[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-14":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":592},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,14,50,2670,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,282,294,306,314,326,335,343,355,367,376,385,397,409,421,433,445,457,468,480,492,503,515,525,537,546,557,568,580],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},1022403,1,"单选题","电流互感器的二次回路接地点，下列说法正确的是（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","电流互感器的二次面路应有且只能有一个接地点，宜在配电装置处经端子接地；",true,{"key":24,"text":25,"correct":26},"B","电流互感器二次回路应有一个接地点，在配电装里处经端子接地；",false,{"key":28,"text":29,"correct":26},"C","电流互感器二次回路不允许多点接地，只能在配电装里处经端子接地；",{"key":31,"text":32,"correct":26},"D","电洗互感器二次回路应只有一点在配电装置处经端子接地。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1022404,"水电厂电气设计中，（）及以上电压的断路器应有电气防跳接线。",[38,40,42,44],{"key":20,"text":39,"correct":26},"110kV；",{"key":24,"text":41,"correct":22},"35kV；",{"key":28,"text":43,"correct":26},"10kV；",{"key":31,"text":45,"correct":26},"6kV?",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},1022405,"当几种测量仪表接在电流互感器同一个二次绕组时，下列所接仪表排列正确的是（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"宜先接指示仪表（包括接有指示仪表的变送器）、积算仪表，其次接记录仪表，最后接发送仪表；",{"key":24,"text":53,"correct":26},"宜先接记录仪表、指示仪表（包括接有指示仪表的变送器），其次接积算仪表，最后接发送仪表；",{"key":28,"text":55,"correct":26},"C宜先接积算仪表、指示仪表（包括接有指示仪表的变送器)，其次接记录仪表，最后接发送仪表；",{"key":31,"text":57,"correct":26},"宜先接指示仪表（包括接有指示仪表的变送器）、记录仪表，其次接积算仪表，最后接发送仪表。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},1022406,"某电厂有两台300MW机组，采用发电机变压器组向500kV系统送电。 根据现有控制水平，该电厂考虑()控制接线较合适。",[62,64,66,68],{"key":20,"text":63,"correct":26},"单元控制室钱电一对一控制接线；",{"key":24,"text":65,"correct":26},"主控制室弦电一对一控制接线；",{"key":28,"text":67,"correct":22},"单元控制室计算机监控接线，在发电机控制屏上保留部分必须的硬手操设备元件；",{"key":31,"text":69,"correct":26},"全部用计算机监控的接线。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},1022407,"某电厂有两台300MW机组，采用发电机变压器组向500kV系统送电。 如采用强电一对一控制接线，对于500kV断路器控制开关，不厲于断路器控制回路的要求的是()。",[74,76,78,80],{"key":20,"text":75,"correct":26},"断路器控制回路应有电源监视，并宜监视跳、合闸绕组回路的完整性；",{"key":24,"text":77,"correct":22},"应能指示保护动作，重合闸位直信号；",{"key":28,"text":79,"correct":26},"应能指示断路器合闸与跳闸的位置状态，自动合闸或跳闸时应有明至信号；",{"key":31,"text":81,"correct":26},"合闸和跳闸完成后应使命令脉冲自动解除，有防止断路器跳跃的电气闭锁。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},1022408,"某电厂有两台300MW机组，采用发电机变压器组向500kV系统送电。 主接线为一个半断路器接线时，为使二次接线运行调试方便，下列安装单位的划分不正确的是（）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"当为线路一线路串时，每条出线作为一个安装单位，每台断路器为一个安装单位；",{"key":24,"text":89,"correct":26},"当为线路一变压器串时，变压器、出线，每台断路器各为一个安装单位；",{"key":28,"text":91,"correct":26},"当线路接有并联电抗器时，并联电抗器可单独作为一个安装单位，也可和线路合设一个安装单位；",{"key":31,"text":93,"correct":22},"每台断路器及变压器均可作为独立的安装单位。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},1022409,"发电厂的控制室采用灯光监视. 对于控制室灯光监视的控制信号回路，完整的说法是（）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"采用控制开关KK的位里与断路器的位里不对应接线，正常合闸时红灯亮，跳闸时绿灯亮，故障时红灯闪光；",{"key":24,"text":101,"correct":26},"采用控制开关控制，红、绿灯监视跌、合闸回路；",{"key":28,"text":103,"correct":26},"用控制开关控制，正常时指示灯不亮，故障时指示灯亮；",{"key":31,"text":105,"correct":22},"采用控制开关KK的位里与断路器位里不对应接线，用红、绿灯监视断路器跳、合闸回路，正常合闸时红灯亮，跳闸时绿灯亮，故障时绿灯闪光。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},1022410,"发电厂的控制室采用灯光监视. 对于就地控制断路器的控制和信下列说法不正确的是（）。",[110,112,114,116],{"key":20,"text":111,"correct":26},"监视电源和跳闸回路完整性，对合闸回路可不监视；",{"key":24,"text":113,"correct":26},"指示断路器的位置状态；",{"key":28,"text":115,"correct":26},"亊故姚闸应有明显的信号；",{"key":31,"text":117,"correct":22},"应有防止跳跃的电气闭锁装里，跳、合闸命令脉冲采用手动解除。",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},1022411,"某发电厂扩建一台200MW发电机。 在发电机控制台立面上，下列表计不属于立面上安装的设备的有()。",[122,124,126,128],{"key":20,"text":123,"correct":26},"选测表计；",{"key":24,"text":125,"correct":26},"经常监视的常測表计；",{"key":28,"text":127,"correct":26},"同步表计；",{"key":31,"text":129,"correct":22},"记录表计。",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},1022412,"某发电厂扩建一台200MW发电机。 测量回路的额定电流及电压，（）是不恰当的值。",[134,136,138,140],{"key":20,"text":135,"correct":26},"1A；",{"key":24,"text":137,"correct":22},"2.5A；",{"key":28,"text":139,"correct":26},"5A；",{"key":31,"text":141,"correct":26},"100V。",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":31,"analysis":33},1022413,"某发电厂扩建一台200MW发电机。 常用测量仪表的准确度最低要求，不正确的是（）。",[146,148,150,152],{"key":20,"text":147,"correct":26},"指针式交流仪表1.5级；",{"key":24,"text":149,"correct":26},"指针式直流仪表1.5级；",{"key":28,"text":151,"correct":26},"数字式仪表0.5级；",{"key":31,"text":153,"correct":22},"指针式经变送器二次测量的直流仪表1.5级。",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":28,"analysis":33},1022414,"为提髙低负荷时的计量准确性： 应选用过载（）的电能表。",[158,160,162,164],{"key":20,"text":159,"correct":26},"2倍；",{"key":24,"text":161,"correct":26},"3倍；",{"key":28,"text":163,"correct":22},"4倍及以上；",{"key":31,"text":165,"correct":26},"5倍。",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},1022415,"为提髙低负荷时的计量准确性： 对经电流互感器接入的电能表，其标定电流宜不低于电流互感器额定二次电流的（）。",[170,172,174,176],{"key":20,"text":171,"correct":26},"20%；",{"key":24,"text":173,"correct":22},"30%；",{"key":28,"text":175,"correct":26},"40%,",{"key":31,"text":177,"correct":26},"50%。",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":31,"analysis":33},1022416,"为提髙低负荷时的计量准确性： 额定最大电流为额定二次电流的（）。",[182,184,186,188],{"key":20,"text":183,"correct":26},"90%左右；",{"key":24,"text":185,"correct":26},"100%左右；",{"key":28,"text":187,"correct":26},"110%左右；",{"key":31,"text":189,"correct":22},"120%左右。",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":28,"analysis":33},1022417,"单元控制室电气元件的控制、信号、测量和自动装置型式应与单元控制室（）相协调。",[194,196,198,200],{"key":20,"text":195,"correct":26},"暖通设备；",{"key":24,"text":197,"correct":26},"照明设备；",{"key":28,"text":199,"correct":22},"热工仪表和控制；",{"key":31,"text":201,"correct":26},"装修材料。",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":24,"analysis":33},1022418,"当发电机出口装有断路器，并且发电机变压器组髙压侧接线为一个半断路器接线时(髙压侧2台断路器)，该两台断路器的控制地点为（）。",[206,208,210,212],{"key":20,"text":207,"correct":26},"单元控制室机组DCS；",{"key":24,"text":209,"correct":22},"单元控制室机组DCS和网络监控系统；",{"key":28,"text":211,"correct":26},"配电装里附近；",{"key":31,"text":213,"correct":26},"网络继电器室，",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":28,"analysis":33},1022419,"发电厂6kV或10kV和变电所10kV屋内配电装置到用户去的线路、供辅助车间用的厂用变压器、交流事故保安电源、交流不停电电源等，其控制地点宜为（）。",[218,220,222,224],{"key":20,"text":219,"correct":26},"远方控制；",{"key":24,"text":221,"correct":26},"就地控制；",{"key":28,"text":223,"correct":22},"远方控制和就地控制；",{"key":31,"text":225,"correct":26},"其他。",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":28,"analysis":33},1022420,"二次接线系统的工作电压一般不超过（）。",[230,232,234,236],{"key":20,"text":231,"correct":26},"220V；",{"key":24,"text":233,"correct":26},"380V；",{"key":28,"text":235,"correct":22},"500V；",{"key":31,"text":237,"correct":26},"660V。",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":31,"analysis":33},1022421,"35~110kV无人值班变电所，不宜在远方控制端控制的设备是（）。",[242,244,246,248],{"key":20,"text":243,"correct":26},"6~110kV线路、主变压器、母线和电容器的断路器；",{"key":24,"text":245,"correct":26},"需要炅活改变运行方式的主变压器中性点接地隔离开关；",{"key":28,"text":247,"correct":26},"主变压器有载调压分接开关,",{"key":31,"text":249,"correct":22},"35、110kV配电装置隔离开关，",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":31,"analysis":33},1022422,"下列电压互感器接线方式中错误的是（)?",[254,256,258,260],{"key":20,"text":255,"correct":26},"电压互感器二次回路中，除接成开口三角形的剩余二次绕组和另有规定者外，应在其出口装设熔断器或自动开关；",{"key":24,"text":257,"correct":26},"0.2级电能表电压回路，宜由电压互感器出线端装设单独熔断器或自动开关；",{"key":28,"text":259,"correct":26},"电压互感器二次例采用B相接地方式时，B相熔断器或自动开关应接在绕组出线端与接地点之间；",{"key":31,"text":261,"correct":22},"电压互感器接成开口三角的剩余二次绕组的试验芯出线端，不应装设熔断器或自动开关。",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":28,"analysis":33},1022423,"发电广和变电所应采用铜芯控制电缆和绝缘导线，按机械强度要求，强电控制回路导体截面应不小于（）。",[266,268,270,272],{"key":20,"text":267,"correct":26},"0.5mm2；",{"key":24,"text":269,"correct":26},"1.Omm2；",{"key":28,"text":271,"correct":22},"1.5mm2；",{"key":31,"text":273,"correct":26},"2.5mm2。",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":20,"analysis":33},1022424,"发电厂和变电所应采用铜芯控制电缆和绝缘导线，按机械强度要求，弱电控制回路导体截面应不小于（）。",[278,279,280,281],{"key":20,"text":267,"correct":22},{"key":24,"text":269,"correct":26},{"key":28,"text":271,"correct":26},{"key":31,"text":273,"correct":26},{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":31,"analysis":33},1022425,"电测量指示性仪表用电压互感器二次回路电缆的电压降应不大于额定二次电压的（）。",[286,288,290,292],{"key":20,"text":287,"correct":26},"0.25%~0.5%；",{"key":24,"text":289,"correct":26},"0.5%~1%",{"key":28,"text":291,"correct":26},"1%~2%；",{"key":31,"text":293,"correct":22},"~3%。",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":20,"analysis":33},1022426,"电能量计费用电压互感器二次回路电缆压降应不夫于额定二次电压的（）。",[298,300,302,304],{"key":20,"text":299,"correct":22},"0.25%；",{"key":24,"text":301,"correct":26},"0.5%；",{"key":28,"text":303,"correct":26},"1%；",{"key":31,"text":305,"correct":26},"3%。",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":24,"analysis":33},1022427,"电力系统内部的考核用0.5级电能表的电压互感器二次回路电缆的电压降可适当放宽，但应不大于额定二次电压的（）。",[310,311,312,313],{"key":20,"text":299,"correct":26},{"key":24,"text":301,"correct":22},{"key":28,"text":303,"correct":26},{"key":31,"text":305,"correct":26},{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":31,"analysis":33},1022428,"控制电缆宜采用多芯电缆，应尽可能减少电缆根数，当芯线截面为1.5mm2时，电缆芯数不宜超过（）。",[318,320,322,324],{"key":20,"text":319,"correct":26},"10；",{"key":24,"text":321,"correct":26},"19；",{"key":28,"text":323,"correct":26},"24；",{"key":31,"text":325,"correct":22},"37。",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":28,"analysis":33},1022429,"控制电缆宜采用多芯电缆，应尽可能减少电缆根数，当芯线截面为2.5mm2时，电缆芯数不宜超过（）。",[330,331,332,333],{"key":20,"text":319,"correct":26},{"key":24,"text":321,"correct":26},{"key":28,"text":323,"correct":22},{"key":31,"text":334,"correct":26},"37.",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":20,"analysis":33},1022430,"控制电缆宜采用多芯电缆，应尽可能减少电缆根数，当芯线截面为4mm2时，电缆芯数不宜超过（）.",[339,340,341,342],{"key":20,"text":319,"correct":22},{"key":24,"text":321,"correct":26},{"key":28,"text":323,"correct":26},{"key":31,"text":325,"correct":26},{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":24,"analysis":33},1022431,"“五防”闭锁功能指（）。",[347,349,351,353],{"key":20,"text":348,"correct":26},"防止带负荷拉（合）隔离开关，防止误拉（合）断路器，防止带电挂地线，防止带地线合闸，防止带电调整变压器有载分接开关；",{"key":24,"text":350,"correct":22},"防止带负荷拉（合）隔离开关，防止误拉（合）断路器，防止带电挂地线，防止带地线合闸，防止误入有电间隔；",{"key":28,"text":352,"correct":26},"防止带负荷拉（合）隔离开关，防止误入有电间隔，防止带电挂地线，防止带地线合闸，防止带电调整变压器有载分接开关；",{"key":31,"text":354,"correct":26},"防止带负荷拉（合）隔离开关，防止误拉（合）断路器，防止带电挂地线，防止误入有电间隔，防止带电调整变压器有载分接开关。",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":28,"analysis":33},1022432,"指针式交流仪表、指针式直流仪表的准确度最低要求为（）。",[359,361,363,365],{"key":20,"text":360,"correct":26},"0.5级；",{"key":24,"text":362,"correct":26},"1.0级；",{"key":28,"text":364,"correct":22},"1.5级；",{"key":31,"text":366,"correct":26},"2.5级。",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":20,"analysis":33},1022433,"数字式仪表的准确度最低要求为（）。",[371,372,373,374],{"key":20,"text":360,"correct":22},{"key":24,"text":362,"correct":26},{"key":28,"text":364,"correct":26},{"key":31,"text":375,"correct":26},"2.5级，",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":20,"analysis":33},1022434,"当仪表准确度等级为0.5级时，相应的电流和电压互感器、变送器、分流器的最低准确度为（）。",[380,381,382,384],{"key":20,"text":360,"correct":22},{"key":24,"text":362,"correct":26},{"key":28,"text":383,"correct":26},"1.5级",{"key":31,"text":375,"correct":26},{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":28,"analysis":33},1022435,"指针式测量仪表的测量范围，宜使电力设备额定值指示在仪表标度尺的（）。",[389,391,393,395],{"key":20,"text":390,"correct":26},"1\u002F2左右；",{"key":24,"text":392,"correct":26},"1\u002F3左右；",{"key":28,"text":394,"correct":22},"2\u002F3左右；",{"key":31,"text":396,"correct":26},"100%左右。",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":24,"analysis":33},1022436,"I、II类电能计量装置准确度最低要求为有功电能表（），无功电能表（），电压互感器（），电流互感器（）。",[401,403,405,407],{"key":20,"text":402,"correct":26},"0.2S或0.2级、2.0级、0.2级、0.2S或0.2级；",{"key":24,"text":404,"correct":22},"0.5S或0.5级、2.0级、0.2级、0.23或0.2级；",{"key":28,"text":406,"correct":26},"0.5S或0.5级、2.0级、0.5级、0.5S或0.5级；",{"key":31,"text":408,"correct":26},"0.5S或0.5级、1.0级、0.2级、0.2S或0.2级。",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":24,"analysis":33},1022437,"在离控制屏（屏台）（）远处的地面上应饰有警戒线。",[413,415,417,419],{"key":20,"text":414,"correct":26},"600mm；",{"key":24,"text":416,"correct":22},"800mm；",{"key":28,"text":418,"correct":26},"1000mm；",{"key":31,"text":420,"correct":26},"1200mm?",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":28,"analysis":33},1022438,"800mm宽的控制屏上，每行控制开关的数量不宜超过（）。",[425,427,429,431],{"key":20,"text":426,"correct":26},"3个B；",{"key":24,"text":428,"correct":26},"4个；",{"key":28,"text":430,"correct":22},"5个；",{"key":31,"text":432,"correct":26},"6个。",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":31,"analysis":33},1022439,"由单个继电器构成的继电器屏，各类继电器宜按由上至下的布置顺序为（）。",[437,439,441,443],{"key":20,"text":438,"correct":26},"时间继电器、中间继电器、电压继电器、电流继电器；",{"key":24,"text":440,"correct":26},"电流继电器、时间继电器、电压继电器、中间继电器；",{"key":28,"text":442,"correct":26},"电压继电器、电流继电器、时间继电器、中间继电器；",{"key":31,"text":444,"correct":22},"电流继电器、电压继电器、中间继电器、时间继电器。",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":24,"analysis":33},1022440,"800mm宽的控制屏上，经常操作的设备宜布置在离地面（）的范围内。",[449,451,453,455],{"key":20,"text":450,"correct":26},"600~1600mm；",{"key":24,"text":452,"correct":22},"800~1500mm；",{"key":28,"text":454,"correct":26},"1000~1600mm；",{"key":31,"text":456,"correct":26},"1000~1800mm。",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":31,"analysis":33},1022441,"信号继电器在屏上的布置高度不宜低于（）。",[461,463,464,466],{"key":20,"text":462,"correct":26},"900mm；",{"key":24,"text":416,"correct":26},{"key":28,"text":465,"correct":26},"700mm；",{"key":31,"text":467,"correct":22},"600mm。",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":28,"analysis":33},1022442,"对控制屏台分开的结构，正确的布置方式是（）。",[472,474,476,478],{"key":20,"text":473,"correct":26},"经常监视的常测仪表、操作设备宜布置在屏上；",{"key":24,"text":475,"correct":26},"一般常测仪表及光字牌宜布里在台上；",{"key":28,"text":477,"correct":22},"测量仪表宜布置在屏台电气主接线模拟线上；",{"key":31,"text":479,"correct":26},"操作设备的布里可以不与其安装单位的模拟接线相对应。",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":24,"analysis":33},1022443,"中央控制室主要通道的最小尺寸为（）。",[484,486,488,490],{"key":20,"text":485,"correct":26},"1200mm；",{"key":24,"text":487,"correct":22},"1400mm；",{"key":28,"text":489,"correct":26},"1600mms；",{"key":31,"text":491,"correct":26},"1800mm。",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":20,"analysis":33},1022444,"控制屏上测量仪表的最低位置不宜小于（）。",[496,498,500,502],{"key":20,"text":497,"correct":22},"1500mm；",{"key":24,"text":499,"correct":26},"1600mm；",{"key":28,"text":501,"correct":26},"1700mm；",{"key":31,"text":491,"correct":26},{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":24,"analysis":33},1022445,"继电器屏上试验部件与连接片的安装中心线离地面不宜低于（）。",[507,509,511,513],{"key":20,"text":508,"correct":26},"200mm；",{"key":24,"text":510,"correct":22},"300mm；",{"key":28,"text":512,"correct":26},"400mm；",{"key":31,"text":514,"correct":26},"500mm。",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":24,"analysis":33},1022446,"( )及以上电压的电流互感器的额定二次电流宜选1A。",[519,520,521,523],{"key":20,"text":41,"correct":26},{"key":24,"text":39,"correct":22},{"key":28,"text":522,"correct":26},"220kV；",{"key":31,"text":524,"correct":26},"500kV。",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":24,"analysis":33},1022447,"对中性点非直接接地系统的电压互感器，需要检査和监视一次回路单相接地时，应选用三相五柱或三个单相式电压互感器，其剩余绕组额定电压应为（）。",[529,531,533,535],{"key":20,"text":530,"correct":26},"10OV；",{"key":24,"text":532,"correct":22},"100\u002F3V；",{"key":28,"text":534,"correct":26},"3X10OV；",{"key":31,"text":536,"correct":26},"57.7V。",{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":20,"analysis":33},1022448,"中性点直接接地系统，电压互感器剩余绕组额定电压应为（）。",[541,542,543,544],{"key":20,"text":530,"correct":22},{"key":24,"text":532,"correct":26},{"key":28,"text":534,"correct":26},{"key":31,"text":545,"correct":26},"57.7V,",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":31,"analysis":33},1022449,"500kV配电装置一个半断路器接线的线路变压器串，其安装单位的划分宜为（）。",[550,552,554,555],{"key":20,"text":551,"correct":26},"2个；",{"key":24,"text":553,"correct":26},"3个；",{"key":28,"text":428,"correct":26},{"key":31,"text":556,"correct":22},"5个。",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":31,"analysis":33},1022450,"()电压等级的隔离开关宜就地控制。",[561,563,565,566],{"key":20,"text":562,"correct":26},"500kV；",{"key":24,"text":564,"correct":26},"330kV；",{"key":28,"text":522,"correct":26},{"key":31,"text":567,"correct":22},"11OkV。",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":24,"analysis":33},1022451,"中央信号装置的有些预告信号（如电压回路断线、断路器三相位置不一致等)，为避免可能瞬间误发信号，应设置（）的延时动作时间。",[572,574,576,578],{"key":20,"text":573,"correct":26},"0.1~0.3s；",{"key":24,"text":575,"correct":22},"0.3~0.5s；",{"key":28,"text":577,"correct":26},"0.5~1s；",{"key":31,"text":579,"correct":26},"1~2s。",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":31,"analysis":33},1022452,"装有电子装置的戽柜，应设有供公用零电位基准点逻辑接地的总接地板。总接地板铜排的截面应不小于（）。",[584,586,588,590],{"key":20,"text":585,"correct":26},"50mm2；",{"key":24,"text":587,"correct":26},"60mm2；",{"key":28,"text":589,"correct":26},"80mm2；",{"key":31,"text":591,"correct":22},"10Omm2。",[593,596,599,602,605,608],{"id":15,"name":594,"category":7,"favorite":595},"领导干部任职前廉政法规知识测试题",92,{"id":597,"name":598,"category":7,"favorite":15},595,"建筑结构与设备",{"id":600,"name":601,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":603,"name":604,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":606,"name":607,"category":7,"favorite":8},534,"BIM工程师",{"id":609,"name":607,"category":7,"favorite":8},535]