[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-751-1":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":614},{"id":5,"name":6,"category":7,"favorite":8},751,"电气工程师发输变电专业","建筑工程",0,1,50,2670,[13,33,45,57,69,81,93,105,117,129,141,153,164,176,185,197,209,221,233,245,257,269,281,293,305,317,329,341,353,365,377,389,401,413,425,437,449,461,473,483,494,506,518,530,542,554,566,578,590,602],{"id":14,"libraryId":5,"type":9,"typeLabel":15,"stem":16,"options":17,"answer":19,"analysis":32},1021749,"单选题","超髙压输电线路的短路大部分为（）。",[18,22,26,29],{"key":19,"text":20,"correct":21},"A","单相短路；",true,{"key":23,"text":24,"correct":25},"B","相间短路；",false,{"key":27,"text":28,"correct":25},"C","三相短路；",{"key":30,"text":31,"correct":25},"D","两相接地短路。","",{"id":34,"libraryId":5,"type":9,"typeLabel":15,"stem":35,"options":36,"answer":19,"analysis":32},1021750,"发生三相对称短路时，短路电流为（）。",[37,39,41,43],{"key":19,"text":38,"correct":21},"正序分量；",{"key":23,"text":40,"correct":25},"负序分量；",{"key":27,"text":42,"correct":25},"零序分量；",{"key":30,"text":44,"correct":25},"正序和负序分量。",{"id":46,"libraryId":5,"type":9,"typeLabel":15,"stem":47,"options":48,"answer":27,"analysis":32},1021751,"只有发生（），零序电流才会出现。",[49,51,53,55],{"key":19,"text":50,"correct":25},"相间故障；",{"key":23,"text":52,"correct":25},"振荡时；",{"key":27,"text":54,"correct":21},"不对称接地故障或非全相运行时；",{"key":30,"text":56,"correct":25},"短路。",{"id":58,"libraryId":5,"type":9,"typeLabel":15,"stem":59,"options":60,"answer":23,"analysis":32},1021752,"零序电流的分布主要取决于（）.",[61,63,65,67],{"key":19,"text":62,"correct":25},"发电机是否接地；",{"key":23,"text":64,"correct":21},"运行中变压器中性点、接地点的分布；",{"key":27,"text":66,"correct":25},"用电设备的外壳是否接地;",{"key":30,"text":68,"correct":25},"故障电流。",{"id":70,"libraryId":5,"type":9,"typeLabel":15,"stem":71,"options":72,"answer":19,"analysis":32},1021753,"—般情况下，下述故障对电力系统稳定运行影响最小的是（）。",[73,75,77,79],{"key":19,"text":74,"correct":21},"单相接地；",{"key":23,"text":76,"correct":25},"两相短路；",{"key":27,"text":78,"correct":25},"两相接地短路；",{"key":30,"text":80,"correct":25},"三相短路。",{"id":82,"libraryId":5,"type":9,"typeLabel":15,"stem":83,"options":84,"answer":27,"analysis":32},1021754,"在计算和分析三相不对称系统短路时，广泛应用（）。",[85,87,89,91],{"key":19,"text":86,"correct":25},"分布系数法；",{"key":23,"text":88,"correct":25},"ΣY法；",{"key":27,"text":90,"correct":21},"对称分量法;",{"key":30,"text":92,"correct":25},"电流反比分配法。",{"id":94,"libraryId":5,"type":9,"typeLabel":15,"stem":95,"options":96,"answer":23,"analysis":32},1021755,"在负序网络中，负序阻抗与正序阻抗不相同的是（）。",[97,99,101,103],{"key":19,"text":98,"correct":25},"变压器；",{"key":23,"text":100,"correct":21},"发电机；",{"key":27,"text":102,"correct":25},"电抗器；",{"key":30,"text":104,"correct":25},"架空线路。",{"id":106,"libraryId":5,"type":9,"typeLabel":15,"stem":107,"options":108,"answer":19,"analysis":32},1021756,"在计算三相不对称系统短路的冲击电流时，异步电动机的反馈电流（）。",[109,111,113,115],{"key":19,"text":110,"correct":21},"忽略不计；",{"key":23,"text":112,"correct":25},"全部考虑；",{"key":27,"text":114,"correct":25},"计及50%；",{"key":30,"text":116,"correct":25},"计及60%。",{"id":118,"libraryId":5,"type":9,"typeLabel":15,"stem":119,"options":120,"answer":19,"analysis":32},1021757,"对于短路，系统最大运行方式和系统最小运行方式的综合阻抗之间的关系是（）。",[121,123,125,127],{"key":19,"text":122,"correct":21},"系统最大运行方式的综合阻抗小，系统最小运行方式的综合阻抗大；",{"key":23,"text":124,"correct":25},"系统最大运行方式的综合阻抗大，系统最小运行方式的综合阻抗小；",{"key":27,"text":126,"correct":25},"相等；",{"key":30,"text":128,"correct":25},"无法确定。",{"id":130,"libraryId":5,"type":9,"typeLabel":15,"stem":131,"options":132,"answer":30,"analysis":32},1021758,"计算短路电流热效应时，多支路向短路点提供短路电流，下列说法正确的是（）。",[133,135,137,139],{"key":19,"text":134,"correct":25},"周期分量和非周期分量均按各支路相加的叠加法则，再计算总的热效应；",{"key":23,"text":136,"correct":25},"周期分量按各支路相加的叠加法則，非周期分量按先求电流和，再计算总的热效应；",{"key":27,"text":138,"correct":25},"非周期分责按支路相加的叠加法则，周期分量按先求各支路电流和，再计算总的热效应；",{"key":30,"text":140,"correct":21},"周期分量和非周期分量均按先求各支路'电流和的法则，再计算总的热效应。",{"id":142,"libraryId":5,"type":9,"typeLabel":15,"stem":143,"options":144,"answer":27,"analysis":32},1021759,"为限制发电厂高压厂用电系统的短路电流，一般不采用（）。",[145,147,149,151],{"key":19,"text":146,"correct":25},"分裂绕组变压器；",{"key":23,"text":148,"correct":25},"变压器分裂运行；",{"key":27,"text":150,"correct":21},"阻抗电压大于10.5%的变压器；",{"key":30,"text":152,"correct":25},"装设电抗器。",{"id":154,"libraryId":5,"type":9,"typeLabel":15,"stem":155,"options":156,"answer":19,"analysis":32},1021760,"在高压厂用电系统的短路计算中，对异步电动机的反馈电流，其周期分量和非周期分量的等值衰减时间常数（）。",[157,158,160,162],{"key":19,"text":126,"correct":21},{"key":23,"text":159,"correct":25},"无法确定；",{"key":27,"text":161,"correct":25},"周期分量等值衰减时间常数大于非周期分量；",{"key":30,"text":163,"correct":25},"周期分量等值衰减时间常数小于非周期分量。",{"id":165,"libraryId":5,"type":9,"typeLabel":15,"stem":166,"options":167,"answer":27,"analysis":32},1021761,"100MW及以下的机组，应计及电动机反馈电流对电器和导体（）的影响。",[168,170,172,174],{"key":19,"text":169,"correct":25},"热稳定；",{"key":23,"text":171,"correct":25},"断路器的开断电流；",{"key":27,"text":173,"correct":21},"动稳定；",{"key":30,"text":175,"correct":25},"动、热稳定及断路器的开断电流。",{"id":177,"libraryId":5,"type":9,"typeLabel":15,"stem":178,"options":179,"answer":30,"analysis":32},1021762,"125MW及以上的机组，应计及电动机反馈电流对电器和导体（）的影响。",[180,181,182,183],{"key":19,"text":169,"correct":25},{"key":23,"text":171,"correct":25},{"key":27,"text":173,"correct":25},{"key":30,"text":184,"correct":21},"动、热穗定及断路器的开断电流。",{"id":186,"libraryId":5,"type":9,"typeLabel":15,"stem":187,"options":188,"answer":30,"analysis":32},1021763,"低压厂用电系统的短路电流计算中，下列描述不正确的是（）。",[189,191,193,195],{"key":19,"text":190,"correct":25},"计及电阻；",{"key":23,"text":192,"correct":25},"计及馈线回路的阻抗；",{"key":27,"text":194,"correct":25},"计及异步电动机的反馈电流；",{"key":30,"text":196,"correct":21},"变压器高压侧的电压在短路时有变化。",{"id":198,"libraryId":5,"type":9,"typeLabel":15,"stem":199,"options":200,"answer":19,"analysis":32},1021764,"高压厂用电系统的短路电流计算中，当主保护装置动作时间与断路器固有分闸时间之和大于（）时，可不考虑短路电流非周期分量对断路器开断能力的影响。",[201,203,205,207],{"key":19,"text":202,"correct":21},"0.15s；",{"key":23,"text":204,"correct":25},"0.11s；",{"key":27,"text":206,"correct":25},"O.1s;",{"key":30,"text":208,"correct":25},"0.2s。",{"id":210,"libraryId":5,"type":9,"typeLabel":15,"stem":211,"options":212,"answer":30,"analysis":32},1021765,"对于分裂变压器，通常制造厂提供的半穿越电抗是指（）。",[213,215,217,219],{"key":19,"text":214,"correct":25},"高压绕组与总的低压绕组间的穿越电抗，并以分裂变压器二次绕组容量为基准的数值；",{"key":23,"text":216,"correct":25},"高压绕组与总的低压绕组间的穿越电抗，并以分裂变压器一次绕组容量为基准的数值；",{"key":27,"text":218,"correct":25},"高压绕组与一个低压绕组间的穿越电抗，并以分裂变压器二次绕组容量为基准的数值；",{"key":30,"text":220,"correct":21},"髙压绕组与一个低压绕组间的穿越电抗，并以分裂变压器一次绕组容量为基准的数值。",{"id":222,"libraryId":5,"type":9,"typeLabel":15,"stem":223,"options":224,"answer":27,"analysis":32},1021766,"为简化380V厂用电系统短路电流计算，可以不考虑占回路总阻抗（）的元件。",[225,227,229,231],{"key":19,"text":226,"correct":25},"15%以上；",{"key":23,"text":228,"correct":25},"10%~15%；",{"key":27,"text":230,"correct":21},"10%以下；",{"key":30,"text":232,"correct":25},"20%以下。",{"id":234,"libraryId":5,"type":9,"typeLabel":15,"stem":235,"options":236,"answer":19,"analysis":32},1021767,"当发电机的强励顶值倍数为2.0时，根据计算电抗查运算曲线得到的短路电流值（）。",[237,239,241,243],{"key":19,"text":238,"correct":21},"需修正，短路电流加大；",{"key":23,"text":240,"correct":25},"需修正，短路电流减小；",{"key":27,"text":242,"correct":25},"不修正；",{"key":30,"text":244,"correct":25},"需修正。",{"id":246,"libraryId":5,"type":9,"typeLabel":15,"stem":247,"options":248,"answer":23,"analysis":32},1021768,"在高压厂用电系统的短路计算中，对厂用电源提供的短路电流，下列描迷正确的是（）.",[249,251,253,255],{"key":19,"text":250,"correct":25},"周期分量和非周期分量的等值衰减时间常数相等；",{"key":23,"text":252,"correct":21},"周期分量不衰减，非周期分量按厂用电源的等值衰减时间常数计算；",{"key":27,"text":254,"correct":25},"周期分量的等值衰减时间常数大于非周期分量的；",{"key":30,"text":256,"correct":25},"周期分量的等值衰减时间常数小于非周期分量的。",{"id":258,"libraryId":5,"type":9,"typeLabel":15,"stem":259,"options":260,"answer":23,"analysis":32},1021769,"某变电所由系统电源降压，简化接线如图5-3所示。 K点I\"为（ ）。",[261,263,265,267],{"key":19,"text":262,"correct":25},"0.56kA；",{"key":23,"text":264,"correct":21},"5.24kA；",{"key":27,"text":266,"correct":25},"0.54kA；",{"key":30,"text":268,"correct":25},"0.62kA。",{"id":270,"libraryId":5,"type":9,"typeLabel":15,"stem":271,"options":272,"answer":27,"analysis":32},1021770,"某变电所由系统电源降压，简化接线如图5-3所示。 K点Ich为（）。",[273,275,277,279],{"key":19,"text":274,"correct":25},"0.72kA；",{"key":23,"text":276,"correct":25},"0.92kA,",{"key":27,"text":278,"correct":21},"7.91kA；",{"key":30,"text":280,"correct":25},"0.84kA。",{"id":282,"libraryId":5,"type":9,"typeLabel":15,"stem":283,"options":284,"answer":27,"analysis":32},1021771,"某变电所由系统电源降压，简化接线如图5-3所示。 K点ich为（）。",[285,287,289,291],{"key":19,"text":286,"correct":25},"1.52kA；",{"key":23,"text":288,"correct":25},"1.42kA；",{"key":27,"text":290,"correct":21},"13.34kA；",{"key":30,"text":292,"correct":25},"1.22kA。",{"id":294,"libraryId":5,"type":9,"typeLabel":15,"stem":295,"options":296,"answer":23,"analysis":32},1021772,"某变电所由系统供给电源，简化接线如图5-4所示。变压器参数：容量120MV A，Sj=100MVA；U xl-2=13.3%。U x1-3=12%， Ux2-3=17.5%；容量比100\u002F100\u002F50。求各侧简化电抗标么值。 x1为（）。",[297,299,301,303],{"key":19,"text":298,"correct":25},"0.0315；",{"key":23,"text":300,"correct":21},"0.0325;",{"key":27,"text":302,"correct":25},"0.0335；",{"key":30,"text":304,"correct":25},"0.0345。",{"id":306,"libraryId":5,"type":9,"typeLabel":15,"stem":307,"options":308,"answer":27,"analysis":32},1021773,"某变电所由系统供给电源，简化接线如图5-4所示。变压器参数：容量120MV A，Sj=100MVA；U xl-2=13.3%,U x1-3=12%, Ux2-3=17.5%；容量比100\u002F100\u002F50。求各侧简化电抗标么值。 x2为（）。",[309,311,313,315],{"key":19,"text":310,"correct":25},"0.0855；",{"key":23,"text":312,"correct":25},"0.0865；",{"key":27,"text":314,"correct":21},"0.0785；",{"key":30,"text":316,"correct":25},"0.0885。",{"id":318,"libraryId":5,"type":9,"typeLabel":15,"stem":319,"options":320,"answer":30,"analysis":32},1021774,"某变电所由系统供给电源，简化接线如图5-4所示。变压器参数：容量120MV A，Sj=100MVA；U xl-2=13.3%,U x1-3=12%, Ux2-3=17.5%；容量比100\u002F100\u002F50。求各侧简化电抗标么值。 x3为（）。",[321,323,325,327],{"key":19,"text":322,"correct":25},"0.0645；",{"key":23,"text":324,"correct":25},"0.0655；",{"key":27,"text":326,"correct":25},"0.0665；",{"key":30,"text":328,"correct":21},"0.0675。",{"id":330,"libraryId":5,"type":9,"typeLabel":15,"stem":331,"options":332,"answer":27,"analysis":32},1021775,"某发电厂有分裂绕组启动变压器（见图5-5），其数据为：变压器容量31500\u002F15000-15000kVA,Sj=1OOMVA,Uk=14.2%；分裂系数3.5；x*1-2=0.45,求网络电抗标么值。",[333,335,337,339],{"key":19,"text":334,"correct":25},"X1为（）。",{"key":23,"text":336,"correct":25},"0.126；",{"key":27,"text":338,"correct":21},"0.136；C0.056；",{"key":30,"text":340,"correct":25},"0.125.",{"id":342,"libraryId":5,"type":9,"typeLabel":15,"stem":343,"options":344,"answer":27,"analysis":32},1021776,"某发电厂有分裂绕组启动变压器（见图5-5），其数据为：变压器容量31500\u002F15000-15000kVA,Sj=1OOMVA,Uk=14.2%；分裂系数3.5；x*1-2=0.45,求网络电抗标么值。 x2=X’2为（）。",[345,347,349,351],{"key":19,"text":346,"correct":25},"0.59；",{"key":23,"text":348,"correct":25},"0.69；",{"key":27,"text":350,"correct":21},"0.79；",{"key":30,"text":352,"correct":25},"0.89。",{"id":354,"libraryId":5,"type":9,"typeLabel":15,"stem":355,"options":356,"answer":19,"analysis":32},1021777,"有分裂电抗器如图5-6所示。参数：额定电流1000 A，电抗10%，额定电压6kV，互感系数f0取0.5，Sj=1OOMVA,x*=0.873（查表得）。求电抗标么值。 x1=x2为（）。",[357,359,361,363],{"key":19,"text":358,"correct":21},"0.436；",{"key":23,"text":360,"correct":25},"0.426；",{"key":27,"text":362,"correct":25},"0.446；",{"key":30,"text":364,"correct":25},"0.456。",{"id":366,"libraryId":5,"type":9,"typeLabel":15,"stem":367,"options":368,"answer":27,"analysis":32},1021778,"如图5-7所示的网络，请用分配系数法简化。 分配系数C1为（）。",[369,371,373,375],{"key":19,"text":370,"correct":25},"0.55；",{"key":23,"text":372,"correct":25},"0.56；",{"key":27,"text":374,"correct":21},"0.66；",{"key":30,"text":376,"correct":25},"0.67。",{"id":378,"libraryId":5,"type":9,"typeLabel":15,"stem":379,"options":380,"answer":27,"analysis":32},1021779,"如图5-7所示的网络，请用分配系数法简化。 x'1为（）。",[381,383,385,387],{"key":19,"text":382,"correct":25},"4.54；",{"key":23,"text":384,"correct":25},"3.54；",{"key":27,"text":386,"correct":21},"5.54；",{"key":30,"text":388,"correct":25},"6.54。",{"id":390,"libraryId":5,"type":9,"typeLabel":15,"stem":391,"options":392,"answer":19,"analysis":32},1021780,"若已知系统简图如图5-8所示。且图中正序电抗x1Σ=0.055，负序电抗x2Σ=0.0565，零序电抗x0Σ=0.0424，Sj=1000MVA。 单相正序电流的有名值I\"1为（）。",[393,395,397,399],{"key":19,"text":394,"correct":21},"7.147kA；",{"key":23,"text":396,"correct":25},"8.147kA；",{"key":27,"text":398,"correct":25},"6.147kA；",{"key":30,"text":400,"correct":25},"9.147kA。",{"id":402,"libraryId":5,"type":9,"typeLabel":15,"stem":403,"options":404,"answer":23,"analysis":32},1021781,"若已知系统简图如图5-8所示。且图中正序电抗x1Σ=0.055，负序电抗x2Σ=0.0565，零序电抗x0Σ=0.0424，Sj=1000MVA。 单相短路电流I\" (1)为（）。",[405,407,409,411],{"key":19,"text":406,"correct":25},"22.44kA；",{"key":23,"text":408,"correct":21},"21.44kA；",{"key":27,"text":410,"correct":25},"23.44kA；",{"key":30,"text":412,"correct":25},"20.44kA,",{"id":414,"libraryId":5,"type":9,"typeLabel":15,"stem":415,"options":416,"answer":19,"analysis":32},1021782,"若已知系统简图如图5-9所示，系统中正序电抗x1Σ=0.055，负序电抗x2Σ=O.0565，零序电抗x0Σ=0.0424，Sj=1000MVA。 两相短路正序电流有名值为（）。",[417,419,421,423],{"key":19,"text":418,"correct":21},"9.867kA；",{"key":23,"text":420,"correct":25},"9.877kA；",{"key":27,"text":422,"correct":25},"9.887kA；",{"key":30,"text":424,"correct":25},"9.879kA。",{"id":426,"libraryId":5,"type":9,"typeLabel":15,"stem":427,"options":428,"answer":23,"analysis":32},1021783,"若已知系统简图如图5-9所示，系统中正序电抗x1Σ=0.055，负序电抗x2Σ=O.0565，零序电抗x0Σ=0.0424，Sj=1000MVA。 两相短路电流有名值为（）。",[429,431,433,435],{"key":19,"text":430,"correct":25},"17.19kA；",{"key":23,"text":432,"correct":21},"17.09kA；",{"key":27,"text":434,"correct":25},"17.29kA；",{"key":30,"text":436,"correct":25},"17.39kA。",{"id":438,"libraryId":5,"type":9,"typeLabel":15,"stem":439,"options":440,"answer":19,"analysis":32},1021784,"已知某系统如图5-10所示，图中正序电抗：x1Σ=0.055，负序电抗x2Σ=0.0565,零序电抗：x0Σ=0.0424,Sj=1OOOMVA。 两相接地短路电流为（）.",[441,443,445,447],{"key":19,"text":442,"correct":21},"20.89kA；",{"key":23,"text":444,"correct":25},"21.89kA；",{"key":27,"text":446,"correct":25},"22.89kA；",{"key":30,"text":448,"correct":25},"23.89kA。",{"id":450,"libraryId":5,"type":9,"typeLabel":15,"stem":451,"options":452,"answer":19,"analysis":32},1021785,"如图5-11所示网络，已知：x1=1,X2=2,x3=3。则x'1、x'2、x'3分别为（）。",[453,455,457,459],{"key":19,"text":454,"correct":21},"3.66,5.5，11；",{"key":23,"text":456,"correct":25},"5.5，3.66，11；",{"key":27,"text":458,"correct":25},"11,3.66，5.5；",{"key":30,"text":460,"correct":25},"11,3.44,5.5。",{"id":462,"libraryId":5,"type":9,"typeLabel":15,"stem":463,"options":464,"answer":23,"analysis":32},1021786,"某电厂现有装机为4台300MW机组，每台机组均采用发电机一变庄器组单元接线接入厂内220kV母线。已知220kV母线发生三相短路时各电源提供的短路电流周期分量有效值为I\"=26k A，冲击系数Kch=1.85。 短路容量S”是（）。",[465,467,469,471],{"key":19,"text":466,"correct":25},"9907.3MVA；",{"key":23,"text":468,"correct":21},"10357.7MVA；",{"key":27,"text":470,"correct":25},"5720MVA；",{"key":30,"text":472,"correct":25},"5980MVA。",{"id":474,"libraryId":5,"type":9,"typeLabel":15,"stem":475,"options":476,"answer":27,"analysis":32},1021787,"某电厂现有装机为4台300MW机组，每台机组均采用发电机一变庄器组单元接线接入厂内220kV母线。已知220kV母线发生三相短路时各电源提供的短路电流周期分量有效值为I\"=26k A，冲击系数Kch=1.85。 冲击电流Ich是（ ）。 A.36.8kA;",[477,479,481],{"key":19,"text":478,"correct":25},"48.1kA；",{"key":23,"text":480,"correct":25},"68.02kA；",{"key":27,"text":482,"correct":21},"83.3k",{"id":484,"libraryId":5,"type":9,"typeLabel":15,"stem":485,"options":486,"answer":19,"analysis":32},1021788,"某电厂现有装机为4台300MW机组，每台机组均采用发电机一变庄器组单元接线接入厂内220kV母线。已知220kV母线发生三相短路时各电源提供的短路电流周期分量有效值为I\"=26k A，冲击系数Kch=1.85。 全电流最大有效值込为（ ）。",[487,489,491,492],{"key":19,"text":488,"correct":21},"40.66kA；",{"key":23,"text":490,"correct":25},"36.8kA;",{"key":27,"text":480,"correct":25},{"key":30,"text":493,"correct":25},"83.3kA。",{"id":495,"libraryId":5,"type":9,"typeLabel":15,"stem":496,"options":497,"answer":23,"analysis":32},1021789,"大型机组高压厂用电短路电流的计算特点。 厂用电母线短路的计算中，下列叙述正确的是（）。",[498,500,502,504],{"key":19,"text":499,"correct":25},"不考虑电动机反馈；",{"key":23,"text":501,"correct":21},"考虑电动机反馈；",{"key":27,"text":503,"correct":25},"考虑大型电动机反馈；",{"key":30,"text":505,"correct":25},"同步电机和异步电机有分别。",{"id":507,"libraryId":5,"type":9,"typeLabel":15,"stem":508,"options":509,"answer":19,"analysis":32},1021790,"大型机组高压厂用电短路电流的计算特点。 对由电源供给的短路电流周期分量和非周期分量，下列说法正确的是（）。",[510,512,514,516],{"key":19,"text":511,"correct":21},"周期分量不考虑衰減，非周期分量考虑衰减；",{"key":23,"text":513,"correct":25},"周期分量考虑衰减；",{"key":27,"text":515,"correct":25},"周期分量和非周期分量均考虑衰减；",{"key":30,"text":517,"correct":25},"非周期分量不考虑衰减。",{"id":519,"libraryId":5,"type":9,"typeLabel":15,"stem":520,"options":521,"answer":27,"analysis":32},1021791,"大型机组高压厂用电短路电流的计算特点。 厂用电短路电流计算中，电动机反馈电流的冲击系数，对大型机组取值为（ ）。",[522,524,526,528],{"key":19,"text":523,"correct":25},"1.8；",{"key":23,"text":525,"correct":25},"1.9；",{"key":27,"text":527,"correct":21},"1.7；",{"key":30,"text":529,"correct":25},"1.6.",{"id":531,"libraryId":5,"type":9,"typeLabel":15,"stem":532,"options":533,"answer":19,"analysis":32},1021792,"设有一台三绕组自耦变压器，容量为500MVA,电压比为500\u002F220\u002F35kV,Ud12=11%,U d13=34%,Ud23=21.2%,Sj=1OOOMVA。简图见图5-12。 电抗标么值为（）。",[534,536,538,540],{"key":19,"text":535,"correct":21},"x1=O.238、x2=-O.018、x3=O.442；",{"key":23,"text":537,"correct":25},"x1=0.018、x2=-O.238、x3=0.442;",{"key":27,"text":539,"correct":25},"x1=—0.018、x2=O.338、x3=O.422;",{"key":30,"text":541,"correct":25},"X1=0.018、X2=O.228、X3=O.422。",{"id":543,"libraryId":5,"type":9,"typeLabel":15,"stem":544,"options":545,"answer":23,"analysis":32},1021793,"某电厂现有装机为2台300MW机组，规划容量为4X300MW机组，每台机组均采用发电机一变压器組单元接线接入厂内220kV母线.已知：220kV系统电抗为0.2（Sj=1OOOMV A）；主变压器370MVA,Ud=14%；发电机Xd'=16%,cosψ=0.85，出口电压为20kV,根据每台机的计算电抗Xjs,査运算曲线，可知每台机的短路电流标么值为3.7，当220kV母线发生三相短路时： 发电机的电抗标么值是（）。",[546,548,550,552],{"key":19,"text":547,"correct":25},"0.476；",{"key":23,"text":549,"correct":21},"0.453；",{"key":27,"text":551,"correct":25},"0.557；",{"key":30,"text":553,"correct":25},"0.53。",{"id":555,"libraryId":5,"type":9,"typeLabel":15,"stem":556,"options":557,"answer":19,"analysis":32},1021794,"某电厂现有装机为2台300MW机组，规划容量为4X300MW机组，每台机组均采用发电机一变压器組单元接线接入厂内220kV母线.已知：220kV系统电抗为0.2（Sj=1OOOMV A）；主变压器370MVA,Ud=14%；发电机Xd'=16%,cosψ=0.85，出口电压为20kV,根据每台机的计算电抗Xjs,査运算曲线，可知每台机的短路电流标么值为3.7，当220kV母线发生三相短路时： 变压器的电抗标么值是（ ）。",[558,560,562,564],{"key":19,"text":559,"correct":21},"0.378；",{"key":23,"text":561,"correct":25},"0.397；",{"key":27,"text":563,"correct":25},"0.34；",{"key":30,"text":565,"correct":25},"0.416.",{"id":567,"libraryId":5,"type":9,"typeLabel":15,"stem":568,"options":569,"answer":19,"analysis":32},1021795,"某电厂现有装机为2台300MW机组，规划容量为4X300MW机组，每台机组均采用发电机一变压器組单元接线接入厂内220kV母线.已知：220kV系统电抗为0.2（Sj=1OOOMV A）；主变压器370MVA,Ud=14%；发电机Xd'=16%,cosψ=0.85，出口电压为20kV,根据每台机的计算电抗Xjs,査运算曲线，可知每台机的短路电流标么值为3.7，当220kV母线发生三相短路时： 1台发电机变压器组的计算电抗标么值是（）。",[570,572,574,576],{"key":19,"text":571,"correct":21},"0.293；",{"key":23,"text":573,"correct":25},"0.587；",{"key":27,"text":575,"correct":25},"1.174；",{"key":30,"text":577,"correct":25},"0.249。",{"id":579,"libraryId":5,"type":9,"typeLabel":15,"stem":580,"options":581,"answer":27,"analysis":32},1021796,"某电厂现有装机为2台300MW机组，规划容量为4X300MW机组，每台机组均采用发电机一变压器組单元接线接入厂内220kV母线.已知：220kV系统电抗为0.2（Sj=1OOOMV A）；主变压器370MVA,Ud=14%；发电机Xd'=16%,cosψ=0.85，出口电压为20kV,根据每台机的计算电抗Xjs,査运算曲线，可知每台机的短路电流标么值为3.7，当220kV母线发生三相短路时： 220kV母线发生三相短路时,发电机提供的短路电流周期分量有效值是（）。",[582,584,586,588],{"key":19,"text":583,"correct":25},"6.56；",{"key":23,"text":585,"correct":25},"6.86；",{"key":27,"text":587,"correct":21},"13.12,",{"key":30,"text":589,"correct":25},"13.72,",{"id":591,"libraryId":5,"type":9,"typeLabel":15,"stem":592,"options":593,"answer":19,"analysis":32},1021797,"某电厂现有装机为2台300MW机组，规划容量为4X300MW机组，每台机组均采用发电机一变压器組单元接线接入厂内220kV母线.已知：220kV系统电抗为0.2（Sj=1OOOMV A）；主变压器370MVA,Ud=14%；发电机Xd'=16%,cosψ=0.85，出口电压为20kV,根据每台机的计算电抗Xjs,査运算曲线，可知每台机的短路电流标么值为3.7，当220kV母线发生三相短路时： 220kV母线发生三相短路时，各电源提供的短路电流周期分量有效值是（）。",[594,596,598,600],{"key":19,"text":595,"correct":21},"25.67；",{"key":23,"text":597,"correct":25},"19.41；",{"key":27,"text":599,"correct":25},"26.27；",{"key":30,"text":601,"correct":25},"19.11,",{"id":603,"libraryId":5,"type":9,"typeLabel":15,"stem":604,"options":605,"answer":23,"analysis":32},1021798,"一台15MVA双绕组高压厂用变压器，短路阻抗在制造上的误差为+5%和一10%,短路阻抗电压为10.5%,取基准容量Sj=1OOMVA,已知发电机出口电压为20kV,发电机出口三相短路电流周期分量的起始值为120k A，参加反馈的6kV电动机额定功率为18000kW,电动机的平均反馈电流倍数为6，髙压电动机的平均ηcosψ取0.8。 变压器电抗标么值为（ ）。",[606,608,610,612],{"key":19,"text":607,"correct":25},"0.77；",{"key":23,"text":609,"correct":21},"0.63；",{"key":27,"text":611,"correct":25},"0.7；",{"key":30,"text":613,"correct":25},"0.735。",[615,618,621,624,627,630],{"id":9,"name":616,"category":7,"favorite":617},"领导干部任职前廉政法规知识测试题",92,{"id":619,"name":620,"category":7,"favorite":9},595,"建筑结构与设备",{"id":622,"name":623,"category":7,"favorite":9},715,"招标采购专业知识与法律法规",{"id":625,"name":626,"category":7,"favorite":9},848,"市政方向-通用基础",{"id":628,"name":629,"category":7,"favorite":8},534,"BIM工程师",{"id":631,"name":629,"category":7,"favorite":8},535]