[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1023491":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},1023491,751,1,"单选题","某水电厂装机容量为3X50MW,选用了3台厂用变压器，且互为备用，发电机电压无直配线。 调速器油泵电机由主屏直接供电，电缆长180m，电动机功率37kW。该回路如逸用铜芯电缆，则截面应为（）（电缆的综合修正系数取1.0，COSφ=O.8,聚氯乙烯绝缘。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","3X16；",false,{"key":16,"text":17,"correct":18},"B","3X25；",true,{"key":20,"text":21,"correct":14},"C","3X35；",{"key":23,"text":24,"correct":14},"D","3X50。","解答过程： 按载流量，3X25即可满足要求。 按《水力发电厂厂用电设计规程》（DL\u002FT5164-2002）第9.2.7条，本回路应校验电 压损失，按△U≤5%计算，R=ρL\u002FS,查《电力工程电气设计手册》⑴P140表4一14，X=0.8R 可求得：S=24.86mm2,故答案为B.",{"id":6,"name":27,"category":28,"favorite":29},"电气工程师发输变电专业","建筑工程",0]