[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-16":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":610},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,16,50,2670,[13,34,46,58,66,78,90,102,114,126,138,150,162,174,186,198,210,222,234,246,258,270,282,294,306,318,330,338,350,362,374,386,396,408,420,432,444,454,466,478,490,502,514,526,538,550,562,574,586,598],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},1022503,1,"单选题","在330~500kV高压配电装置敷设的电缆，其额定电压宜选用（）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","250V；",false,{"key":24,"text":25,"correct":22},"B","450\u002F750V；",{"key":27,"text":28,"correct":29},"C","600\u002F1000V；",true,{"key":31,"text":32,"correct":22},"D","800\u002F1200V。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},1022504,"七芯及以上的芯线截面小于（）的较长控制电缆应留有必要的备用芯。",[38,40,42,44],{"key":20,"text":39,"correct":22},"1.5mm2；",{"key":24,"text":41,"correct":22},"2.5mm2；",{"key":27,"text":43,"correct":29},"4mm2；",{"key":31,"text":45,"correct":22},"6mm2。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},1022505,"500kV变电所控制方式为（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"有人值班；",{"key":24,"text":53,"correct":22},"无人值班；",{"key":27,"text":55,"correct":22},"驻所值班；",{"key":31,"text":57,"correct":29},"集中控制和分散控制，",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},1022506,"电厂主控制室主环正面屏（屏台）总长度超过（）宜采用弧型布置。 A.3m； B.4m； C。5m； D.6m。",[62,63,64,65],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":29},{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":31,"analysis":33},1022507,"变电所控制室及网络控制室主环宜采用直列式布置，当总长度超过（）时，也可采用弧形布置。",[70,72,74,76],{"key":20,"text":71,"correct":22},"4m；",{"key":24,"text":73,"correct":22},"5m；",{"key":27,"text":75,"correct":22},"6m；",{"key":31,"text":77,"correct":29},"7m。",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":27,"analysis":33},1022508,"主控制室电气元件的控制接线，宜采用（）。",[82,84,86,88],{"key":20,"text":83,"correct":22},"弱电控制；",{"key":24,"text":85,"correct":22},"DCS控制；",{"key":27,"text":87,"correct":29},"强电一对一控制；",{"key":31,"text":89,"correct":22},"单元集控及远方控制。",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":27,"analysis":33},1022509,"单元控制室的布置位置为（)。",[94,96,98,100],{"key":20,"text":95,"correct":22},"汽机房侧；",{"key":24,"text":97,"correct":22},"锅炉房侧；",{"key":27,"text":99,"correct":29},"主厂房机炉间的适中位置；",{"key":31,"text":101,"correct":22},"辅助厂房侧。",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":31,"analysis":33},1022510,"当采用单个屏时，控制屏和继电器屏宜采用（）尺寸。",[106,108,110,112],{"key":20,"text":107,"correct":22},"宽10OOmm,深600mm,高2300mm；",{"key":24,"text":109,"correct":22},"宽600mm，深550mm，高2300mm；",{"key":27,"text":111,"correct":22},"宽 800mm，深550mm,高2300mm；",{"key":31,"text":113,"correct":29},"宽 800mm,深600mm，高2200mm。",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":24,"analysis":33},1022511,"水电厂控制台立面上的设备布置，上下边净距不小于（），左右倒不应小于（）。",[118,120,122,124],{"key":20,"text":119,"correct":22},"40mm,95mm；",{"key":24,"text":121,"correct":29},"25mm,40mm；",{"key":27,"text":123,"correct":22},"35mm,50mm；",{"key":31,"text":125,"correct":22},"30mm,40mm。",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":20,"analysis":33},1022512,"主控制室的布置位置，下列考虑完善的是（）。",[130,132,134,136],{"key":20,"text":131,"correct":29},"便于运行人员互相联系，便于监视屋外配电装里，控制电缆总长度较短及有较好朝向，以获得有良好的运行条件；",{"key":24,"text":133,"correct":22},"便于运行人员互相联系，控制电缆总长度较短，朝向好，维护方便；",{"key":27,"text":135,"correct":22},"维护、运行及控制方便，控制电缆总长度较短，朝向好；",{"key":31,"text":137,"correct":22},"根据各个电厂地形，布置在便于运行人员互相联系，有良好的运行条件，防火及亊故时，人员安全跪散，控制电缆长度较短。。",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":24,"analysis":33},1022513,"控制屏（屏台）经常操作设备的布置，下列说法正确的是（），",[142,144,146,148],{"key":20,"text":143,"correct":22},"800mm宽的控制屏.(屏台）上，操作设备应布置在便于操作的地方，布置在离地800mm处；",{"key":24,"text":145,"correct":29},"800mm宽的控制屏（屏台）上，每行控制斧关不宜超过5个，经常操作的设备宜布置在离地面800~1500mm处；",{"key":27,"text":147,"correct":22},"功能相同的操作设备应布里在同一水平位置，离地面800~1500mm处；",{"key":31,"text":149,"correct":22},"800mm宽的控制屏（屏台）上，操作设备布置在模拟线以下，便于操作的地方，布置在离地面800~1500mm处。",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":24,"analysis":33},1022514,"继电器屏屏面设备排列次序正确的是（）。",[154,156,158,160],{"key":20,"text":155,"correct":22},"屏上部布置方向、重合闸、信号继电器，中部布置电流、电压、时间继电器，下部布里连接片、切换片及试验部件等；",{"key":24,"text":157,"correct":29},"屏上部布置电流、电压、中间、时间继电器，中部布置方向、差动、重合闸等继电器，下部布置信号继电器、连接片、切换片和试验部件；",{"key":27,"text":159,"correct":22},"屏上部布置信号、时间、中间继电器，中部布置电流、电压、方向、重合闸继电器，下部布里连接片、切换片和试验部件；",{"key":31,"text":161,"correct":22},"屏上部布里时间、中间、电流、电压继电器，中部左侧布里方向继电器，中部右侧布里重合闸继电器，下部布置信号继电器、连接片、切换片和试验部件。",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":20,"analysis":33},1022515,"对于断路器控制回路，以下说法正确的是（）。",[166,168,170,172],{"key":20,"text":167,"correct":29},"控制室控制的断路器应该监視跳、合闸回路，在配电装置就地控制的断路器可只监视跳闸回路；",{"key":24,"text":169,"correct":22},"控制室控制和在配电装里就地控制的断路器都只监视跳闸回路；",{"key":27,"text":171,"correct":22},"控制室控制和在配电装置就地控制的断路器，都应监视跳、合闸回路；",{"key":31,"text":173,"correct":22},"控制室控制的断路器应该监视跳、合闸回路，在配电装里就地控制的断路器可只监视合闸回路。",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":20,"analysis":33},1022516,"当机组采用分散控制系统时，电气部分控制以下说法正确的是（）。",[178,180,182,184],{"key":20,"text":179,"correct":29},"电气和热控自动化水平宜协调一致，其监控范因按单元机组划分，可保留必要的紧急硬手操设备，继电保护、自动准同步、自动电压调节、故障录波和厂用电源快速切换等功能应有专用装置实现；",{"key":24,"text":181,"correct":22},"电气和热控自动化水平宜协调一致，其监控范围以需电气控制的设备为准，继电保护、自动准同步、自动电压调节、故障录波和厂用电源快速切换等功能应有专用装里实现；",{"key":27,"text":183,"correct":22},"电气和热控自动化水平宜协调一致，其监控范围以发电机为单元监控，控制、继电保护自动准同步、自动电压调节、故障录波和厂用电源快速切换等功能由各自系统完成；",{"key":31,"text":185,"correct":22},"电气和热控自动化水平宜协调一致，应保留其硬手操设备，继电保护、自动准同步、自动电压调节、故障录波和厂用电源快速切换等功能由专用装置完成，",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":24,"analysis":33},1022517,"当采用分相操动机构的断路器，并设有综合重合闸或单相重合闸装置时，断路器控制接线下列说法正确的是（）。",[190,192,194,196],{"key":20,"text":191,"correct":22},"宜采用三相联动跳、合闸的控制，亊故时反映开关能单独跳、合闸的功能；",{"key":24,"text":193,"correct":29},"应满足亊故时单相和三相跳、合闸的功能，其他情况下均应采用三相操作控制；",{"key":27,"text":195,"correct":22},"应满足亊故时单相和三相跳、合闸的功能，并能作三相跳、合闸的控制；",{"key":31,"text":197,"correct":22},"能指示亊故时单相和三相跳、合闸位直，并能作三相跳、合闸操作。",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":31,"analysis":33},1022518,"对液压、弹簧和气压操动机构等的合闸电流，一般（）。",[202,204,206,208],{"key":20,"text":203,"correct":22},"为0.5~1A；",{"key":24,"text":205,"correct":22},"不大于2.5A；",{"key":27,"text":207,"correct":22},"不大于3A；",{"key":31,"text":209,"correct":29},"不大于5A。",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":20,"analysis":33},1022519,"下列宜远方及就地操作的是（）。",[214,216,218,220],{"key":20,"text":215,"correct":29},"220~500kV倒闸操作用隔离开关；",{"key":24,"text":217,"correct":22},"220~用隔离开关；",{"key":27,"text":219,"correct":22},"220~500kV接地隔离开关；",{"key":31,"text":221,"correct":22},"220~500kV母线接地隔离开关。",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":27,"analysis":33},1022520,"主控制室设中央信号装置，下列说法正确的是（）。",[226,228,230,232],{"key":20,"text":227,"correct":22},"中央信号装置由瞬时和延时信号部分姐成；",{"key":24,"text":229,"correct":22},"中央信号装置由能重复动作、瞬时预告信号组成；",{"key":27,"text":231,"correct":29},"中央信号装置由亊故信号和预告信号组成；",{"key":31,"text":233,"correct":22},"中央信号装置由瞬时重复动作、延时预告信号组成。",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":31,"analysis":33},1022521,"水电厂控制屏、保护屏上的设备与屏顶净距不应小于（），与左右侧净距不应小于（）。",[238,240,242,244],{"key":20,"text":239,"correct":22},"100mm,120mm；",{"key":24,"text":241,"correct":22},"120mm,100mm；",{"key":27,"text":243,"correct":22},"100mm,50mm；",{"key":31,"text":245,"correct":29},"120mm,50mm。",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":20,"analysis":33},1022522,"户外隔离开关操作闭锁用电源，推荐采用（）电压。",[250,252,254,256],{"key":20,"text":251,"correct":29},"~220V；",{"key":24,"text":253,"correct":22},"~250V；",{"key":27,"text":255,"correct":22},"~380V；",{"key":31,"text":257,"correct":22},"~500V。",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":24,"analysis":33},1022523,"主控制室按规程规定应设置不少于（）出口。",[262,264,266,268],{"key":20,"text":263,"correct":22},"1个；",{"key":24,"text":265,"correct":29},"2个；",{"key":27,"text":267,"correct":22},"3个；",{"key":31,"text":269,"correct":22},"4个。",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":27,"analysis":33},1022524,"关于断路器的防跳回路，以下说法正确的是（）。",[274,276,278,280],{"key":20,"text":275,"correct":22},"由断路器辅助触点及中间继电器组成防跳回路接线；",{"key":24,"text":277,"correct":22},"由断路器辅助触点及串接电阻组成防跳回路接线；",{"key":27,"text":279,"correct":29},"采用电流启动电压自保持的防跳回路接线；",{"key":31,"text":281,"correct":22},"由断路器辅助触点和由电流启动并保持的防跳因路接线。",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":24,"analysis":33},1022525,"水电厂当采用2200mm高定型标准屏时，电能表的水平中心线宜距地（）。",[286,288,290,292],{"key":20,"text":287,"correct":22},"1200~2000mm；",{"key":24,"text":289,"correct":29},"800~1950mm；",{"key":27,"text":291,"correct":22},"800~1800mm；",{"key":31,"text":293,"correct":22},"1400~1700mm。",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":20,"analysis":33},1022526,"隔离开关控制接线原则以下错误的是（）。",[298,300,302,304],{"key":20,"text":299,"correct":29},"装设指示隔离开关的信号，防止在信号指示有电时，拉合隔离开关；",{"key":24,"text":301,"correct":22},"防止带负荷拉（合）隔离开关，故其控制接线必须和相应的断路器闭锁；",{"key":27,"text":303,"correct":22},"防止带电合接地开关或接地器，防止带地线合闸及误入有电间隔；",{"key":31,"text":305,"correct":22},"操作脉冲是短时的，并在完成操作后自动撤除，操作隔离开关应有其所处状态的位置指示信号。",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":27,"analysis":33},1022527,"水电厂设计中，用于（）线路和（）及以上发电机 断路器应有两套独立的跳闸线圈。",[310,312,314,316],{"key":20,"text":311,"correct":22},"110~500kV,125MW；",{"key":24,"text":313,"correct":22},"220~500kV,200MW；",{"key":27,"text":315,"correct":29},"330~500kV,300MW；",{"key":31,"text":317,"correct":22},"330~500kV,600MW。",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":27,"analysis":33},1022528,"下列不设置在返回屏上的信号是（）。",[322,324,326,328],{"key":20,"text":323,"correct":22},"断路器控制回路的分、合信号；",{"key":24,"text":325,"correct":22},"断路器、隔离开关的模拟信号；",{"key":27,"text":327,"correct":29},"亊故音响信号；",{"key":31,"text":329,"correct":22},"事故遥信音响信号和预告信号。",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":27,"analysis":33},1022529,"测量回路的电压互感器二次绕组额定电压为（）。 A.100\u002F√3V；B.100\u002F3V； C100V, D.125V。",[334,335,336,337],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":29},{"key":31,"text":31,"correct":22},{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":24,"analysis":33},1022530,"仪表的测量范围和变比的选择宜满足电力装置回路以额定值的条件运行时，指示在标度尺的（）处。",[342,344,346,348],{"key":20,"text":343,"correct":22},"60%~100%；",{"key":24,"text":345,"correct":29},"70%~100%；",{"key":27,"text":347,"correct":22},"80%~100%；",{"key":31,"text":349,"correct":22},"90%~100%。",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":20,"analysis":33},1022531,"下列设备不需测量负序电流的是（）。",[354,356,358,360],{"key":20,"text":355,"correct":29},"需调峰、调频的发电机；",{"key":24,"text":357,"correct":22},"承受负荷电流过负荷能力较小（常数 10或I2 0.1IN)的大容量汽轮发电机；",{"key":27,"text":359,"correct":22},"向显箸不平衡负荷（如电气机车和冶炼电炉等，负荷不平衡率超过0.1IN者)供电的汽轮发电机；",{"key":31,"text":361,"correct":22},"向显著不平衡负荷（负荷不平衡率超过0.1IN者）送电的3kV及以上线路和用电。",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":27,"analysis":33},1022532,"下列回路不需测量双方向的无功功率的是（ ）。",[366,368,370,372],{"key":20,"text":367,"correct":22},"对有可能进相，滞相运行的同步发电机回路；",{"key":24,"text":369,"correct":22},"发电\u002F电动机和主变压器低压侧装里并联电容器的总回路；",{"key":27,"text":371,"correct":29},"主变压器高压侧回路；",{"key":31,"text":373,"correct":22},"主变压器低压側装有电抗器的总回路。",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":27,"analysis":33},1022533,"对于监视跳、合闸回路的位置指示灯及其附加电阻的选择，下列符合规定要求的是（）。",[378,380,382,384],{"key":20,"text":379,"correct":22},"控制母线电压为1.1倍额定电压时，灯泡电阻与附加电阻限定的电流应不大于跳、合闸线围额定电流的10%；",{"key":24,"text":381,"correct":22},"控制母线电压为额定电压时，灯泡短路情况下，附加电阻的额定电流应不大于跳、合闸线圈額定电流的20%；",{"key":27,"text":383,"correct":29},"C控制母线电压为1.1倍額定电压时，如灯泡短路，附加电阻限定的电流应不大于跳、合闸线圈額定电流的10%来选择附加电阻值；",{"key":31,"text":385,"correct":22},"控制母线电压为1.1倍額定电压时，电阻短路情况下，灯泡限定的电流应不大于跳、合闸线圈额定电流的10%。",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":27,"analysis":33},1022534,"控制电缆的绝缘水平，一般采用的额定电压（无屏蔽）为（ ）。",[390,391,393,394],{"key":20,"text":21,"correct":22},{"key":24,"text":392,"correct":22},"300\u002F500V；",{"key":27,"text":25,"correct":29},{"key":31,"text":395,"correct":22},"600\u002F1000V。",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":31,"analysis":33},1022535,"发电厂计算机监控系统应采集下列（）数据，",[400,402,404,406],{"key":20,"text":401,"correct":22},"故障时间、模拟量、开关量、亊故记录量；",{"key":24,"text":403,"correct":22},"开关量、亊故记录量、有功、无功功率、脉冲量；",{"key":27,"text":405,"correct":22},"发电机电流、电压量、脉冲量、开关量、亊故记录量；",{"key":31,"text":407,"correct":29},"开关量、模拟量、脉冲量、亊故順序记录量。",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":20,"analysis":33},1022536,"以下不属于变电所计算机监控范围的是（）。",[412,414,416,418],{"key":20,"text":413,"correct":29},"直流系统、UPS；",{"key":24,"text":415,"correct":22},"主变压器及联络变压器；",{"key":27,"text":417,"correct":22},"输电线、母线设备及330~500kV并联电抗器；",{"key":31,"text":419,"correct":22},"所用电系统、消防水泵的启动命令。",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":27,"analysis":33},1022537,"水电厂模拟屏采用直列形或弧形布置，当采用弧形布置时，其曲率半径为（）。",[424,426,428,430],{"key":20,"text":425,"correct":22},"8m或10m；",{"key":24,"text":427,"correct":22},"10m或12m；",{"key":27,"text":429,"correct":29},"8m或12m；",{"key":31,"text":431,"correct":22},"10m或15m。",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":24,"analysis":33},1022538,"对具有双重化快速主保护和断路器具有双跳闸线圈的安装单位，关于其二次回路保护，以下说法较正确的是（).",[436,438,440,442],{"key":20,"text":437,"correct":22},"其控制回路和继电保护、自动装置回路应设独立的熔断器或自动开关，并有双电源分别向双重化主保护供电，两组电源间不应有电路上的联系；",{"key":24,"text":439,"correct":29},"其控制回路和继电保护、自动装置回路宜分设独立的熔断器或自动开关，并由双电源分别向双重化主保护供电，两组电源间不应有电路上的联系，继电保护、自动装置屏内电源消失时应有报警信号；",{"key":27,"text":441,"correct":22},"其控制回路和继电保护、自动装置回路，应设独立的总熔断器和自动开关，并由双电源分别向双重化主保护供电，两组电源间不应有电路上的联系；",{"key":31,"text":443,"correct":22},"其控制回路和继电保护、自动装置回路，宜分设独立的总熔断器或自动开关，并由双电源供电,两组电源间不应有电路上的联系。",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":20,"analysis":33},1022539,"水电厂弱电控制电缆、在220kV及以上高压配电装置敷设的电缆，宜选用（）额定电压。",[448,449,451,452],{"key":20,"text":28,"correct":29},{"key":24,"text":450,"correct":22},"500V；",{"key":27,"text":25,"correct":22},{"key":31,"text":453,"correct":22},"250V。",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":24,"analysis":33},1022540,"下列不需监测交流系统的绝缘的是（），",[458,460,462,464],{"key":20,"text":459,"correct":22},"同步发电机的定子回路；",{"key":24,"text":461,"correct":29},"同步发电机的励磁因路；",{"key":27,"text":463,"correct":22},"发电\u002F电动机的定子回路；",{"key":31,"text":465,"correct":22},"中性点非有效接地系统的母线和闽路。.",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":27,"analysis":33},1022541,"熔断器的额定电流应按回路的最大负荷选择，并满足选择性要求，干线上熔断器熔件的额定电流应较支线上的大（）。",[470,472,474,476],{"key":20,"text":471,"correct":22},"1~2级；",{"key":24,"text":473,"correct":22},"1.5~2.5级；",{"key":27,"text":475,"correct":29},"2~3级；",{"key":31,"text":477,"correct":22},"3~4级。",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":27,"analysis":33},1022542,"控制屏、保护屏屏顶绝缘的小母线宜采用（）。",[482,484,486,488],{"key":20,"text":483,"correct":22},"φ4~6mm；",{"key":24,"text":485,"correct":22},"φ5~7mm；",{"key":27,"text":487,"correct":29},"φ6~8mm；",{"key":31,"text":489,"correct":22},"φ8~10mm。",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":27,"analysis":33},1022543,"控制屏、保护屏屏顶绝缘铜棒小母线数量不超过（）。",[494,496,498,500],{"key":20,"text":495,"correct":22},"20条；",{"key":24,"text":497,"correct":22},"24条；",{"key":27,"text":499,"correct":29},"28条；",{"key":31,"text":501,"correct":22},"34条。",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":20,"analysis":33},1022544,"屏后端子排的排列顺序，由上而下（或由左至右），按（）排列是正确的。",[506,508,510,512],{"key":20,"text":507,"correct":29},"电流回路，电压回路，信号回路，控制回路，其他回路，转接回路；",{"key":24,"text":509,"correct":22},"信号回路，电流回路，电压回路，控制闻路，其他回路，转接面路；",{"key":27,"text":511,"correct":22},"电压回路，信号回路，电流回路，控制回路，其他回路，转接回路；",{"key":31,"text":513,"correct":22},"控制回路，电流田路，电压回路，信号回路，其他回路，转接回路。",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":31,"analysis":33},1022545,"二次回路中，（）不能作为隔离电器。",[518,520,522,524],{"key":20,"text":519,"correct":22},"熔断器；",{"key":24,"text":521,"correct":22},"连接片；",{"key":27,"text":523,"correct":22},"不需要拆除导线的特殊端子；",{"key":31,"text":525,"correct":29},"半导体电器。",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":20,"analysis":33},1022546,"音响或灯光监视的控制回路，跳、合闹回路中，跳、合闸位置继电器的选择符合规定的是（）。 A.母线电压为1.1倍額定值时，通过跳、合阑绕组或合闸接器绕组的电流应不大于",[530,532,534,536],{"key":20,"text":531,"correct":29},"其最小动作电流及长期稳定电流，当母线电压为85%额定电压时，加于位里继电器的电压应不小于其额定电压的70%；",{"key":24,"text":533,"correct":22},"在正常情况下，跳、合闸回路的继电器按断路器的合闸或跳闸线圈的额定电流选择，并保证动作的灵敏系数不小于1.5，当母线电压为85%额定电压时，加于继电器的电压不小于其額定电压的70%；",{"key":27,"text":535,"correct":22},"在正常情况下，通过跳、合闸回路的电流应小于其最小动作电流及长期稳定电流，当.母线电压为90%額定电压时，加于继电器的.电压不小于80%；",{"key":31,"text":537,"correct":22},"在正常情况下，通过跳、合闸回路的电流应与启动元件的动作电流配合，并保证动作的炅敏系数不小于1.5，当母线电压为80%額定电压时，加于继电器的电压不小于其額定电压的75%。",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":20,"analysis":33},1022547,"计算机系统的接地，下列说法正确的是（）。",[542,544,546,548],{"key":20,"text":543,"correct":29},"计算机系统内逻辑地、信号地、屏蔽地均应用绝缘铜绞线或电缆接至总接地铜排，达到一点接地的要求；",{"key":24,"text":545,"correct":22},"不同用途、不同设备应分别设里接地装里，经分接装置用绝缘销绞线或电缆引接至总地铜排；",{"key":27,"text":547,"correct":22},"打印机等电噪声较大的外设，可利用三孔插座的接地脚接地；",{"key":31,"text":549,"correct":22},"主机和机拒外壳可就近将接地线引接至主接地两的分支接地线上，然后用绝缘铜故线或电缆引接至总接地锅排，达到“一点接地”的要求.",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":24,"analysis":33},1022548,"水电厂跳、合闸回路继电器的选择，应满足在设备安装处直流电压为额定电压的80%时，加在继电器的电压不应低于额定电压的（）。",[554,556,558,560],{"key":20,"text":555,"correct":22},"65%；",{"key":24,"text":557,"correct":29},"70%；",{"key":27,"text":559,"correct":22},"75%；",{"key":31,"text":561,"correct":22},"80%。",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":31,"analysis":33},1022549,"水电厂二次接线系统的工作电压一般不超过（）。",[566,568,570,572],{"key":20,"text":567,"correct":22},"100V；",{"key":24,"text":569,"correct":22},"220V；",{"key":27,"text":571,"correct":22},"380V；",{"key":31,"text":573,"correct":29},"500V。",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":24,"analysis":33},1022550,"35~110kV无人值班变电所，下列不宜设置在二次设备室的设备是（).",[578,580,582,584],{"key":20,"text":579,"correct":22},"远动终端和相应设备、通信设备；",{"key":24,"text":581,"correct":29},"断路器辅助端子箱、变送器屏、中间转接展；",{"key":27,"text":583,"correct":22},"交直流电源、交流不停电电源；",{"key":31,"text":585,"correct":22},"继电保护、测控、计量和其他自动装置等.",{"id":587,"libraryId":5,"type":15,"typeLabel":16,"stem":588,"options":589,"answer":27,"analysis":33},1022551,"水电厂布置返回屏时，应根据下列（）准确条件决定。",[590,592,594,596],{"key":20,"text":591,"correct":22},"清晰视矩不大于2.5m，最大视距不大于3m，垂直清晰视区不大于65°，水平清晰视区不大于80°和下倾角不大于25°；",{"key":24,"text":593,"correct":22},"清晰视区不大于3m，最大视距不大于4m，垂直清晰視区不大于75°，水平清视区不大于90°和下倾角不大于30°；",{"key":27,"text":595,"correct":29},"清晰视距不大于3. 5m，最大视矩不大于4.5m,垂直清晰视区不大于80°，水平清晰视区不大于100°和下倾角不大于30°等条件综合考虑决定；",{"key":31,"text":597,"correct":22},"清晰视区不大于4m’最大视区不大于4.5m，垂直清晰视区不冬于90°，水平清浙视区不大于100°和下倾角不大于35°。",{"id":599,"libraryId":5,"type":15,"typeLabel":16,"stem":600,"options":601,"answer":20,"analysis":33},1022552,"当水电厂采用电流启动，电压保持的中间继电器构成防眯闭锁接线时，电流线围的額定电流及电压线圈的额定电压选择，下列说法较妥当的是（）。",[602,604,606,608],{"key":20,"text":603,"correct":29},"电流线闽的额定电流可按咯小于跳闸线围动作电流的50%选择，电压线圈的額定电压按直流系统的额定电厍选择s",{"key":24,"text":605,"correct":22},"电流线图的额定电流按跳闸线圈动作电流的50%选择，电压线圑的额定电压按直流系统的额定电压选择；",{"key":27,"text":607,"correct":22},"电流线围的额定电流可按略小于跳闸线困动作电流的60%选择，额定电压按直流系统的额定电压选择；",{"key":31,"text":609,"correct":22},"电流线围的额定电流可按跳闸线围动作电流的50%选择，额定电压按控制回路的操作額定电压选择。",[611,614,617,620,623,626],{"id":15,"name":612,"category":7,"favorite":613},"领导干部任职前廉政法规知识测试题",92,{"id":615,"name":616,"category":7,"favorite":15},595,"建筑结构与设备",{"id":618,"name":619,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":621,"name":622,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":624,"name":625,"category":7,"favorite":8},534,"BIM工程师",{"id":627,"name":625,"category":7,"favorite":8},535]