[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1019689":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},1019689,744,1,"单选题","下列关于改良蒽醌二磺酸钠（AD A）法脱硫的安全技术要求，说法错误的是（）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","应设溶液事故槽，其容积应大于脱硫塔和再生塔的溶液体积之和",false,{"key":16,"text":17,"correct":18},"B","再生塔与脱硫塔间的溶液管，应设直管，其液面高度应大于煤气计算压力（以mmH 2 0计）加500mm",true,{"key":20,"text":21,"correct":14},"C","进再生塔的压缩空气管和溶液管，均应高于再生塔液面",{"key":23,"text":24,"correct":14},"D","除沫器排水器的冷凝液排放管，应采用不锈钢制作，且不宜有焊缝","改良蒽醌二磺酸钠法脱硫，应遵守下列规定：（1）应设溶液事故槽，其容积应大于脱硫塔和再生塔的溶液体积之和。（2）脱硫塔、再生塔和溶液槽等设备的内壁应进行防腐处理。（3）进再生塔的压缩空气管和溶液管，均应高于再生塔液面，且溶液管上应设防虹吸管或采取其他防虹吸措施。（4）再生塔与脱硫塔间的溶液管，应设U形管，其液面高度应大于鼓风机全压（以mmH 2 0计）加500mm。（5）除沫器排水器的冷凝液排放管，应采用不锈钢制作，且不宜有焊缝。（6）熔硫釜排放硫膏时，其周围严禁明火。",{"id":6,"name":27,"category":28,"favorite":29},"安全实务-金属冶炼安全","建筑工程",0]