[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1022930":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},1022930,751,1,"单选题","某装机2X300MW的火力发电厂，低压厂用电系统为中性点直接接地。每台机组设一台800kW的柴油发电机作交流保安电源。请对如下设计原则作出判断。 柴油发电机组型式和容量选择中，下面的说法不正确的是（）。 A.柴油发电机组应选择快选自启动的应急型，保安电濛母线失电后第一次启动并恢1母线供电时间取15~20s，应具有自动启动3次成功投入运行的性能;",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","发电机的容量选择的负荷计算方法采用换算系数法，换算系数K取0.7；",false,{"key":16,"text":17,"correct":18},"B","发电机组应进行1h运行输出功率校验，其允许承受的负载能力应不小于aPe\u002Fη",true,{"key":20,"text":21,"correct":14},"C","式中a为柴油发电机组功率配合系数，Pc为计算负荷的有功功率，ηG先为发电机的效率；",{"key":23,"text":24,"correct":14},"D","柴油机的启动方式宜采用电启动。","根据 DL\u002FT5153~2002附录D之D1。",{"id":6,"name":27,"category":28,"favorite":29},"电气工程师发输变电专业","建筑工程",0]