[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-11":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":618},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,11,50,2670,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,310,322,334,346,358,370,382,394,406,417,429,441,451,463,475,486,498,510,522,534,546,558,570,582,594,606],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},1022252,1,"单选题","在绝缘配合标准中，送电线路、变电所绝缘子串及空气间隙的绝缘配合公式均按标准气象条件给出。请在下列各组气象条件数据中，分别确定标准气象条件（气压P、温度T、绝对湿度 H）的有关数据，（1mmHg=133.322Pa） 标准气象条件的温度T等于（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","15℃；",false,{"key":24,"text":25,"correct":26},"B","20℃；",true,{"key":28,"text":29,"correct":22},"C","22℃；",{"key":31,"text":32,"correct":22},"D","25℃；。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},1022253,"在绝缘配合标准中，送电线路、变电所绝缘子串及空气间隙的绝缘配合公式均按标准气象条件给出。请在下列各组气象条件数据中，分别确定标准气象条件（气压P、温度T、绝对湿度 H）的有关数据，（1mmHg=133.322Pa）",[38,40,42,44],{"key":20,"text":39,"correct":22},"标准气象条件的绝对湿度H等于（）。",{"key":24,"text":41,"correct":22},"8.5g\u002Fm3；",{"key":28,"text":43,"correct":22},"9g\u002Fm3; C 10g\u002Fm3；",{"key":31,"text":45,"correct":26},"11g\u002Fm3。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},1022254,"两根等髙独立避雷针，高度为30m，其间距离为45m。 两针间保护范围上部边缘最低点高度为（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"22.5m;",{"key":24,"text":53,"correct":26},"23.5m;",{"key":28,"text":55,"correct":22},"24.5m;",{"key":31,"text":57,"correct":22},"25.5m。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},1022255,"两根等髙独立避雷针，高度为30m，其间距离为45m。 若被保护物髙度为15m,两针间水平面上保护范围的一侧最小宽度为（）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"1Om;",{"key":24,"text":65,"correct":22},"11m；",{"key":28,"text":67,"correct":26},"12m；",{"key":31,"text":69,"correct":22},"13m。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},1022256,"在变电所电气设备与工频电压的配合中，已知对处于I级污秽区的220kV变电所，标准要求设备户外电瓷绝缘的爬电比距应不小于1.60cm\u002FkV。试计算设备户外电瓷绝缘的爬电距离L，并说明I级污移区电气设备爬电比距的取值应不小于1.60cm\u002FkV时的户外电瓷绝缘的瓷件平均直径DM的大小。 设备户外电瓷绝缘的爬电距离L的计算值不小于（）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"384cm;",{"key":24,"text":77,"correct":26},"403cm；",{"key":28,"text":79,"correct":22},"444cm;",{"key":31,"text":81,"correct":22},"484cm。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},1022257,"在变电所电气设备与工频电压的配合中，已知对处于I级污秽区的220kV变电所，标准要求设备户外电瓷绝缘的爬电比距应不小于1.60cm\u002FkV。试计算设备户外电瓷绝缘的爬电距离L，并说明I级污移区电气设备爬电比距的取值应不小于1.60cm\u002FkV时的户外电瓷绝缘的瓷件平均直径DM的大小。 I级污秽区电气设备爬电比距A的取值应不小于1.60cm\u002FkV,是在户外电瓷绝缘的瓷件平均直径DM为（）的条件下规定的。",[86,88,90,92],{"key":20,"text":87,"correct":26},"Dm 3OOmm;",{"key":24,"text":89,"correct":22},"300mm≤Dm≤400mm；",{"key":28,"text":91,"correct":22},"300mm≤Dm≤500mm;",{"key":31,"text":93,"correct":22},"Dm 500mm。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},1022258,"在电气设备耐受电压的选择中，对于110kV的电力变压器、髙压并联电抗器中性点及其接地电抗器耐受电压的选用，应该在分析比较后分别确定其雷电全波和截波耐受电压和短时工频耐受电压值。 雷电全波和截波耐受电压值为（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"185kV;",{"key":24,"text":101,"correct":26},"250kV；",{"key":28,"text":103,"correct":22},"325kV;",{"key":31,"text":105,"correct":22},"400kV。",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},1022259,"在电气设备耐受电压的选择中，对于110kV的电力变压器、髙压并联电抗器中性点及其接地电抗器耐受电压的选用，应该在分析比较后分别确定其雷电全波和截波耐受电压和短时工频耐受电压值。 短时工频耐受电压值为（）。",[110,112,114,116],{"key":20,"text":111,"correct":26},"95kV；",{"key":24,"text":113,"correct":22},"115kV；",{"key":28,"text":115,"correct":22},"125kV；",{"key":31,"text":117,"correct":22},"145kV。",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},1022260,"某发电厂拟采用悬挂高度为29m的两根平行避雷线和一高度也是29m的独立避雷针联合作为髙度为16m设施的防雷保护。现已知两根平行避雷线间距离为24m,长度为46m；-雷针与最近一根避雷线两端的距均是46m,现按有关公式计算、校验此方案的可行性（被保护设施均在避雷线间和避雷线与避雷针间所形成的平行四边形和三角形保护范围内）。 两根平行避雷线端部及外侧的保护范围按单根避雷线的公式计算，其结果是（）.",[122,124,126,128],{"key":20,"text":123,"correct":22},"3.56m;",{"key":24,"text":125,"correct":22},"4.35m；",{"key":28,"text":127,"correct":22},"5.38m;",{"key":31,"text":129,"correct":26},"6.11m,",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":33},1022261,"某发电厂拟采用悬挂高度为29m的两根平行避雷线和一高度也是29m的独立避雷针联合作为髙度为16m设施的防雷保护。现已知两根平行避雷线间距离为24m,长度为46m；-雷针与最近一根避雷线两端的距均是46m,现按有关公式计算、校验此方案的可行性（被保护设施均在避雷线间和避雷线与避雷针间所形成的平行四边形和三角形保护范围内）。 两根平行避雷线间的最小保护宽度是（）。",[134,136,138,140],{"key":20,"text":135,"correct":26},"3.29m；",{"key":24,"text":137,"correct":22},"4.11m;",{"key":28,"text":139,"correct":22},"5.22m；",{"key":31,"text":141,"correct":22},"6.1m。",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},1022262,"某发电厂拟采用悬挂高度为29m的两根平行避雷线和一高度也是29m的独立避雷针联合作为髙度为16m设施的防雷保护。现已知两根平行避雷线间距离为24m,长度为46m；-雷针与最近一根避雷线两端的距均是46m,现按有关公式计算、校验此方案的可行性（被保护设施均在避雷线间和避雷线与避雷针间所形成的平行四边形和三角形保护范围内）。 避雷针的外侧保护范围是（）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"10.5m;",{"key":24,"text":149,"correct":26},"13m；",{"key":28,"text":151,"correct":22},"14.6m;",{"key":31,"text":153,"correct":22},"15.8m。",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":28,"analysis":33},1022263,"某发电厂拟采用悬挂高度为29m的两根平行避雷线和一高度也是29m的独立避雷针联合作为髙度为16m设施的防雷保护。现已知两根平行避雷线间距离为24m,长度为46m；-雷针与最近一根避雷线两端的距均是46m,现按有关公式计算、校验此方案的可行性（被保护设施均在避雷线间和避雷线与避雷针间所形成的平行四边形和三角形保护范围内）。 避雷针、线的联合保护范围是（按等效避雷线计算）：避雷线端部及外侧的保护范围是（）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"4.15m；",{"key":24,"text":161,"correct":22},"5.62m；",{"key":28,"text":163,"correct":26},"6.11m；",{"key":31,"text":165,"correct":22},"6.92m。",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":31,"analysis":33},1022264,"某发电厂拟采用悬挂高度为29m的两根平行避雷线和一高度也是29m的独立避雷针联合作为髙度为16m设施的防雷保护。现已知两根平行避雷线间距离为24m,长度为46m；-雷针与最近一根避雷线两端的距均是46m,现按有关公式计算、校验此方案的可行性（被保护设施均在避雷线间和避雷线与避雷针间所形成的平行四边形和三角形保护范围内）。 校验结果是（）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"被保护设施在两根平行避雷线的保护范围内；",{"key":24,"text":173,"correct":22},"被保护设施在避雷针保护范围内；",{"key":28,"text":175,"correct":22},"C被保护设施超出两跟平行避雷线和避雷针联合的保护范围；",{"key":31,"text":177,"correct":26},"被保护设施全在两根平行避雷线和避雷针的联合保护范围内。",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":28,"analysis":33},1022265,"根据变电所电气设备与工频电压的配合，在一个处于II级污秽区的变电所中，选用550kV电气设备时，当电瓷件平均直径队在300~500cm和Dm大于500cm时，确定设备的户外电瓷绝缘的几何爬电距离L。 当Dm在300~500cm时，爬电距离L不小于（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":22},"1050cm；",{"key":24,"text":185,"correct":22},"1100cm；",{"key":28,"text":187,"correct":26},"1210cm；",{"key":31,"text":189,"correct":22},"1435cm。",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":24,"analysis":33},1022266,"根据变电所电气设备与工频电压的配合，在一个处于II级污秽区的变电所中，选用550kV电气设备时，当电瓷件平均直径队在300~500cm和Dm大于500cm时，确定设备的户外电瓷绝缘的几何爬电距离L。 当Dm大于500cm时，爬电距离L不小于（）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"1215cm；",{"key":24,"text":197,"correct":26},"1320cm；",{"key":28,"text":199,"correct":22},"1430cm；",{"key":31,"text":201,"correct":22},"1540cm。",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":28,"analysis":33},1022267,"单机容量为12000kW的直配电机，在少雷区除按采用标准保护接线外，对于1OkV线路，在进线保护段长度L0内，应装设避雷针（线）。当排气式避雷器的接地电阻R分别是和60时，确定进线保护段长度L0应该满足的要求。 当R=4时，L0应该满足的要求是（）。",[206,208,210,212],{"key":20,"text":207,"correct":22},"L0≥350m;",{"key":24,"text":209,"correct":22},"L0≥480m；",{"key":28,"text":211,"correct":26},"L0≥600m；",{"key":31,"text":213,"correct":22},"L0≥650m.",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":31,"analysis":33},1022268,"单机容量为12000kW的直配电机，在少雷区除按采用标准保护接线外，对于1OkV线路，在进线保护段长度L0内，应装设避雷针（线）。当排气式避雷器的接地电阻R分别是和60时，确定进线保护段长度L0应该满足的要求。 当R=6时，L0应该满足的要求是（ ）。",[218,220,222,224],{"key":20,"text":219,"correct":22},"L0≥750m；",{"key":24,"text":221,"correct":22},"L0≥780m；",{"key":28,"text":223,"correct":22},"L0≥825m；",{"key":31,"text":225,"correct":26},"L0≥900m.",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":28,"analysis":33},1022269,"在雷电过电压下的绝缘配合中，已知某工程选用的550kV避雷器雷电冲击残压Ubnc为1O11kV,操作冲击残压Ubcc为827kV,计算500kv电流互感器的全波額定雷电冲击耐受电压Und值和相对地操作冲击耐受电压Ucz值。 全波额定雷电冲击耐受电压Und值是（）。",[230,232,234,236],{"key":20,"text":231,"correct":22},"1213kV；",{"key":24,"text":233,"correct":22},"1314kV；",{"key":28,"text":235,"correct":26},"1415kV；",{"key":31,"text":237,"correct":22},"1516kV。",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":20,"analysis":33},1022270,"在雷电过电压下的绝缘配合中，已知某工程选用的550kV避雷器雷电冲击残压Ubnc为1O11kV,操作冲击残压Ubcc为827kV,计算500kv电流互感器的全波額定雷电冲击耐受电压Und值和相对地操作冲击耐受电压Ucz值。 相对地操作冲击耐受电压值是（）。",[242,244,246,248],{"key":20,"text":243,"correct":26},"951kV；",{"key":24,"text":245,"correct":22},"976kV；",{"key":28,"text":247,"correct":22},"992kV；",{"key":31,"text":249,"correct":22},"1034kV。",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":31,"analysis":33},1022271,"已知某500kV变电所工程，550kV避雷器操作冲击残压17。为825kV，分别计算出500kV电压互感器、电流互感器的相对地和相间操作冲击耐受电压。",[254,256,258,260],{"key":20,"text":255,"correct":22},"相对地操作冲击耐受电压不小于（ ）。",{"key":24,"text":257,"correct":22},"907.5kV；",{"key":28,"text":259,"correct":22},"924.OkV； C .932.5kV；",{"key":31,"text":261,"correct":26},"948.8kV。",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":28,"analysis":33},1022272,"已知某500kV变电所工程，550kV避雷器操作冲击残压17。为825kV，分别计算出500kV电压互感器、电流互感器的相对地和相间操作冲击耐受电压。 相间操作冲击耐受电压不小于（）。",[266,268,270,272],{"key":20,"text":267,"correct":22},"1043.7kV；",{"key":24,"text":269,"correct":22},"1233.4kV；",{"key":28,"text":271,"correct":26},"1423.2kV;",{"key":31,"text":273,"correct":22},"1518.1kV。",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":31,"analysis":33},1022273,"某变电所高压配电装置电压为220kV,已知所选避雷器型号是W10Y5-200\u002F496，其1OkA雷电冲击残压Ub=496kV。在主变压器与雷电过电压的绝缘配合中，确定变压器的内、外绝缘的额定雷电冲击耐受电压和内绝缘的工频耐受电压。 额定雷电冲击耐受电压值不小于（）。",[278,280,282,284],{"key":20,"text":279,"correct":22},"545.6kV；",{"key":24,"text":281,"correct":22},"595.2kV；",{"key":28,"text":283,"correct":22},"644.8kV；",{"key":31,"text":285,"correct":26},"694.4kV。",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":24,"analysis":33},1022274,"某变电所高压配电装置电压为220kV,已知所选避雷器型号是W10Y5-200\u002F496，其1OkA雷电冲击残压Ub=496kV。在主变压器与雷电过电压的绝缘配合中，确定变压器的内、外绝缘的额定雷电冲击耐受电压和内绝缘的工频耐受电压。 工频耐受电压应该不小于（ ）。",[290,292,294,296],{"key":20,"text":291,"correct":22},"203.7kV；",{"key":24,"text":293,"correct":26},"218.2kV；",{"key":28,"text":295,"correct":22},"232.8kV；",{"key":31,"text":297,"correct":22},"247.3kV。",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":28,"analysis":33},1022275,"超髙压系统合闸空载线路过电压以重合闸的情况最为严重。过电压的幅值受到很多因素的影响，如系统参数、结构及运行方式等。 除上述因素外，影响合闹过电压幅值不包括的因素有（）。",[302,304,306,308],{"key":20,"text":303,"correct":22},"合闸初相位的选择；",{"key":24,"text":305,"correct":22},"三相断路器不同期合闸；",{"key":28,"text":307,"correct":26},"三相断路器的灭孤性能；",{"key":31,"text":309,"correct":22},"线路残压的变化。",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":31,"analysis":33},1022276,"超髙压系统合闸空载线路过电压以重合闸的情况最为严重。过电压的幅值受到很多因素的影响，如系统参数、结构及运行方式等。 限制合闸过电压，不能采用的措施有（）。",[314,316,318,320],{"key":20,"text":315,"correct":22},"合理装设高压并联电抗器；",{"key":24,"text":317,"correct":22},"采用单相自动重合闸；",{"key":28,"text":319,"correct":22},"采用带有合闸并联电阻的断路器；",{"key":31,"text":321,"correct":26},"采用电磁式电压互感器。",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":28,"analysis":33},1022277,"在发电厂220kV配电装置中，已知220kV为有效接地系统，在选择220kV氧化锌避雷器作为雷电过电压保护装置时，相对地的持续运行电压和额定电压主要要求： 相对地持续运行电压要求不低于（）。",[326,328,330,332],{"key":20,"text":327,"correct":22},"0.8Um；",{"key":24,"text":329,"correct":22},"Um；",{"key":28,"text":331,"correct":26},"Um\u002F√3；",{"key":31,"text":333,"correct":22},"√2Um\u002F√3。",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":20,"analysis":33},1022278,"在发电厂220kV配电装置中，已知220kV为有效接地系统，在选择220kV氧化锌避雷器作为雷电过电压保护装置时，相对地的持续运行电压和额定电压主要要求： 相对地的额定电压要求是（ ）。",[338,340,342,344],{"key":20,"text":339,"correct":26},"0.75Um；",{"key":24,"text":341,"correct":22},"1.05Um；",{"key":28,"text":343,"correct":22},"1.25Um；",{"key":31,"text":345,"correct":22},"1.38Um。",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":31,"analysis":33},1022279,"某独立避雷针高度为25m。",[350,352,354,356],{"key":20,"text":351,"correct":22},"若被保护物高度为10m，其保护半径为（）。",{"key":24,"text":353,"correct":22},"13m;",{"key":28,"text":355,"correct":22},"14m; C16m;",{"key":31,"text":357,"correct":26},"17.5m。",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":20,"analysis":33},1022280,"某独立避雷针高度为25m。 若被保护物高度为18m，其保护半径为（）。",[362,364,366,368],{"key":20,"text":363,"correct":26},"7m；",{"key":24,"text":365,"correct":22},"8.5m；",{"key":28,"text":367,"correct":22},"10m；",{"key":31,"text":369,"correct":22},"11m。",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":24,"analysis":33},1022281,"某550kV、750MVA自耦变压器，其空载电流为0.2%，对地电容为5000ρ F，转化系数η为0.45。 该变压器的自由振荡频率为（）。",[374,376,378,380],{"key":20,"text":375,"correct":22},"78.8Hz;",{"key":24,"text":377,"correct":26},"88.8Hz；",{"key":28,"text":379,"correct":22},"98.SHz；",{"key":31,"text":381,"correct":22},"108.8Hz。",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":20,"analysis":33},1022282,"某550kV、750MVA自耦变压器，其空载电流为0.2%，对地电容为5000ρ F，转化系数η为0.45。 若切除该空载变压器，其最大过电压倍数为（）。",[386,388,390,392],{"key":20,"text":387,"correct":26},"1.19;",{"key":24,"text":389,"correct":22},"1.21;",{"key":28,"text":391,"correct":22},"1.23;",{"key":31,"text":393,"correct":22},"1.25,",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":28,"analysis":33},1022283,"某500kV超高压架空线路长度为500km，电磁波的传播速度为3 X105km\u002Fs,系统容量为无穷大。",[398,400,402,404],{"key":20,"text":399,"correct":22},"该线路末端的相位移角为（）。",{"key":24,"text":401,"correct":22},"26°；",{"key":28,"text":403,"correct":26},"28°； C30°；",{"key":31,"text":405,"correct":22},"32°。",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":24,"analysis":33},1022284,"某500kV超高压架空线路长度为500km，电磁波的传播速度为3 X105km\u002Fs,系统容量为无穷大。 线路空载时，末端工频稳态电压是始端电压的（）倍。",[410,412,414,416],{"key":20,"text":411,"correct":22},"1.10;",{"key":24,"text":413,"correct":26},"1.15;",{"key":28,"text":415,"correct":22},"1.20?",{"key":31,"text":393,"correct":22},{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":28,"analysis":33},1022285,"某500kV超高压架空线路长度为400km，电磁波的传播速度为3X105km\u002Fs。系统按有限容量考虑，系统电源阻抗与波阻抗的比值为0.383。",[421,423,425,427],{"key":20,"text":422,"correct":22},"线路空载时，末端工频稳态电压是始端电压E的（）倍。",{"key":24,"text":424,"correct":22},"1.26；",{"key":28,"text":426,"correct":26},"1.29; C1.32；",{"key":31,"text":428,"correct":22},"1.35。",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":28,"analysis":33},1022286,"某500kV超高压架空线路长度为400km，电磁波的传播速度为3X105km\u002Fs。系统按有限容量考虑，系统电源阻抗与波阻抗的比值为0.383。 若在线路末端装设一组髙压并联电抗器，补偿度按60%考虑，此时线路末端工频稳态电压是始端电压E的（）倍。",[433,435,437,439],{"key":20,"text":434,"correct":22},"1.05；",{"key":24,"text":436,"correct":22},"1.07；",{"key":28,"text":438,"correct":26},"1.09；",{"key":31,"text":440,"correct":22},"1.11。",{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":28,"analysis":33},1022287,"某500kV超高压架空线路长度为400km，波阻抗为2600，系统感抗为110Ω。末端装设高压并联电抗器，补偿度按70%考虑。 末端工频稳态电压是始端电压￡的（）倍。",[445,447,448,449],{"key":20,"text":446,"correct":22},"1.03；",{"key":24,"text":434,"correct":22},{"key":28,"text":436,"correct":26},{"key":31,"text":450,"correct":22},"1.09。",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":24,"analysis":33},1022288,"某500kV超高压架空线路长度为400km，波阻抗为2600，系统感抗为110Ω。末端装设高压并联电抗器，补偿度按70%考虑。 该髙压并联电抗器的总容量为（ ）。",[455,457,459,461],{"key":20,"text":456,"correct":22},"275Mvar,",{"key":24,"text":458,"correct":26},"282Mvar；",{"key":28,"text":460,"correct":22},"287Mvar；",{"key":31,"text":462,"correct":22},"295Mvar?",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":24,"analysis":33},1022290,"某500kV超高压架空线路长度为400km，正序波阻抗为260Ω，零序波阻抗为500Ω,正序电源感抗为1OOΩ,零序电源感抗为500,正序波速为3X10 5km\u002Fs,零序波速为2X105km\u002Fs。空载线路末端A相接地。 线路末端健全相的电压相对于正常运行相电压升髙（）倍。",[467,469,471,473],{"key":20,"text":468,"correct":22},"1.45；",{"key":24,"text":470,"correct":26},"1.47,",{"key":28,"text":472,"correct":22},"1.49；",{"key":31,"text":474,"correct":22},"1.51。",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":24,"analysis":33},1022291,"某电厂采用500kV超髙压架空线路送出，线路长度为300km，电源阻抗的标么值为0.25，功率因数为0.85，若其传输功率为线路自然功率的70%。线路故障发生甩负荷情况。 发电机的暂态电势相对于正常运行相电压升髙（）倍。",[479,481,482,484],{"key":20,"text":480,"correct":22},"1.14;",{"key":24,"text":413,"correct":26},{"key":28,"text":483,"correct":22},"1.16；",{"key":31,"text":485,"correct":22},"1.17。",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":31,"analysis":33},1022292,"某电厂采用500kV超髙压架空线路送出，线路长度为300km，电源阻抗的标么值为0.25，功率因数为0.85，若其传输功率为线路自然功率的70%。线路故障发生甩负荷情况。 线路末端电压相对于正常运行相电压升高（）倍。",[490,492,494,496],{"key":20,"text":491,"correct":22},"1.28；",{"key":24,"text":493,"correct":22},"1.30;",{"key":28,"text":495,"correct":22},"1.32；",{"key":31,"text":497,"correct":26},"1.36。",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":20,"analysis":33},1022293,"某1OkV中性点绝缘系统，线路末端接有空载变压器，容量为400kV A，线路对地电容为5000pF\u002Fkm,变压器空载电流为1.5%。 该变压器的励磁电抗为（ )。",[502,504,506,508],{"key":20,"text":503,"correct":26},"1.7x104Ω；",{"key":24,"text":505,"correct":22},"1.8x104Ω；",{"key":28,"text":507,"correct":22},"1.9x104Ω；",{"key":31,"text":509,"correct":22},"2.0x104Ω。",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":28,"analysis":33},1022294,"某1OkV中性点绝缘系统，线路末端接有空载变压器，容量为400kV A，线路对地电容为5000pF\u002Fkm,变压器空载电流为1.5%。 断线时不发生基波谐振的线路长度为（）。",[514,516,518,520],{"key":20,"text":515,"correct":22},"7km;",{"key":24,"text":517,"correct":22},"8km；",{"key":28,"text":519,"correct":26},"8.5km;",{"key":31,"text":521,"correct":22},"9km。",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":28,"analysis":33},1022295,"两根平行避雷线的高度同为20m，两线间距离为48m，则两避雷线保护范围上部边缘最低点的高度为（）。",[526,528,530,532],{"key":20,"text":527,"correct":22},"6m;",{"key":24,"text":529,"correct":22},"7m;",{"key":28,"text":531,"correct":26},"8m；",{"key":31,"text":533,"correct":22},"9m。",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":31,"analysis":33},1022296,"阀式避雷器标称放电电流下的残压，不应大于被保护电气设备（旋转电机除外）标准雷电冲击全波耐受电压的（）。",[538,540,542,544],{"key":20,"text":539,"correct":22},"62%；",{"key":24,"text":541,"correct":22},"65%；",{"key":28,"text":543,"correct":22},"68%；",{"key":31,"text":545,"correct":26},"71%。",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":24,"analysis":33},1022297,"发电厂和变电所内（）及以上避雷器应装设简单可靠的多次动作记录器。",[550,552,554,556],{"key":20,"text":551,"correct":22},"1OkV；",{"key":24,"text":553,"correct":26},"35kV；",{"key":28,"text":555,"correct":22},"66kV；",{"key":31,"text":557,"correct":22},"11OkV。",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":20,"analysis":33},1022298,"按开断续流的范围选择排气式避雷器。如最大短路电流计算困难，对发电厂附近，可将周期分量第一个半周期的有效值乘以（对发电厂较远地点，可将周期分量第一个半周期有效值乘以（）。",[562,564,566,568],{"key":20,"text":563,"correct":26},"1.5，1.3；",{"key":24,"text":565,"correct":22},"1.3,1.5；",{"key":28,"text":567,"correct":22},"1.6，1.4；",{"key":31,"text":569,"correct":22},"1.4，1.6。",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":31,"analysis":33},1022299,"35kV系统若采用保护间隙，其保护间隙的主间隙距离不应小于（辅助间隙的距离可采用（）。",[574,576,578,580],{"key":20,"text":575,"correct":22},"180mm,15mm；",{"key":24,"text":577,"correct":22},"190mm,16mm；",{"key":28,"text":579,"correct":22},"200mm,18mm;",{"key":31,"text":581,"correct":26},"210mm,20mm。",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":28,"analysis":33},1022300,"避雷针与易燃油贮罐呼吸阀和氢气天然气等罐体呼吸阀之间的空中距离，避雷针与呼吸阀的水平距离不应小于（）;避雷针尖髙出呼吸阀不应小于（）。",[586,588,590,592],{"key":20,"text":587,"correct":22},"2m,2m；",{"key":24,"text":589,"correct":22},"3m，2m；",{"key":28,"text":591,"correct":26},"3m,3m；",{"key":31,"text":593,"correct":22},"4m,4m?",{"id":595,"libraryId":5,"type":15,"typeLabel":16,"stem":596,"options":597,"answer":24,"analysis":33},1022301,"独立避雷针（线）宜设独立的接地装置，在非高土壤电阻率地区，若其接地装置的接地电阻做到小于1OΩ有困难时，该接地装置可与主接地网连接，但避雷针与主接地网的地下连接点至（）及以下设备与主接地网的地下连接点之间’沿接地体的长度不得小于（）。",[598,600,602,604],{"key":20,"text":599,"correct":22},"1OkV,12m；",{"key":24,"text":601,"correct":26},"35kV,15m;",{"key":28,"text":603,"correct":22},"66kV,15m；",{"key":31,"text":605,"correct":22},"110kV,12m。",{"id":607,"libraryId":5,"type":15,"typeLabel":16,"stem":608,"options":609,"answer":31,"analysis":33},1022302,"110kV及以上的配电装置，一般将避雷针装在配电装置的架构或房顶上，但在电阻率大于（）地区，宜装设独立避雷针。",[610,612,614,616],{"key":20,"text":611,"correct":22},"350Ω?m；",{"key":24,"text":613,"correct":22},"500Ω?m;",{"key":28,"text":615,"correct":22},"750Ω?m;",{"key":31,"text":617,"correct":26},"OOOΩ?m。",[619,622,625,628,631,634],{"id":15,"name":620,"category":7,"favorite":621},"领导干部任职前廉政法规知识测试题",92,{"id":623,"name":624,"category":7,"favorite":15},595,"建筑结构与设备",{"id":626,"name":627,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":629,"name":630,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":632,"name":633,"category":7,"favorite":8},534,"BIM工程师",{"id":635,"name":633,"category":7,"favorite":8},535]