃煤机组，机组以发电机一变压器组单元接线接入220kV系统双母线，220kV配电装置采用双母线母联兼旁路母线接线方式’启动\u002F备用电源由老厂110kV母线引接。",[110,112,114,116],{"key":20,"text":111,"correct":32},"煤场面积为10000m2,用投光灯提供照明，要求照度值为21x，投光灯安装高度为20m,该型号投光灯所用光源为高压内灯，光通量为200001m，效率为0.35。需投光灯的数量为（）个。",{"key":24,"text":113,"correct":22},"65",{"key":27,"text":115,"correct":22},"85 C-IO5",{"key":30,"text":117,"correct":22},"9.",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":30,"analysis":33},1023114,"某500kV变电站，500kV配电装置拟采用悬吊管母、断路器三列式布置、主变压器低构架横穿进串的屋外中型配电装置；220kV配电装置采用悬吊管母、分相中型、断路器单列布置；35kV采用软母线中型布置，断路器双列布置，500kV保护小室布置在串间；220kV保布置在配电装置分段间隔出线构架间；主变压器、35kV保护小室1个，布置在配电装置内，站前区布置有主控制楼，试回答下列各题： 本站照明网络的接地型式，宜采用（）系统。",[122,124,126,128],{"key":20,"text":123,"correct":22},"TN；",{"key":24,"text":125,"correct":22},"TN-C；",{"key":27,"text":127,"correct":22},"TN-S；",{"key":30,"text":129,"correct":32},"TN-C-S.",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},1023115,"某500kV变电站，500kV配电装置拟采用悬吊管母、断路器三列式布置、主变压器低构架横穿进串的屋外中型配电装置；220kV配电装置采用悬吊管母、分相中型、断路器单列布置；35kV采用软母线中型布置，断路器双列布置，500kV保护小室布置在串间；220kV保布置在配电装置分段间隔出线构架间；主变压器、35kV保护小室1个，布置在配电装置内，站前区布置有主控制楼，试回答下列各题： 照明网络的接地电阻，不应大于（）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"R≤2000\u002FI；",{"key":24,"text":137,"correct":32},"4Ω；",{"key":27,"text":139,"correct":22},"10Ω；",{"key":30,"text":141,"correct":22},"30Ω。",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},1023116,"某500kV变电站，500kV配电装置拟采用悬吊管母、断路器三列式布置、主变压器低构架横穿进串的屋外中型配电装置；220kV配电装置采用悬吊管母、分相中型、断路器单列布置；35kV采用软母线中型布置，断路器双列布置，500kV保护小室布置在串间；220kV保布置在配电装置分段间隔出线构架间；主变压器、35kV保护小室1个，布置在配电装置内，站前区布置有主控制楼，试回答下列各题： 本站应装设直流常明灯的房间为（）。",[146,148,150,152],{"key":20,"text":147,"correct":32},"主控制室；",{"key":24,"text":149,"correct":22},"继电器小室；",{"key":27,"text":151,"correct":22},"通信机房；",{"key":30,"text":153,"correct":22},"站长办公室。",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},1023117,"某500kV变电站，500kV配电装置拟采用悬吊管母、断路器三列式布置、主变压器低构架横穿进串的屋外中型配电装置；220kV配电装置采用悬吊管母、分相中型、断路器单列布置；35kV采用软母线中型布置，断路器双列布置，500kV保护小室布置在串间；220kV保布置在配电装置分段间隔出线构架间；主变压器、35kV保护小室1个，布置在配电装置内，站前区布置有主控制楼，试回答下列各题： 在主变压器低构架500kV横穿进串导线下设置路灯，路灯与进串导线的安全距离，应满足（）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"3800mm；",{"key":24,"text":161,"correct":32},"4550mm；",{"key":27,"text":163,"correct":22},"7500mm；",{"key":30,"text":165,"correct":22},"5800mm。",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},1023118,"某500kV变电站，500kV配电装置拟采用悬吊管母、断路器三列式布置、主变压器低构架横穿进串的屋外中型配电装置；220kV配电装置采用悬吊管母、分相中型、断路器单列布置；35kV采用软母线中型布置，断路器双列布置，500kV保护小室布置在串间；220kV保布置在配电装置分段间隔出线构架间；主变压器、35kV保护小室1个，布置在配电装置内，站前区布置有主控制楼，试回答下列各题：",[170,172,174,176],{"key":20,"text":171,"correct":22},"站内灯具在没有采取安全措施时，其安装高度不应低于（）。",{"key":24,"text":173,"correct":32},"2m；",{"key":27,"text":175,"correct":22},"2.2m；",{"key":30,"text":177,"correct":22},"2.5m； D。3m。",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":24,"analysis":33},1023119,"某500kV变电站，500kV配电装置拟采用悬吊管母、断路器三列式布置、主变压器低构架横穿进串的屋外中型配电装置；220kV配电装置采用悬吊管母、分相中型、断路器单列布置；35kV采用软母线中型布置，断路器双列布置，500kV保护小室布置在串间；220kV保布置在配电装置分段间隔出线构架间；主变压器、35kV保护小室1个，布置在配电装置内，站前区布置有主控制楼，试回答下列各题： 户外配电箱外壳防护等级应为（）。",[182,184,185,187],{"key":20,"text":183,"correct":22},"IP40；",{"key":24,"text":79,"correct":32},{"key":27,"text":186,"correct":22},"IP55；",{"key":30,"text":81,"correct":22},{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":27,"analysis":33},1023120,"某500kV变电站，500kV配电装置拟采用悬吊管母、断路器三列式布置、主变压器低构架横穿进串的屋外中型配电装置；220kV配电装置采用悬吊管母、分相中型、断路器单列布置；35kV采用软母线中型布置，断路器双列布置，500kV保护小室布置在串间；220kV保布置在配电装置分段间隔出线构架间；主变压器、35kV保护小室1个，布置在配电装置内，站前区布置有主控制楼，试回答下列各题： 在三相四线制照明回路（光源为气体放电光源）中，中性线截面应按（）选择。",[192,194,196,198],{"key":20,"text":193,"correct":22},"最小负荷相的电流；",{"key":24,"text":195,"correct":22},"最小、最大负荷相电流的平均值；",{"key":27,"text":197,"correct":32},"最大负荷相的电流；",{"key":30,"text":199,"correct":22},"最大负荷相电流的50%。",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":24,"analysis":33},1023121,"某500kV变电站，500kV配电装置拟采用悬吊管母、断路器三列式布置、主变压器低构架横穿进串的屋外中型配电装置；220kV配电装置采用悬吊管母、分相中型、断路器单列布置；35kV采用软母线中型布置，断路器双列布置，500kV保护小室布置在串间；220kV保布置在配电装置分段间隔出线构架间；主变压器、35kV保护小室1个，布置在配电装置内，站前区布置有主控制楼，试回答下列各题： 照明线路穿管敷设时，导线（包括绝缘层）截面积的总和不应超过管子内截面的（）。",[204,206,208,210],{"key":20,"text":205,"correct":22},"30%；",{"key":24,"text":207,"correct":32},"40%；",{"key":27,"text":209,"correct":22},"50%；",{"key":30,"text":211,"correct":22},"60%。",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":27,"analysis":33},1023122,"某500kV变电站，500kV配电装置拟采用悬吊管母、断路器三列式布置、主变压器低构架横穿进串的屋外中型配电装置；220kV配电装置采用悬吊管母、分相中型、断路器单列布置；35kV采用软母线中型布置，断路器双列布置，500kV保护小室布置在串间；220kV保布置在配电装置分段间隔出线构架间；主变压器、35kV保护小室1个，布置在配电装置内，站前区布置有主控制楼，试回答下列各题： 由专门支路供电的插座回路，插座数量宜为（）个。",[216,218,220,222],{"key":20,"text":217,"correct":22},"5~10；",{"key":24,"text":219,"correct":22},"10~15；",{"key":27,"text":221,"correct":32},"15~20；",{"key":30,"text":223,"correct":22},"20~25。",{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":24,"analysis":33},1023123,"某500kV变电站，500kV配电装置拟采用悬吊管母、断路器三列式布置、主变压器低构架横穿进串的屋外中型配电装置；220kV配电装置采用悬吊管母、分相中型、断路器单列布置；35kV采用软母线中型布置，断路器双列布置，500kV保护小室布置在串间；220kV保布置在配电装置分段间隔出线构架间；主变压器、35kV保护小室1个，布置在配电装置内，站前区布置有主控制楼，试回答下列各题： 布置照明灯杆时，应避开上下水道、管沟等地下设施，并与消防栓保持（）距离。",[228,230,231,233],{"key":20,"text":229,"correct":22},"1m；",{"key":24,"text":173,"correct":32},{"key":27,"text":232,"correct":22},"3m；",{"key":30,"text":234,"correct":22},"5m。",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":27,"analysis":33},1023124,"电线上风荷载昨计算是以风速V （m\u002Fs）的基本风压=W0=V2\u002F16（kg?f\u002Fm）=V2\u002F16 （N\u002Fm2）乘以风速在档距中不均匀的折减系数α，电线风载体型系数C和受风面积（m2）。 LGJ-300\u002F50,d=24.26mm,A=348.36mm2,但V=15m\u002Fs,其γ4[N\u002F（m?mm2）]为（）。",[239,241,243,245],{"key":20,"text":240,"correct":22},"0.935X10-2；",{"key":24,"text":242,"correct":22},"0.995X1O-2；",{"key":27,"text":244,"correct":32},"1.055X10-2；",{"key":30,"text":246,"correct":22},"1.125X10-2。",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":20,"analysis":33},1023125,"电线上风荷载昨计算是以风速V （m\u002Fs）的基本风压=W0=V2\u002F16（kg?f\u002Fm）=V2\u002F16 （N\u002Fm2）乘以风速在档距中不均匀的折减系数α，电线风载体型系数C和受风面积（m2）。 LGJ-300\u002F50,d=24.26mm,A=348.36mm2,V=15m\u002Fs,冰厚6=10mm，其γ5[N\u002F（m?mm2）]为（）。",[251,253,255,257],{"key":20,"text":252,"correct":32},"2.1X1O-2；",{"key":24,"text":254,"correct":22},"2.5X10-2；",{"key":27,"text":256,"correct":22},"2.8X10—2；",{"key":30,"text":258,"correct":22},"3.0X10—2。",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":30,"analysis":33},1023126,"电线在有风时实际承受的荷载应为水平与垂直荷载的相量和，无冰有风为γ6,有冰有风为γ7。",[263,265,267,269],{"key":20,"text":264,"correct":22},"LGJ-300\u002F50,γ4=3.407X1O——2N\u002F（m?mm2），35m\u002Fs风时的γ4=4.02X10一2N\u002F（m?mm2），其为（）。",{"key":24,"text":266,"correct":22},"4.911X10-2；",{"key":27,"text":268,"correct":22},"5.085X1O-2；",{"key":30,"text":270,"correct":32},"5.125X10-2；0.5.29X10-2。",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":27,"analysis":33},1023127,"电线在有风时实际承受的荷载应为水平与垂直荷载的相量和，无冰有风为γ6,有冰有风为γ7。 LGJ-300\u002F50,γ3=（2.73+3.40）X1O-2=6.13X1O-2 N\u002F（m?mm2）,35m\u002Fs风，γ5=2.1X.10-2 N\u002F（m?mm2）,其γ7为（）。",[275,277,279,281],{"key":20,"text":276,"correct":22},"6.0X1O-2；",{"key":24,"text":278,"correct":22},"6.2X10-2；",{"key":27,"text":280,"correct":32},"6.48X1O-2；",{"key":30,"text":282,"correct":22},"6.8X10-2。",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":20,"analysis":33},1023128,"工程实用的架空电线的曲线为抛物线方程，y=rx2\u002F2σ，在悬挂点等高，档距为1时， 最大弧垂fm（ym）出现x=l\u002F2。 LGJ—300\u002F50’档距400m，覆冰10mm，γ3=6.13X10-2N\u002F（m?mm2）,σ=107.8N\u002Fmm2,其弧垂为（）。",[287,289,291,293],{"key":20,"text":288,"correct":32},"11.4；",{"key":24,"text":290,"correct":22},"12.8；",{"key":27,"text":292,"correct":22},"13.4；",{"key":30,"text":294,"correct":22},"13.8。",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":24,"analysis":33},1023129,"工程实用的架空电线的曲线为抛物线方程，y=rx2\u002F2σ，在悬挂点等高，档距为1时， 最大弧垂fm（ym）出现x=l\u002F2。 LGJ-300\u002F50,档距400m，γ=3.4X10-2N\u002F（m.mm2），+15℃，无风应力σ=58.8N\u002Fmm2,其弧垂为（），",[299,301,303,305],{"key":20,"text":300,"correct":22},"10.5；",{"key":24,"text":302,"correct":32},"11.5；",{"key":27,"text":304,"correct":22},"12.5；",{"key":30,"text":306,"correct":22},"13.5。",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":20,"analysis":33},1023130,"在电线悬挂点等高时，两悬点间的直线距离为档距l（m）,沿电线曲线的长度为线长L（m）。 LGJ-400\u002F50,悬点等高，l=400m，覆冰弧垂为13.4m,其电线长度为（）。",[311,313,315,317],{"key":20,"text":312,"correct":32},"401.2m；",{"key":24,"text":314,"correct":22},"402.1m；",{"key":27,"text":316,"correct":22},"403.2m；",{"key":30,"text":318,"correct":22},"404.3ra。",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":24,"analysis":33},1023131,"在电线悬挂点等高时，两悬点间的直线距离为档距l（m）,沿电线曲线的长度为线长L（m）。 LGJ-400\u002F50,其悬点等高，l=400，最髙气温时弧垂为16m，其线长为（）。",[323,325,327,329],{"key":20,"text":324,"correct":22},"400.8m；",{"key":24,"text":326,"correct":32},"401.7m；",{"key":27,"text":328,"correct":22},"402.5m；",{"key":30,"text":330,"correct":22},"404.3m.",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":24,"analysis":33},1023132,"电线中某点应力σ（或张力T）的方向为曲线在该点切线方向。电线最低点切线方向为水平，应力也最小σ0（T0）.电线荷载从最低点向上沿曲线递增累加，到耐张杆塔挂线点，将荷载施加于杆塔。 导线 LGJ—300\u002F50,档距400m，覆冰10mm，fm=13.4m,单位重量P3=1.21+0.97=2.18kg?f\u002Fm,档距最低点T0=11X348.36=3832kg?f,其悬挂点张力T为（）。",[335,337,339,341],{"key":20,"text":336,"correct":22},"3840kg?f；",{"key":24,"text":338,"correct":32},"3861kg?f；",{"key":27,"text":340,"correct":22},"3950kg?f；",{"key":30,"text":342,"correct":22},"4010kg?f。",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":20,"analysis":33},1023133,"电线中某点应力σ（或张力T）的方向为曲线在该点切线方向。电线最低点切线方向为水平，应力也最小σ0（T0）.电线荷载从最低点向上沿曲线递增累加，到耐张杆塔挂线点，将荷载施加于杆塔。 导线LGJ—300\u002F50,档距400m，15℃：无冰时，fm=11.56m，最低点张力为T0=6X348.36=2090kg.f,电线自重1.21kg.f\u002Fm,悬挂点张力T为（）。",[347,349,351,353],{"key":20,"text":348,"correct":32},"2104kg?f；",{"key":24,"text":350,"correct":22},"2250kg?f；",{"key":27,"text":352,"correct":22},"2300kg?f；",{"key":30,"text":354,"correct":22},"2350kg.f。",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":24,"analysis":33},1023134,"架空地线因不输送电能，故多选用镀锌钢绞线，其截面和拉断力一般远小于导线。地线位于导线上方，发生故障将影响送电，甚至烧坏导线。故其安全性与导线同等重要，为协调导、地线的机械强度，过载能力和运行安全性，对不同截面的导线规定了地线使用钢绞线的最小截面。 LGJ—185\u002F30及以下导线其值为（）。",[359,361,363,365],{"key":20,"text":360,"correct":22},"GJ—25；",{"key":24,"text":362,"correct":32},"GJ-35；",{"key":27,"text":364,"correct":22},"GJ-50；",{"key":30,"text":366,"correct":22},"GJ-70。",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":27,"analysis":33},1023135,"架空地线因不输送电能，故多选用镀锌钢绞线，其截面和拉断力一般远小于导线。地线位于导线上方，发生故障将影响送电，甚至烧坏导线。故其安全性与导线同等重要，为协调导、地线的机械强度，过载能力和运行安全性，对不同截面的导线规定了地线使用钢绞线的最小截面。 LGJ—185\u002F45至LGJ—400\u002F50导线其值为（）。",[371,372,374,376],{"key":20,"text":360,"correct":22},{"key":24,"text":373,"correct":22},"GJ—35；",{"key":27,"text":375,"correct":32},"GJ-50,",{"key":30,"text":377,"correct":22},"GJ—70。",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":30,"analysis":33},1023136,"架空地线因不输送电能，故多选用镀锌钢绞线，其截面和拉断力一般远小于导线。地线位于导线上方，发生故障将影响送电，甚至烧坏导线。故其安全性与导线同等重要，为协调导、地线的机械强度，过载能力和运行安全性，对不同截面的导线规定了地线使用钢绞线的最小截面。 LGJ—400\u002F65及以上导线其值为（）。",[382,383,384,385],{"key":20,"text":360,"correct":22},{"key":24,"text":373,"correct":22},{"key":27,"text":364,"correct":22},{"key":30,"text":377,"correct":32},{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":30,"analysis":33},1023137,"导地线以数千公斤力紧绷于杆塔间，恰似一琴弦，在微风的吹佛下，产生自激振动。由于导地线的振动疲劳强度远小于抗拉强度，故： 导线在年平均运行应力下的安全系数应不小于（）。",[390,391,393,395],{"key":20,"text":101,"correct":22},{"key":24,"text":392,"correct":22},"3；",{"key":27,"text":394,"correct":22},"3.5；",{"key":30,"text":396,"correct":32},"4。",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":27,"analysis":33},1023138,"导地线以数千公斤力紧绷于杆塔间，恰似一琴弦，在微风的吹佛下，产生自激振动。由于导地线的振动疲劳强度远小于抗拉强度，故： 地线在年平均运行应力下的安全系数应不小于（）。",[401,402,403,405],{"key":20,"text":392,"correct":22},{"key":24,"text":394,"correct":22},{"key":27,"text":404,"correct":32},"4；",{"key":30,"text":406,"correct":22},"4.5。",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":24,"analysis":33},1023139,"送电线路是由若干耐张转角塔和其间的直线塔组成，两相邻耐张转角塔间构成一耐张段，导线在耐张转角塔经耐张绝缘子串固定在塔上。在其间的直线塔上导线悬挂在悬垂绝缘子串下端，可顺线偏斜或横向摆动。虽在施工架线时各档水平应力相同，但由于档距和高差不同，在气象条件变化后，各档应力就不相同了。从而在悬垂绝缘子下端出现不平衡张力’使绝缘子串产生偏斜，偏斜后使各档应力趋于基本相同。这个应力称为耐张段的代表应力。该代表应力对应的档距称为代表档距。 若某耐张段由档距400，300，450，350，500m组成，其代表档距Zr为（ ）。",[411,413,415,417],{"key":20,"text":412,"correct":22},"401m；",{"key":24,"text":414,"correct":32},"418m；",{"key":27,"text":416,"correct":22},"438m；",{"key":30,"text":418,"correct":22},"450m。",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":24,"analysis":33},1023140,"送电线路是由若干耐张转角塔和其间的直线塔组成，两相邻耐张转角塔间构成一耐张段，导线在耐张转角塔经耐张绝缘子串固定在塔上。在其间的直线塔上导线悬挂在悬垂绝缘子串下端，可顺线偏斜或横向摆动。虽在施工架线时各档水平应力相同，但由于档距和高差不同，在气象条件变化后，各档应力就不相同了。从而在悬垂绝缘子下端出现不平衡张力，使绝缘子串产生偏斜，偏斜后使各档应力趋于基本相同。这个应力称为耐张段的代表应力。该代表应力对应的档距称为代表档距。 某跨河耐张段由200，300，1000，300，200m组成，其代表档距（为（ ）。",[423,425,427,429],{"key":20,"text":424,"correct":22},"712m；",{"key":24,"text":426,"correct":32},"732m；",{"key":27,"text":428,"correct":22},"742m；",{"key":30,"text":430,"correct":22},"762m。",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":24,"analysis":33},1023141,"无论有无高差，一个档距中的电线受风后，电线承受的风压将平均地传递到两侧杆塔上，因此杆塔上承受的风压将是其两侧各半档风压之和，该两半档档距之和为水平档距 某直线塔两侧档距为350m和400m，导线LGJ—300\u002F50，35m\u002Fs,风压沿=1.43kg?f\u002Fm,该塔承受每相导线的风压为（）。",[435,437,439,441],{"key":20,"text":436,"correct":22},"510kg?f；",{"key":24,"text":438,"correct":32},"536kg.f；",{"key":27,"text":440,"correct":22},"580kg?f；",{"key":30,"text":442,"correct":22},"625kg.f。",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":27,"analysis":33},1023142,"无论有无高差，一个档距中的电线受风后，电线承受的风压将平均地传递到两侧杆塔上，因此杆塔上承受的风压将是其两侧各半档风压之和，该两半档档距之和为水平档距 某耐张塔，前侧档距为250m，后侧档距为450m,导线LGJ—300\u002F50,风15m\u002Fs，风压办=0.375kg.f，该塔承受每相导线的风压为（）。",[447,449,451,453],{"key":20,"text":448,"correct":22},"1OOkg?f；",{"key":24,"text":450,"correct":22},"125kg?f；",{"key":27,"text":452,"correct":32},"131kg.f；",{"key":30,"text":454,"correct":22},"152kg.f。",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":24,"analysis":33},1023143,"无论有无髙差，一个档距中电线的重量，将从其弧垂最低点分别传递到两侧杆塔上，该最低点到杆塔的距离称为该杆塔该侧的垂直档距（l1v或l2v），杆塔总的垂直档距lv=l1v+l2v。 某直线塔位于斜坡上，l1=350m，h1= 70m,l2=400m,h2=—60m，σ=58.8N\u002Fmm2,7=3.4X1O-2 N\u002F（m?mm2）。 其垂直档距为（）。",[459,461,463,465],{"key":20,"text":460,"correct":22},"452m；",{"key":24,"text":462,"correct":32},"461m；",{"key":27,"text":464,"correct":22},"482m；",{"key":30,"text":466,"correct":22},"513m。",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":27,"analysis":33},1023144,"无论有无髙差，一个档距中电线的重量，将从其弧垂最低点分别传递到两侧杆塔上，该最低点到杆塔的距离称为该杆塔该侧的垂直档距（l1v或l2v），杆塔总的垂直档距lv=l1v+l2v。 某耐张塔位于陡坡上，h1=250m，h1=-100m,σ1=58.8N\u002Fmm2,l2=450m,h2=1OOm,σ2=60.76N\u002Fmm2；γ=3.4X1O-2N\u002F（m.mm2）。 其前后侧垂直档距llv\u002F来v（m）（耐张塔绝缘子串挂点分别在横担前，后侧，且可能出现上拔力，故分开计算）为（）。",[471,473,475,477],{"key":20,"text":472,"correct":22},"-547\u002F602；",{"key":24,"text":474,"correct":22},"-557\u002F612；",{"key":27,"text":476,"correct":32},"-567\u002F622；",{"key":30,"text":478,"correct":22},"—577\u002F632。",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":30,"analysis":33},1023145,"杆塔挂线点承受的电线垂直荷载为其前后侧电线最低点间电线的重量（自重或自重加冰重）。 P=P0（l1v+l2v）=P0lv 式中P0——每米线重，kg?f； lv——垂直档距，m。 某直线塔lv=461.5m，LGJ—300\u002F50导线自重P0=1.21kg?f\u002Fm，每相导线垂直荷载为（）N。",[483,485,487,489],{"key":20,"text":484,"correct":22},"5120；",{"key":24,"text":486,"correct":22},"5580；",{"key":27,"text":488,"correct":22},"6120=；",{"key":30,"text":490,"correct":32},"5472,",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":27,"analysis":33},1023146,"杆塔挂线点承受的电线垂直荷载为其前后侧电线最低点间电线的重量（自重或自重加冰重）。 P=P0（l1v+l2v）=P0lv 式中P0——每米线重，kg?f； lv——垂直档距，m。 某耐张塔l1v=567m，l2v=622m LGJ300\u002F50导线，自重P0=1.21kg?f\u002Fm,每相导线前后侧挂点的垂直荷载为（）。",[495,497,499,501],{"key":20,"text":496,"correct":22},"-5500\u002F5800；",{"key":24,"text":498,"correct":22},"—6470\u002F6950；",{"key":27,"text":500,"correct":32},"-6724\u002F7376；",{"key":30,"text":502,"correct":22},"-7120\u002F7500.",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":24,"analysis":33},1023147,"导线风压传递给悬垂绝缘子串下端，引起绝缘子串横向摇摆，称为悬垂绝缘子串的摇摆角。 每一种直线杆塔对大气，操作过电压和大风时工作电压，有最大允许摇摆角，超过该角度即霱要更换更大的塔型，甚至改为耐张塔。也可调整杆塔位置和髙度以增大垂直档距，减小摇摆角。 LGJ—300\u002F50导线，自重1.21kg?f\u002Fm,大风（35m\u002Fs）时，风压1.43kg?f\u002Fm,lv=280m，lH=400m,绝缘子串风压22kg?f，质量70kg，其摇摆角为（）。",[507,509,511,513],{"key":20,"text":508,"correct":22},"55°；",{"key":24,"text":510,"correct":32},"59°；",{"key":27,"text":512,"correct":22},"62°；",{"key":30,"text":514,"correct":22},"65°。",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":24,"analysis":33},1023148,"导线风压传递给悬垂绝缘子串下端，引起绝缘子串横向摇摆，称为悬垂绝缘子串的摇摆角。 每一种直线杆塔对大气，操作过电压和大风时工作电压，有最大允许摇摆角，超过该角度即霱要更换更大的塔型，甚至改为耐张塔。也可调整杆塔位置和髙度以增大垂直档距，减小摇摆角。 LGJ—300\u002F50导线，自重1.21kg.f\u002Fm,大气过电压时（15m\u002Fs），风压0.375kg.f\u002Fm，lv=300m，lH=4OOm,绝缘子串风压4kg?f，质量70kg，其摇摆角为（）。",[519,521,523,525],{"key":20,"text":520,"correct":22},"20°；",{"key":24,"text":522,"correct":32},"23°；",{"key":27,"text":524,"correct":22},"26°；",{"key":30,"text":526,"correct":22},"29°。",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":27,"analysis":33},1023149,"由于架空线路的档距很大，当气象条件变化时，导线的弹性伸长和温度膨胀对应力和弧垂影响很大，如最髙气温时，弧垂最大，即系温度膨胀所致。覆冰时，弧垂剧增，即系应力增加，弹性伸长所致。 钢芯铝绞线系两种材质绞合而成，其伸长应相等。若不考虑扭绞的影响，其综合弹性系数E和线性膨胀系数α，除与铝、钢的α、E有关外，还与铝钢截面比有关。 以铝线30股，钢芯7股，股线直径相同的结构（如LGJ—185\u002F45，LGJ-210\u002F50, 综合弹性系数E （N\u002Fmm2）为（）。",[531,533,535,537],{"key":20,"text":532,"correct":22},"81500；",{"key":24,"text":534,"correct":22},"83000,",{"key":27,"text":536,"correct":32},"84900；",{"key":30,"text":538,"correct":22},"85500。",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":24,"analysis":33},1023150,"由于架空线路的档距很大，当气象条件变化时，导线的弹性伸长和温度膨胀对应力和弧垂影响很大，如最髙气温时，弧垂最大，即系温度膨胀所致。覆冰时，弧垂剧增，即系应力增加，弹性伸长所致。 钢芯铝绞线系两种材质绞合而成，其伸长应相等。若不考虑扭绞的影响，其综合弹性系数E和线性膨胀系数α，除与铝、钢的α、E有关外，还与铝钢截面比有关。 以铝线30股，钢芯7股，股线直径相同的结构（如LGJ—185\u002F45，LGJ-210\u002F50, 综合线膨胀系数α（l\u002F℃）为（）。",[543,545,547,549],{"key":20,"text":544,"correct":22},"17.5X10-6；",{"key":24,"text":546,"correct":32},"18.2X1O-6；",{"key":27,"text":548,"correct":22},"19.3X10-6；",{"key":30,"text":550,"correct":22},"19.7X-6。",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":20,"analysis":33},1023151,"由于该式为σ的三次方程，求解较繁，现均由程序计算。 电线最大允许使用应力σm（拉断应力除额定安全系数），一般出现在电线覆冰设计最大冰的气象条件（―5℃，有冰，有风，γ7），以此为起始条件，可推算电线运行中各种气象条件（γ，t）的应力σ（在北方寒冷地区的小档距，最大应力也可能出现在最低气温，在无冰、轻冰的南方温热地区，最大应力也可能由大风或防震控制，则相应变为起始的计算气象条件）。 若在温度t时架线施工，为保证架成后电线在各种气象条件的应力弧垂符合设计预期值，从起始条件（σm，γ7,-5℃）算出架线施工应力σ的气象条件为（）。",[555,557,559,561],{"key":20,"text":556,"correct":32},"溫度t，无冰，无风；",{"key":24,"text":558,"correct":22},"温度t，无冰，10m\u002Fs风；",{"key":27,"text":560,"correct":22},"15℃,无冰、无风；",{"key":30,"text":562,"correct":22},"最高气温，无冰，无风。",{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":24,"analysis":33},1023152,"由于该式为σ的三次方程，求解较繁，现均由程序计算。 电线最大允许使用应力σm（拉断应力除额定安全系数），一般出现在电线覆冰设计最大冰的气象条件（―5℃，有冰，有风，γ7），以此为起始条件，可推算电线运行中各种气象条件（γ，t）的应力σ（在北方寒冷地区的小档距，最大应力也可能出现在最低气温，在无冰、轻冰的南方温热地区，最大应力也可能由大风或防震控制，则相应变为起始的计算气象条件）。 为计算杆塔设计荷载，除最大应力外，还应从起始条件，算出（）气象条件的应力。",[567,569,571,573],{"key":20,"text":568,"correct":22},"最高气温；",{"key":24,"text":570,"correct":32},"最大设计风速；",{"key":27,"text":572,"correct":22},"大气过电压；",{"key":30,"text":574,"correct":22},"操作过电压。",{"id":576,"libraryId":5,"type":15,"typeLabel":16,"stem":577,"options":578,"answer":24,"analysis":33},1023153,"由于该式为σ的三次方程，求解较繁，现均由程序计算。 电线最大允许使用应力σm（拉断应力除额定安全系数），一般出现在电线覆冰设计最大冰的气象条件（―5℃，有冰，有风，γ7），以此为起始条件，可推算电线运行中各种气象条件（γ，t）的应力σ（在北方寒冷地区的小档距，最大应力也可能出现在最低气温，在无冰、轻冰的南方温热地区，最大应力也可能由大风或防震控制，则相应变为起始的计算气象条件）。 在选定杆塔位置和髙度时，还应从起始条件算出（）气象条件的应力。",[579,581,583,584],{"key":20,"text":580,"correct":22},"最低气温；",{"key":24,"text":582,"correct":32},"最髙气温；",{"key":27,"text":572,"correct":22},{"key":30,"text":574,"correct":22},{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":20,"analysis":33},1023154,"电线架设时，并非测量施工张力，而是观测施工弧垂，因此要将求得的施工应力换算为施工弧垂（f=γl2\u002F8σ）曲线交付施工运行。由于悬垂绝缘子串可自由偏斜，故一个耐张段内各档的应力基本相同，即代表档距的应力，若选定观測档的档距为l，即可用代表档距的应力，观測档的档距，算出弧垂。 一条线路有许多代表档距，施工弧垂曲线的制作以（）档距算出弧垂曲线。",[589,591,593,595],{"key":20,"text":590,"correct":32},"设定的等间距代表档距；",{"key":24,"text":592,"correct":22},"实际的代表档距；",{"key":27,"text":594,"correct":22},"观测档距；",{"key":30,"text":596,"correct":22},"实际的档距。",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":20,"analysis":33},1023155,"电线架设时，并非测量施工张力，而是观测施工弧垂，因此要将求得的施工应力换算为施工弧垂（f=γl2\u002F8σ）曲线交付施工运行。由于悬垂绝缘子串可自由偏斜，故一个耐张段内各档的应力基本相同，即代表档距的应力，若选定观測档的档距为l，即可用代表档距的应力，观測档的档距，算出弧垂。 —条线路的施工期很长，春夏秋冬都可能架线，施工弧垂曲线的制作是（）。",[601,603,605,607],{"key":20,"text":602,"correct":32},"以等间係的温度为参变量，制作一組档距弧垂曲线；",{"key":24,"text":604,"correct":22},"以实际的架线温度制作档距孤垂曲线；",{"key":27,"text":606,"correct":22},"以規定的架线温度制作档距孤垂曲线；",{"key":30,"text":608,"correct":22},"以春夏秋冬四季制作代表性的档距弧垂曲线。",[610,613,616,619,622,625],{"id":15,"name":611,"category":7,"favorite":612},"领导干部任职前廉政法规知识测试题",92,{"id":614,"name":615,"category":7,"favorite":15},595,"建筑结构与设备",{"id":617,"name":618,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":620,"name":621,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":623,"name":624,"category":7,"favorite":8},534,"BIM工程师",{"id":626,"name":624,"category":7,"favorite":8},535]