[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-19":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":620},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,19,50,2670,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,310,322,334,346,358,370,382,394,406,418,430,442,454,466,478,490,502,514,526,538,550,562,572,584,596,608],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1022654,1,"单选题","微机继电保护装置用于旁路保护或其他定值经常需要改变的情况时，宜设置多套切换的定值，一般不少于（）定值。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","5套；",false,{"key":24,"text":25,"correct":22},"B","6套；",{"key":27,"text":28,"correct":22},"C","7套；",{"key":30,"text":31,"correct":32},"D","8套。",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},1022655,"电力系统安全稳定控制技术中，（）不属于紧急控制的手段。",[38,40,42,44],{"key":20,"text":39,"correct":32},"发电机励磁附加控制；",{"key":24,"text":41,"correct":22},"发电端切除发电机控制；",{"key":27,"text":43,"correct":22},"负荷端集中切负荷控制； ‘",{"key":30,"text":45,"correct":22},"预先选定的输电断面进行解列。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1022656,"电力系统由于小扰动产生的低频振荡，振荡频率一般为（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"0~0.2Hz；",{"key":24,"text":53,"correct":32},"O.2~2.5Hz；",{"key":27,"text":55,"correct":22},"5~10Hz；",{"key":30,"text":57,"correct":22},"10~20Hz。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},1022657,"安全稳定控制系统中，采用数字式远方传送命令信息设备来传送允许式（有就地启动判据）命令，其传瑜时间要求不大于（）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"5ms",{"key":24,"text":65,"correct":22},"8ms；",{"key":27,"text":67,"correct":32},"10ms；",{"key":30,"text":69,"correct":22},"12ms。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":30,"analysis":33},1022658,"安全稳定控制系统中，采用模拟式远方传送命令信息设备来传送直跳式（无就地启动判据）命令，其传输时间要求不大于（）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"20ms；",{"key":24,"text":77,"correct":22},"25ms；",{"key":27,"text":79,"correct":22},"30msj",{"key":30,"text":81,"correct":32},"40ms。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},1022659,"电网调度自动化有四大基本功能，分别是（）。 A. SCADA,AGC\u002FED C、PAS、DTS； B. SCADA,AG C、PAS、DTS5",[86,88,90,92],{"key":20,"text":87,"correct":32},"遥测、遥信、遥控、遥调（四遥），AGC\u002FEDC,负荷預测，DCS；",{"key":24,"text":89,"correct":22},"9CAD",{"key":27,"text":91,"correct":22},"PAS、AG",{"key":30,"text":93,"correct":22},"EDC。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},1022660,"能量管理系统通常的表示方式为（），",[98,100,102,104],{"key":20,"text":99,"correct":22},"9CADA\u002FAGC；",{"key":24,"text":101,"correct":32},"SCADA\u002FEMS；",{"key":27,"text":103,"correct":22},"AGC\u002FEMS；",{"key":30,"text":105,"correct":22},"SCADA\u002FAGC+EMS。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":30,"analysis":33},1022661,"我国规定，3000MW及以上装机容量的电网及跨省电网的频率偏差分别控制在（）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"±0.5Hz,±0.2Hz；",{"key":24,"text":113,"correct":22},"±0.2Hz,±0.5Hz；",{"key":27,"text":115,"correct":22},"±0.2Hz，±0.2Hz；",{"key":30,"text":117,"correct":32},"±0.2Hz、±0.1Hz。",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":30,"analysis":33},1022662,"在频率自动调整时，为达到无差调节，不可缺少的方式为（）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"比例调节；",{"key":24,"text":125,"correct":22},"微分调节；",{"key":27,"text":127,"correct":22},"比例、积分调节；",{"key":30,"text":129,"correct":32},"积分调节。",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":30,"analysis":33},1022663,"跨大区互联系统联合运行的控制中，最佳的配合方式为（）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"TLBC-CF；",{"key":24,"text":137,"correct":22},"CFC-CNIC；",{"key":27,"text":139,"correct":22},"CNIC-TLBC；",{"key":30,"text":141,"correct":32},"TLBC-TLBC。",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":27,"analysis":33},1022664,"与负荷变化相适应的调整速度一般要求为（）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"火电机组每分钟1.5%，水电机组45%额定容量以上；",{"key":24,"text":149,"correct":22},"火电机組每分钟1%,水电机组40%額定容量以上；",{"key":27,"text":151,"correct":32},"火电机组每分钟2%,水电机组50%額定容量以上；",{"key":30,"text":153,"correct":22},"火电机组每分钟1.75%,水电机组40%額定容量以上。",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":30,"analysis":33},1022665,"PAS功能是()。",[158,160,162,164],{"key":20,"text":159,"correct":22},"EMS的基袖功能；",{"key":24,"text":161,"correct":22},"EMS在发电层的应用功能；",{"key":27,"text":163,"correct":22},"EMS的仿真功能；",{"key":30,"text":165,"correct":32},"EMS在电力系统网络雇的高级应用功能。",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":27,"analysis":33},1022666,"DMS的主要功能是（）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"SCADA\u002FAGC\u002FPAS,",{"key":24,"text":173,"correct":22},"SCADA\u002FAGC\u002FEDC\u002FDTS5",{"key":27,"text":175,"correct":32},"SCADA\u002FLM\u002FPAS\u002F(AM\u002FFM\u002FGIS)；",{"key":30,"text":177,"correct":22},"SCADA\u002FLM\u002FPAS\u002FDTS。",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":27,"analysis":33},1022667,"集成多种复杂应用功能到统一系统当中，关键的问题是()。",[182,184,186,188],{"key":20,"text":183,"correct":22},"计算机硬件平台是否先进；",{"key":24,"text":185,"correct":22},"功能是否全面；",{"key":27,"text":187,"correct":32},"支撑系统是否优劣；",{"key":30,"text":189,"correct":22},"系统规模是否庞大。",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":30,"analysis":33},1022668,"一个具备64个厂站电网规模的SCADA系统处理能力，其实时信息与数据容量规模为（）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"YX：24576，YC：16384，YT：2048，计算量：8192；",{"key":24,"text":197,"correct":22},"YX：32768，YC：16384，YT：4096，计算量：6144；",{"key":27,"text":199,"correct":22},"YX：16384,YC：12288，YT：3072，计算量：4096；",{"key":30,"text":201,"correct":32},"YX：32768，YC：16384，YT：4096，计算量：8192,",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":24,"analysis":33},1022669,"远动终端RTU应配置的地点是（）。",[206,208,210,212],{"key":20,"text":207,"correct":22},"调度中心内；",{"key":24,"text":209,"correct":32},"发电厂和变电所内及配电网相应设施上；",{"key":27,"text":211,"correct":22},"只能配里在岌电厂内；",{"key":30,"text":213,"correct":22},"只能配置在变电所内。",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":27,"analysis":33},1022670,"ERTU具有（）。",[218,220,222,224],{"key":20,"text":219,"correct":22},"遥控功能；",{"key":24,"text":221,"correct":22},"遥调功能；",{"key":27,"text":223,"correct":32},"采集电能向远方传递功能；",{"key":30,"text":225,"correct":22},"事件顺序记录功能。",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":30,"analysis":33},1022671,"分布式RTU的主要特点是（）。",[230,232,234,236],{"key":20,"text":231,"correct":22},"结构简单紧凑；",{"key":24,"text":233,"correct":22},"采用问答式（Polling)和循环式（CDT)；",{"key":27,"text":235,"correct":22},"共用CPU、电源和使用并联芯线；",{"key":30,"text":237,"correct":32},"主机CPU与各功能模板上微处理器各司其职，并通过计算机网络连接，",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":20,"analysis":33},1022672,"问答式远动传输(Polling)向调度端传递信息方式为（）。",[242,244,246,248],{"key":20,"text":243,"correct":32},"调度端询问后才传送；",{"key":24,"text":245,"correct":22},"周期性不断地向调度端传送；",{"key":27,"text":247,"correct":22},"间断地主动向调度端传送；",{"key":30,"text":249,"correct":22},"同步地向调度端传送。",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":27,"analysis":33},1022673,"用架空地线复合光缆（OPGW)作远动通道，通常开通路数为()。",[254,256,258,260],{"key":20,"text":255,"correct":22},"480；",{"key":24,"text":257,"correct":22},"1至多路；",{"key":27,"text":259,"correct":32},"大于120；",{"key":30,"text":261,"correct":22},"120。",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":24,"analysis":33},1022674,"远动电量变送器输出电流优选值是()。",[266,268,270,272],{"key":20,"text":267,"correct":22},"O~20mA；",{"key":24,"text":269,"correct":32},"4~20mA；",{"key":27,"text":271,"correct":22},"-1~0~1mA；",{"key":30,"text":273,"correct":22},"O~10mA。",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":27,"analysis":33},1022675,"()不是电能量计费系统（AMR A)的功能。",[278,280,282,284],{"key":20,"text":279,"correct":22},"电能量数据采集；",{"key":24,"text":281,"correct":22},"电能数提分析；",{"key":27,"text":283,"correct":32},"遥信、遥调；",{"key":30,"text":285,"correct":22},"电能量数据安全保密。",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":27,"analysis":33},1022676,"执行峰谷电价或考核峰谷电量的计量点，应装设（）。",[290,292,294,296],{"key":20,"text":291,"correct":22},"有功电能表；",{"key":24,"text":293,"correct":22},"最大需量有功电能表；",{"key":27,"text":295,"correct":32},"多费率有功电能表；",{"key":30,"text":297,"correct":22},"具有计量分时有功电量，进相和滞相的无功电量的多功能电能表。",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":30,"analysis":33},1022677,"电能关口计量点由（ ）确定。",[302,304,306,308],{"key":20,"text":303,"correct":22},"省级电网；",{"key":24,"text":305,"correct":22},"发电厂、高压用户企业；",{"key":27,"text":307,"correct":22},"地区电网；",{"key":30,"text":309,"correct":32},"上述四方之间协商。",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":20,"analysis":33},1022678,"系统电能计量关口点是（）。",[314,316,318,320],{"key":20,"text":315,"correct":32},"省级电网之间的输电线路电量计量点；",{"key":24,"text":317,"correct":22},"省级电网和地区电网之间的输电线路电量计量点；",{"key":27,"text":319,"correct":22},"发电厂和电网之间的上网电量计量点；",{"key":30,"text":321,"correct":22},"地区电网及其用户之间的高压输配电线路电量计量点。",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":24,"analysis":33},1022679,"要求装设两套主、副电能表的关口计量点是（）。",[326,328,330,332],{"key":20,"text":327,"correct":22},"执行辛谷电价的计量点；",{"key":24,"text":329,"correct":32},"发电厂、省级电网或计量需要所指定的电量计量点；",{"key":27,"text":331,"correct":22},"省级电网内的重要联络线；",{"key":30,"text":333,"correct":22},"发电厂和变电所的出线.",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":27,"analysis":33},1022680,"贸易结算关口计量点，应采用（）。",[338,340,342,344],{"key":20,"text":339,"correct":22},"电子型电能量变送器；",{"key":24,"text":341,"correct":22},"交流采样电测量变送器；",{"key":27,"text":343,"correct":32},"相应功能的电能量计量计费表计；",{"key":30,"text":345,"correct":22},"多费率有功电能表计。",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":30,"analysis":33},1022681,"电能量数据的旁路代由AMRA系统的()完成。",[350,352,354,356],{"key":20,"text":351,"correct":22},"系统数据库服务器；",{"key":24,"text":353,"correct":22},"前里机工作站；",{"key":27,"text":355,"correct":22},"用户工作站；",{"key":30,"text":357,"correct":32},"信息处理工作站，",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":27,"analysis":33},1022682,"远动通道的双工方式可以在（）。",[362,364,366,368],{"key":20,"text":363,"correct":22},"两个方内不同时传送；",{"key":24,"text":365,"correct":22},"—个方向上传送不能反向传送；",{"key":27,"text":367,"correct":32},"两个方向上同时传送；",{"key":30,"text":369,"correct":22},"—个方向上传送可反向传送。",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":24,"analysis":33},1022683,"远动终端的遥调功能是（）。",[374,376,378,380],{"key":20,"text":375,"correct":22},"将发电厂、变电所中各断路器、隔离畀关、主要微机保护与自动装置等状态信息采集传送给诉度中心；",{"key":24,"text":377,"correct":32},"由调度中心对发电厂、变电所电气设备实行远方调节；",{"key":27,"text":379,"correct":22},"由调度中心直接控制远方厂所中的电气设备；",{"key":30,"text":381,"correct":22},"将厂所的某些运行参数采集传送到调度中心。",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":20,"analysis":33},1022684,"SCADA\u002FEMS的主站系统的关键设施，采用主\u002F备运行方式,主要采用()。",[386,388,390,392],{"key":20,"text":387,"correct":32},"热备用；",{"key":24,"text":389,"correct":22},"温备用；",{"key":27,"text":391,"correct":22},"冷备用；",{"key":30,"text":393,"correct":22},"并联运行，均有控制命令输出。",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":30,"analysis":33},1022685,"配电所远方终端简称为（）。",[398,400,402,404],{"key":20,"text":399,"correct":22},"RTU；",{"key":24,"text":401,"correct":22},"FTU；",{"key":27,"text":403,"correct":22},"TTU；",{"key":30,"text":405,"correct":32},"DTU。",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":27,"analysis":33},1022686,"调度自动化设备交流电源供电，按规程规定应采用（）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"一路供电；",{"key":24,"text":413,"correct":22},"两游供电，可来自同一电源点；",{"key":27,"text":415,"correct":32},"两路洪电，来自不同电源点；",{"key":30,"text":417,"correct":22},"三路供电，来自不同电源点。",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":27,"analysis":33},1022687,"按照规程规定，计算机系统同大楼合用接地装置’其接地电阻宜小于（）。",[422,424,426,428],{"key":20,"text":423,"correct":22},"O.1Ω；",{"key":24,"text":425,"correct":22},"0.2Ω；",{"key":27,"text":427,"correct":32},"0.5Ω；",{"key":30,"text":429,"correct":22},"1Ω。",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":24,"analysis":33},1022688,"计算机系统采用不间断电源供电，交流电消失后不间断供电维持时伺应不小于（）。",[434,436,438,440],{"key":20,"text":435,"correct":22},"1h；",{"key":24,"text":437,"correct":32},"2h；",{"key":27,"text":439,"correct":22},"30min；",{"key":30,"text":441,"correct":22},"45min。",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":30,"analysis":33},1022689,"按照现行规程，自动发电控制(AG C)命令发送周期为（）。",[446,448,450,452],{"key":20,"text":447,"correct":22},"2~10s；",{"key":24,"text":449,"correct":22},"3~10s；",{"key":27,"text":451,"correct":22},"5~20s；",{"key":30,"text":453,"correct":32},"4~16s,",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":20,"analysis":33},1022690,"调度自动化主站系统的调度员工作站画面调用响应时间为（）。",[458,460,462,464],{"key":20,"text":459,"correct":32},"85%的画面不大于2s，其他画面不大于3s；",{"key":24,"text":461,"correct":22},"95%的画面不大于3s，其他画面不大于5s；",{"key":27,"text":463,"correct":22},"85%的画面不大于3s,其他画面不大于10s；",{"key":30,"text":465,"correct":22},"90%的画面不大于2s，其他画面不大于5s,",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":30,"analysis":33},1022691,"下列实时性指标中不正确的是（ ）。",[470,472,474,476],{"key":20,"text":471,"correct":22},"遥測侍送时间不大于4s；",{"key":24,"text":473,"correct":22},"遥信变化传送时间不大于3s；",{"key":27,"text":475,"correct":22},"遥控、遥调命令传送时间不大于4s；",{"key":30,"text":477,"correct":32},"画面实时数据刷新周期为3~10s。",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":20,"analysis":33},1022692,"调度自动化主站中央处理器平均负荷率在电力系统正常情况下任意30min内应小于（）.",[482,484,486,488],{"key":20,"text":483,"correct":32},"20%；",{"key":24,"text":485,"correct":22},"35%；",{"key":27,"text":487,"correct":22},"45%；",{"key":30,"text":489,"correct":22},"30%。",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":20,"analysis":33},1022693,"对于汽轮发电机定子过电压保护，请回答下列问题。",[494,496,498,500],{"key":20,"text":495,"correct":32},"定子过电压保护的动作时限取值为（）。",{"key":24,"text":497,"correct":22},"0.5s；",{"key":27,"text":499,"correct":22},"1.Os； C1.5s；",{"key":30,"text":501,"correct":22},"2.Os。",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":27,"analysis":33},1022694,"对于汽轮发电机定子过电压保护，请回答下列问题。 定子过电压保护动作于（）。",[506,508,510,512],{"key":20,"text":507,"correct":22},"信号；",{"key":24,"text":509,"correct":22},"解列;",{"key":27,"text":511,"correct":32},"解列灭磁或程序跳闸；",{"key":30,"text":513,"correct":22},"停机。",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":20,"analysis":33},1022695,"某工程4台600MW发电机变压器组’主变压器髙压侧差动保护用TA变比为2000\u002F1 A，TPY。主变压器高压侧TV—次电压为500\u002F√3kV，二次星形电压为0.1\u002F√3kV和二次开口三角电压100V，主变压器容量为3X240MV A，主变压器变比为 550\u002F√3-2X2.5%\u002F22kV,Ud=14%,YNdll,主变压器低压侧差动保护TA变比为16000\u002F1A,TPY0主变压器高压侧三相短路时，短路点系统侧电流27.5kA’发电机侧短路电流为9.882A,主变压器低压侧三相短路时，系统侧短路电流为93.7kA,本台发电机短路电流为105.3k A，其他发电机短路电流为25.6kA。变压器差动保护采用比率制动型，请根据上述已知条件回答下列问题 差动保护用T A，正确的接线形式是（）。 A.高压側TA 二次接线应为三角形，低压侧接线应为星形；高压侧差动回路二次額定电流0.72A,低压侧为1.18A；",[518,520,522,524],{"key":20,"text":519,"correct":32},"高压侧TA二次接线应为星形，低压例接线应为三角形；高压侧差动回路二走額定电流0.72A,低压側为1.18A；",{"key":24,"text":521,"correct":22},"高压侧TA二次接线应为三角形，低压侧接线应为星形；高压侧差动回路二次額定电流0.42",{"key":27,"text":523,"correct":22},"低压侧为2.04A；",{"key":30,"text":525,"correct":22},"高压侧TA二次接线应为星形，低压例接线应为三角形；高压侧差动田路二次額定电流0.42A,低压側为2.04A。",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":27,"analysis":33},1022696,"某工程4台600MW发电机变压器组’主变压器髙压侧差动保护用TA变比为2000\u002F1 A，TPY。主变压器高压侧TV—次电压为500\u002F√3kV，二次星形电压为0.1\u002F√3kV和二次开口三角电压100V，主变压器容量为3X240MV A，主变压器变比为550\u002F√3-X2.5%\u002F22kV,Ud=14%,YNdll,主变压器低压侧差动保护TA变比为16000\u002F1A,TPY0主变压器高压侧三相短路时，短路点系统侧电流27.5kA’发电机侧短路电流为9.882A,主变压器低压侧三相短路时，系统侧短路电流为93.7kA,本台发电机短路电流为105.3k A，其他发电机短路电流为25.6kA。变压器差动保护采用比率制动型，请根据上述已知条件回答下列问题 比率制动型差动保护最小动作电流取差动回路额定电流的0.3倍，则实际计算值为()(以主变压器低压侧为基准，高压侧配置中间电流互感器)。",[530,532,534,536],{"key":20,"text":531,"correct":22},"0.126A;",{"key":24,"text":533,"correct":22},"0.216A;",{"key":27,"text":535,"correct":32},"0.354A；",{"key":30,"text":537,"correct":22},"0.615A。",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":27,"analysis":33},1022697,"某工程4台600MW发电机变压器组’主变压器髙压侧差动保护用TA变比为2000\u002F1 A，TPY。主变压器高压侧TV—次电压为500\u002F√3kV，二次星形电压为0.1\u002F√3kV和二次开口三角电压100V，主变压器容量为3X240MV A，主变压器变比为550\u002F√3-X2.5%\u002F22kV,Ud=14%,YNdll,主变压器低压侧差动保护TA变比为16000\u002F1A,TPY0主变压器高压侧三相短路时，短路点系统侧电流27.5kA’发电机侧短路电流为9.882A,主变压器低压侧三相短路时，系统侧短路电流为93.7kA,本台发电机短路电流为105.3k A，其他发电机短路电流为25.6kA。变压器差动保护采用比率制动型，请根据上述已知条件回答下列问题 比率制动型差动保护最小制动电流取差动回路额定电流的1.0倍，实际计算值为（）。",[542,544,546,548],{"key":20,"text":543,"correct":22},"0.42A；",{"key":24,"text":545,"correct":22},"0.72A；",{"key":27,"text":547,"correct":32},"1.18A；",{"key":30,"text":549,"correct":22},"2.05A。",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":24,"analysis":33},1022698,"某工程4台600MW发电机变压器组’主变压器髙压侧差动保护用TA变比为2000\u002F1 A，TPY。主变压器高压侧TV—次电压为500\u002F√3kV，二次星形电压为0.1\u002F√3kV和二次开口三角电压100V，主变压器容量为3X240MV A，主变压器变比为550\u002F√3-X2.5%\u002F22kV,Ud=14%,YNdll,主变压器低压侧差动保护TA变比为16000\u002F1A,TPY0主变压器高压侧三相短路时，短路点系统侧电流27.5kA’发电机侧短路电流为9.882A,主变压器低压侧三相短路时，系统侧短路电流为93.7kA,本台发电机短路电流为105.3k A，其他发电机短路电流为25.6kA。变压器差动保护采用比率制动型，请根据上述已知条件回答下列问题",[554,556,558,560],{"key":20,"text":555,"correct":22},"比率制动型差动保护最大动作电流为（）。",{"key":24,"text":557,"correct":32},"1.97A；",{"key":27,"text":559,"correct":22},"2.23A；C6.58A；",{"key":30,"text":561,"correct":22},"7.44A。",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":30,"analysis":33},1022699,"某工程4台600MW发电机变压器组’主变压器髙压侧差动保护用TA变比为2000\u002F1 A，TPY。主变压器高压侧TV—次电压为500\u002F√3kV，二次星形电压为0.1\u002F√3kV和二次开口三角电压100V，主变压器容量为3X240MV A，主变压器变比为550\u002F√3-X2.5%\u002F22kV,Ud=14%,YNdll,主变压器低压侧差动保护TA变比为16000\u002F1A,TPY0主变压器高压侧三相短路时，短路点系统侧电流27.5kA’发电机侧短路电流为9.882A,主变压器低压侧三相短路时，系统侧短路电流为93.7kA,本台发电机短路电流为105.3k A，其他发电机短路电流为25.6kA。变压器差动保护采用比率制动型，请根据上述已知条件回答下列问题 比率制动型差动保护最大制动电流为（）。",[566,567,569,571],{"key":20,"text":557,"correct":22},{"key":24,"text":568,"correct":22},"2.23A1",{"key":27,"text":570,"correct":22},"6.58A；",{"key":30,"text":561,"correct":32},{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":27,"analysis":33},1022700,"某工程4台600MW发电机变压器组’主变压器髙压侧差动保护用TA变比为2000\u002F1 A，TPY。主变压器高压侧TV—次电压为500\u002F√3kV，二次星形电压为0.1\u002F√3kV和二次开口三角电压100V，主变压器容量为3X240MV A，主变压器变比为550\u002F√3-X2.5%\u002F22kV,Ud=14%,YNdll,主变压器低压侧差动保护TA变比为16000\u002F1A,TPY0主变压器高压侧三相短路时，短路点系统侧电流27.5kA’发电机侧短路电流为9.882A,主变压器低压侧三相短路时，系统侧短路电流为93.7kA,本台发电机短路电流为105.3k A，其他发电机短路电流为25.6kA。变压器差动保护采用比率制动型，请根据上述已知条件回答下列问题 差动保护动作特性曲线中折线斜率为（）。",[576,578,580,582],{"key":20,"text":577,"correct":22},"0.1；",{"key":24,"text":579,"correct":22},"0.2；",{"key":27,"text":581,"correct":32},"0.3；",{"key":30,"text":583,"correct":22},"0.4。",{"id":585,"libraryId":5,"type":15,"typeLabel":16,"stem":586,"options":587,"answer":20,"analysis":33},1022701,"对变压器相间短路后备保护，请回答下列问题。 过电流保护主要应用于（）",[588,590,592,594],{"key":20,"text":589,"correct":32},"降压变压器；",{"key":24,"text":591,"correct":22},"升压变压器；",{"key":27,"text":593,"correct":22},"系统联络变压器；",{"key":30,"text":595,"correct":22},"63MVA及以上升压变压器。",{"id":597,"libraryId":5,"type":15,"typeLabel":16,"stem":598,"options":599,"answer":24,"analysis":33},1022702,"对变压器相间短路后备保护，请回答下列问题。 过电流保护的动作电流按躲过可能流过变压器的最大负荷电流计算。其可靠系数和返回系数取值为（ )。",[600,602,604,606],{"key":20,"text":601,"correct":22},"可靠系数1.2~1.3，返回系数0.7~0.8；",{"key":24,"text":603,"correct":32},"可靠系数1.2~1.3，返回系数0.85~0.95;",{"key":27,"text":605,"correct":22},"可靠系数1.5~2.0，返苘系数0.7~0.8；",{"key":30,"text":607,"correct":22},"可靠系数1.5~2.0，返回系数0.85~0.95。",{"id":609,"libraryId":5,"type":15,"typeLabel":16,"stem":610,"options":611,"answer":20,"analysis":33},1022703,"对变压器相间短路后备保护，请回答下列问题。 低电压启动的过电流保护的动作电流取值与过电流保护相同，其低电压元件的整定要求为（）。",[612,614,616,618],{"key":20,"text":613,"correct":32},"按躲过正常运行时可能出现的最低电压整定，一般最低运行电压取值为银定电压的0.9倍，可靠系数取1.1~1.2，返回系数取1.05~1.25；按躲过电动机自启动时的电压整定，当低电压继电器接在变压器低压例时，动作电压取值为頦定电压的0.5~0.6倍，接在变压器高压側时，动作电压取值为額定电压的0.7倍。",{"key":24,"text":615,"correct":22},"按躲过正常运行时可能出现的最低电压整定，一般’最低运行电压取伹为额定电压的0.9倍，可靠系数取1.1~1.2，返田系数取0.85~0.95；.按躲过电动机自启动时的电压整定，当低电压继电器接在变压器低压側时，动作电压取值为額定电压的0.7倍，接在变压器高压侧时，动作电压取值为额定电压的0.5~0.6倍，",{"key":27,"text":617,"correct":22},"按躲过正常运枰时可能出现的表低电压整定，一般最低运行电压取值为额定电压的0.9倍，可靠系数取1.1~1.2,返回系数取0.85~0.95；按躲过电动机自启动时的电压整定，当低电压继电器接在变压器低压側时，动作电压取植为额定电压的0.5~0.6倍，接在变压器.高压侧时，动作电压取值为頦定电压的0.7倍。",{"key":30,"text":619,"correct":22},"按躲过正常运行时可能出现的最低电压整定，一般最低运行电压取值为额定电压的0.9倍，可靠系数取1.1~1.2，返回系数取1.05~1.25；按躲过电动机自启动时的电压整定，当低电压继电器接在变压器低压側时，动作电压取值为额定电压的0.7倍，接在变压器高压側时，动作电压取值为额定电压的0.5~0.6倍。",[621,624,627,630,633,636],{"id":15,"name":622,"category":7,"favorite":623},"领导干部任职前廉政法规知识测试题",92,{"id":625,"name":626,"category":7,"favorite":15},595,"建筑结构与设备",{"id":628,"name":629,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":631,"name":632,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":634,"name":635,"category":7,"favorite":8},534,"BIM工程师",{"id":637,"name":635,"category":7,"favorite":8},535]