[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-17":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":609},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,17,50,2670,[13,34,46,58,66,78,88,100,112,124,136,148,160,172,184,195,207,219,231,243,255,267,277,289,301,313,325,337,349,357,369,381,393,405,417,429,441,453,465,477,489,501,513,525,537,549,561,573,585,597],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},1022553,1,"单选题","电力系统内部考核用的电能表，其电缆的电压降应不大于（）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","额定二次电压的；",false,{"key":24,"text":25,"correct":22},"B","额定二次电压的0.25%；",{"key":27,"text":28,"correct":29},"C","额定二次电压的0.5%；",true,{"key":31,"text":32,"correct":22},"D","额定二次电压的1%。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},1022554,"水电厂控制回路炼断器应按回路最大负荷电流选择，考虑到熔件的离散性，可靠性系数宜取（），并应满足选择性的要求。",[38,40,42,44],{"key":20,"text":39,"correct":22},"1.2~1.35；",{"key":24,"text":41,"correct":22},"1.25~1.4；",{"key":27,"text":43,"correct":22},"1.4~1.5；",{"key":31,"text":45,"correct":29},"1.3~1.5。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},1022555,"水电厂控制台与模拟屏间的距离应按中央控制室主要通道考虑，布置返回屏时，应考虑的最大视距不大于（），垂直清晰视区不大于（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"3.5m，30°；",{"key":24,"text":53,"correct":22},"4.5m,30°；",{"key":27,"text":55,"correct":22},"3.5m，80°；",{"key":31,"text":57,"correct":29},"4.5m,80°。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},1022556,"水轮机旁屏及励磁屏屏面与发电机上部盖板的距离不宜小于（）。 A.1.2m； E1.5m； C.1.8m； D.2.0m。 ，",[62,63,64,65],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":27,"analysis":33},1022557,"水电厂模拟屏上的设备距屏顶不应小于(），距地面不应小于（）。",[70,72,74,76],{"key":20,"text":71,"correct":22},"500mm,1000mm；",{"key":24,"text":73,"correct":22},"400mm,1100mm；",{"key":27,"text":75,"correct":29},"500mm,1100mm；",{"key":31,"text":77,"correct":22},"400mm,1000mm。",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":20,"analysis":33},1022558,"220~500kV电网线路保护整定计算时，零序电流IV段定值（最末一段）应不小于（）。 A.300A；",[82,84,86],{"key":20,"text":83,"correct":29},"350A；",{"key":24,"text":85,"correct":22},"400A；",{"key":27,"text":87,"correct":22},"500",{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":24,"analysis":33},1022559,"在设计和配置系统安全稳定控制设备时，特别对联网线路及关键性厂站，安全稳定控制装置宜按（）方式配置。",[92,94,96,98],{"key":20,"text":93,"correct":22},"配里一套稳定控制设备；",{"key":24,"text":95,"correct":29},"双重化配置；",{"key":27,"text":97,"correct":22},"双重化配置，另备用一套；",{"key":31,"text":99,"correct":22},"实际情况决定配里数量。",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":24,"analysis":33},1022560,"电力系统的暂态稳定，正确的说法是（）。",[104,106,108,110],{"key":20,"text":105,"correct":22},"电力系统受到小干扰后，不发生非周期性失步，自动恢复到初始运行状态的能力；",{"key":24,"text":107,"correct":29},"电力系统受到大扰动后,各同步电机保持同步运行并过波到新的或恢复到原来稳态运行方式的能力，通常指保持第一或第二个振荡周期不失步的功角稳定；",{"key":27,"text":109,"correct":22},"电力系统受到小的或大的干扰后，在自动调节和控制装置的作用下，保持长过程的运行稳定性的能力；",{"key":31,"text":111,"correct":22},"电力系统受到小的或大的扰动后，系统电压能够保持或恢复到允许的范围内，不发生电压崩溃的能力。",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":24,"analysis":33},1022561,"自动低频减负荷装置整定时，要求在任何情况下的频率下降过程中’为了保证火电厂的继续安全运行，应限制频率低于47.OHz的时间不超过()。",[116,118,120,122],{"key":20,"text":117,"correct":22},"0.3s；",{"key":24,"text":119,"correct":29},"0.5s；",{"key":27,"text":121,"correct":22},"1s；",{"key":31,"text":123,"correct":22},"1.5s。",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":31,"analysis":33},1022562,"自动低频减负荷装置配置整定时，要求自动低频减负荷装置动作后，应使运行系统稳态频率恢复到不低于（）。",[128,130,132,134],{"key":20,"text":129,"correct":22},"49.8Hz；",{"key":24,"text":131,"correct":22},"49.7Hz；",{"key":27,"text":133,"correct":22},"49.6Hz；",{"key":31,"text":135,"correct":29},"49.5Hz.",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":24,"analysis":33},1022563,"自动低频减载装置动作后，因负荷过切引起恢复时系统频率过调，其最大值不应超过（）。",[140,142,144,146],{"key":20,"text":141,"correct":22},"50.5Hz；",{"key":24,"text":143,"correct":29},"51Hz；",{"key":27,"text":145,"correct":22},"51：5HZ；",{"key":31,"text":147,"correct":22},"52HZ.",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":20,"analysis":33},1022564,"\"四统一”设计的综合重合闸装置中“Q\"端子的功能为（）。 ‘",[152,154,156,158],{"key":20,"text":153,"correct":29},"接三相跳闸并允许进行一次三相重合闸的保护；",{"key":24,"text":155,"correct":22},"接三相跳闸后不进行重合闸的保护；",{"key":27,"text":157,"correct":22},"接非全相运行中不退出工作的保护；",{"key":31,"text":159,"correct":22},"接非全相运行中会谈动作的保护，",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":20,"analysis":33},1022565,"220kV系统振荡周期一般可严()。",[164,166,168,170],{"key":20,"text":165,"correct":29},"不大于1.5s；",{"key":24,"text":167,"correct":22},"不小于2s；",{"key":27,"text":169,"correct":22},"不大于2.5s；",{"key":31,"text":171,"correct":22},"不大于3s。",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":27,"analysis":33},1022566,"电力网切除故障时间主要由系统稳定性、发电厂厂用电或重要用户供电电压及电力网保护配合的要求等许多因素决定.按实际情况下允许切除故障最长时间考虑，500kV线路近端故障为（）。",[176,178,180,182],{"key":20,"text":177,"correct":22},"0.06s；",{"key":24,"text":179,"correct":22},"0.07s；",{"key":27,"text":181,"correct":29},"0.08s；",{"key":31,"text":183,"correct":22},"0.1s。",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":24,"analysis":33},1022567,"电力网切除故障时间主要由系统稳定性、发电厂厂用电或重要用户供电电压及电力网保护配合的要求等许多因素决定。按实际情况下允许切除故障最长时间考虑，500kV线路远端故障为（）。",[188,189,191,193],{"key":20,"text":181,"correct":22},{"key":24,"text":190,"correct":29},"0.1s；",{"key":27,"text":192,"correct":22},"0.12s；",{"key":31,"text":194,"correct":22},"0.15s。",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":31,"analysis":33},1022568,"110~220kV直接接地电力网的线路，下列配置原则中（）是正确的，",[199,201,203,205],{"key":20,"text":200,"correct":22},"只装设反应接地短路的保护；",{"key":24,"text":202,"correct":22},"只装设反应相间短路的保护；",{"key":27,"text":204,"correct":22},"只装设零序电流保护；",{"key":31,"text":206,"correct":29},"装设反应相间短路和接地短路的保护，",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":27,"analysis":33},1022569,"对330~500kV线路，一般情况下，应按（ ）原则配置主保护。",[211,213,215,217],{"key":20,"text":212,"correct":22},"配里两套完整的全线速动保护；",{"key":24,"text":214,"correct":22},"配置两套独立的全线速动主保护；",{"key":27,"text":216,"correct":29},"配置两套完整、独立的全线速动主保护；",{"key":31,"text":218,"correct":22},"配置一套完整、独立的全线速动主保护和一套完整、独立的后备保护。",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":20,"analysis":33},1022570,"对220~500kV1个半断路器接线的母线，按（）原则配置母线保护。",[223,225,227,229],{"key":20,"text":224,"correct":29},"每组母线宜装设两套母线保护；",{"key":24,"text":226,"correct":22},"每组母线宜装设一套母线保护；",{"key":27,"text":228,"correct":22},"当每组母线上的连接元件大于3个时，可装设两套母线保护；",{"key":31,"text":230,"correct":22},"当每组母线上连接元件大于5个时，可装设两套母线保护。",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":27,"analysis":33},1022571,"110kV中性点直接接地电力网的线路保护中，相间保护电流回路的电流互感器采用（）方式。",[235,237,239,241],{"key":20,"text":236,"correct":22},"两相式电流互感器；",{"key":24,"text":238,"correct":22},"三相三角形接线；",{"key":27,"text":240,"correct":29},"三相星形接线；",{"key":31,"text":242,"correct":22},"三相三角形或三相星形接线。",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":31,"analysis":33},1022572,"110kV中性点直接接地电力网，线路后备保护的配置原则是（）。",[247,249,251,253],{"key":20,"text":248,"correct":22},"宜采用远近结合的后备方式；",{"key":24,"text":250,"correct":22},"宜采用断路器失灵保护做后备的方式；",{"key":27,"text":252,"correct":22},"宜采用近后备方式；",{"key":31,"text":254,"correct":29},"宜采用远后备方式。",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":24,"analysis":33},1022573,"330~500kV线路主保护的整组动作时间，对近端故障要求不大于（）。",[259,261,263,265],{"key":20,"text":260,"correct":22},"15ms；",{"key":24,"text":262,"correct":29},"20ms；",{"key":27,"text":264,"correct":22},"25ms；",{"key":31,"text":266,"correct":22},"30ms,",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":27,"analysis":33},1022574,"330~500kV线路主保护的整组动作时间，对远端故障（不包括远方信号传输时间）要求不大于（）。",[271,272,273,275],{"key":20,"text":262,"correct":22},{"key":24,"text":264,"correct":22},{"key":27,"text":274,"correct":29},"30ms；",{"key":31,"text":276,"correct":22},"35ms。",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":27,"analysis":33},1022575,"对发电机失磁保护，正确的说法是（）。",[281,283,285,287],{"key":20,"text":282,"correct":22},"失磁保护由阻抗元件和闭锁元件组成；",{"key":24,"text":284,"correct":22},"阻抗元件应按照静稳边界整定，不能按照异步达界整定；",{"key":27,"text":286,"correct":29},"闭锁元件用于防止保护装置在非失磁的其他异常运行方式下误动作；",{"key":31,"text":288,"correct":22},"发电机正常进相运行时，失磁保护应动作。",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":27,"analysis":33},1022576,"()容量的发电机应装设过励磁保护。",[293,295,297,299],{"key":20,"text":294,"correct":22},"100MW及以上；",{"key":24,"text":296,"correct":22},"200MW及以上；",{"key":27,"text":298,"correct":29},"300MW及以上；",{"key":31,"text":300,"correct":22},"600MW及以上。",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":24,"analysis":33},1022577,"对发电机失步保护，错误的说法是（）。",[305,307,309,311],{"key":20,"text":306,"correct":22},"保护可由双阻抗元件或测量板荡中心电庄及变化率等原理构成；",{"key":24,"text":308,"correct":29},"保护在系统短路故障，系统稳定根荡的情况下，应延时动作；",{"key":27,"text":310,"correct":22},"保护动作于信号，在某些情况下应动作于解列；",{"key":31,"text":312,"correct":22},"必要时，失步保护应装设电流闭锁元件.",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":24,"analysis":33},1022578,"500kV系统联络变压器高、中压侧均应装设阻抗保护，保护可带（）时限。",[317,319,321,323],{"key":20,"text":318,"correct":22},"1段；",{"key":24,"text":320,"correct":29},"2段；",{"key":27,"text":322,"correct":22},"3段；",{"key":31,"text":324,"correct":22},"4段。",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":31,"analysis":33},1022579,"110、220kV中性点直接接地的变压器，对外部单相接地引起的过电流，应装设零序电流保护，本零序电流保护由（）组成，每段带()时限。",[329,331,333,335],{"key":20,"text":330,"correct":22},"1段零序电流保护，1个；",{"key":24,"text":332,"correct":22},"2段零序电流保护，2个；",{"key":27,"text":334,"correct":22},"3段零序电流保护，2个；",{"key":31,"text":336,"correct":29},"4段零序电流保护，1个。",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":31,"analysis":33},1022580,"对自耦变压器和高、中压侧中性点都直接接地的三绕组变压器，当零序电流保护有选择性要求时，应增设（）。",[341,343,345,347],{"key":20,"text":342,"correct":22},"零序电流保护段数；",{"key":24,"text":344,"correct":22},"零序电流每段的时限；",{"key":27,"text":346,"correct":22},"零序电流保护套数；",{"key":31,"text":348,"correct":29},"方向元件，",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":24,"analysis":33},1022581,"500kV变压器过励磁保护由（）组成。",[353,354,355,356],{"key":20,"text":318,"correct":22},{"key":24,"text":320,"correct":29},{"key":27,"text":322,"correct":22},{"key":31,"text":324,"correct":22},{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":27,"analysis":33},1022582,"保护用电流互感器的稳态比误差应不大于（）。",[361,363,365,367],{"key":20,"text":362,"correct":22},"5%；",{"key":24,"text":364,"correct":22},"8%；",{"key":27,"text":366,"correct":29},"10%；",{"key":31,"text":368,"correct":22},"15%。",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":31,"analysis":33},1022583,"()容量及以上的发电机应装设发电机低频保护。",[373,375,377,379],{"key":20,"text":374,"correct":22},"50MW；",{"key":24,"text":376,"correct":22},"100MW；",{"key":27,"text":378,"correct":22},"200MW；",{"key":31,"text":380,"correct":29},"300MW.",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":31,"analysis":33},1022584,"装设了过励磁保护的汽轮发电机，可不再装设（ ）保护。",[385,387,389,391],{"key":20,"text":386,"correct":22},"失磁；",{"key":24,"text":388,"correct":22},"失步；",{"key":27,"text":390,"correct":22},"复合电压启动的过电流；",{"key":31,"text":392,"correct":29},"过电压。",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":27,"analysis":33},1022585,"在进行电力系统安全稳定控制系统设计时，请回答以下问题. 为防止暂态（功角）稳定破坏，采用的控制措施不正确的是（）。",[397,399,401,403],{"key":20,"text":398,"correct":22},"在功率过剩地区，快速切除部分发电机；",{"key":24,"text":400,"correct":22},"装设足够数量的自动低頻减载装里；",{"key":27,"text":402,"correct":29},"在功率缺额地区，采用发电机快速加出力；",{"key":31,"text":404,"correct":22},"发电机钱行励磁。",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":27,"analysis":33},1022586,"在进行电力系统安全稳定控制系统设计时，请回答以下问题. 在电力系统出现失步状况时，采用的控制措施不正确的是（）。",[409,411,413,415],{"key":20,"text":410,"correct":22},"在预先安排的适当的系统断面将系统解列；",{"key":24,"text":412,"correct":22},"在功率缺额地区采取切除部分负荷的措施；",{"key":27,"text":414,"correct":29},"c.在功率缺額地区采取快控汽轮机汽门；",{"key":31,"text":416,"correct":22},"在功率过剩地区，为限制頻率过高，装设髙周切机装里。",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":20,"analysis":33},1022587,"在进行安全稳定控制系统远方传送信息的通道设计时，请回答以下问题。 远方传送信息的通道采用的传输媒介，不正确的是（）。",[421,423,425,427],{"key":20,"text":422,"correct":29},"电力电缆；",{"key":24,"text":424,"correct":22},"电力线我波；",{"key":27,"text":426,"correct":22},"微波；",{"key":31,"text":428,"correct":22},"光纤。",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":31,"analysis":33},1022588,"在进行安全稳定控制系统远方传送信息的通道设计时，请回答以下问题。 现需要用64kbit\u002Fs的速率传送安全稳定控制系统的控制策略，选用的通道为（）。",[433,435,437,439],{"key":20,"text":434,"correct":22},"电力线载波；",{"key":24,"text":436,"correct":22},"微波复用设备的音频通道；",{"key":27,"text":438,"correct":22},"光纤复用设务的音频通道；",{"key":31,"text":440,"correct":29},"光纤复用设备的数据通道。",{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":27,"analysis":33},1022589,"对某电力系统装设的低频减载装置进行整定，确定各定值。 基本段快速动作的起始运行频率为（）。",[445,447,449,451],{"key":20,"text":446,"correct":22},"48Hz；",{"key":24,"text":448,"correct":22},"48.5Hz；",{"key":27,"text":450,"correct":29},"49.2Hz；",{"key":31,"text":452,"correct":22},"49.5Hz。",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":20,"analysis":33},1022591,"对某电力系统装设的低频减载装置进行整定，确定各定值。 带较长时间的后备段，最小动作时间为（）。",[457,459,461,463],{"key":20,"text":458,"correct":29},"2~5s；",{"key":24,"text":460,"correct":22},"5~7s；",{"key":27,"text":462,"correct":22},"7~9s；",{"key":31,"text":464,"correct":22},"10~15s。",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":31,"analysis":33},1022592,"对发电机定子绕组及引出线的相间故障应装设专门保护作为发电机主保护。 对发电机变压器组，当发电机变压器之间没有断路器时，100MW及以下发电机应装设（）。",[469,471,473,475],{"key":20,"text":470,"correct":22},"电流速断；",{"key":24,"text":472,"correct":22},"低电压闭锁过流；",{"key":27,"text":474,"correct":22},"发电机纵联差动；",{"key":31,"text":476,"correct":29},"发电机变压器组共用纵联差动。",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":27,"analysis":33},1022593,"对发电机定子绕组及引出线的相间故障应装设专门保护作为发电机主保护。 对发电机变压器组（发电机与变压器间有断路器时）应装设（）。",[481,483,485,487],{"key":20,"text":482,"correct":22},"发电机电流速断；",{"key":24,"text":484,"correct":22},"发电机变压器组共用纵联差动保护；",{"key":27,"text":486,"correct":29},"发电机和变压器分别装设单独的纵联差动保护；",{"key":31,"text":488,"correct":22},"低电压闭锁过电流。",{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":20,"analysis":33},1022594,"电网所需调整容量一般约为（）。",[493,495,497,499],{"key":20,"text":494,"correct":29},"电网总容量的3%~5%；",{"key":24,"text":496,"correct":22},"电网总容量的~7%；",{"key":27,"text":498,"correct":22},"最大负荷的~12%；",{"key":31,"text":500,"correct":22},"最大负荷的8%~12%。",{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":24,"analysis":33},1022595,"两系统之向进行准同步时，必须满足（）。",[505,507,509,511],{"key":20,"text":506,"correct":22},"电流相同、电位相同、频率相等；",{"key":24,"text":508,"correct":29},"电压相等、电位相同、频率相等；",{"key":27,"text":510,"correct":22},"电压相等、相角相同、频率相等；",{"key":31,"text":512,"correct":22},"电压相同、电位相同、功率相同。",{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":24,"analysis":33},1022596,"当系统负荷变动周期约在10s至2~3min之间时，应该进行频率的（）。",[517,519,521,523],{"key":20,"text":518,"correct":22},"一次调整；",{"key":24,"text":520,"correct":29},"二次调整；",{"key":27,"text":522,"correct":22},"三次调整；",{"key":31,"text":524,"correct":22},"—、二次裯整同时进行。",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":31,"analysis":33},1022597,"()不是PAS的功能。",[529,531,533,535],{"key":20,"text":530,"correct":22},"网络建模与网络拓扑；",{"key":24,"text":532,"correct":22},"实时状态估计；",{"key":27,"text":534,"correct":22},"负荷预测；",{"key":31,"text":536,"correct":29},"事故追忆。",{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":27,"analysis":33},1022598,"调度自动化系统主站的人机交互设备为（）。",[541,543,545,547],{"key":20,"text":542,"correct":22},"系统服务器；",{"key":24,"text":544,"correct":22},"网络交换机；",{"key":27,"text":546,"correct":29},"调度员工作站；",{"key":31,"text":548,"correct":22},"前置系统。",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":24,"analysis":33},1022599,"前置系统主要任务为（）。",[553,555,557,559],{"key":20,"text":554,"correct":22},"保护各种历史数据、登录信息、电网管理信息等；",{"key":24,"text":556,"correct":29},"主站与BTU的数据信息通信服务；",{"key":27,"text":558,"correct":22},"用于PAS计算，完成PAS各项功能；",{"key":31,"text":560,"correct":22},"进行人机交互会话。",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":31,"analysis":33},1022600,"主站系统配置中，可不要的设备是()。",[565,567,569,571],{"key":20,"text":566,"correct":22},"服务器与工作站；",{"key":24,"text":568,"correct":22},"网络设备与前置系统；",{"key":27,"text":570,"correct":22},"软件系统；",{"key":31,"text":572,"correct":29},"Web服务器，",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":20,"analysis":33},1022601,"配电网DMS系统总配置分（ ）。",[577,579,581,583],{"key":20,"text":578,"correct":29},"三层：分别是配电终端层、配电子站层、配电主站层；",{"key":24,"text":580,"correct":22},"四层：分别是配电终端层、配电子站层、配电主站层、FTU层；",{"key":27,"text":582,"correct":22},"二层：分别是配电站层、配电主站层；",{"key":31,"text":584,"correct":22},"五层：分别是AMR层、TTU层、FTU层、配电子站层、配电站层。",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":31,"analysis":33},1022602,"监控管理配电网运行的核心层是（）。",[589,591,593,595],{"key":20,"text":590,"correct":22},"FTU层；",{"key":24,"text":592,"correct":22},"配电终端层；",{"key":27,"text":594,"correct":22},"配电子站层；",{"key":31,"text":596,"correct":29},"配电主站层。",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":24,"analysis":33},1022603,"按照规程规定，地区电网调度自动化主站端双机系统可用率为（）。",[601,603,605,607],{"key":20,"text":602,"correct":22},"不小于95%；",{"key":24,"text":604,"correct":29},"不小手99.9%；",{"key":27,"text":606,"correct":22},"不大于99.8%；",{"key":31,"text":608,"correct":22},"小于99.8%。",[610,613,616,619,622,625],{"id":15,"name":611,"category":7,"favorite":612},"领导干部任职前廉政法规知识测试题",92,{"id":614,"name":615,"category":7,"favorite":15},595,"建筑结构与设备",{"id":617,"name":618,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":620,"name":621,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":623,"name":624,"category":7,"favorite":8},534,"BIM工程师",{"id":626,"name":624,"category":7,"favorite":8},535]