[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-18":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":568},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,18,50,2670,[13,34,46,58,70,81,93,105,114,126,138,148,160,172,183,195,207,219,231,241,253,261,269,281,290,302,314,326,335,347,359,368,380,388,397,407,415,424,432,440,452,464,476,488,498,508,520,532,544,556],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1022604,1,"单选题","遥測变送器模拟量输出宜采用()。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","电压输出；",false,{"key":24,"text":25,"correct":22},"B","电流输出；",{"key":27,"text":28,"correct":22},"C","恒压输出；",{"key":30,"text":31,"correct":32},"D","恒流搶出。",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},1022605,"换流阀作整流或逆变运行时，换流阀始终吸收容性无功，对有可能双向送电的直流系统换流变压器交流侧须配置（）。",[38,40,42,44],{"key":20,"text":39,"correct":32},"双向有功电能表和单向无功电能表；",{"key":24,"text":41,"correct":22},"单向有功电能表和双向无功电能表；",{"key":27,"text":43,"correct":22},"双向有功电能表和双向无功电能表；",{"key":30,"text":45,"correct":22},"单向有功电能表和单向无功电能表。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},1022606,"发电机两点接地保护装置应动作于（）。",[50,52,54,56],{"key":20,"text":51,"correct":32},"停机；",{"key":24,"text":53,"correct":22},"解列灭磁；",{"key":27,"text":55,"correct":22},"解列；",{"key":30,"text":57,"correct":22},"降低励磁电流。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},1022607,"保护用电流互感器（包括中间电流互感器）的稳态比误差（）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"不应大于5%；",{"key":24,"text":65,"correct":32},"不应大于10%；",{"key":27,"text":67,"correct":22},"不应大于15%；",{"key":30,"text":69,"correct":22},"不应大于20%。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},1022608,".发电机的后备保护应动作于（）。",[74,75,77,79],{"key":20,"text":51,"correct":22},{"key":24,"text":76,"correct":32},"宜带两段时限，以较短时限动作于缩小故障影响的范围或动作于解列，较长时限动作于停机；",{"key":27,"text":78,"correct":22},"程序跳闸；",{"key":30,"text":80,"correct":22},"解列灭磁。",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":30,"analysis":33},1022609,"宜装设失步保护的发电机的容量为（），",[85,87,89,91],{"key":20,"text":86,"correct":22},"50MW及以上；",{"key":24,"text":88,"correct":22},"100MW及以上；",{"key":27,"text":90,"correct":22},"200MW及以上；",{"key":30,"text":92,"correct":32},"300MW及以上。",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":24,"analysis":33},1022610,"110kV及以上中性点直接接地的电力网中，当低压侧有电源的变压器中性点直接 地运行时，对外部单相接地引起的过电流应装设（）。",[97,99,101,103],{"key":20,"text":98,"correct":22},"零序电压保护；",{"key":24,"text":100,"correct":32},"零序电流保护；",{"key":27,"text":102,"correct":22},"零序电流电压保护；",{"key":30,"text":104,"correct":22},"接于低压例的三相电流保护。",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":30,"analysis":33},1022611,"110、220kV中性点直接接地的电力网中，如低压侧有电源的分级绝缘变压器可能接地或不接地运行时（中性点装有放电间隙)，对外部单相接地故障，应装（）。",[109,110,111,112],{"key":20,"text":100,"correct":22},{"key":24,"text":98,"correct":22},{"key":27,"text":102,"correct":22},{"key":30,"text":113,"correct":32},"零序电流、零序电压和零序电流电压保护。",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":27,"analysis":33},1022612,"髙压侧为500kV的变压器对频率降低和电压升高引起的故障应装设（ ）。",[118,120,122,124],{"key":20,"text":119,"correct":22},"过电压保护；",{"key":24,"text":121,"correct":22},"低頻保护；",{"key":27,"text":123,"correct":32},"过励磁保护；",{"key":30,"text":125,"correct":22},"过电流过电压保护。",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":24,"analysis":33},1022613,"异步电动机当发生单相接地时，接地电流大于（）时，应装单相接地保护，",[130,132,134,136],{"key":20,"text":131,"correct":22},"4A；",{"key":24,"text":133,"correct":32},"5A；",{"key":27,"text":135,"correct":22},"8A；",{"key":30,"text":137,"correct":22},"10A。",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":20,"analysis":33},1022614,"发电机变压器组的低阻抗保护动作出口应为（）。",[142,144,145,146],{"key":20,"text":143,"correct":32},"短时限解列，长时限停机；",{"key":24,"text":53,"correct":22},{"key":27,"text":55,"correct":22},{"key":30,"text":147,"correct":22},"信号.",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":30,"analysis":33},1022615,"对2MW以上的异步电动机的定子绕组及其引出线的相间短路故障，按规定装设（）。",[152,154,156,158],{"key":20,"text":153,"correct":22},"过电流保护；",{"key":24,"text":155,"correct":22},"低电压闭锁过流保护；",{"key":27,"text":157,"correct":22},"电流速断保护；",{"key":30,"text":159,"correct":32},"纵联差动保护.",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":27,"analysis":33},1022616,"3kV及以上应装失步保护的电动机为（）。",[164,166,168,170],{"key":20,"text":165,"correct":22},"1MW及以上异步电动机；",{"key":24,"text":167,"correct":22},"2MW及以上异步电动机；",{"key":27,"text":169,"correct":32},"同步电动机；",{"key":30,"text":171,"correct":22},"2MW及以上的同步电动机。",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":24,"analysis":33},1022617,"3kV及以上应装设专用失磁保护的电动机为()。2MW及以上异步电动机；",[176,178,180,181],{"key":20,"text":177,"correct":22},"2MW及以上同步电机；",{"key":24,"text":179,"correct":32},"同步电动机,",{"key":27,"text":177,"correct":22},{"key":30,"text":182,"correct":22},"1MW及以上同步电机。",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":30,"analysis":33},1022618,"保证同步发电机励磁系统连续运行的条件是()。",[187,189,191,193],{"key":20,"text":188,"correct":22},"励磁电流不超过其颏定励磁电流的1.1倍；",{"key":24,"text":190,"correct":22},"励磁电压不超过其額定励磁电压的1.1倍；",{"key":27,"text":192,"correct":22},"励磁电压和电流不超过額定勘磁电压和电流的1.5倍；",{"key":30,"text":194,"correct":32},"励磁电压和电流不超过额定勘磁电压和电流的1.1倍。",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":27,"analysis":33},1022619,"励磁系统允许的强励时间应（）。",[199,201,203,205],{"key":20,"text":200,"correct":22},"不小于2s；",{"key":24,"text":202,"correct":22},"不小于5s；",{"key":27,"text":204,"correct":32},"不小于10s；",{"key":30,"text":206,"correct":22},"不大于10s。",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":24,"analysis":33},1022620,"同步发电机在空载运行状况下，自动电压调节器和手动控制单元的给定电压变化速度应为每秒不大于发电机额定电压的（），不小于（）。",[211,213,215,217],{"key":20,"text":212,"correct":22},"1.2%,0.5%；",{"key":24,"text":214,"correct":32},"1%,0.3%；",{"key":27,"text":216,"correct":22},"1%,0.5%；",{"key":30,"text":218,"correct":22},"1.2%,0.3%。",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":24,"analysis":33},1022621,"自动调整励磁装置应保证发电机突然零起升压时端电压超调量小于（ ）额定值，调节时间小于（）。",[223,225,227,229],{"key":20,"text":224,"correct":22},"10%,5s；",{"key":24,"text":226,"correct":32},"15%,10s；",{"key":27,"text":228,"correct":22},"10%,10s；",{"key":30,"text":230,"correct":22},"15%,5s。",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":30,"analysis":33},1022622,"发电机一点接地保护装置应动作于（）。",[235,236,237,239],{"key":20,"text":53,"correct":22},{"key":24,"text":55,"correct":22},{"key":27,"text":238,"correct":22},"降低励磁电流；",{"key":30,"text":240,"correct":32},"延时发信。",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":27,"analysis":33},1022623,"励磁系统应保证同步发电机端电压调差率（）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"半导体型±5%，电磁型±5%；",{"key":24,"text":248,"correct":22},"半导体型±5%，电磁型±10%；",{"key":27,"text":250,"correct":32},"半导体型±10%,电磁型±5%；",{"key":30,"text":252,"correct":22},"半导体型±10%,电磁型±10%.",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":24,"analysis":33},1022624,"()容量的发电机，除发电机变压器组共用纵联差动保护外，发电机还应装设单独的纵联差动保护。",[257,258,259,260],{"key":20,"text":86,"correct":22},{"key":24,"text":88,"correct":32},{"key":27,"text":90,"correct":22},{"key":30,"text":92,"correct":22},{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":27,"analysis":33},1022625,"（）容量的发电机变压器组，除发电机变压器组共用纵联差动保护，发电机装设单独的纵联差动保护外，亦可在变压器上增设单独的变压器纵联差动保护。",[265,266,267,268],{"key":20,"text":86,"correct":22},{"key":24,"text":88,"correct":22},{"key":27,"text":90,"correct":32},{"key":30,"text":92,"correct":22},{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":20,"analysis":33},1022626,"容量为300~600MW且颧定低压为18~20kV的汽轮发电机，除制造厂有特殊要求外，其定子绕组单项接地故障电流允许值一般不应超过（）。",[273,275,277,279],{"key":20,"text":274,"correct":32},"1A；",{"key":24,"text":276,"correct":22},"2A；",{"key":27,"text":278,"correct":22},"3A；",{"key":30,"text":280,"correct":22},"4A。",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":24,"analysis":33},1022627,"应装设保护区为100外的定子接地保护的发电机的容量为（）。",[285,286,288,289],{"key":20,"text":86,"correct":22},{"key":24,"text":287,"correct":32},"100MW及以上$",{"key":27,"text":90,"correct":22},{"key":30,"text":92,"correct":22},{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":27,"analysis":33},1022628,"对于200MW及以上的汽轮发电机的过电压保护，在一般情况下，其整定值为（）。",[294,296,298,300],{"key":20,"text":295,"correct":22},"动作电压1.1倍，动作时间0.5s；",{"key":24,"text":297,"correct":22},"动作电压1.3倍，动作时间0.5s；",{"key":27,"text":299,"correct":32},"动作电压1.3倍，动作时间1.0s；",{"key":30,"text":301,"correct":22},"动作电压1.5倍，动作时间1.0s。",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":20,"analysis":33},1022629,"车间内油浸式变压器应装设瓦斯保护的容量为（）。",[306,308,310,312],{"key":20,"text":307,"correct":32},"0.4MVA及以上；",{"key":24,"text":309,"correct":22},"0.8MVA及以上；",{"key":27,"text":311,"correct":22},"1.OMVA及以上；",{"key":30,"text":313,"correct":22},"2.OMVA及以上。",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":30,"analysis":33},1022630,"1MW及以上的发电机，宜装设复合电压启动的过电流保护，该保护的负序电压元件的动作电压可取()倍的额定电压。",[318,320,322,324],{"key":20,"text":319,"correct":22},"0.01~0.07；",{"key":24,"text":321,"correct":22},"0.02~0.08；",{"key":27,"text":323,"correct":22},"0.05~0.011；",{"key":30,"text":325,"correct":32},"0.06~0.12。",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":27,"analysis":33},1022631,"汽轮发电机宜装设逆功率保护的容量为（）。",[330,331,333,334],{"key":20,"text":88,"correct":22},{"key":24,"text":332,"correct":22},"125MW及以上；",{"key":27,"text":90,"correct":32},{"key":30,"text":92,"correct":22},{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":27,"analysis":33},1022632,"变压器容量在10OOOkVA以上时，一般气体继电器气体容积整定为（）。",[339,341,343,345],{"key":20,"text":340,"correct":22},"10Ocm3；",{"key":24,"text":342,"correct":22},"200cm3；",{"key":27,"text":344,"correct":32},"250cm3；",{"key":30,"text":346,"correct":22},"350cm3。",{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":30,"analysis":33},1022633,"高压侧电压为（）的变压器应装设过励磁保护。",[351,353,355,357],{"key":20,"text":352,"correct":22},"35kV；",{"key":24,"text":354,"correct":22},"110kV；",{"key":27,"text":356,"correct":22},"220kV；",{"key":30,"text":358,"correct":32},"500kV及以上，",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":30,"analysis":33},1022634,"()电压等级的电抗器应装设匝间保护，保护带时限动作于跳闸。",[363,364,365,366],{"key":20,"text":352,"correct":22},{"key":24,"text":354,"correct":22},{"key":27,"text":356,"correct":22},{"key":30,"text":367,"correct":32},"330~500kV.",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":30,"analysis":33},1022635,"()容量或以上的电动机，或该容量以下的伹电流速断保护灵敏系数不符合要求的电动机’应装设纵联差动保护。",[372,374,376,378],{"key":20,"text":373,"correct":22},"200kW；",{"key":24,"text":375,"correct":22},"800kW；",{"key":27,"text":377,"correct":22},"10OOkW；",{"key":30,"text":379,"correct":32},"2000kW。",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":30,"analysis":33},1022636,"对电动机的单相接地保护，当单相接地电流为（ ）及以上时，保护应带时限动作于跳闸。",[384,385,386,387],{"key":20,"text":274,"correct":22},{"key":24,"text":133,"correct":22},{"key":27,"text":135,"correct":22},{"key":30,"text":137,"correct":32},{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":24,"analysis":33},1022637,"水轮发电机过电压保护宜动作于（）。",[392,393,394,395],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":32},{"key":27,"text":55,"correct":22},{"key":30,"text":396,"correct":22},"程序跳闸。",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":30,"analysis":33},1022638,"发电机过负荷保护的定时限部分宜动作于（）。",[401,402,403,405],{"key":20,"text":55,"correct":22},{"key":24,"text":78,"correct":22},{"key":27,"text":404,"correct":22},"减出力；",{"key":30,"text":406,"correct":32},"延时动作于信号，有条件时，可自动减负荷。",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":20,"analysis":33},1022639,"()容量的A值大于等于10的发电机，应装设定时限负序过负荷保护，保护动作于信号。",[411,412,413,414],{"key":20,"text":86,"correct":32},{"key":24,"text":88,"correct":22},{"key":27,"text":90,"correct":22},{"key":30,"text":92,"correct":22},{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":24,"analysis":33},1022640,"()容量的A值小于10的发电机，应装设定时限和反时限两部分组成的转子表层过负荷保护，定时限部分保护动作于信号’反时限部分动作于解列或程序跳闸。",[419,421,422,423],{"key":20,"text":420,"correct":22},"250MW及以上；",{"key":24,"text":88,"correct":32},{"key":27,"text":90,"correct":22},{"key":30,"text":92,"correct":22},{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":30,"analysis":33},1022641,"()容量及以上的发电机励磁系统应装设由定时限和反时限保护组成的励磁绕组过负荷保护，定时限部分动作于信号，并动作于降低励磁电流，反时限部分动作于解列灭磁。",[428,429,430,431],{"key":20,"text":86,"correct":22},{"key":24,"text":88,"correct":22},{"key":27,"text":90,"correct":22},{"key":30,"text":92,"correct":32},{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":27,"analysis":33},1022642,"()容量的发电机，其机端及中性点侧电流互感器，应装设断线保护。",[436,437,438,439],{"key":20,"text":86,"correct":22},{"key":24,"text":88,"correct":22},{"key":27,"text":90,"correct":32},{"key":30,"text":92,"correct":22},{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":20,"analysis":33},1022643,"当电力系统受到扰动后，对功率缺额或频率下降的一侧，下列措施中（）是错误的。",[444,446,448,450],{"key":20,"text":445,"correct":32},"切除部分发电机；",{"key":24,"text":447,"correct":22},"切除部分负荷；",{"key":27,"text":449,"correct":22},"对发电机组快速加出力；",{"key":30,"text":451,"correct":22},"将发电机快速由调相改发电运行，快速起动备用机組等.",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":30,"analysis":33},1022644,"电力设备或电力网的保护装置，在系统振荡时，（）是正确的。",[456,458,460,462],{"key":20,"text":457,"correct":22},"当振荡电流危及到设备安全时，允许动作；",{"key":24,"text":459,"correct":22},"距离保护允许动作；",{"key":27,"text":461,"correct":22},"相间电流保护允许动作；",{"key":30,"text":463,"correct":32},"除预先规定的以外，都不允许因系统振荡引起误动作，",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":24,"analysis":33},1022645,"线路保护采用近后备方式，当装设断路器失灵保护时，对220~500kV分相操作的断路器，()是正确的，",[468,470,472,474],{"key":20,"text":469,"correct":22},"只要线路保护正确动作，可不考虑断路器拒动；",{"key":24,"text":471,"correct":32},"只考虑断路器单相拒动的情况；",{"key":27,"text":473,"correct":22},"只考虑断路器两相拒动的情况；",{"key":30,"text":475,"correct":22},"应考虑断路器3相拒动的情况。",{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":24,"analysis":33},1022646,"电力系统承受大扰动能力的第一级安全稳定标准是（）。",[480,482,484,486],{"key":20,"text":481,"correct":22},"保持稳定运行，但允许切机和切负荷；",{"key":24,"text":483,"correct":32},"保持稳定运行和电网的正常供电；",{"key":27,"text":485,"correct":22},"保持稳定运行，但允许损失部分负荷；",{"key":30,"text":487,"correct":22},"当系统不能保持稳定运行时，必须防止系统崩溃并尽量减少负荷损失。",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":27,"analysis":33},1022647,"电力系统承受大扰动能力的第二级安全稳定标准是()。",[492,494,495,496],{"key":20,"text":493,"correct":22},"保持稳定运行，允许切机，不允许切负荷；",{"key":24,"text":483,"correct":22},{"key":27,"text":485,"correct":32},{"key":30,"text":497,"correct":22},"当系统不能保持稳定运行时，必须防止系统崩溃并尽量减少负荷相失。",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":30,"analysis":33},1022648,"电力系统承受大扰动能力的第三级安全稳定标准是()。",[502,503,504,506],{"key":20,"text":483,"correct":22},{"key":24,"text":485,"correct":22},{"key":27,"text":505,"correct":22},"采取切机、切负荷及其他措施，必须保持稳定运行；",{"key":30,"text":507,"correct":32},"当系统不能保持稳定运行时，必须防止系统期溃并尽量减少负荷损失。",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":27,"analysis":33},1022649,"对适用于110kV以上电压线路微机继电保护装置，故瘅测距的精度要求是，对金属性短路不大于线路全长的（）。",[512,514,516,518],{"key":20,"text":513,"correct":22},"±1%；",{"key":24,"text":515,"correct":22},"±2%；",{"key":27,"text":517,"correct":32},"±3%；",{"key":30,"text":519,"correct":22},"±5%。",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":30,"analysis":33},1022650,"微机继电保护装置应装设硬件时钟电路，装置失去直流电源时，硬件时钟应能正常工作。装置时钟本身精度：24h误差不大于（）。",[524,526,528,530],{"key":20,"text":525,"correct":22},"士2s；",{"key":24,"text":527,"correct":22},"±3s；",{"key":27,"text":529,"correct":22},"±4s；",{"key":30,"text":531,"correct":32},"±5s。",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":30,"analysis":33},1022651,"对需要加设电压闭锁的微机母线保护装置，正确的说法是（）。",[536,538,540,542],{"key":20,"text":537,"correct":22},"需要在装置的每个跳闸出口触点回路上串接电压闭锁触点；",{"key":24,"text":539,"correct":22},"可在装置启动出口继电器的逻辑中设里电压闭锁曰路，也可在装置的每个跳闸出口触点回路上串接电压闭钡触点；",{"key":27,"text":541,"correct":22},"C在装置启动出口继电器的逻辑中设置电压闭锁回路，其电压闭锁触点必须串接在装里的每个跳闸出口回路上；",{"key":30,"text":543,"correct":32},"可在装置启动出口继电器的逻辑中设置电压闭锁回路，而不在装置跳闸出口触点回路上串接电压闭锁触点。",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":24,"analysis":33},1022652,"对需要配置两套主保护的设备或线路，错误的说法是()。",[548,550,552,554],{"key":20,"text":549,"correct":22},"每套宜采用主保护与后备保护综合在一起的微机继电保护装置；",{"key":24,"text":551,"correct":32},"一套主保护与后备保护综合在一起，另一套主保护与后备保护必须互相独立；",{"key":27,"text":553,"correct":22},"两套保护装置的直流电源应互相独立；",{"key":30,"text":555,"correct":22},"两套保护装置的电流互感器和电压互感器的二次回路应互相独立。",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":27,"analysis":33},1022653,"以下微机继电保护装置故障记录内容中（）是错误的。",[560,562,564,566],{"key":20,"text":561,"correct":22},"故障时的输入模拟量；",{"key":24,"text":563,"correct":22},"故障时的输入开关量；",{"key":27,"text":565,"correct":32},"高頻保护的高頻通道信息；",{"key":30,"text":567,"correct":22},"动作元件，动作年、月、日、动作时间，动作相别。",[569,572,575,578,581,584],{"id":15,"name":570,"category":7,"favorite":571},"领导干部任职前廉政法规知识测试题",92,{"id":573,"name":574,"category":7,"favorite":15},595,"建筑结构与设备",{"id":576,"name":577,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":579,"name":580,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":582,"name":583,"category":7,"favorite":8},534,"BIM工程师",{"id":585,"name":583,"category":7,"favorite":8},535]