[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":569},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,2,50,2670,[13,34,46,58,66,77,89,101,109,121,133,143,151,159,170,180,188,197,207,216,224,232,242,250,262,274,286,298,310,322,334,346,358,370,382,394,406,418,430,442,454,466,478,490,502,510,522,534,546,558],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},1021799,1,"单选题","一台15MVA双绕组高压厂用变压器，短路阻抗在制造上的误差为+5%和一10%,短路阻抗电压为10.5%,取基准容量Sj=1OOMVA,已知发电机出口电压为20kV,发电机出口三相短路电流周期分量的起始值为120k A，参加反馈的6kV电动机额定功率为18000kW,电动机的平均反馈电流倍数为6，髙压电动机的平均ηcosψ取0.8。 发电机出口的短路容量为（）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","4156.9MVA；",false,{"key":24,"text":25,"correct":22},"B","4572.6MVA；",{"key":27,"text":28,"correct":29},"C","4364.8MVA；",true,{"key":31,"text":32,"correct":22},"D","3949.1MVA。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},1021800,"一台15MVA双绕组高压厂用变压器，短路阻抗在制造上的误差为+5%和一10%,短路阻抗电压为10.5%,取基准容量Sj=1OOMVA,已知发电机出口电压为20kV,发电机出口三相短路电流周期分量的起始值为120k A，参加反馈的6kV电动机额定功率为18000kW,电动机的平均反馈电流倍数为6，髙压电动机的平均ηcosψ取0.8。 变压器电抗标么值为（ ）。 高压厂用母线三相短路电流周期分量的起始值为（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":29},"27kA,",{"key":24,"text":41,"correct":22},"25.7kA；",{"key":27,"text":43,"correct":22},"24.6kA；",{"key":31,"text":45,"correct":22},"14.03kA。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},1021801,"一台三绕组变压器绕组间的短路电压的百分值分别为，U dI.II=9.92%，U dI.III=15.9%,U dII.III=5.8%。 髙压绕组的短路电压为（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":29},"10.01%；",{"key":24,"text":53,"correct":22},"-0.09%；",{"key":27,"text":55,"correct":22},"5.89%；",{"key":31,"text":57,"correct":22},"12.19%。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},1021802,"一台三绕组变压器绕组间的短路电压的百分值分别为，U dI.II=9.92%，U dI.III=15.9%,U dII.III=5.8%。 中压绕组的短路电压为（）。",[62,63,64,65],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":29},{"key":27,"text":55,"correct":22},{"key":31,"text":57,"correct":22},{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":27,"analysis":33},1021803,"一台三绕组变压器绕组间的短路电压的百分值分别为，U dI.II=9.92%，U dI.III=15.9%,U dII.III=5.8%。 低压绕组的短路电压为（）.",[70,71,73,75],{"key":20,"text":51,"correct":22},{"key":24,"text":72,"correct":22},"—0.09%；",{"key":27,"text":74,"correct":29},"5.89%,",{"key":31,"text":76,"correct":22},"12.19%.",{"id":78,"libraryId":5,"type":15,"typeLabel":16,"stem":79,"options":80,"answer":20,"analysis":33},1021805,"一台分裂变压器，容量为40\u002F20~20MV A，已知半穿越阻抗X 1-2'为15%,分裂系数（Kf）为3.5，基准容量为1000MV A. 髙压绕组与总的低压绕组间的穿越电抗为（ ）。",[81,83,85,87],{"key":20,"text":82,"correct":29},"0.30；",{"key":24,"text":84,"correct":22},"0.15；",{"key":27,"text":86,"correct":22},"0.08；",{"key":31,"text":88,"correct":22},"0.075.",{"id":90,"libraryId":5,"type":15,"typeLabel":16,"stem":91,"options":92,"answer":24,"analysis":33},1021806,"一台分裂变压器，容量为40\u002F20~20MV A，已知半穿越阻抗X 1-2'为15%,分裂系数（Kf）为3.5，基准容量为1000MV A.",[93,95,97,99],{"key":20,"text":94,"correct":22},"分裂绕组的电抗标么值X2'为（）。",{"key":24,"text":96,"correct":29},"13.13；",{"key":27,"text":98,"correct":22},"3.5； C3.28；",{"key":31,"text":100,"correct":22},"6.56。",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":20,"analysis":33},1021807,"220kV线路（见图5-13）K点A相单相接地短路。电源、线路阻抗标么值已在图中注明，额定电压为220kV,基准容量为1000MVA。 图5-14中K点A相接地短路时复合序网图正确的是（）。",[105,106,107,108],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":110,"libraryId":5,"type":15,"typeLabel":16,"stem":111,"options":112,"answer":24,"analysis":33},1021808,"220kV线路（见图5-13）K点A相单相接地短路。电源、线路阻抗标么值已在图中注明，额定电压为220kV,基准容量为1000MVA。 短路点的正序短路电流的合成阻抗（标么值）为（）。",[113,115,117,119],{"key":20,"text":114,"correct":22},"1.25；",{"key":24,"text":116,"correct":29},"2.76；",{"key":27,"text":118,"correct":22},"0.6；",{"key":31,"text":120,"correct":22},"1.05。",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":31,"analysis":33},1021809,"220kV线路（见图5-13）K点A相单相接地短路。电源、线路阻抗标么值已在图中注明，额定电压为220kV,基准容量为1000MVA。 短路点的正序短路电流（有名值）为（ ）。",[125,127,129,131],{"key":20,"text":126,"correct":22},"2.O1kA5",{"key":24,"text":128,"correct":22},"2.39kA;",{"key":27,"text":130,"correct":22},"4.18kA；",{"key":31,"text":132,"correct":29},"0.91kA,",{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":27,"analysis":33},1021810,"220kV线路（见图5-13）K点A相单相接地短路。电源、线路阻抗标么值已在图中注明，额定电压为220kV,基准容量为1000MVA。 短路点的单相短路电流（有名值）为（）。 A.3.48kA；",[137,139,141],{"key":20,"text":138,"correct":22},"3.68kA；",{"key":24,"text":140,"correct":22},"2.73kA；",{"key":27,"text":142,"correct":29},"4.18k",{"id":144,"libraryId":5,"type":15,"typeLabel":16,"stem":145,"options":146,"answer":24,"analysis":33},1021811,"220kV线路（见图5-15）K点发生相间短路，电源、线路阻抗标么值已在图中注明，额定电压为220kV，基准容量为1000MVA。 图5-16中K点相间短路时复合序网图正确的是（ ）。",[147,148,149,150],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":20,"analysis":33},1021812,"220kV线路（见图5-15）K点发生相间短路，电源、线路阻抗标么值已在图中注明，额定电压为220kV，基准容量为1000MVA。 短路点的正序短路电流的合成电抗（标么值）为（）。",[155,156,157,158],{"key":20,"text":114,"correct":29},{"key":24,"text":116,"correct":22},{"key":27,"text":118,"correct":22},{"key":31,"text":120,"correct":22},{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":20,"analysis":33},1021813,"220kV线路（见图5-15）K点发生相间短路，电源、线路阻抗标么值已在图中注明，额定电压为220kV，基准容量为1000MVA。 短路点的正序短路电流（有名值）为（）。",[163,165,167,168],{"key":20,"text":164,"correct":29},"2.OlkA5",{"key":24,"text":166,"correct":22},"2.39kA；",{"key":27,"text":130,"correct":22},{"key":31,"text":169,"correct":22},"0.91kA?",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":20,"analysis":33},1021814,"220kV线路（见图5-15）K点发生相间短路，电源、线路阻抗标么值已在图中注明，额定电压为220kV，基准容量为1000MVA。 短路点的两相短路电流（有名值）为（）。",[174,176,177,178],{"key":20,"text":175,"correct":29},"3.48kA；",{"key":24,"text":138,"correct":22},{"key":27,"text":140,"correct":22},{"key":31,"text":179,"correct":22},"4.18kA,",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":31,"analysis":33},1021815,"220kV线路（见图5-17）K点发生两相接地短路。电源、线路阻抗标么值已在图中注明，额定电压为220kV，基准容量为1OOOMVA。 图5-18是K点两相接地短路时复合序网图，正确的是（）。",[184,185,186,187],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":31,"analysis":33},1021816,"220kV线路（见图5-17）K点发生两相接地短路。电源、线路阻抗标么值已在图中注明，额定电压为220kV，基准容量为1OOOMVA。 短路点的正序短路电流的合成电抗（标么值）为（）。",[192,194,195,196],{"key":20,"text":193,"correct":22},"1.25,",{"key":24,"text":116,"correct":22},{"key":27,"text":118,"correct":22},{"key":31,"text":120,"correct":29},{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":24,"analysis":33},1021817,"220kV线路（见图5-17）K点发生两相接地短路。电源、线路阻抗标么值已在图中注明，额定电压为220kV，基准容量为1OOOMVA。 短路点的正序短路电流（有名值）为（）。",[201,203,204,205],{"key":20,"text":202,"correct":22},"2.O1kA;",{"key":24,"text":166,"correct":29},{"key":27,"text":130,"correct":22},{"key":31,"text":206,"correct":22},"0.91kA。",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":24,"analysis":33},1021818,"220kV线路（见图5-17）K点发生两相接地短路。电源、线路阻抗标么值已在图中注明，额定电压为220kV，基准容量为1OOOMVA。 短路点的两相接地短路电流（有名值)为（）。",[211,212,213,214],{"key":20,"text":175,"correct":22},{"key":24,"text":138,"correct":29},{"key":27,"text":140,"correct":22},{"key":31,"text":215,"correct":22},"4.18kA。",{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":27,"analysis":33},1021819,"220kV线路（如图5-19所示）K点发生三相短路。电源、线路电抗标么值已注明在图中，额定电压为220kV，基准容量为1000MVA。 图5-20是K点三相短路时复合序网图，正确的是（）。",[220,221,222,223],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":27,"analysis":33},1021820,"220kV线路（如图5-19所示）K点发生三相短路。电源、线路电抗标么值已注明在图中，额定电压为220kV，基准容量为1000MVA。 短路点的正序短路电流的合成电抗（标么值）为（）。",[228,229,230,231],{"key":20,"text":114,"correct":22},{"key":24,"text":116,"correct":22},{"key":27,"text":118,"correct":29},{"key":31,"text":120,"correct":22},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":31,"analysis":33},1021821,"220kV线路（如图5-19所示）K点发生三相短路。电源、线路电抗标么值已注明在图中，额定电压为220kV，基准容量为1000MVA。 短路点的正序短路电流（有名值）为（）。",[236,238,239,241],{"key":20,"text":237,"correct":22},"2.01kA；",{"key":24,"text":166,"correct":22},{"key":27,"text":240,"correct":22},"0.91kA；",{"key":31,"text":215,"correct":29},{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":31,"analysis":33},1021822,"220kV线路（如图5-19所示）K点发生三相短路。电源、线路电抗标么值已注明在图中，额定电压为220kV，基准容量为1000MVA。 短路点的三相短路电流（有名值）为（）。",[246,247,248,249],{"key":20,"text":175,"correct":22},{"key":24,"text":138,"correct":22},{"key":27,"text":140,"correct":22},{"key":31,"text":215,"correct":29},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":27,"analysis":33},1021823,"短路电流计算其基本参数，系统阻抗应考虑工程建成后（）。",[254,256,258,260],{"key":20,"text":255,"correct":22},"5年；",{"key":24,"text":257,"correct":22},"10年；",{"key":27,"text":259,"correct":29},"5~10年；",{"key":31,"text":261,"correct":22},"10~15年。",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":27,"analysis":33},1021824,"短路电流计算按系统内（）",[266,268,270,272],{"key":20,"text":267,"correct":22},"正常运行方式；",{"key":24,"text":269,"correct":22},"最小运行方式；",{"key":27,"text":271,"correct":29},"最大运行方式；",{"key":31,"text":273,"correct":22},"满足负荷运行方式，",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":24,"analysis":33},1021825,"短路电流计算中，常出现多支路星形网络，对多支路星形网络的化简方法常用",[278,280,282,284],{"key":20,"text":279,"correct":22},"分布系数法；",{"key":24,"text":281,"correct":29},"ΣY法；",{"key":27,"text":283,"correct":22},"电流反比分配法；",{"key":31,"text":285,"correct":22},"平均值法。",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":24,"analysis":33},1021826,"短路电流计算是假定在正常运行下电网内的三相系统（）。",[290,292,294,296],{"key":20,"text":291,"correct":22},"随机不对称运行；",{"key":24,"text":293,"correct":29},"三相对称运行；",{"key":27,"text":295,"correct":22},"大部分对称运行；",{"key":31,"text":297,"correct":22},"由电网参数决定，",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":20,"analysis":33},1021827,"短路电流计算中，假定电网内机组（）。",[302,304,306,308],{"key":20,"text":303,"correct":29},"同步运行；",{"key":24,"text":305,"correct":22},"部分不同步运行；",{"key":27,"text":307,"correct":22},"随机运行；",{"key":31,"text":309,"correct":22},"没有假定。",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":24,"analysis":33},1021828,"短路电流计算中，假定所有同步电机均（）。",[314,316,318,320],{"key":20,"text":315,"correct":22},"不设自动助磁装置；",{"key":24,"text":317,"correct":29},"设自动励磁装置；",{"key":27,"text":319,"correct":22},"发电机设自动励磁装里；",{"key":31,"text":321,"correct":22},"电动机可不设自动励磁装里。",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":27,"analysis":33},1021829,"短路电流计算中，假定同步电机的运行状态为（）。",[326,328,330,332],{"key":20,"text":327,"correct":22},"过励磁运行；",{"key":24,"text":329,"correct":22},"欠励磁运行；",{"key":27,"text":331,"correct":29},"額定功率因数运行；",{"key":31,"text":333,"correct":22},"未作规定。",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":27,"analysis":33},1021830,"在短路电流计算中，平均电压与额定电压的关系是（）。",[338,340,342,344],{"key":20,"text":339,"correct":22},"1倍；",{"key":24,"text":341,"correct":22},"1.1倍；",{"key":27,"text":343,"correct":29},"1.05倍；",{"key":31,"text":345,"correct":22},"1.2倍。",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":24,"analysis":33},1021831,"短路电流全电流最大有效值Ich，在计算中可以不考虑周期分量衰减，但在利用Kch冲击系数表时（）。",[350,352,354,356],{"key":20,"text":351,"correct":22},"不考虑周期分量衰减；",{"key":24,"text":353,"correct":29},"已考虑周期分量衰减；",{"key":27,"text":355,"correct":22},"远离发电机端部未考虑衰减",{"key":31,"text":357,"correct":22},"发电机端考虑衰减。",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":24,"analysis":33},1021832,"有限电源供给短路电流，当实际发电设备与运算曲线性能有较大差距时，需要修正的情况为（）。",[362,364,366,368],{"key":20,"text":363,"correct":22},"误差为2%；",{"key":24,"text":365,"correct":29},"误差为5%；",{"key":27,"text":367,"correct":22},"误差为4%；",{"key":31,"text":369,"correct":22},"误差为8%。",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":27,"analysis":33},1021833,"有限电源供给短路电流，一般发电机的强励顶值倍数在制定运行曲线时取1.8倍，当机组励磁方式有较大差距时应考虑修正（）。",[374,376,378,380],{"key":20,"text":375,"correct":22},"1.5倍以上；",{"key":24,"text":377,"correct":22},"1.8倍以上；",{"key":27,"text":379,"correct":29},"2倍以上；",{"key":31,"text":381,"correct":22},"2.2倍以上。",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":31,"analysis":33},1021834,"短路电流的热效应偉应包括两个部分，一是由周期分量短路电流，二是由非周期分量短路电流的和组成，但在实际设计中由于非周期分量较小而忽略，如（）。",[386,388,390,392],{"key":20,"text":387,"correct":22},"发电机出口；",{"key":24,"text":389,"correct":22},"发电机母线；",{"key":27,"text":391,"correct":22},"发电机电抗器后；",{"key":31,"text":393,"correct":29},"变电所母线及进出线。",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":27,"analysis":33},1021835,"在不对称短路电流计算中，计算不对称的冲击电流时，对异步电机的反馈电流（）。",[398,400,402,404],{"key":20,"text":399,"correct":22},"要考虑；",{"key":24,"text":401,"correct":22},"依距离远近适当考虑；",{"key":27,"text":403,"correct":29},"不考虑；",{"key":31,"text":405,"correct":22},"一般情况不考虑。",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":27,"analysis":33},1021836,"低压短路电流计算与高压短路电流计算的显著不同是（）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"考虑电容；",{"key":24,"text":413,"correct":22},"忽略电阻；",{"key":27,"text":415,"correct":29},"计入电阻；",{"key":31,"text":417,"correct":22},"计入电容。",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":24,"analysis":33},1021837,"低压厂用电中央配电盘，计算其短路电流时，仍需考虑电动机反馈。在工程设计中为简化计算，对于反馈的电动机容量一般考虑为变压器容量的（）。",[422,424,426,428],{"key":20,"text":423,"correct":22},"50%；",{"key":24,"text":425,"correct":29},"60%；",{"key":27,"text":427,"correct":22},"65%；",{"key":31,"text":429,"correct":22},"55%。",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":24,"analysis":33},1021838,"低压短路电流计算时，一般对较短的电缆可不计及电阻，其长度为（）。",[434,436,438,440],{"key":20,"text":435,"correct":22},"5~1Om以下；",{"key":24,"text":437,"correct":29},"1Om以下；",{"key":27,"text":439,"correct":22},"10~15m以下；",{"key":31,"text":441,"correct":22},"5m以下。",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":27,"analysis":33},1021839,"低压短路电流的简便计算方法为（）。",[446,448,450,452],{"key":20,"text":447,"correct":22},"标么值法；",{"key":24,"text":449,"correct":22},"标么值和有名值结合；",{"key":27,"text":451,"correct":29},"有名值法；",{"key":31,"text":453,"correct":22},"有名值为主，标么值为辅。",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":24,"analysis":33},1021840,"校验动稳定时，电动力一般用（ ）。",[458,460,462,464],{"key":20,"text":459,"correct":22},"两相短路；",{"key":24,"text":461,"correct":29},"三相短路；",{"key":27,"text":463,"correct":22},"单相接地短路；",{"key":31,"text":465,"correct":22},"两相接地.",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":24,"analysis":33},1021841,"采用低压侧带分裂绕组的变压器是限制短路电流方法之一，常用于（）。",[470,472,474,476],{"key":20,"text":471,"correct":22},"小型火力发电厂；",{"key":24,"text":473,"correct":29},"大型火力发电厂;",{"key":27,"text":475,"correct":22},"中型火力发电厂；",{"key":31,"text":477,"correct":22},"大型超高压变电所。",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":27,"analysis":33},1021842,"校验热效应与断路器的开断时间有密切关系，当采用一般低速断路器，其合分闸时间大于0.12s,此时计算热效应时间为（）。",[482,484,486,488],{"key":20,"text":483,"correct":22},"0.1s；",{"key":24,"text":485,"correct":22},"0.15s；",{"key":27,"text":487,"correct":29},"0.2s；",{"key":31,"text":489,"correct":22},"0.25s?",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":27,"analysis":33},1021843,"当电源系统为无限大，且计算电抗Xjs≥3时，一般可认为（）。",[494,496,498,500],{"key":20,"text":495,"correct":22},"短路电流衰减；",{"key":24,"text":497,"correct":22},"随远近而衰减；",{"key":27,"text":499,"correct":29},"周期分量起始值不衰减；",{"key":31,"text":501,"correct":22},"冲击电流衰减，",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":24,"analysis":33},1021844,"有限电源供给的短路电流是计算Xjs后査有关曲线和数据表，这些表和曲线是我国近年来的研究成果，比过去沿用前苏联曲线大（）。 A.5%; B.5%~10%；C5%~8%； D.10%。",[506,507,508,509],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":29},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":24,"analysis":33},1021845,"限制短路电流是设计中应予关注的事，其方法有多种，但在发电厂、变电所中最简单有效的是（）。",[514,516,518,520],{"key":20,"text":515,"correct":22},"并列运行；",{"key":24,"text":517,"correct":29},"分裂运行；",{"key":27,"text":519,"correct":22},"短时并列运行；",{"key":31,"text":521,"correct":22},"从远处并列。",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":31,"analysis":33},1021846,"不对称短路电流计算一般用于单相或两相短路电流大于三相短路电流时，校验其选用设备，如（）。",[526,528,530,532],{"key":20,"text":527,"correct":22},"变压器回路；",{"key":24,"text":529,"correct":22},"出线回路；",{"key":27,"text":531,"correct":22},"发电机出口回路；",{"key":31,"text":533,"correct":29},"母联回路和母线分段回路。",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":20,"analysis":33},1021847,"短路电流计算中对有铁心的电器设备（）。",[538,540,542,544],{"key":20,"text":539,"correct":29},"不考虑饱和；",{"key":24,"text":541,"correct":22},"电机考虑不饱和；",{"key":27,"text":543,"correct":22},"变压器考虑不饱和；",{"key":31,"text":545,"correct":22},"考虑饱和。",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":27,"analysis":33},1021848,"图 5-1为（）。",[550,552,554,556],{"key":20,"text":551,"correct":22},"单相短路电流相量图；",{"key":24,"text":553,"correct":22},"两相接地短路电流相量图；",{"key":27,"text":555,"correct":29},"两相短路电流相量图；",{"key":31,"text":557,"correct":22},"单相接地电流相量图。",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":27,"analysis":33},1021849,"6kV厂用电母线短路电流计算中，电动机的反馈电流周期分量和非周期分量，对其衰减应（）。",[562,564,565,567],{"key":20,"text":563,"correct":22},"分别考虑；",{"key":24,"text":403,"correct":22},{"key":27,"text":566,"correct":29},"按相同时间常数考虑；",{"key":31,"text":568,"correct":22},"随具体情况确定。",[570,573,576,579,582,585],{"id":15,"name":571,"category":7,"favorite":572},"领导干部任职前廉政法规知识测试题",92,{"id":574,"name":575,"category":7,"favorite":15},595,"建筑结构与设备",{"id":577,"name":578,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":580,"name":581,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":583,"name":584,"category":7,"favorite":8},534,"BIM工程师",{"id":586,"name":584,"category":7,"favorite":8},535]