[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-15":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":589},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,15,50,2670,[13,34,46,58,70,82,94,106,114,124,136,148,160,172,184,196,208,220,232,244,256,268,280,292,304,316,328,340,352,364,376,388,398,410,422,433,443,455,467,477,485,494,506,518,529,541,553,561,569,581],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},1022453,1,"单选题","断路器的跳、合闸回路中的电流启动、电压保持的防跳继电器，其电流自保持线圈的额定电流宜不大于跳、合阐绕组额定电流的（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","50%；",true,{"key":24,"text":25,"correct":26},"B","60%；",false,{"key":28,"text":29,"correct":26},"C","70%；",{"key":31,"text":32,"correct":26},"D","80%。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1022454,"熔断器额定电流的选择应满足选择性要求，干线上熔断器熔件的额定电流应比支线上的大（）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"1~2级；",{"key":24,"text":41,"correct":22},"2~3级；",{"key":28,"text":43,"correct":26},"3~4级；",{"key":31,"text":45,"correct":26},"4~5级.",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},1022455,"二次回路中自动开关瞬时脱扣器断开短路电流的时间应不大于（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"20ms；",{"key":24,"text":53,"correct":26},"30ms；",{"key":28,"text":55,"correct":26},"40ms；",{"key":31,"text":57,"correct":26},"50ms。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},1022456,"继电保护和安全自动装置用电压互感器二次回路电缆截面的选择，应保证最大负荷时，电缆的电压降不得超过额定二次电压的（）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"1%；",{"key":24,"text":65,"correct":26},"2%；",{"key":28,"text":67,"correct":22},"3%；",{"key":31,"text":69,"correct":26},"5%。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},1022457,"由几组电流互感器绕组组合且有电路直接联系的保护回路，如差动保护回路，其电流互感器二次回路接地点设置正确的是（)。",[74,76,78,80],{"key":20,"text":75,"correct":26},"各电流互感器分别接地，接地点在配电装里处；",{"key":24,"text":77,"correct":26},"各电流互感器分别接地，接地点在控制室保护屏；",{"key":28,"text":79,"correct":22},"所有电流互感器共用一个接地点，接地点宜在控制室保护屏；",{"key":31,"text":81,"correct":26},"所有电流互感器共用一个接地点，接地点宜在配电装置处。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},1022458,"负序电流记录表的准确度应不低于（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"0.5级；",{"key":24,"text":89,"correct":26},"1.0级；",{"key":28,"text":91,"correct":26},"1.5级；",{"key":31,"text":93,"correct":22},"2.5级。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},1022459,"()及以上的照明变压器应测量交流电流，",[98,100,102,104],{"key":20,"text":99,"correct":26},"30kVA；",{"key":24,"text":101,"correct":26},"40kVA,",{"key":28,"text":103,"correct":22},"50kVA,",{"key":31,"text":105,"correct":26},"lOOkVA。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":28,"analysis":33},1022460,"直流系统绝缘监測装置的测量准确度不应低于（).",[110,111,112,113],{"key":20,"text":87,"correct":26},{"key":24,"text":89,"correct":26},{"key":28,"text":91,"correct":22},{"key":31,"text":93,"correct":26},{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":20,"analysis":33},1022461,"数字式频率表的准确度不应低于（）。",[118,120,121,122],{"key":20,"text":119,"correct":22},"0.2级；",{"key":24,"text":87,"correct":26},{"key":28,"text":89,"correct":26},{"key":31,"text":123,"correct":26},"1.5级。",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":24,"analysis":33},1022462,"电能表的过载倍数应为（）。",[128,130,132,134],{"key":20,"text":129,"correct":26},"2倍及以上；",{"key":24,"text":131,"correct":22},"4倍及以上；",{"key":28,"text":133,"correct":26},"6倍及以上；",{"key":31,"text":135,"correct":26},"8.倍及以上。",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":20,"analysis":33},1022463,"对经电流互感器接入的S级电能表，其标定电流宜不低于电流互感器额定二次电流的（）。",[140,142,144,146],{"key":20,"text":141,"correct":22},"20%；",{"key":24,"text":143,"correct":26},"30%；",{"key":28,"text":145,"correct":26},"40%；",{"key":31,"text":147,"correct":26},"50%。",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":28,"analysis":33},1022464,"对经电流互感器接入的S级电能表，其额定最大电流为电流互感器额定二次电流的（）。",[152,154,156,158],{"key":20,"text":153,"correct":26},"80%左右；",{"key":24,"text":155,"correct":26},"100%左右；",{"key":28,"text":157,"correct":22},"120%左右；",{"key":31,"text":159,"correct":26},"140%左右。",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":20,"analysis":33},1022465,"发电厂采用计算机监控系统后，操作员站台宜保留的硬手操包括（）。",[164,166,168,170],{"key":20,"text":165,"correct":22},"发电机变压器组断路器紧急跳闸按钮、发电机灭磁开关紧急跳闸按钮、柴油发电机启动按钮；",{"key":24,"text":167,"correct":26},"发电机变压器组断路器紧急合闸和跳闸按钮、发电机灭磁开关紧急合闸和跳闸按钮、柴油发电机启动按钮；",{"key":28,"text":169,"correct":26},"发电机变压器组断路器紧急跳闸按钮、发电机灭磁开关紧急跳闸按钮、高压疒用工作变压器高压侧断路器紧急跳闸按钮、启动备用变压器高低压侧断路器紧急合闸按钮；",{"key":31,"text":171,"correct":26},"发电机变压器组断路器紧急合闹和跳闸按钮、发电机灭磁开关紧急合闸和跳闸按钮。",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":31,"analysis":33},1022466,"下列不符合发电机顺序控制规定的要求的是(）。",[176,178,180,182],{"key":20,"text":177,"correct":26},"发电机变压器组顺序控制时应与整套炉、机、电顺序控制相配合；",{"key":24,"text":179,"correct":26},"顺序控制应能与软手操实现无扰动切换；",{"key":28,"text":181,"correct":26},"机组的启停过程应与厂用系统的切换相配合；",{"key":31,"text":183,"correct":22},"发电机变压器组由DCS顺控时，宜设里手动准同步。",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":20,"analysis":33},1022467,"单机容量为（）的发电厂，宜采用主控制室的控制方式。",[188,190,192,194],{"key":20,"text":189,"correct":22},"10OMW及以下；",{"key":24,"text":191,"correct":26},"125MW及以上；",{"key":28,"text":193,"correct":26},"200MW及以上；",{"key":31,"text":195,"correct":26},"300MW及以上。",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":24,"analysis":33},1022468,"单元控制室的电气元件控制接线应采用（）方式。",[200,202,204,206],{"key":20,"text":201,"correct":26},"PLC控制；",{"key":24,"text":203,"correct":22},"强电控制或分散控制系统控制；",{"key":28,"text":205,"correct":26},"弱电控制；",{"key":31,"text":207,"correct":26},"强电控制。",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":24,"analysis":33},1022469,"某发电厂扩建一台125MW发电机，其额定功率因数cosψ= 0.85，额定电压为13.8kV,采用发电机变压器组接入220kV母线，发电机一次额定电流为6150 A，电压互感器一次额定电压为15kV，电流互感器一次额定电流为8000A。 二次测量电流表满刻度值应选用（）。",[212,214,216,218],{"key":20,"text":213,"correct":26},"7500A；",{"key":24,"text":215,"correct":22},"8000A；",{"key":28,"text":217,"correct":26},"8500A；",{"key":31,"text":219,"correct":26},"9OOOA。",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":31,"analysis":33},1022470,"某发电厂扩建一台125MW发电机，其额定功率因数cosψ= 0.85，额定电压为13.8kV,采用发电机变压器组接入220kV母线，发电机一次额定电流为6150 A，电压互感器一次额定电压为15kV，电流互感器一次额定电流为8000A。 二次測量电压表满刻度值应选用（）。",[224,226,228,230],{"key":20,"text":225,"correct":26},"13.8kV；",{"key":24,"text":227,"correct":26},"15.8kV；",{"key":28,"text":229,"correct":26},"16.56kV；",{"key":31,"text":231,"correct":22},"18kV。",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":31,"analysis":33},1022471,"电流互感器的选择和校验。 下列不是电流互感器误差曲线校验的步骤的是（）。",[236,238,240,242],{"key":20,"text":237,"correct":26},"确定电流互感器实际二次负荷计算值；",{"key":24,"text":239,"correct":26},"计算电流互感器一次计算电流倍数；",{"key":28,"text":241,"correct":26},"查10%误差曲线；",{"key":31,"text":243,"correct":22},"确定电流互感器的额定电压。",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":24,"analysis":33},1022472,"电流互感器的选择和校验。 电流互感器一次电流变化的大小对误差的影响，说法正确的是()。",[248,250,252,254],{"key":20,"text":249,"correct":26},"不影响电流互感器的误差；",{"key":24,"text":251,"correct":22},"会影响电流误差和角误差；",{"key":28,"text":253,"correct":26},"只影响电流误差；",{"key":31,"text":255,"correct":26},"只影响角误差。",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":20,"analysis":33},1022473,"电流互感器的选择和校验。 下列不是影响电流互感器误差因素的是（）。",[260,262,264,266],{"key":20,"text":261,"correct":22},"电流互感器变比；",{"key":24,"text":263,"correct":26},"二次例功率因数变化；",{"key":28,"text":265,"correct":26},"一次电流I1的大小；",{"key":31,"text":267,"correct":26},"电流頻率变化。",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":24,"analysis":33},1022474,"电压互感器电压及电缆截面选择。 选择用于中性点非直接接地系统的三相电压互感器时，其第三绕组的电压应为（）。",[272,274,276,278],{"key":20,"text":273,"correct":26},"100V；",{"key":24,"text":275,"correct":22},"100\u002F3V；",{"key":28,"text":277,"correct":26},"100\u002F√3V；",{"key":31,"text":279,"correct":26},"100V或100\u002F√3。",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":28,"analysis":33},1022475,"电压互感器电压及电缆截面选择。",[284,286,288,290],{"key":20,"text":285,"correct":26},"电测量用电压互感器二次回路电缆截面的选择，应使电力系统内部的0.5级电能表电缆的电压降不大于額定二次电压的（）。",{"key":24,"text":287,"correct":26},"0.2%；",{"key":28,"text":289,"correct":22},"0.25%； C0.5%；",{"key":31,"text":291,"correct":26},"1%。",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":28,"analysis":33},1022476,"主接线采用一个半断路器接线时，电流互感器和电压互感器的配置。 关于电流互感器的配置，下列说法正确的是（）。",[296,298,300,302],{"key":20,"text":297,"correct":26},"对采用一个半断路器接线时，一般应按二相配里，每串宜配置三组；",{"key":24,"text":299,"correct":26},"对采用一个半断路器接线时，对独立式电流互感器，每串宜配里三组；",{"key":28,"text":301,"correct":22},"对采用一个半断路器接线时，对独立式电流互感器，每串应配里三组；",{"key":31,"text":303,"correct":26},"对采用一个半断路器接线时，对独立式电流互感器，每串宜配里四组。",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":20,"analysis":33},1022477,"主接线采用一个半断路器接线时，电流互感器和电压互感器的配置。 关于电压互感器的配置，下列说法正确的是（）。",[308,310,312,314],{"key":20,"text":309,"correct":22},"当主接线为一个半断路器接线时，线路与变压器回路宜装设三相电压互感器，母线宜装设一相电压互感器；",{"key":24,"text":311,"correct":26},"当主接线为一个半断路器接线时，线路与变压器回路应装设三相电压互感器，母线宜装设一相电压互感器；",{"key":28,"text":313,"correct":26},"当主接线为一个卒断路器接线时，线路应装三相电压互感器，变压器与母线宜装设二相电压互感器；",{"key":31,"text":315,"correct":26},"当主接线为一个半断路器接线时，线路与变压器，母线均宜装设三相电压互感器。",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":28,"analysis":33},1022478,"国家对电压互感器的准确级及比值误差的标准， 电压互感器二次绕组的准确级不符合标准的是（）。",[320,322,324,326],{"key":20,"text":321,"correct":26},"0.2和0.5级；",{"key":24,"text":323,"correct":26},"1级；",{"key":28,"text":325,"correct":22},"1.5；",{"key":31,"text":327,"correct":26},"3级。",{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":28,"analysis":33},1022479,"国家对电压互感器的准确级及比值误差的标准， 关于电压互感器二次绕组的准确级和误差值，（ ）是不对的。",[332,334,336,338],{"key":20,"text":333,"correct":26},"0.5准确级，比值误差±0.5%,相角误差±20%；",{"key":24,"text":335,"correct":26},"1准确级，比值误差±1%，相角误差土40%；",{"key":28,"text":337,"correct":22},"1.5准确级，比值误差±1.5%，相角误差土50%；",{"key":31,"text":339,"correct":26},"3准确级，比值误差±3%，相角误差不规定。",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":31,"analysis":33},1022480,"35~110kV无人值班变电所的控制要求。 下列电气一次设备，不在远方控制端控制的是（）。",[344,346,348,350],{"key":20,"text":345,"correct":26},"6~110kV线路，主变压器，母线各电容器的断路器，负荷开关；",{"key":24,"text":347,"correct":26},"主变压器有载调压分接开关；",{"key":28,"text":349,"correct":26},"需要远方控制改变运行方式的主变压器中性点接地隔离开关；",{"key":31,"text":351,"correct":22},"需改变运行方式的母线切换隔离开关。",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":31,"analysis":33},1022481,"35~110kV无人值班变电所的控制要求。 下列变电所的设备可不采用自动控制的是（）。",[356,358,360,362],{"key":20,"text":357,"correct":26},"主变压器有载分接开关调节；",{"key":24,"text":359,"correct":26},"并联电容器组投切；",{"key":28,"text":361,"correct":26},"蓄电池组充电、直流母线电压调节；",{"key":31,"text":363,"correct":22},"110kV线路断路器的合、跳闸。",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":24,"analysis":33},1022482,"水电厂控制和信号设备的选择： 关于跳、合闸回路位置继电器的选择，下列说法正确的是（）。",[368,370,372,374],{"key":20,"text":369,"correct":26},"当设备安装处，直流电压为额定电压的85%时，加于继电器的电压不应小于其額定电压的70%；",{"key":24,"text":371,"correct":22},"当设备安政处直流电压为额定电压的80%时，加于继电器的电压不应小于其颏定电压的70%；",{"key":28,"text":373,"correct":26},"当设备安装处直流电压为额定电压的80%时，加于继电器的电压不应小于其額定电压的80%；",{"key":31,"text":375,"correct":26},"当设备安装处直流电压为額定电压的85%时，加于继电器的电压宜不小于其額定电压的70%。",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":31,"analysis":33},1022483,"水电厂控制和信号设备的选择： 对于信号继电器和附加电阻的选择，下列说法正确的是（）。",[380,382,384,386],{"key":20,"text":381,"correct":26},"当设备安装处的直流电压为額定电压的80%,由串联信号继电器引起田路的电压降不应大于额定电压的20%；",{"key":24,"text":383,"correct":26},"当设备安装处的直流电压为额定电压的80%，由争联信号继电器引起回路的电压降不宜大于額定电压的20%；",{"key":28,"text":385,"correct":26},"当设备安装处的直流电压为额定电压的80%，由串联信号继电器引起回路的电压降不宜大于額定电压的10%；",{"key":31,"text":387,"correct":22},"当设备安装处的直流电压为额定电压的80%,由串联信号继电器引起回路的电压降不应大于額定电压的10%。",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":28,"analysis":33},1022484,"火电厂二次回路自动开关额定电流的选择。 干线上的自动开关脱扣器的额定电流应较支线上的大（）。",[392,393,395,396],{"key":20,"text":39,"correct":26},{"key":24,"text":394,"correct":26},"1.5~2.5级；",{"key":28,"text":41,"correct":22},{"key":31,"text":397,"correct":26},"2.5~3.5级。",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":31,"analysis":33},1022485,"火电厂二次回路自动开关额定电流的选择。 电压互感器二次侧自动开关瞬时脱扣器断开短路电流的时间应不大于()。",[402,404,406,408],{"key":20,"text":403,"correct":26},"5ms；",{"key":24,"text":405,"correct":26},"1ms；",{"key":28,"text":407,"correct":26},"15ms；",{"key":31,"text":409,"correct":22},"20ms。",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":24,"analysis":33},1022486,"发电厂和变电所的控制电缆和绝缘导线按机械强度要求。 强电裨制回路导体截面（铜芯）应不小于（）。",[414,416,418,420],{"key":20,"text":415,"correct":26},"1mm2；",{"key":24,"text":417,"correct":22},"1.5mm2；",{"key":28,"text":419,"correct":26},"2.5mm2；",{"key":31,"text":421,"correct":26},"4mm2。",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":20,"analysis":33},1022487,"发电厂和变电所的控制电缆和绝缘导线按机械强度要求。 弱电控制回路导体截面（铜芯）应不小于（ ）。",[426,428,430,431],{"key":20,"text":427,"correct":22},"0.5mm2；",{"key":24,"text":429,"correct":26},"mm2；",{"key":28,"text":417,"correct":26},{"key":31,"text":432,"correct":26},"2mm2。",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":28,"analysis":33},1022488,"发电厂和变电所的控制电缆和绝缘导线按机械强度要求。 电磁式自动电压校正器的连接电缆芯的截面（锎芯）不应小于（）。",[437,438,439,441],{"key":20,"text":417,"correct":26},{"key":24,"text":419,"correct":26},{"key":28,"text":440,"correct":22},"4mm2；",{"key":31,"text":442,"correct":26},"6mm2。",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":28,"analysis":33},1022489,"发电厂和变电所的控制电缆和绝缘导线按机械强度要求。 电测量仪表用电压互感器二次回路，指针式仪表电缆的电压降应不大于额定二次电压的（）。",[447,449,451,453],{"key":20,"text":448,"correct":26},"0.5k~1%；",{"key":24,"text":450,"correct":26},"1%~2%；",{"key":28,"text":452,"correct":22},"1%~3%；",{"key":31,"text":454,"correct":26},"l%~4%。",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":31,"analysis":33},1022490,"计算机系统接地线截面的选择（采用绝缘锎绞线或电缆为接地线〉。 总接地板至接地点连线为（）。",[459,461,463,465],{"key":20,"text":460,"correct":26},"10mm2；",{"key":24,"text":462,"correct":26},"16mm2；",{"key":28,"text":464,"correct":26},"24mm2；",{"key":31,"text":466,"correct":22},"35mm2。",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":28,"analysis":33},1022491,"计算机系统接地线截面的选择（采用绝缘锎绞线或电缆为接地线〉。 计算机系统地（逻辑地、信号地、屏蔽地）至总接地板的连接为（）。",[471,473,474,475],{"key":20,"text":472,"correct":26},"6mm2；",{"key":24,"text":460,"correct":26},{"key":28,"text":462,"correct":22},{"key":31,"text":476,"correct":26},"20mm2。",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":20,"analysis":33},1022492,"计算机系统接地线截面的选择（采用绝缘锎绞线或电缆为接地线）。 机柜间链式接地连接线为（）。",[481,482,483,484],{"key":20,"text":417,"correct":22},{"key":24,"text":419,"correct":26},{"key":28,"text":440,"correct":26},{"key":31,"text":442,"correct":26},{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":20,"analysis":33},1022493,"计算机系统接地线截面的选择（采用绝缘锎绞线或电缆为接地线〉。 机柜与钢筋接地连接线为（）。",[489,490,491,492],{"key":20,"text":419,"correct":22},{"key":24,"text":440,"correct":26},{"key":28,"text":472,"correct":26},{"key":31,"text":493,"correct":26},"8mm2。",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":28,"analysis":33},1022494,"对（）及以上容量的低压电动机回路宜测量交流电流。",[498,500,502,504],{"key":20,"text":499,"correct":26},"30kW；",{"key":24,"text":501,"correct":26},"45kW；",{"key":28,"text":503,"correct":22},"55kW；",{"key":31,"text":505,"correct":26},"75kW。",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":20,"analysis":33},1022495,"下列应监测交流系统的绝缘的回路为（）母线。",[510,512,514,516],{"key":20,"text":511,"correct":22},"6kV不接地系统；",{"key":24,"text":513,"correct":26},"110kV接地系统；",{"key":28,"text":515,"correct":26},"220kV接地系统；",{"key":31,"text":517,"correct":26},"500kV接地系.统。",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":24,"analysis":33},1022496,"总装机容量为（）的火力发电厂（非调频、调峰电厂）痛要在主控制室监视和记录主电网频率。",[522,524,525,527],{"key":20,"text":523,"correct":26},"100MW及以上；",{"key":24,"text":193,"correct":22},{"key":28,"text":526,"correct":26},"100MW以下；",{"key":31,"text":528,"correct":26},"200MW以下。",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":31,"analysis":33},1022497,"具有电流和电压线闺的中间继电器，其电流和电压线圃间的耐压水平不应低于（）。",[533,535,537,539],{"key":20,"text":534,"correct":26},"500V、1min；",{"key":24,"text":536,"correct":26},"600V、1min；",{"key":28,"text":538,"correct":26},"800V、1min；",{"key":31,"text":540,"correct":22},"1000V,lmin。",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":28,"analysis":33},1022498,"额定电压时信号继电器的电流灵敏系数宜不小于（）。",[545,547,549,551],{"key":20,"text":546,"correct":26},"1.2；",{"key":24,"text":548,"correct":26},"1.3；",{"key":28,"text":550,"correct":22},"1.4；",{"key":31,"text":552,"correct":26},"1.5。",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":31,"analysis":33},1022499,"电压互感器二次侧自动开关瞬时脱扣器的动作电流，应按大于电压互感器二次回路的最大负荷电流来整定，其可靠系数应取（)。",[557,558,559,560],{"key":20,"text":546,"correct":26},{"key":24,"text":548,"correct":26},{"key":28,"text":550,"correct":26},{"key":31,"text":552,"correct":22},{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":28,"analysis":33},1022500,"控制回路电缆截面的选择，应保证最大负荷时，控制电源母线至被控设备间连接电缆的电压降不应超过额定二次电压的（）。 A.5%； B10%； C.12%； D.15%.",[565,566,567,568],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":26},{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":24,"analysis":33},1022501,"强电控制电缆的额定电压不应低于（）。",[573,575,577,579],{"key":20,"text":574,"correct":26},"250V；",{"key":24,"text":576,"correct":22},"450\u002F750V；",{"key":28,"text":578,"correct":26},"600\u002F1000V；",{"key":31,"text":580,"correct":26},"800\u002F1200V。",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":20,"analysis":33},1022502,"弱电控制电缆的额定电压不应低于（ ）。",[585,586,587,588],{"key":20,"text":574,"correct":22},{"key":24,"text":576,"correct":26},{"key":28,"text":578,"correct":26},{"key":31,"text":580,"correct":26},[590,593,596,599,602,605],{"id":15,"name":591,"category":7,"favorite":592},"领导干部任职前廉政法规知识测试题",92,{"id":594,"name":595,"category":7,"favorite":15},595,"建筑结构与设备",{"id":597,"name":598,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":600,"name":601,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":603,"name":604,"category":7,"favorite":8},534,"BIM工程师",{"id":606,"name":604,"category":7,"favorite":8},535]