[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-10":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":609},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,10,50,2670,[13,34,46,58,70,82,94,105,117,129,141,153,165,177,189,201,213,221,233,245,257,269,281,293,304,316,328,340,352,364,376,386,398,410,422,434,444,456,467,479,491,503,515,527,539,549,561,573,585,597],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},1022202,1,"单选题","220kV变电所中电气设备、绝缘子串、空气间隙的绝缘配合中，以避雷器保护水平的相应基础进行绝缘配合的是（）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","电气设备操作冲击绝缘水平；",false,{"key":24,"text":25,"correct":22},"B","绝缘子串、空气间隙的操作冲击绝缘强度；",{"key":27,"text":28,"correct":29},"C","C电气设备、绝缘子串和空气间隙的雷电冲击强度；",true,{"key":31,"text":32,"correct":22},"D","绝缘子串、空气间隙的操作过电压要求的绝缘水平。","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},1022203,"范围I的架空线路和变电所绝缘子串、空气间隙的操作过电压要求的绝缘水平，进确缘配合的基础是（）。",[38,40,42,44],{"key":20,"text":39,"correct":29},"计算用最大操作过电压；",{"key":24,"text":41,"correct":22},"最大解列过电压；",{"key":27,"text":43,"correct":22},"开断空载长线过电压；",{"key":31,"text":45,"correct":22},"开断空载变压器过电压。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},1022204,"当送电线路、变电所因海拔高度引起气象条件变化而异于标准状态时，可按照相关规定校正。海拔髙度1OOOm及以下地区，按海拔高度（）条件校正。",[50,52,54,56],{"key":20,"text":51,"correct":22},"0m；",{"key":24,"text":53,"correct":22},"1OOm；",{"key":27,"text":55,"correct":22},"500m；",{"key":31,"text":57,"correct":29},"1OOOm。",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},1022205,"在绝缘配合中，110kV及220kV系统相对地计算用最大操作过电压的标么值应该取（）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"2.0；",{"key":24,"text":65,"correct":22},"2.5；",{"key":27,"text":67,"correct":29},"3.O；",{"key":31,"text":69,"correct":22},"4.0。",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":27,"analysis":33},1022206,"在绝缘配合经常使用的避雷器在标称雷电流下的额定残压值，220kV电压的标称雷电流取值为（）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"2kA；",{"key":24,"text":77,"correct":22},"5kA；",{"key":27,"text":79,"correct":29},"1OkA；",{"key":31,"text":81,"correct":22},"20kA。",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},1022207,"海拔不超过1000m地区的110kV变电所工频电压要求相对地的最小空气间暸值（相对地）为（）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"15cm；",{"key":24,"text":89,"correct":29},"30cm;",{"key":27,"text":91,"correct":22},"45cm；",{"key":31,"text":93,"correct":22},"60cm。",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},1022208,"海拔不超过1000m地区、1OkV高压配电装置的最小户外的相对地、相间空气间隙（相对地、相间取同一值）为（）。",[98,99,101,103],{"key":20,"text":87,"correct":22},{"key":24,"text":100,"correct":29},"20cm；",{"key":27,"text":102,"correct":22},"25cm；",{"key":31,"text":104,"correct":22},"30cm。",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":27,"analysis":33},1022209,"操作过电压下的绝缘配合中，电压范围n的变压器的相间绝缘的额定操作冲击耐受电压等于相应的相对地绝缘的耐受电压值乘以系数Kpe，通常Kpe取值为（）。",[109,111,113,115],{"key":20,"text":110,"correct":22},"1.05；",{"key":24,"text":112,"correct":22},"1.15；",{"key":27,"text":114,"correct":29},"1.5；",{"key":31,"text":116,"correct":22},"1.65。",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":24,"analysis":33},1022210,"电压范围II变电所电气设备与操作过电压的绝缘配令中，电气设备内绝缘相对地额定操作冲击耐压与避雷器操作过电压保护水平间的配合系数的取值不应小于（）。",[121,123,125,127],{"key":20,"text":122,"correct":22},"1.1倍；",{"key":24,"text":124,"correct":29},"1.15倍；",{"key":27,"text":126,"correct":22},"1.2倍；",{"key":31,"text":128,"correct":22},"1.25倍。",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":27,"analysis":33},1022211,"电气设备与操作过电压的绝缘配合时，在电气设备外绝缘的耐压取值方法中，以下方法错误的是（）。",[133,135,137,139],{"key":20,"text":134,"correct":22},"电气设备外絶缘相对地千态额定操作冲击耐压与相应设备的内绝缘額定搮作冲击耐压相同；",{"key":24,"text":136,"correct":22},"变压器外绝缘相间千态额定操作冲击耐压与其内绝缘相间额定操作冲击耐压相同；",{"key":27,"text":138,"correct":29},"断路器、隔离开关同极断口间外绝缘額定操作冲击耐压应该大于断路器断口间内绝缘的相应值，一般耐压值可大于5%；",{"key":31,"text":140,"correct":22},"断路器、隔离开关同极断口间外绝缘額定搮作冲击耐压与断路器断口间内绝缘的相应值相同。",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":31,"analysis":33},1022212,"雷电过电压下的绝缘配合中，对受避雷器保护的设备，其额定雷电冲击耐受电压由避雷器的雷电冲击保护水平乘以配合因数Kc计算选定。一般情况下Kc取值为（）。",[145,147,149,151],{"key":20,"text":146,"correct":22},"Kc≥1.15；",{"key":24,"text":148,"correct":22},"Kc≥1.25；",{"key":27,"text":150,"correct":22},"Kc≥1.3；",{"key":31,"text":152,"correct":29},"Kc≥1.4.",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":27,"analysis":33},1022213,"对于66kV设备的标准绝缘水平，额定雷电冲击耐受电压（峰值）和额定短时工频耐受电压（有效值）分别是（）。",[157,159,161,163],{"key":20,"text":158,"correct":22},"95kV、85kV；",{"key":24,"text":160,"correct":22},"185kV、105kV；",{"key":27,"text":162,"correct":29},"325kV、155kV；",{"key":31,"text":164,"correct":22},"450kV、185kV。",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":31,"analysis":33},1022214,"220kV电力变压器、并联电抗器和电压互感器设备的额定雷电冲击耐受电压（峰值）应该是（）。",[169,171,173,175],{"key":20,"text":170,"correct":22},"325（350kV）；",{"key":24,"text":172,"correct":22},"450（550kV）;",{"key":27,"text":174,"correct":22},"480（625kV）；",{"key":31,"text":176,"correct":29},"850（950kV）。",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":31,"analysis":33},1022215,"以下雷电过电压绝缘配合原则中，不必要的是（）。",[181,183,185,187],{"key":20,"text":182,"correct":22},"变电所中电气设备、绝缘子串和空气间隙的雷电冲击强度，以避雷器的雷电保护水平为基础进行配合；",{"key":24,"text":184,"correct":22},"送电线路按规程对各级电压要求的耐雷水平进行配合；",{"key":27,"text":186,"correct":22},"在悬垂绝缘子串的空气间隙绝缘配合中，应计及导线风偏的影响；",{"key":31,"text":188,"correct":29},"变电所雷电过压的绝缘配合还应对线路的雷电入侵波作配合。",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":27,"analysis":33},1022216,"现有一组500kV高压SF6断路器，下列数据中不属于标准（相对地）绝缘水平的是（ ）。",[193,195,197,199],{"key":20,"text":194,"correct":22},"额定操作冲击耐受电压1050kV;",{"key":24,"text":196,"correct":22},"额定雷电冲击耐受电压1425kV;",{"key":27,"text":198,"correct":29},"額定工頻冲击耐受电压860kV;",{"key":31,"text":200,"correct":22},"額定短时工频耐受电压630kV。",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":31,"analysis":33},1022217,"范围I系统的工频过电压水平一般不超过下列数值：110kV及220kV为（），35kV及66kV系统为（），3kV及1OkV系统为（）。",[205,207,209,211],{"key":20,"text":206,"correct":22},"1.5p.u.、1.1√3p.u.、√3p.u.；",{"key":24,"text":208,"correct":22},"1.4p.u.、1.2√3p.u.、√3p.u.；",{"key":27,"text":210,"correct":22},"1.3p.u、1.1√3p.u.、√3p.u.；",{"key":31,"text":212,"correct":29},"1.3p.u.、√3p.u.、1.1√3p.u.。",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":20,"analysis":33},1022218,"范围II系统的工频过电压水平在线路断路器的变电所侧一般不宜超过（），在线路断路器的线路侧一般不宜超过（）。 A.1.3p.u、1.4p.u； B.1.2p.u.、1.4p.u.； C.1.3p.u.、1.2p.u.； D,1.2p.u.、1.u.。",[217,218,219,220],{"key":20,"text":20,"correct":29},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":31,"text":31,"correct":22},{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":27,"analysis":33},1022219,"在范围n的系统当空载线路上接有并联电抗器时，在并联电抗器的中性点与大地之间串接一接地电抗器，以防止铁磁谐振过电压的产生。该接地电抗器的电抗值宜按补偿并联电抗器所接线路的（）相间电容选取。",[225,227,229,231],{"key":20,"text":226,"correct":22},"1\u002F3倍；",{"key":24,"text":228,"correct":22},"1\u002F2倍；",{"key":27,"text":230,"correct":29},"1倍；",{"key":31,"text":232,"correct":22},"2倍.",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":20,"analysis":33},1022220,"范围II的系统中，当空载线路（或其上接有空载变压器时）由电源变压器断路器合闸、重合闸或由只带有空载线路的变压器低压俩合闸、带电线路末端的空载变压器合闸以及系统解列等情况下，可能产生以（）谐波为主的髙次谐波谐振过电压。",[237,239,241,243],{"key":20,"text":238,"correct":29},"2次；",{"key":24,"text":240,"correct":22},"3次；",{"key":27,"text":242,"correct":22},"4次；",{"key":31,"text":244,"correct":22},"5次。",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":24,"analysis":33},1022221,"范围I的系统中，由单一电源侧用断路器操作中性点不接地的变压器出现非全相或熔断器非全相熔断时，如变压器的励磁电感与对地电容产生铁磁谐振，能产生（）的过电压。",[249,251,253,255],{"key":20,"text":250,"correct":22},"1.5p.u.~1.8p.u.；",{"key":24,"text":252,"correct":29},"2.Op.u.~3.Op.u.；",{"key":27,"text":254,"correct":22},"2.5p.u.~3.Op.u.；",{"key":31,"text":256,"correct":22},"3.Op.u.~3.5p.u.。",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":27,"analysis":33},1022222,"范围I的系统中，由于两侧电源的不同步，在非全相分合闸时，在变压器中性点上可出现接近于（）的过电压，如产生铁磁谐振，则会出现更高的过电压。",[261,263,265,267],{"key":20,"text":262,"correct":22},"1.5p.u.；",{"key":24,"text":264,"correct":22},"1.8p.u.；",{"key":27,"text":266,"correct":29},"2.Op.u.；",{"key":31,"text":268,"correct":22},"2.3p.u.。",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":31,"analysis":33},1022223,"3~66kV不接地系统或经消弧线圈接地系统偶然脱离消弧线圈的部分，为避免电磁式电压互感器过饱和可能产生铁磁谐振过电压，宜在互感器的开口三角形绕组装设（）的电阻。 A.R≤0.1（Xm\u002FK2）；",[273,275,277,279],{"key":20,"text":274,"correct":22},"R≤0.2（Xm\u002FK2）；",{"key":24,"text":276,"correct":22},"R≤0.3（Xm\u002FK2）；.",{"key":27,"text":278,"correct":22},"R≤0.4（Xm\u002FK2）。",{"key":31,"text":280,"correct":29},"注：K为互感器一次绕组与开口三角形绕组的变比。",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":27,"analysis":33},1022224,"3~1OkV不接地系统或经消弧线圈接地系统偶然脱离消弧线圈的部分，为避免电磁式电压互感器过饱和可能产生铁磁谐振过电压，宜在1OkV及以下互感器髙压绕组中性点经容量大于600W（）的电阻接地。",[285,287,289,291],{"key":20,"text":286,"correct":22},"R≥O.02Xm;",{"key":24,"text":288,"correct":22},"R≥O.04Xm；",{"key":27,"text":290,"correct":29},"R≥0.06Xm；",{"key":31,"text":292,"correct":22},"R≥O.08Xm。",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":24,"analysis":33},1022225,"在500kV系统中，空载线路合闸和单相重合闸，在线路上产生的相对地操作过电压水平不宜超过（）。",[297,299,300,302],{"key":20,"text":298,"correct":22},"1.9p.u.；",{"key":24,"text":266,"correct":29},{"key":27,"text":301,"correct":22},"2.1p.u.；",{"key":31,"text":303,"correct":22},"2.2p.u.。",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":27,"analysis":33},1022226,"在500kV系统中，变电所的出线满足线路长度小于（）的条件时，可仅用金屑氧化物避雷器限制合闸和重合闸过电压。",[308,310,312,314],{"key":20,"text":309,"correct":22},"150km;",{"key":24,"text":311,"correct":22},"180km；",{"key":27,"text":313,"correct":29},"200km；",{"key":31,"text":315,"correct":22},"230km。",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":27,"analysis":33},1022227,"在范围I系统中，线路的合闸和重合闸操作过电压一般不超过（）。",[320,322,324,326],{"key":20,"text":321,"correct":22},"2.5p.u.；",{"key":24,"text":323,"correct":22},"2.8p.u.；",{"key":27,"text":325,"correct":29},"3.Op.u.；",{"key":31,"text":327,"correct":22},"3.2p,u.。",{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":27,"analysis":33},1022228,"对范围II系统，现场进行断路器弁断空载线路的试验中，应要求电源对地电压为（），断路器不发生重击穿。",[332,334,336,338],{"key":20,"text":333,"correct":22},"1.1p.u.；",{"key":24,"text":335,"correct":22},"1.2p.u.；",{"key":27,"text":337,"correct":29},"1.3p.u.；",{"key":31,"text":339,"correct":22},"1.4p.u.。",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":27,"analysis":33},1022229,"两根等高避雷线，高度为18m,其间距离为14m。",[344,346,348,350],{"key":20,"text":345,"correct":22},"两避雷线间保护范围上部边缘最低点高度为（）。",{"key":24,"text":347,"correct":22},"12.5m；",{"key":27,"text":349,"correct":29},"13.5m； C14.5m；",{"key":31,"text":351,"correct":22},"15.5m。",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":20,"analysis":33},1022230,"两根等高避雷线，高度为18m,其间距离为14m。 若被保护物髙度为12m,两避雷线端部两侧保护最小宽度为（）。",[356,358,360,362],{"key":20,"text":357,"correct":29},"1.17m;",{"key":24,"text":359,"correct":22},"1.22m；",{"key":27,"text":361,"correct":22},"1.36m;",{"key":31,"text":363,"correct":22},"1.45m.",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":27,"analysis":33},1022231,"在110kV和330kV系统中，为避免、降低工频过电压，一般可根据实际情况，通过技术经济比较可分别采取相应的措施。 对于110kV系统可采取的措施是（ ）。",[368,370,372,374],{"key":20,"text":369,"correct":22},"在线路上架设良导体避雷线；",{"key":24,"text":371,"correct":22},"在线路上安装并联电抗器；",{"key":27,"text":373,"correct":29},"应避免偶然形成局部不接地系统，对可能形成的局部系统，变压器不接地中性点应装设间隙；",{"key":31,"text":375,"correct":22},"可在线路側装设避雷器。",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":24,"analysis":33},1022232,"在110kV和330kV系统中，为避免、降低工频过电压，一般可根据实际情况，通过技术经济比较可分别采取相应的措施。 对于330kV系统可采取的措施是（ ）。",[380,382,384,385],{"key":20,"text":381,"correct":22},"可在母线上装设避雷器；",{"key":24,"text":383,"correct":29},"可在线路上安装并联电抗器；",{"key":27,"text":373,"correct":22},{"key":31,"text":375,"correct":22},{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":31,"analysis":33},1022233,"每串绝缘子的片数在满足操作过电压要求的词时，还应符合工频电压的爬电距离要求，防污设计依照审定的污秽分区和污秽标准分级及爬距要求（见DL\u002FT5092—1999《线路设计规程》附录 B），计算公式为 式中m—每串绝缘子片数； Um——系统最高运行电压，kV; λ——要求的爬电比距，cm\u002FkV； L0——每片悬式绝缘子的几何爬电距离，cm; Kc——式绝缘子的有效系数。 某500kV线路，其清洁区悬垂绝缘子串用XP1-160绝缘子（Kc=1,L0=30.5cm,Um=550kV）要求的片数为（）。",[390,392,394,396],{"key":20,"text":391,"correct":22},"24；",{"key":24,"text":393,"correct":22},"25；",{"key":27,"text":395,"correct":22},"26；",{"key":31,"text":397,"correct":29},"27。",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":31,"analysis":33},1022234,"每串绝缘子的片数在满足操作过电压要求的词时，还应符合工频电压的爬电距离要求，防污设计依照审定的污秽分区和污秽标准分级及爬距要求（见DL\u002FT5092—1999《线路设计规程》附录 B），计算公式为 式中m—每串绝缘子片数； Um——系统最高运行电压，kV; λ——要求的爬电比距，cm\u002FkV； L0——每片悬式绝缘子的几何爬电距离，cm; Kc——式绝缘子的有效系数。 某500kV线路其二级污秽区的悬垂绝缘子串若选用XP1-160绝缘子要求的片数为（）。",[402,404,406,408],{"key":20,"text":403,"correct":22},"35；",{"key":24,"text":405,"correct":22},"37;",{"key":27,"text":407,"correct":22},"39；",{"key":31,"text":409,"correct":29},"40。",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":27,"analysis":33},1022235,"每串绝缘子的片数在满足操作过电压要求的词时，还应符合工频电压的爬电距离要求，防污设计依照审定的污秽分区和污秽标准分级及爬距要求（见DL\u002FT5092—1999《线路设计规程》附录 B），计算公式为 式中m—每串绝缘子片数； Um——系统最高运行电压，kV; λ——要求的爬电比距，cm\u002FkV； L0——每片悬式绝缘子的几何爬电距离，cm; Kc——式绝缘子的有效系数。 同（2）,但若选用 XPW-160绝缘子（Kc=0.94,L0=40cm,Um=525kV）要求的片数为（）。",[414,416,418,420],{"key":20,"text":415,"correct":22},"28；",{"key":24,"text":417,"correct":22},"30；",{"key":27,"text":419,"correct":29},"37；",{"key":31,"text":421,"correct":22},"34。",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":31,"analysis":33},1022236,"现有一个500kV变电所，500kV和220kV髙压配电装置分别采用一个半断路器主接线和双母线接线，其雷电接入波过电压保护按标准判定在有些地方可不装设金属氧化物避雷器。 对于500kV高压配电装置，可不装设金属氧化物避雷器的地方为（）。",[426,428,430,432],{"key":20,"text":427,"correct":22},"在每回线路的入口；",{"key":24,"text":429,"correct":22},"每一主变压器回路；",{"key":27,"text":431,"correct":22},"经小电抗接地的并联电抗器中性点；",{"key":31,"text":433,"correct":29},"每一母线。",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":20,"analysis":33},1022237,"现有一个500kV变电所，500kV和220kV髙压配电装置分别采用一个半断路器主接线和双母线接线，其雷电接入波过电压保护按标准判定在有些地方可不装设金属氧化物避雷器。 对于220kV高压配电装置，可不装设金属氧化物避雷器的地方为（）。",[438,439,440,442],{"key":20,"text":427,"correct":29},{"key":24,"text":429,"correct":22},{"key":27,"text":441,"correct":22},"中性点采用分级绝缘且不接地的变庄器的中性点；",{"key":31,"text":443,"correct":22},"每一组母线。",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":24,"analysis":33},1022238,"某330kV变电所，在其330kV敞开式高压配电装置中，进出线采用架空线，当有双回进线和四回进线的情况下，电气设备采用标准绝缘水平时，请分别确定金属氧化物避雷器至主变压器的最大距离。 当有双回进线时，避雷器至主变压器的最大距离应该是（）。",[448,450,452,454],{"key":20,"text":449,"correct":22},"90m；",{"key":24,"text":451,"correct":29},"140m；",{"key":27,"text":453,"correct":22},"160m；",{"key":31,"text":455,"correct":22},"180m。",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":31,"analysis":33},1022239,"某330kV变电所，在其330kV敞开式高压配电装置中，进出线采用架空线，当有双回进线和四回进线的情况下，电气设备采用标准绝缘水平时，请分别确定金属氧化物避雷器至主变压器的最大距离。 当有四回进线时，避雷器至主变压器的最大距离应该是（）。",[460,461,463,465],{"key":20,"text":53,"correct":22},{"key":24,"text":462,"correct":22},"150m,",{"key":27,"text":464,"correct":22},"170m；",{"key":31,"text":466,"correct":29},"19Om。",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":27,"analysis":33},1022240,"在预防雷电过电压中，标准对雷电活动的强弱进行了分类，在四种雷区中规定的平均年雷暴日数值不同。 少雷地区的平均年雷暴日为（）。",[471,473,475,477],{"key":20,"text":472,"correct":22},"≤10,",{"key":24,"text":474,"correct":22},"≤12；",{"key":27,"text":476,"correct":29},"≤15;",{"key":31,"text":478,"correct":22},"≤20。",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":20,"analysis":33},1022241,"在预防雷电过电压中，标准对雷电活动的强弱进行了分类，在四种雷区中规定的平均年雷暴日数值不同。 中雷地区的平均年雷暴日为（）。",[483,485,487,489],{"key":20,"text":484,"correct":29},"15~40;",{"key":24,"text":486,"correct":22},"20—50；",{"key":27,"text":488,"correct":22},"25~60;",{"key":31,"text":490,"correct":22},"30~65。",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":27,"analysis":33},1022242,"在预防雷电过电压中，标准对雷电活动的强弱进行了分类，在四种雷区中规定的平均年雷暴日数值不同。 多雷地区的平均年雷暴日为（ ）。",[495,497,499,501],{"key":20,"text":496,"correct":22},"20~40;",{"key":24,"text":498,"correct":22},"30~60;",{"key":27,"text":500,"correct":29},"40~90；",{"key":31,"text":502,"correct":22},"60~100?",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":24,"analysis":33},1022243,"在预防雷电过电压中，标准对雷电活动的强弱进行了分类，在四种雷区中规定的平均年雷暴日数值不同。 雷电活动特殊强烈地区的平均年雷暴日为（）。",[507,509,511,513],{"key":20,"text":508,"correct":22},"≥60；",{"key":24,"text":510,"correct":29},"≥90；",{"key":27,"text":512,"correct":22},"≥120；",{"key":31,"text":514,"correct":22},"≥140。",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":31,"analysis":33},1022244,"在预防雷电过电压中，标准对雷电活动的强弱进行了分类，在四种雷区中规定的平均年雷暴日数值不同。 根据雷区划分，平均年雷暴日数为85，它应该属于（）。",[519,521,523,525],{"key":20,"text":520,"correct":22},"少雷区；",{"key":24,"text":522,"correct":22},"特殊铎烈雷区；",{"key":27,"text":524,"correct":22},"中當区；",{"key":31,"text":526,"correct":29},"多雷区。",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":31,"analysis":33},1022245,"对于小型发电厂，其单机容量为25MW的直配电机设有发电机电压母线，且每组母线均接有两台发电机的情况时，或当单机容量为6MW的直配电机时，不需装设避雷器。 当单机容量为25MW的条件时，不需装雷设避雷器的是（）。",[531,533,535,537],{"key":20,"text":532,"correct":22},"在靠近电机处；",{"key":24,"text":534,"correct":22},"在电机出线处；",{"key":27,"text":536,"correct":22},"在每一组母线上；",{"key":31,"text":538,"correct":29},"如进线电缆段大于200m，在进线电缆段末端处。",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":27,"analysis":33},1022246,"对于小型发电厂，其单机容量为25MW的直配电机设有发电机电压母线，且每组母线均接有两台发电机的情况时，或当单机容量为6MW的直配电机时，不需装设避雷器。 当单机容量为6MW时，不需装设避雷器的是（ ）。",[543,544,545,547],{"key":20,"text":534,"correct":22},{"key":24,"text":536,"correct":22},{"key":27,"text":546,"correct":29},"如进线电缆段大于100m，在进线电缆段末端处；",{"key":31,"text":548,"correct":22},"在进线保护段上.",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":24,"analysis":33},1022247,"某发电厂拟采用悬挂高度分别为26、30m的单根避雷线作为某设施（高度为15m）的防雷保护，现按有关公式分别计算出在、水平面上每侧保护范围的宽度。 当避雷线悬挂高度为26m时，每侧保护范围的宽度为（）。",[553,555,557,559],{"key":20,"text":554,"correct":22},"2.85m;",{"key":24,"text":556,"correct":29},"5.17m;",{"key":27,"text":558,"correct":22},"3.24；",{"key":31,"text":560,"correct":22},"4.12m。",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":20,"analysis":33},1022248,"某发电厂拟采用悬挂高度分别为26、30m的单根避雷线作为某设施（高度为15m）的防雷保护，现按有关公式分别计算出在、水平面上每侧保护范围的宽度。 当避雷线悬挂高度为30m时，每侧保护范围的宽度为（ ）。",[565,567,569,571],{"key":20,"text":566,"correct":29},"7.05m;",{"key":24,"text":568,"correct":22},"7.78m;",{"key":27,"text":570,"correct":22},"8.48；",{"key":31,"text":572,"correct":22},"8.86m。",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":31,"analysis":33},1022249,"某发电厂采用三回110kV架空出线，且全线均有避雷线。11OkV配电装置采用双母线接线，每组母线上装设了金属氧化锌避雷器。请按此条件分析确定应在主变压器附近增设一组避雷器的避雷器与主变压器的电气距离。 当采用三回110kV架空出线时，避雷器与主变压器的最大电气距离是（）。",[577,579,581,583],{"key":20,"text":578,"correct":22},"125m；",{"key":24,"text":580,"correct":22},"145m；",{"key":27,"text":582,"correct":22},"170m;",{"key":31,"text":584,"correct":29},"205m。",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":24,"analysis":33},1022250,"某发电厂采用三回110kV架空出线，且全线均有避雷线。11OkV配电装置采用双母线接线，每组母线上装设了金属氧化锌避雷器。请按此条件分析确定应在主变压器附近增设一组避雷器的避雷器与主变压器的电气距离。 当采用五回110kV架空出线时，避雷器与主变压器的最大电气距离是（）。",[589,591,593,595],{"key":20,"text":590,"correct":22},"210m；",{"key":24,"text":592,"correct":29},"230m;",{"key":27,"text":594,"correct":22},"235m;",{"key":31,"text":596,"correct":22},"265m。",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":27,"analysis":33},1022251,"在绝缘配合标准中，送电线路、变电所绝缘子串及空气间隙的绝缘配合公式均按标准气象条件给出。请在下列各组气象条件数据中，分别确定标准气象条件（气压P、温度T、绝对湿度 H）的有关数据，（1mmHg=133.322Pa） 标准气象条件的气压P等于（）。",[601,603,605,607],{"key":20,"text":602,"correct":22},"8.933kPa；",{"key":24,"text":604,"correct":22},"9.933kPa；",{"key":27,"text":606,"correct":29},"101.325kPa；",{"key":31,"text":608,"correct":22},"102.325kPa。",[610,613,616,619,622,625],{"id":15,"name":611,"category":7,"favorite":612},"领导干部任职前廉政法规知识测试题",92,{"id":614,"name":615,"category":7,"favorite":15},595,"建筑结构与设备",{"id":617,"name":618,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":620,"name":621,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":623,"name":624,"category":7,"favorite":8},534,"BIM工程师",{"id":626,"name":624,"category":7,"favorite":8},535]