[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-13":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":594},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,13,50,2670,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,237,249,261,273,285,297,309,321,333,345,357,369,381,393,405,416,428,436,446,454,462,471,479,491,503,511,522,534,546,558,570,582],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1022353,1,"单选题","在有效接地及低电阻接地系统中，校验发电厂、变电站电气装置中接地网导体截面热稳定时，不同材料（钢、铜、铝）接地网的短时温度是不同的。校验不接地、经消弧线围接地和高电阻接地系统中电气设备接地线热稳定时，敷设在地上与地下的接地线的长时间温度值也是不同的，请按下列不同情况确定接地网的短时温度。 不接地、经消弧线圈接地和高电阻接地系统，敷设在地上接地线的长时间温度不大于（）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","120℃；",false,{"key":24,"text":25,"correct":22},"B","135℃;",{"key":27,"text":28,"correct":22},"C","142℃；",{"key":30,"text":31,"correct":32},"D","150℃。",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},1022354,"在有效接地及低电阻接地系统中，校验发电厂、变电站电气装置中接地网导体截面热稳定时，不同材料（钢、铜、铝）接地网的短时温度是不同的。校验不接地、经消弧线围接地和高电阻接地系统中电气设备接地线热稳定时，敷设在地上与地下的接地线的长时间温度值也是不同的，请按下列不同情况确定接地网的短时温度。 不接地、经消弧线圈接地和高电阻接地系统，敷设在地下接地线的长时间温度不大于（）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"70℃；",{"key":24,"text":41,"correct":22},"85℃；",{"key":27,"text":43,"correct":32},"1OO℃；",{"key":30,"text":45,"correct":22},"120℃。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1022355,"在有效接地及低电阻接地系统中，校验发电厂、变电站电气装置中接地网导体截面热稳定时，不同材料（钢、铜、铝）接地网的短时温度是不同的。校验不接地、经消弧线围接地和高电阻接地系统中电气设备接地线热稳定时，敷设在地上与地下的接地线的长时间温度值也是不同的，请按下列不同情况确定接地网的短时温度。 有效接地、低电阻接地系统，钢、铜、铝材料的接地线的短时温度不大于（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"350℃、400℃、265℃；",{"key":24,"text":53,"correct":32},"400℃、450℃、300℃；",{"key":27,"text":55,"correct":22},"450℃、500℃、320℃；",{"key":30,"text":57,"correct":22},"500℃、550℃、350℃。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},1022356,"某发电厂配电装置的接地装置，接地网的接地电阻计算值为0. 2020;计算用的入地短路电流采用值为9.122kA,最大接触电位差系数的计算值为0.22；最大跨步电位差系数的计算值为0.108.据此，请计算最大接触电位差和最大跨步电位差. 短路时接地装置的电位Ug是（）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"1050V;",{"key":24,"text":65,"correct":32},"1843V；",{"key":27,"text":67,"correct":22},"2037V;",{"key":30,"text":69,"correct":22},"2415V。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":27,"analysis":33},1022357,"某发电厂配电装置的接地装置，接地网的接地电阻计算值为0. 2020;计算用的入地短路电流采用值为9.122kA,最大接触电位差系数的计算值为0.22；最大跨步电位差系数的计算值为0.108.据此，请计算最大接触电位差和最大跨步电位差. 接地装置接地网地表面的最大接触电位差为（）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"286V；",{"key":24,"text":77,"correct":22},"312V；",{"key":27,"text":79,"correct":32},"405V；",{"key":30,"text":81,"correct":22},"534V。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":30,"analysis":33},1022358,"某发电厂配电装置的接地装置，接地网的接地电阻计算值为0. 2020;计算用的入地短路电流采用值为9.122kA,最大接触电位差系数的计算值为0.22；最大跨步电位差系数的计算值为0.108.据此，请计算最大接触电位差和最大跨步电位差. 接地装置接地网外地表面的最大跨步电位差为（）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"158V,",{"key":24,"text":89,"correct":22},"175V；",{"key":27,"text":91,"correct":22},"180V；",{"key":30,"text":93,"correct":32},"199V。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":30,"analysis":33},1022359,"现已知某变电站接地网的均压带为不等间距布置，地网导体等效直径d=0.03m;沿长宽方向布置的均压带根数n1=15，n2=6；接地网的长度和宽度L1=323.5m，L2=170m;水平均压带埋设深度h=0.8m;地网的网孔数m=（n1—1）（n2-1）=14X5=70。请计算各有关相关系数和最大跨步电位差系数。 相关系数Ktd, Kth,KtL,K'max和Kts分别为（选择一组最接近的计算值）（）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"2.301、0.673、0.202、0.015、10.027和1.068;",{"key":24,"text":101,"correct":22},"3.340、0.368、0.316、0.026、12.036和2.071;",{"key":27,"text":103,"correct":22},"2.375、0.741、0.335、0.112、15.0713和1.146,",{"key":30,"text":105,"correct":32},"1.337、0.166、0.169、16.968、0.105和1.658。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},1022360,"现已知某变电站接地网的均压带为不等间距布置，地网导体等效直径d=0.03m;沿长宽方向布置的均压带根数n1=15，n2=6；接地网的长度和宽度L1=323.5m，L2=170m;水平均压带埋设深度h=0.8m;地网的网孔数m=（n1—1）（n2-1）=14X5=70。请计算各有关相关系数和最大跨步电位差系数。 最大接触电位差系数Ktmax的计算值是（）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"0.086；",{"key":24,"text":113,"correct":32},"0.111;",{"key":27,"text":115,"correct":22},"0.165；",{"key":30,"text":117,"correct":22},"1.131。",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":27,"analysis":33},1022361,"A类电气装置是指（）.",[122,124,126,128],{"key":20,"text":123,"correct":22},"220kV及以下发电、变电、送电和配电电气装里；",{"key":24,"text":125,"correct":22},"220kV及以上发电、变电、送电和配电电气装里；",{"key":27,"text":127,"correct":32},"500kV及以下发电、变电、送电和配电电气装里；",{"key":30,"text":129,"correct":22},"500kV及以上发电、变电、送电和配电电气装置。",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},1022362,"工作接地是指（）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"在电气设备捡修时，工人采取的临时接地；",{"key":24,"text":137,"correct":32},"在电力系统电气装里中，为运行需要所设的接地；",{"key":27,"text":139,"correct":22},"电气装里的金属外壳、配电装置的构架和线路杆塔等，由于绝缘损坏有可能带电为防止其危及人身和设备安全而设的接地；",{"key":30,"text":141,"correct":22},"为防止静电对易燃油、天然气储雄和管道等的危险作用而设的接地。",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":30,"analysis":33},1022363,"接地装置是指（）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"埋入地中并直接与大地接触的金属导体；",{"key":24,"text":149,"correct":22},"电气装置、设施的接地端子与接地极网连接用的金属导电部分；",{"key":27,"text":151,"correct":22},"垂直接地极；",{"key":30,"text":153,"correct":32},"A与B的总和。",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},1022364,"集中接地装置的作用是（）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"加强对接地短路电流的散流作用，降低接触电势和跨步电势；",{"key":24,"text":161,"correct":32},"加强对雷电流的散流作用降低对地电位；",{"key":27,"text":163,"correct":22},"A和B;",{"key":30,"text":165,"correct":22},"降低接地电阻。",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":30,"analysis":33},1022365,"接地电阻是指（）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"接地极或自然接地极的对地电阻；",{"key":24,"text":173,"correct":22},"接地网的对地电阻；",{"key":27,"text":175,"correct":22},"接地装置的对地电阻；",{"key":30,"text":177,"correct":32},"接地极或自然接地极的对地电阻和接地线电阻的总和。",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":30,"analysis":33},1022366,"接触电位差是指（）。",[182,184,186,188],{"key":20,"text":183,"correct":22},"接地短路电流流过接地装里，在人接触设备外壳或构架时，在人体手和脚间的电位差；",{"key":24,"text":185,"correct":22},"接地短路电流流过接地装里时，在地面上离设备水平距离0.8m处与设备外壳或架构间的电位差；",{"key":27,"text":187,"correct":22},"C接地短路电流流过接地装置时，在地面上离设备水平距离0.8m处与墙壁离地面的全直距离1.8m处两点间的电位差；",{"key":30,"text":189,"correct":32},"接地短路电流流过接地装里时，在地面上离设备水平距离0.8m处与设备外壳、架构或墻壁离地面的垂直距离1.8m处两点间的电位差。",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":20,"analysis":33},1022367,"跨步电位差是指（）。",[194,196,198,200],{"key":20,"text":195,"correct":32},"接地短路电流流过接地装置时，地面上水平距离为0.8m的两点间的电位差；",{"key":24,"text":197,"correct":22},"接地短路电流流过接地装置时，接地网外的地面上水平距离0.8m处对接地网边沿接地极的电位差；",{"key":27,"text":199,"correct":22},"接地短路电流流过接地装置时，人体两脚间的电位差；",{"key":30,"text":201,"correct":22},"接地短路电流波过接地装里，且人体跨于接地网外与接地网间时两脚间的电位差。",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":20,"analysis":33},1022368,"按用途分类有4种接地，下面有一种接地是不属于按用途分类（）。",[206,208,210,212],{"key":20,"text":207,"correct":32},"主变压器中性点接地；",{"key":24,"text":209,"correct":22},"防静电接地；",{"key":27,"text":211,"correct":22},"工作（系统）接地；",{"key":30,"text":213,"correct":22},"保护接地。",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":30,"analysis":33},1022369,"发电厂和变电站有爆炸危险且爆炸后可能波及主设备或严重影响发供电的建（构）筑物，防雷电感应的接地电阻不应大于（）。",[218,220,222,224],{"key":20,"text":219,"correct":22},"5Ω;",{"key":24,"text":221,"correct":22},"10Ω；",{"key":27,"text":223,"correct":22},"15Ω；",{"key":30,"text":225,"correct":32},"30Ω。",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":24,"analysis":33},1022370,"工作于不接地、经消弧线圈接地和高电阻接地系统的向B类电气装置供电的配电装置，它与B类电气装置系统电源接地点共用接地装置。当配电变压器安装在由其供电的建筑物内时，其接地电阻不宜大于（）。",[230,232,234,235],{"key":20,"text":231,"correct":22},"1.5Ω;",{"key":24,"text":233,"correct":32},"4Ω;",{"key":27,"text":219,"correct":22},{"key":30,"text":236,"correct":22},"10Ω。",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":24,"analysis":33},1022371,"在发电厂中，对铁路轨道和管道防静电接地的接地位置、接地线、接地极布置方式等都提出了明确的要求.下面要求不正确的是（）。",[241,243,245,247],{"key":20,"text":242,"correct":22},"铁路机道、管道及金属桥台，应在其始端、末端、分支处以及每隔50m处设防静电接地；",{"key":24,"text":244,"correct":32},"厂区内的铁路应在两处用绝缘装置与外部轨道隔离，两处绝缘装置间的距离应小于一列火车的长度；",{"key":27,"text":246,"correct":22},"净距小于1OOmm的平行或交叉管道，应每隔20m用金属线跨接；",{"key":30,"text":248,"correct":22},"不能保持良好电气接触的阀门、法兰、弯头等管道连接处也应跨接，跨接线可采用直径不小于8mm的圆钢。",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":30,"analysis":33},1022372,"当发电厂、变电站配电装置架构不允许与避雷线直接相连时，其接地网应在地下与避雷线的接地装置相连接，连接线埋在地中的长度不应（）。",[253,255,257,259],{"key":20,"text":254,"correct":22},"大于5m;",{"key":24,"text":256,"correct":22},"大于10m;",{"key":27,"text":258,"correct":22},"小于10m;",{"key":30,"text":260,"correct":32},"小于15m。",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":20,"analysis":33},1022373,"下列装置中不需采用专门敷设接地线接地的部位是（）。",[265,267,269,271],{"key":20,"text":266,"correct":32},"1OkV及以下钢筋混凝土构件支座上电气设备的金属外壳",{"key":24,"text":268,"correct":22},"发电机机座或外壳；",{"key":27,"text":270,"correct":22},"避雷器，避雷针、线等的接地端子；",{"key":30,"text":272,"correct":22},"变压器及GIS的接地端子。",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":27,"analysis":33},1022374,"在有效接地系统及低电阻接地系统中，电气设备接地线的截面，应按接地短路电流进行热稳定校验。在一般工程中多采用钢作接地线。钢接地线的短时温度不应超过（）。",[277,279,281,283],{"key":20,"text":278,"correct":22},"3OO℃；",{"key":24,"text":280,"correct":22},"350℃；",{"key":27,"text":282,"correct":32},"400℃；",{"key":30,"text":284,"correct":22},"450℃。",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":20,"analysis":33},1022375,"在B类电气装置的接地装置的等电位连接接线时，以下不是标准要求的措施是（）。",[289,291,293,295],{"key":20,"text":290,"correct":32},"应采取防止杂散电流的绝缘措施；",{"key":24,"text":292,"correct":22},"等电位连接主母线的最小截面应不小于装置最大保护线截面的一半，并不应小于6mm2，当采用铜线时，其截面不宜大于25mm2;",{"key":27,"text":294,"correct":22},"连接两个外露导电部分的辅助等电位连接线，其截面不应小于接至该两个外露导电部分的较小保护线的截面；",{"key":30,"text":296,"correct":22},"当建筑物的水管被用作接地线或保护线时，水表必须跨接连接，其连接线的截面应根据其功能要求而采用适当的截面。",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":24,"analysis":33},1022376,"在接地线引进建筑物的入口处应设标志。明敷的接地线表面应涂15~1OOmm宽度相等的专用颜色的条纹来表示。下面正确的是（）。",[301,303,305,307],{"key":20,"text":302,"correct":22},"黄色条纹；",{"key":24,"text":304,"correct":32},"绿色和黄色相间的条纹；",{"key":27,"text":306,"correct":22},"红色和绿色相间的条纹；",{"key":30,"text":308,"correct":22},"黄色和红色相间的条纹。",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":30,"analysis":33},1022377,"高压架空线路杆塔的接地装置一般根据土壤电阻率P的大小而采用不同的型式。现已知某线路杆塔是在土壤电阻率为1OOΩ?m＜ρ≤300Ω?m的地区，其接地装置可采用的型式是（）。",[313,315,317,319],{"key":20,"text":314,"correct":22},"利用铁塔和钢筋混凝土杆自然接地；",{"key":24,"text":316,"correct":22},"人工接地装里采用放射形，且接地极埋设深度不宜小于0.5m;",{"key":27,"text":318,"correct":22},"人工接地装I囷绕杆塔基硇敷设成闭合环形，且接地极埋设深度不宜小于0.3m;",{"key":30,"text":320,"correct":32},"人工接地装里采用水平敷设，且接地极埋设深度不宜小于0.6m。",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":27,"analysis":33},1022378,"接地装置根据热稳定条件，接地线的最小截面应按有关计算公式的要求进行计算。当继电保护装置有两套速动主保护、近接地后备保护、断路器失灵保护和自动重合闸时，短路的等效持续时间“的取值正确的是（）。",[325,327,329,331],{"key":20,"text":326,"correct":22},"主保护动作时间；",{"key":24,"text":328,"correct":22},"主保护动作时间+断路器动作时间；",{"key":27,"text":330,"correct":32},"断路器失灵保护时间+主保护动作时间+断路器动作时间；",{"key":30,"text":332,"correct":22},"自动重合闸时间+断路器失灵保护时间+主保护动作时间+断路器动作时间。",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":30,"analysis":33},1022379,"现已知继电保护装置配有一套速动主保护、远近结合的后备保护和自动重合闸，并有断路器失灵保护时，根据热稳定条件，接地线的最小截面的有关计算公式中 的取值应不小于下面的（）。",[337,339,341,343],{"key":20,"text":338,"correct":22},"主保护动作时间+断路器开断时间；",{"key":24,"text":340,"correct":22},"A+断路器失灵保护动作时间；",{"key":27,"text":342,"correct":22},"A+第一级后备保护的动作时间；",{"key":30,"text":344,"correct":32},"第一级后备保护的动作时间+断路器开断时间。",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":24,"analysis":33},1022380,"根据热稳定条件’在未考虑腐蚀时’接地装置接地极的截面Sj与连接至该接地装置的接地线截面Sx之间的关系是，Sj不宜小于Sx的（）。",[349,351,353,355],{"key":20,"text":350,"correct":22},"65%；",{"key":24,"text":352,"correct":32},"75%；",{"key":27,"text":354,"correct":22},"80%；",{"key":30,"text":356,"correct":22},"85%。",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":24,"analysis":33},1022381,"低压系统由单独的低压电源供电时，其电源接地点接地装置的接地电阻一般不宜超过（）。",[361,363,365,367],{"key":20,"text":362,"correct":22},"2.5Ω；",{"key":24,"text":364,"correct":32},"4.0Ω；",{"key":27,"text":366,"correct":22},"5.OΩ；",{"key":30,"text":368,"correct":22},"8.0Ω。",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":30,"analysis":33},1022382,"接户线的绝缘子在年平均雷暴日数不超过30、低压线被建筑物等屏蔽的地区或接户线距低压线路接地点不超过（）时，绝缘子铁脚可不接地。",[373,375,377,379],{"key":20,"text":374,"correct":22},"15m；",{"key":24,"text":376,"correct":22},"30m;",{"key":27,"text":378,"correct":22},"45m；",{"key":30,"text":380,"correct":32},"50m。",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":27,"analysis":33},1022383,"B类电气装置的接地装置接地线的最小截面除应满足有关公式计算值外，埋入土壤内没有腐蚀保护的接地线，其最小截面按规定应符合（）。",[385,387,389,391],{"key":20,"text":386,"correct":22},"铜1Omm2；钢16mm2；",{"key":24,"text":388,"correct":22},"铜16mm2；钢25mm2；",{"key":27,"text":390,"correct":32},"铜25mm2；钢50mm2；",{"key":30,"text":392,"correct":22},"铜35mm2;钢70mm2。",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":24,"analysis":33},1022384,"B类电气装置瞧装置，非供电电缆或电缆外护物组成細每根保护线，在无机械保护时，面不应小于（）。",[397,399,401,403],{"key":20,"text":398,"correct":22},"2.5mm2；",{"key":24,"text":400,"correct":32},"4.Omm2；",{"key":27,"text":402,"correct":22},"6.0mm2;",{"key":30,"text":404,"correct":22},"10.Omm2。",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":27,"analysis":33},1022385,"B类电气装置的接地装置中，等电位连接主母线的最小截面应不小于装置最大保护线截面的一半，并不应小于（）。",[409,410,412,414],{"key":20,"text":398,"correct":22},{"key":24,"text":411,"correct":22},"4mm2；",{"key":27,"text":413,"correct":32},"6mm2；",{"key":30,"text":415,"correct":22},"1Omm2。",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":24,"analysis":33},1022386,"接触电位差是指接地故障电流流过接地装置时，在地面上离设备水平距离为（）处与设备外壳、架构或墙壁离地面的垂直距离为（）处两点间的电位差。",[420,422,424,426],{"key":20,"text":421,"correct":22},"0.6m、1.5m；",{"key":24,"text":423,"correct":32},"0.8m、1.8m;",{"key":27,"text":425,"correct":22},"1.0m、2.Om;",{"key":30,"text":427,"correct":22},"1.2m、2.5m。",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":20,"analysis":33},1022387,"有效接地和低电阻接地系统中发电厂、变电站电气装置保护接地的接地电阻R应符合（）。 注：I为计算用的淹经接地装置的入地短路电流。",[432,433,434,435],{"key":20,"text":20,"correct":32},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":22},{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":24,"analysis":33},1022388,"有效接地和低电阻接地系统中发电厂、变电站电气装置保护接地的接地电阻R不得大于（）。",[440,441,443,445],{"key":20,"text":221,"correct":22},{"key":24,"text":442,"correct":32},"5Ω；",{"key":27,"text":444,"correct":22},"4Ω；",{"key":30,"text":225,"correct":22},{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":30,"analysis":33},1022389,"发电厂的易燃油和天然气设施防静电接地的接地电阻不应大于（）。",[450,451,452,453],{"key":20,"text":221,"correct":22},{"key":24,"text":442,"correct":22},{"key":27,"text":444,"correct":22},{"key":30,"text":225,"correct":32},{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":20,"analysis":33},1022390,"在土壤电阻率不大于500Ω·m的地区，独立避雷针的接地电阻不应大于（）。",[458,459,460,461],{"key":20,"text":221,"correct":32},{"key":24,"text":442,"correct":22},{"key":27,"text":444,"correct":22},{"key":30,"text":225,"correct":22},{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":30,"analysis":33},1022391,"架空线路杆塔保护接地的接地电阻不宜大于（）。",[466,468,469,470],{"key":20,"text":467,"correct":22},"1OΩ；",{"key":24,"text":442,"correct":22},{"key":27,"text":444,"correct":22},{"key":30,"text":225,"correct":32},{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":20,"analysis":33},1022392,"保护配电柱上断路器、负荷开关和电容器组等的避雷器的接地线应与设备外壳相连，接地装置的接地电阻不应大于（）。",[475,476,477,478],{"key":20,"text":467,"correct":32},{"key":24,"text":219,"correct":22},{"key":27,"text":444,"correct":22},{"key":30,"text":225,"correct":22},{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":30,"analysis":33},1022393,"当不要求采用专门敷设的接地线接地时，下列设施中不能作为电气设备的接地线的是（）。",[483,485,487,489],{"key":20,"text":484,"correct":22},"金属构件；",{"key":24,"text":486,"correct":22},"普通钢筋混疑土构件的钢筋；",{"key":27,"text":488,"correct":22},"穿线的钢管和电缆的金属外皮；",{"key":30,"text":490,"correct":32},"蛇皮管的金属层和保溫管的金属网。",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":30,"analysis":33},1022394,"发电厂、变电站的接地装置应与线路的避雷线连接，当不允许直接连接时，下列作法中正确的是（）。",[495,497,499,501],{"key":20,"text":496,"correct":22},"避雷线设独立的接地装置，接地装里与电气装里接地点的地中距离不小于15m;",{"key":24,"text":498,"correct":22},"避雷线设独立的接地装里，接地电阻不大于10Ω;",{"key":27,"text":500,"correct":22},"避雷线接地装里在地下与接地网相连，连接线埋在地中的长度不小于5m;",{"key":30,"text":502,"correct":32},"避雷线接地装里在地下与接地网相连，连接线埋在地中的长度不小于15m。",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":30,"analysis":33},1022395,"下列回路不需測量频率的是（）。 A.接有发电机变压器組的各段母线；a发电机出口电压； C.有可能解列运行的各段母线； D.高低压厂用电源的各段母线。",[507,508,509,510],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":32},{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":30,"analysis":33},1022396,"流互感器电缆芯线截面宜不小于（）。",[515,517,519,520],{"key":20,"text":516,"correct":22},"1mm2；",{"key":24,"text":518,"correct":22},"2mm2；",{"key":27,"text":398,"correct":22},{"key":30,"text":521,"correct":32},"4mm2。",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":20,"analysis":33},1022397,"准确级为0.5级，一次电流为额定电流的5%，一般测量用电流互感器的误差极限为电流误差（），相位差（）。",[526,528,530,532],{"key":20,"text":527,"correct":32},"±1.5%，±90；",{"key":24,"text":529,"correct":22},"±0.75%，±15；",{"key":27,"text":531,"correct":22},"±0.5%,±45；",{"key":30,"text":533,"correct":22},"±0.35%,±30。",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":20,"analysis":33},1022398,"变电所三绕组（自耦）联络变压器控制屏仪表（监渕），以下不需测量有功、无功功率的是（）。",[538,540,542,544],{"key":20,"text":539,"correct":32},"公共绕组（自耦变压器）；",{"key":24,"text":541,"correct":22},"高压倒；",{"key":27,"text":543,"correct":22},"中压例；",{"key":30,"text":545,"correct":22},"低压侧。",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":20,"analysis":33},1022399,"下列不是常用测量仪表的测量方式的是（）。",[550,552,554,556],{"key":20,"text":551,"correct":32},"间接仪表测责；",{"key":24,"text":553,"correct":22},"直接仪表测量；",{"key":27,"text":555,"correct":22},"C一次仪表測量；",{"key":30,"text":557,"correct":22},"二次仪表測量。",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":24,"analysis":33},1022400,"下列不属于常用测量仪表的是（）。",[562,564,566,568],{"key":20,"text":563,"correct":22},"指针式仪表；",{"key":24,"text":565,"correct":32},"电能表；",{"key":27,"text":567,"correct":22},"数字式仪表；",{"key":30,"text":569,"correct":22},"记录型仪表。",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":27,"analysis":33},1022401,"直流输电线路的直流换流站，不应采集直流电流的回路是（）。",[574,576,578,580],{"key":20,"text":575,"correct":22},"本端的每极直流线路；",{"key":24,"text":577,"correct":22},"本端的地极性回路；",{"key":27,"text":579,"correct":32},"本端的正极性回路；",{"key":30,"text":581,"correct":22},"本端的临时接地间路（投入运行时）。",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":24,"analysis":33},1022402,"电流互感器二次绕组中所接入的负荷（包括测量仪表、电能计量和连接导线等），应保证实际二次负荷在（）范围内。",[586,588,590,592],{"key":20,"text":587,"correct":22},"20%~100%；",{"key":24,"text":589,"correct":32},"25%~100%；",{"key":27,"text":591,"correct":22},"30%~100%；",{"key":30,"text":593,"correct":22},"35%~100%。",[595,598,601,604,607,610],{"id":15,"name":596,"category":7,"favorite":597},"领导干部任职前廉政法规知识测试题",92,{"id":599,"name":600,"category":7,"favorite":15},595,"建筑结构与设备",{"id":602,"name":603,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":605,"name":606,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":608,"name":609,"category":7,"favorite":8},534,"BIM工程师",{"id":611,"name":609,"category":7,"favorite":8},535]