[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1022113":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},1022113,751,1,"单选题","发电厂高压厂用变压器型号和参数如下：SFFPL:31500\u002F15、31500\u002F16000—16000kV A、15.75±2X2.5\u002F6.3~6.3kV,6kV母线安装为竖放，环境温度按40℃考虑。 选用2 XLMY—100X10母线，在40℃环境温度及母线竖放条件下其综合校正后的载流量为（）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","2460.48A；",false,{"key":16,"text":17,"correct":14},"B","2628.24A；",{"key":19,"text":20,"correct":21},"C","2264.76A；",true,{"key":23,"text":24,"correct":14},"D","2069.04A。","查DL\u002FT 5222—2005附录D表D.11，综合校正系数为0.81。查DL\u002FT5222—2005附录D表D.9，经校正后的载流量2796X0.81=2264.76(A)。",{"id":6,"name":27,"category":28,"favorite":29},"电气工程师发输变电专业","建筑工程",0]