[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1022235":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},1022235,751,1,"单选题","每串绝缘子的片数在满足操作过电压要求的词时，还应符合工频电压的爬电距离要求，防污设计依照审定的污秽分区和污秽标准分级及爬距要求（见DL\u002FT5092—1999《线路设计规程》附录 B），计算公式为 式中m—每串绝缘子片数； Um——系统最高运行电压，kV; λ——要求的爬电比距，cm\u002FkV； L0——每片悬式绝缘子的几何爬电距离，cm; Kc——式绝缘子的有效系数。 同（2）,但若选用 XPW-160绝缘子（Kc=0.94,L0=40cm,Um=525kV）要求的片数为（）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","28；",false,{"key":16,"text":17,"correct":14},"B","30；",{"key":19,"text":20,"correct":21},"C","37；",true,{"key":23,"text":24,"correct":14},"D","34。","",{"id":6,"name":27,"category":28,"favorite":29},"电气工程师发输变电专业","建筑工程",0]