[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1023485":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},1023485,751,1,"单选题","某8X125MW燃煤机组设置有燃油系统，燃油系统及邻近区域电负荷如表1,所有电机的启动电流倍数均为7,功率因数均为0.8。 以上负荷均按II类负荷。 假定表中负荷不设置单独的变压器，而由附近的其他动力中心供电，供电方式为暗备用PC-MCC方式，在燃油区仅设置MCC。则该MCC电源回路的工作电流大致为（） （11项考虑接P C）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","990A；",false,{"key":16,"text":17,"correct":14},"B","800A；",{"key":19,"text":20,"correct":14},"C","610A；",{"key":22,"text":23,"correct":24},"D","460A。",true,"解答过程： 根据《火力发电厂厂用电设计技术规定》（DL\u002FT5153—2002）第4.7.5条，暗备用PC-MCC接线中，75kW以下的电动机宜由MCC供电，75kW及以上的电动机宜由PC供电。参照附录S计算应选择D。",{"id":6,"name":27,"category":28,"favorite":29},"电气工程师发输变电专业","建筑工程",0]