[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1023557":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},1023557,751,1,"单选题","某220kV变电站位于III级污区，装设180MVA主变压器2台，220kV母线短路电流为12kA；220kV出线6回，全部为负荷线，其中最大输送容量为150MVA；如果220kV出线电流互感器的瓷套平均直径为450mm，试回答以下各题。 选择出线回路电流互感器变比和准确K值系数（）。 A.1000\u002F5A,10倍；",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","600\u002F5",false,{"key":16,"text":17,"correct":18},"B","20倍；",true,{"key":20,"text":21,"correct":14},"C","800\u002F5A,15倍；",{"key":23,"text":24,"correct":14},"D","750\u002F5A,18倍。","解答过程：因为Ig=150000\u002F√3x220=394 （A） 根据以上计算，电流互感器变比和准确限值系数选择应为B。",{"id":6,"name":27,"category":28,"favorite":29},"电气工程师发输变电专业","建筑工程",0]