[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1021680":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},1021680,749,1,"单选题","下列关于锅炉水压试验程序的说法中，正确的是（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","缓慢升压至试验压力，至少保持20min，检查是否有泄漏和异常现象",false,{"key":16,"text":17,"correct":14},"B","缓慢升压至试验压力，至少保持20min，再缓慢降压至工作压力进行检查",{"key":19,"text":20,"correct":21},"C","缓慢升压至工作压力，检查是否有泄漏和异常现象，缓慢升压至试验压力，至少保持20min，再缓慢降压至工作压力进行检查",true,{"key":23,"text":24,"correct":14},"D","缓慢升压至工作压力，检查是否有泄漏和异常现象，继续升压至试验压力进行检查，至少保持20min","水压试验内容。缓慢升压至工作压力，检查是否有泄漏或异常现象；继续升压至试验压力，至少保持20min，再缓慢降压至工作压力，检查所有参加水压试验的承压部件表面、焊缝、胀口等处是否有渗漏、变形，以及管道、阀门、仪表等连接部位是否有渗漏。",{"id":6,"name":27,"category":28,"favorite":29},"安全实务-其他安全","建筑工程",0]