[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1024358":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},1024358,751,2,"多选题","220~500kV变电所所用电接线方式下述正确的是（），",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","所用低压系统应采用三相四线制，系统的中性点直接接地，系统额定电压采用380V\u002F220V,动力和照明共用供电；",true,{"key":16,"text":17,"correct":18},"B","所用低压系统采用三相三线制，系统的中性点经高电阻接地，系统额定电压采用380V供动力负荷，另设.1台380V\u002F220V照明变压器；",false,{"key":20,"text":21,"correct":14},"C","所用电母线采用按工作变压器划分的单母线接线方式，相邻两狹工作母线间可设分段或联络断路器，但宜同时供电分列运行且两段母线间不宜设自动投入装置；",{"key":23,"text":24,"correct":14},"D","当任一台工作变压器退出时，设有专用的备用变压器应自动切换至失电的工作母线段继续供电。","ACD","",{"id":6,"name":28,"category":29,"favorite":30},"电气工程师发输变电专业","建筑工程",0]