[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1022905":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},1022905,751,1,"单选题","某电厂装有2台600MW机组，每台机组设有2段6kV厂用高压母线，向各厂用电负荷供电，6kV采用手车式开关柜。6kV厂用母线接有1台6300kW给水泵电动机。 6kV—段母线上接有1台6300kW电动给水泵，应选择开关柜上配置的保护与操作设备型式的型式有（）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","采用少油断路器；",false,{"key":16,"text":17,"correct":14},"B","采用F+C组合设备；",{"key":19,"text":20,"correct":14},"C","采用3F6断路器；",{"key":22,"text":23,"correct":24},"D","采用真空断路器。",true,"根据《火力发电厂厂用电设计技术规定》（DL\u002FT5153—2002)第7.2.1条，采用真空断路器。",{"id":6,"name":27,"category":28,"favorite":29},"电气工程师发输变电专业","建筑工程",0]