[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-27":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":609},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,27,50,2670,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,310,322,334,346,358,370,382,390,402,413,423,435,445,457,467,479,491,503,515,526,538,550,562,573,585,597],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1023055,1,"单选题","火力发电厂厂用电备用电源配置方式和原则正确的是（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","接有I类负荷的暗备用动力中心应装设备用电源自动投入装置；",false,{"key":24,"text":25,"correct":26},"B","只有III类负荷的厂用母线，可无备用电源；",true,{"key":28,"text":29,"correct":22},"C","接有II类负荷和I类负荷的明备用的厂用动力中心备用电源宜采用手动切換；",{"key":31,"text":32,"correct":22},"D","厂用母线的备用电源切换方式应根据需要设置。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},1023056,"某大型燃煤电厂2X600MW机组厂用电采用3、10kV两级电压，其供电设备的额定电压应取（)。",[38,40,42,44],{"key":20,"text":39,"correct":22},"3kV、10.5kV；",{"key":24,"text":41,"correct":22},"3.15kV、10kV；",{"key":28,"text":43,"correct":26},"3.15kV,10.5kV；",{"key":31,"text":45,"correct":22},"3kV、10kV。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},1023057,"低压厂用电中的断路器安装地点的预期短路电流值，系指分断瞬间一个周波内的周期分量有效值，对动作时间大于（）的断路器，可不计电动机反馈电流的影响。",[50,52,54,56],{"key":20,"text":51,"correct":22},"2个周波；",{"key":24,"text":53,"correct":22},"3个周波；",{"key":28,"text":55,"correct":26},"4个周波；",{"key":31,"text":57,"correct":22},"5个周波。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},1023058,"火力发电厂采用柴油发电机作交流保安电源时，需对柴油机1h的负载能力（1.1px进行校验，要求：1.1px≥αPc\u002FηG(Pc为计算负荷的有功功率；免为发电机效率)，式中配合系数α应取（）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"1.05~1.1；",{"key":24,"text":65,"correct":22},"1.15~1.2；",{"key":28,"text":67,"correct":26},"1.1~1.15；",{"key":31,"text":69,"correct":22},"1.15~1.2。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},1023059,"水电厂厂用电动机启动时，电压校验应()。 A.在正常启动母线电压降不大于",[74,76,78,80],{"key":20,"text":75,"correct":22},"电动机自启动应按厂用电正常的接线方式和运行方式进行；",{"key":24,"text":77,"correct":22},"厂用电为两级电压时，应对髙、低压母线串接自启动进行校",{"key":28,"text":79,"correct":26},"低压电动机額定功率（kW)不小于20%变压器額定容量（kV",{"key":31,"text":81,"correct":22},"时，可不校检电动机正常启动的母线电压。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},1023060,"电动机降压启动方式：①延边三角形降压启动；②自偶变压器降压启动；③星一三角形降压启动；④软启动器启动；⑤电抗器降压启动中，对一般鼠笼电动机若需降压启动。则选择的次序为（）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"①②③④⑤；",{"key":24,"text":89,"correct":22},"③②①④⑤；",{"key":28,"text":91,"correct":22},"③①②⑤④；",{"key":31,"text":93,"correct":26},"③①②④⑤。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},1023061,"水电厂高压厂用电系统短路电流计算时，当同时运行的高压电动机总容量不大于()时，可不计及电动机的反馈电流。",[98,100,102,104],{"key":20,"text":99,"correct":22},"1200kW,",{"key":24,"text":101,"correct":26},"1500kW；",{"key":28,"text":103,"correct":22},"1800kW,",{"key":31,"text":105,"correct":22},"2000kW。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},1023062,"火力发电厂厂用电设计应达到的要求是（）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"满足建设（甲方）的要求；",{"key":24,"text":113,"correct":22},"符合地方政府的要求；",{"key":28,"text":115,"correct":22},"达到投资最少的要求；",{"key":31,"text":117,"correct":26},"达到安全可靠、经济适用、符合国情的要求,",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},1023063,"发电厂厂用电负荷按生产过程中的重要性可分为（）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"4类；",{"key":24,"text":125,"correct":22},"2类；",{"key":28,"text":127,"correct":22},"5类；",{"key":31,"text":129,"correct":26},"3类。",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":28,"analysis":33},1023064,"火力发电厂厂用电负荷属于“ I”类负荷的情况有()。",[134,136,138,140],{"key":20,"text":135,"correct":22},"允许短时停电，停电时间过长，有可能损坏设备；",{"key":24,"text":137,"correct":22},"较长时间停电不影响生产运行；",{"key":28,"text":139,"correct":26},"短时伴电可能影响人身和设备安全，使生产停顿或发电量大量下降；",{"key":31,"text":141,"correct":22},"短时停电不影响人身安全，但影响设备安全。",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},1023065,"火力发电厂厂用电系统中，以下提法正确的有（）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"与发电厂生产无关的附近居民用电负荷也可接入厂用电系统；",{"key":24,"text":149,"correct":26},"与发电厂生产无关的负荷不应接入厂用电系统；",{"key":28,"text":151,"correct":22},"电厂行政办公楼、值班宿舍负荷可直接接至厂用低压系统,不需专用变压器；",{"key":31,"text":153,"correct":22},"电厂相邻的工厂企业用电也可接至电厂厂用电系统。",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},1023066,"火力发电厂厂用电的交流保安负荷供电要求一般采用（）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"由电厂附近的变电所专引一田电源供保安负荷；",{"key":24,"text":161,"correct":26},"平时由电厂的交流厂用电供电，失去厂用工作和备用电源时，交流保安电源（采用快速自启动的柴油发电机组）应自动投入；",{"key":28,"text":163,"correct":22},"利用蓄电池逆变供电；",{"key":31,"text":165,"correct":22},"由电厂附近的工厂企业的变电所引一回电源供电厂保安负荷，",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},1023067,"容量为125~300MW级的机组发电厂髙压厂用电电压宜采用的电压级为（）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"3kV；",{"key":24,"text":173,"correct":26},"6kV；",{"key":28,"text":175,"correct":22},"10kV；",{"key":31,"text":177,"correct":22},"3、10kV两级。",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":24,"analysis":33},1023068,"200MW及以上机组主厂房内的低压厂用电供电方式和电压，下述选项正确的是（）。",[182,184,186,188],{"key":20,"text":183,"correct":22},"应采用动力和照明合用供电方式，电压宜采用380V\u002F220V；",{"key":24,"text":185,"correct":26},"应采用动力与照明分开供电方式，动力网络电压宜采用380V；",{"key":28,"text":187,"correct":22},"采用动力与照明分开供电方式，动力网络电压采用660V；",{"key":31,"text":189,"correct":22},"采用动力与照明分用的供电方式，电压采用660V\u002F380V。",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":24,"analysis":33},1023069,"火力发电厂高压厂用电母线应采用的接线方式是（）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"采用单母线分段接线，由1台变压器供电，双套辅机分接于两段上；",{"key":24,"text":197,"correct":26},"采用单母接线，锅炉容量为400t\u002Fh及以上时每台锅炉每一级高压厂用电压应不少于2段，双套辅机分接在两段母线上，两段母线可由1台变压器供电；",{"key":28,"text":199,"correct":22},"采用双母线接线，锅炉容量为400t\u002Fh以上时由两台变压器供电，双套辅机分接在I母线或n母线上；",{"key":31,"text":201,"correct":22},"采用单母线分段接线，由2台变压器供电，双套辅机分接在一、二段母线上。",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":24,"analysis":33},1023070,"对于火力发电厂低压厂用母线，以下做法正确的是()。",[206,208,210,212],{"key":20,"text":207,"correct":22},"锅炉容量为220t\u002Fh级，低压厂用母线采用单母线接线，应按机炉对应分段；",{"key":24,"text":209,"correct":26},"锅炉容量为1000t\u002Fh级及以上时，低压厂用母线采用单母线接线，每台锅炉应设里2段及以上母线；",{"key":28,"text":211,"correct":22},"容量为400~670T\u002Fh锅炉，低压厂用母线每台炉可由一段母线供电，采用单母线接线；",{"key":31,"text":213,"correct":22},"容量为400~670T\u002Fh锅炉，厂用低压接线采用单母线，每台炉可由二段母线供电，两段母线应由1台变压器供电。",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":31,"analysis":33},1023071,"火力发电厂厂用高压母线接线中关于公用段母线的设置，正确的是（）。",[218,220,222,224],{"key":20,"text":219,"correct":22},"新建大、中型火力发电厂均应设公用段；",{"key":24,"text":221,"correct":22},"公用段应由启动\u002F备用变压器供电；",{"key":28,"text":223,"correct":22},"电厂首台机组与扩建机组相隔时间长（计划不确定等）应设公用段母线；",{"key":31,"text":225,"correct":26},"是否设公用段应进行设计优化，经技术经济综合比较后，再确定。",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":28,"analysis":33},1023072,"火力发电厂采用发电机变压器组单元接线，厂用工作电源由发电机出口引接，厂用引接分支线采用离相封闭母线时，分支线上关于应装设备或其他设施的叙述中正确的是（）。",[230,232,234,236],{"key":20,"text":231,"correct":22},"应装设断路器；",{"key":24,"text":233,"correct":22},"应装设隔离开关，不设断路器；",{"key":28,"text":235,"correct":26},"应装设可拆连接片；",{"key":31,"text":237,"correct":22},"不装设任何设备和设施。",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":28,"analysis":33},1023073,"火力发电厂200~300MW机组的高压厂用工作电源宜采用（）。",[242,244,246,248],{"key":20,"text":243,"correct":22},"1台双绕组变压器；",{"key":24,"text":245,"correct":22},"1台三绕组变压器；",{"key":28,"text":247,"correct":26},"1台分裂变压器；",{"key":31,"text":249,"correct":22},"2台双绕組变压器。",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":28,"analysis":33},1023074,"火力发电厂接有I类负荷的厂用电低压PC母线，考虑其备用电源设置，下列说法正确的是（)。",[254,256,258,260],{"key":20,"text":255,"correct":22},"应设1个备用电源（暗备用方式），装设备用电源自动投入装里；",{"key":24,"text":257,"correct":22},"应设1个备用电源（暗备用方式），采用手动切换或自动切换；",{"key":28,"text":259,"correct":26},"应设1个备用电源（明备用方式），装设备用电源自动投入装置；",{"key":31,"text":261,"correct":22},"应设1个备用电源（明备用方式），采用手动切换。",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":28,"analysis":33},1023075,"火力发电厂容量为200~300MW机组，高压厂用启动\u002F备用变压器设置条件中，正确的是（）。",[266,268,270,272],{"key":20,"text":267,"correct":22},"高压厂用工作变压器数量在5台及以上可増设第2台髙压厂用启动\u002F备用变压器；",{"key":24,"text":269,"correct":22},"每3台机组可设1台高压厂用启动\u002F备用变压器；",{"key":28,"text":271,"correct":26},"每2台机组可设1台高压厂用启动\u002F备用变压器；",{"key":31,"text":273,"correct":22},"每台机組设1台高压厂用启动\u002F备用变压器。",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":24,"analysis":33},1023076,"火力发电厂容量为600MW机组，高压厂用启动\u002F备用变压器设置条件中，正确的是（）。",[278,280,282,284],{"key":20,"text":279,"correct":22},"当发电机出口不装断路器或负荷开关时，每台机组应设1台启动\u002F备用变压器；",{"key":24,"text":281,"correct":26},"当发电机出口不装断路器或负荷开关时，每2台机组应设1台或2台启动\u002F备用变压器；",{"key":28,"text":283,"correct":22},"当发电机出口装有断路器或负荷开关时，3台及以下机組可设置1台高压启动\u002F备用变压器i",{"key":31,"text":285,"correct":22},"当发电机出口装有断路器或负荷开关时，5台及以下机组可设置1台高压启动\u002F备用变压器。",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":28,"analysis":33},1023077,"火力发电厂低压厂用备用电源采用明备用时，关于备用变压器的配置，正确的是()。",[290,292,294,296],{"key":20,"text":291,"correct":22},"容量为125MW及以下的机组，低压厂用工作变压器数量在6台及以上时，可増设第2台低压广用备用变压器？",{"key":24,"text":293,"correct":22},"容量为200MW的机组，每3台机组可合用1台低压厂用备用变压器；",{"key":28,"text":295,"correct":26},"容量为300MW及以上的机组，每台机组宜设1台低压厂用备用变压器；",{"key":31,"text":297,"correct":22},"容量为300MW及以上的机组，每2台机组可合用1台低压厂用备用变压器，",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":28,"analysis":33},1023078,"火力发电厂髙压厂用启动\u002F备用电源的引接，正确的是（）。",[302,304,306,308],{"key":20,"text":303,"correct":22},"由发电机出口引接备用电源；",{"key":24,"text":305,"correct":22},"无发电机电压母线时，由高压母线t电源可靠的最高一级电压母线引接；",{"key":28,"text":307,"correct":26},"无发电机电压母线时，由高压母线中电源可靠的最低一级电压母线或由联络变压器的第3(低压）绕组引接，并应保证在全厂停电的情况下，能保证外部电力系统取得足够的电源（包栝三桡组变压器的中压側从高压侧取得电源）；",{"key":31,"text":309,"correct":22},"无发电机电压母线，高压母线与系统联系可靠，可从该高压母线引接，另外还需从外部电网51接1回专用线路作备用电源。",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":24,"analysis":33},1023079,"火力发电厂低压厂用备用变压器引接方式正确的是（）。",[314,316,318,320],{"key":20,"text":315,"correct":22},"低压厂用备用变压器宜与需要由其自动投入的低压厂用工作变压器接在同一髙压母线段上；",{"key":24,"text":317,"correct":26},"低压厂用备用变压器不宜与需要由其自动投入的低压厂用工作变压器接在同一高压母线段上；",{"key":28,"text":319,"correct":22},"C低压厂用工作变压器台数少于高压母线段数时，备用变压器可由任一高压母线段引接；",{"key":31,"text":321,"correct":22},"低压厂用备用变压器宜接至外部电网引接的可靠专用线路上。",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":31,"analysis":33},1023080,"髙压厂用电器选择应校验热稳定，即I2t Qt，Qt为计算时间ts内短路电流的热效应，Qt计算时，（）。",[326,328,330,332],{"key":20,"text":327,"correct":22},"对10OMW及以下机组，应计及电动机反馈电流热效应对电器热稳定的影响；",{"key":24,"text":329,"correct":22},"对125MW及以上机组，可不计及电动机反馈电流热效应对电器热稳定的影响；",{"key":28,"text":331,"correct":22},"对125MW及以上机组，热效应可按Qt =I2Bt计算（I2B为厂用电源短路电流周期分量的起始有效值）；",{"key":31,"text":333,"correct":26},"对125MW及以上机组，应计及电动机反馈电流热效应对电器热穩定的影响。",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":28,"analysis":33},1023081,"火力发电厂高压厂用工作变压器的容量选择，正确的是（）。 A.按所有高压电动机容量（kW)与低压厂用变压器（kV",[338,340,342,344],{"key":20,"text":339,"correct":22},"容量之和选择；",{"key":24,"text":341,"correct":22},"按所有髙压电动机与低压电动机总容量（kW)，并考虑功率因数修正后计算结果选择；",{"key":28,"text":343,"correct":26},"C按高压电动机厂用计算负荷（用换算系.数法）与低压厂用电计算负荷（换算系数法）之和选择丨",{"key":31,"text":345,"correct":22},"按所有高压电动机容量之和乘以同时率的计算结果和低压厂用电计算负荷之和选择。",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":28,"analysis":33},1023082,"火力发电厂髙压厂用备用变压器或启动\u002F备用变压器容量选择，正确的一条是（）。",[350,352,354,356],{"key":20,"text":351,"correct":22},"高压厂用启动\u002F备用变压器应不大于最小1台（组）高压厂用工作变压器的容量；",{"key":24,"text":353,"correct":22},"高压厂用启动\u002F备用变压器应不小于最小1台（组）和最大1台（组）高压厂用工作变压器平均容量；",{"key":28,"text":355,"correct":26},"高压厂用启动\u002F备用变压器应不小于最大1台（组）高压厂用工作变压器的容量；当启动\u002F备用变压器带有公用负荷时，其容量还应满足最大1台（组）高压厂用工作变压器备用要求；",{"key":31,"text":357,"correct":22},"对于单元制接线的发电机，当发电机出口装有断路器时高压厂用备用变压器的容量可为1台高压厂用工作变压器的50%。",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":28,"analysis":33},1023083,"在正常的电源电压偏移和厂用负荷波动的情况下，火力发电厂厂用电各级母线的电压偏移不应超过额定电压的（）。",[362,364,366,368],{"key":20,"text":363,"correct":22},"±10%；",{"key":24,"text":365,"correct":22},"±7；",{"key":28,"text":367,"correct":26},"±5%；",{"key":31,"text":369,"correct":22},"±2.5%。",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":28,"analysis":33},1023084,"火力发电厂发电机出口无断路器或负荷开关时，出口引接的高压厂用工作变压器及阻抗选择，下述正确的是（）。",[374,376,378,380],{"key":20,"text":375,"correct":22},"采用有载调压变压器，阻抗电压采用13%；",{"key":24,"text":377,"correct":22},"采用无载调压变压器，阻抗电压釆用12%；",{"key":28,"text":379,"correct":26},"采用无载调压变压器，阻抗电压不大于10.5%；",{"key":31,"text":381,"correct":22},"采用有载调压变压器，阻抗电压采用15%。",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":28,"analysis":33},1023085,"火力发电厂高压厂用备用变压器引接点的电压波动超过()时应采用有载调压变压器。 A.±10%； B.±7.5%； C±5%； D.±2.5%。",[386,387,388,389],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":20,"analysis":33},1023086,"当灯具悬挂髙度在4m及以下时，光源宜采用（）。",[394,396,398,400],{"key":20,"text":395,"correct":26},"荧光灯；",{"key":24,"text":397,"correct":22},"高压钠灯；",{"key":28,"text":399,"correct":22},"荧光髙压汞灯；",{"key":31,"text":401,"correct":22},"白炽灯。",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":24,"analysis":33},1023087,"当灯具悬挂高度在4m以上时，光源宜采用（）。",[406,407,409,411],{"key":20,"text":395,"correct":22},{"key":24,"text":408,"correct":26},"高强气体放电灯；",{"key":28,"text":410,"correct":22},"白炽灯；",{"key":31,"text":412,"correct":22},"卤钨灯。",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":24,"analysis":33},1023088,"在蒸汽浓度较大或灰尘较多的场所，光源宜采用（）。",[417,418,420,422],{"key":20,"text":395,"correct":22},{"key":24,"text":419,"correct":26},"髙压钠灯；",{"key":28,"text":421,"correct":22},"荧光高压汞灯；",{"key":31,"text":401,"correct":22},{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":20,"analysis":33},1023089,"室内开启式灯具效率不宜低于（）。",[427,429,431,433],{"key":20,"text":428,"correct":26},"70%；",{"key":24,"text":430,"correct":22},"80%；",{"key":28,"text":432,"correct":22},"90%；",{"key":31,"text":434,"correct":22},"50%。",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":31,"analysis":33},1023090,"带格栅灯具的效率不宜低于（）。",[439,440,442,444],{"key":20,"text":428,"correct":22},{"key":24,"text":441,"correct":22},"60%；",{"key":28,"text":443,"correct":22},"55%；",{"key":31,"text":434,"correct":26},{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":28,"analysis":33},1023091,"当灯具安装髙度在6~15m，按光强分布特性选择灯具时，宜选用（）灯具。",[449,451,453,455],{"key":20,"text":450,"correct":22},"宽配光；",{"key":24,"text":452,"correct":22},"余弦配光；",{"key":28,"text":454,"correct":26},"中配光；",{"key":31,"text":456,"correct":22},"窄配光。",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":31,"analysis":33},1023092,"大型仓库光源宜选用（）。",[461,462,463,465],{"key":20,"text":410,"correct":22},{"key":24,"text":395,"correct":22},{"key":28,"text":464,"correct":22},"卤钨灯；",{"key":31,"text":466,"correct":26},"高强气体放电灯。",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":20,"analysis":33},1023093,"配照型照明灯具均匀布置时，L\u002FH值为（）。",[471,473,475,477],{"key":20,"text":472,"correct":26},"0.88~1.41；",{"key":24,"text":474,"correct":22},"1.28~1.38；",{"key":28,"text":476,"correct":22},"1.45~1.75；",{"key":31,"text":478,"correct":22},"0.77~0.88。",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":28,"analysis":33},1023094,"由专门支路供电的插座回路，插座数量宜为（）个。",[483,485,487,489],{"key":20,"text":484,"correct":22},"5~10；",{"key":24,"text":486,"correct":22},"10~15；",{"key":28,"text":488,"correct":26},"15~20；",{"key":31,"text":490,"correct":22},"20~25。",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":20,"analysis":33},1023095,"障碍标志灯宜采用（）控制。",[495,497,499,501],{"key":20,"text":496,"correct":26},"光电自动；",{"key":24,"text":498,"correct":22},"空气断路器；",{"key":28,"text":500,"correct":22},"手动；",{"key":31,"text":502,"correct":22},"接触器远方。",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":20,"analysis":33},1023096,"建筑物内部的灯具引入线，应采用多股铜芯软线，其截面不应小于（）mm2。",[507,509,511,513],{"key":20,"text":508,"correct":26},"0.5；",{"key":24,"text":510,"correct":22},"1；",{"key":28,"text":512,"correct":22},"1.5；",{"key":31,"text":514,"correct":22},"2.5。",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":28,"analysis":33},1023097,"照明开关的安装高度，除拉线开关外，宜为（）m。",[519,520,522,524],{"key":20,"text":512,"correct":22},{"key":24,"text":521,"correct":22},"1.4；",{"key":28,"text":523,"correct":26},"1.3,",{"key":31,"text":525,"correct":22},"1.2。",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":31,"analysis":33},1023098,"汽机房运转层工作面平均照度标准值：混合照明为（）lx，混合照明中的一般照明为（）lx。",[530,532,534,536],{"key":20,"text":531,"correct":22},"500,200；",{"key":24,"text":533,"correct":22},"400,100；",{"key":28,"text":535,"correct":22},"400,200；",{"key":31,"text":537,"correct":26},"500，100,",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":28,"analysis":33},1023099,"计算机工作面上的平均照度标准值：一般照明（）lx,事故照明（ ）lx。",[542,544,546,548],{"key":20,"text":543,"correct":22},"100.10；",{"key":24,"text":545,"correct":22},"100,20；",{"key":28,"text":547,"correct":26},"200，20；",{"key":31,"text":549,"correct":22},"300，20。",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":28,"analysis":33},1023100,"在经常有人工作的车间，采用高强气体放电灯作为一般照明时，其照度值不宜低于（）lx。",[554,556,558,560],{"key":20,"text":555,"correct":22},"100；",{"key":24,"text":557,"correct":22},"80；",{"key":28,"text":559,"correct":26},"50；",{"key":31,"text":561,"correct":22},"70。",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":31,"analysis":33},1023101,"主要通道上疏散照明的照度值，不应低于（）lx。",[566,567,569,571],{"key":20,"text":510,"correct":22},{"key":24,"text":568,"correct":22},"2；",{"key":28,"text":570,"correct":22},"3；",{"key":31,"text":572,"correct":26},"0.5。",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":20,"analysis":33},1023102,"投光灯的轴线光强为19200cd，该投光灯最小允许安装高度为（）m。",[577,579,581,583],{"key":20,"text":578,"correct":26},"8；",{"key":24,"text":580,"correct":22},"7；",{"key":28,"text":582,"correct":22},"9；",{"key":31,"text":584,"correct":22},"10。",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":20,"analysis":33},1023103,"某控制室面积为320m2，单位容量为25~50W\u002Fm2，采用2X40W的铝合金栅格荧光灯具，该控制室安装灯具的数量范围是（）。",[589,591,593,595],{"key":20,"text":590,"correct":26},"100≤N≤200；",{"key":24,"text":592,"correct":22},"200≤N；",{"key":28,"text":594,"correct":22},"N≥100；",{"key":31,"text":596,"correct":22},"200≤N≤400。",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":31,"analysis":33},1023104,"在一个工作场所内不应只采用（ ）。",[601,603,605,607],{"key":20,"text":602,"correct":22},"—般照明；",{"key":24,"text":604,"correct":22},"分区一般照明；",{"key":28,"text":606,"correct":22},"涨合照明；",{"key":31,"text":608,"correct":26},"局部照明。",[610,613,616,619,622,625],{"id":15,"name":611,"category":7,"favorite":612},"领导干部任职前廉政法规知识测试题",92,{"id":614,"name":615,"category":7,"favorite":15},595,"建筑结构与设备",{"id":617,"name":618,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":620,"name":621,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":623,"name":624,"category":7,"favorite":8},534,"BIM工程师",{"id":626,"name":624,"category":7,"favorite":8},535]