[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1024014":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},1024014,751,2,"多选题","在变电所的绝缘配合中，对于清洁区变电所的绝缘于串应该同时符合以下（）要求。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","絶缘子串正极性操作冲击电压波50%放电电压的计算值，应符合操作过电压的要求；",true,{"key":16,"text":17,"correct":14},"B","绝缘子串正极性雷电冲击电压波50%放电电压计算值，应符合变电所雷电过电压的要求；",{"key":19,"text":20,"correct":21},"C","絶缘子串正极性工频过电压波50%放电电压计算值，应符合变电所工頻过电压要求； ,",false,{"key":23,"text":24,"correct":14},"D","每串绝缘子片数应满足工频电压爬电距离计算值的要求。","ABD","",{"id":6,"name":28,"category":29,"favorite":30},"电气工程师发输变电专业","建筑工程",0]