[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-739-6":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":610},{"id":5,"name":6,"category":7,"favorite":8},739,"安全实务-建筑施工安全","建筑工程",0,6,50,791,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,310,322,334,346,358,370,382,390,398,410,421,433,445,457,469,481,493,505,517,529,540,551,562,574,586,598],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},1013226,1,"单选题","下列关于脚手板的设置说法中，错误的是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","作业层脚手板应铺满、铺稳",false,{"key":24,"text":25,"correct":22},"B","冲压钢脚手板、木脚手板、竹串片脚手板等，应设置在三根横向水平杆上",{"key":27,"text":28,"correct":22},"C","当脚手板长度小于2m时可采用两根横向水平杆支撑，但应将脚手板两端与其可靠固定，严防倾翻",{"key":30,"text":31,"correct":32},"D","脚手板对接平铺时．接头处必须设一根小横杆",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},1013228,"下列关于单、双排脚手架门洞桁架构造的规定，说法错误的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"单排脚手架门洞处，应在平面桁架的每一节间设置一根斜腹杆",{"key":24,"text":41,"correct":32},"斜腹杆宜采用旋转扣件固定在与之相交的纵向水平杆上",{"key":27,"text":43,"correct":22},"单排脚手架过窗洞时应增设立杆或增设一根纵向水平杆",{"key":30,"text":45,"correct":22},"门洞桁架中伸出上下弦杆的杆件端头，均应增设一个防滑扣件，该扣件宜紧靠主节点处的扣件",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},1013231,"下列关于横向斜撑设置的说法中错误的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"横向斜撑应在同一节间由底至顶呈之字形连续设置",{"key":24,"text":53,"correct":22},"高度在24m以下的封闭型双排脚手架可不设横向斜撑",{"key":27,"text":55,"correct":32},"高度在24m以上的封闭型双排脚手架，可只在拐角处设置横向斜撑",{"key":30,"text":57,"correct":22},"开口型双排脚手架的两端均必须设置横向斜撑",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},1013235,"悬挑式脚手架是指架体结构卸荷在附着于建筑结构的刚性悬挑梁(架)上的脚手架，用于建筑施工中的主体或装修工程的作业及其安全防护需要。悬挑式脚手架搭设符合超过一定规模的危险性较大的分部分项工程的高度为大于等于（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"10m",{"key":24,"text":65,"correct":32},"20m",{"key":27,"text":67,"correct":22},"24m",{"key":30,"text":69,"correct":22},"50m",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":30,"analysis":33},1013237,"下列关于悬挑式脚手架选择和制作的要求中，说法正确的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"当型钢悬挑梁与建筑结构采用螺栓钢压板连接固定时，钢压板尺寸不应小于100mm×10mm",{"key":24,"text":77,"correct":22},"当型钢悬挑梁与建筑结构采用螺栓角钢压板连接时，角钢的规格不应小于100mm×100mm×6mm",{"key":27,"text":79,"correct":22},"悬挑梁型号及锚固件应按设计确定，钢梁截面高度不应小于100mm",{"key":30,"text":81,"correct":32},"钢丝绳与建筑结构拉结的吊环应使用HPB235级钢筋，其直径不宜小于20mm",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":30,"analysis":33},1013240,"操作平台的构造、荷载要求及搭设与拆除，与脚手架相近。为方便施工现场的使用与管理，要求操作平台符合相关脚手架规范和要求。下列不属于施工现场操作平台常见分类的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"移动式操作平台",{"key":24,"text":89,"correct":22},"落地式操作平台",{"key":27,"text":91,"correct":22},"悬挑式操作平台",{"key":30,"text":93,"correct":32},"液压式操作平台",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":27,"analysis":33},1013243,"作业人员在使用操作平台进行施工时，为了防止平台移动宜将立柱与地坪间垫实。因此立柱底部离地面不得超过80mm或行走轮和导向轮应配有制动器或刹车闸等固定措施。下列关于移动式操作平台的要求中，说法错误的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"操作平台采用φ48mm×3．6mm钢管扣件连接，亦可采用门架式部件",{"key":24,"text":101,"correct":22},"操作平台四周必须设置防护栏杆",{"key":27,"text":103,"correct":32},"移动式操作平台在移动时，操作平台上的人员应放低重心，且佩戴安全防护装置",{"key":30,"text":105,"correct":22},"单独设置的操作平台应设置供人上下、踏步间距不大于400mm的扶梯",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":27,"analysis":33},1013245,"悬挑式操作平台可分为斜拉方式的悬挑式操作平台和下支承方式的悬挑式操作平台两种方式。下列关于悬挑式操作平台规定的说法中，错误的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"悬挑式操作平台的搁置点、拉结点、支撑点应设置在主体结构上",{"key":24,"text":113,"correct":22},"悬挑式操作平台的悬挑长度不宜大于5m",{"key":27,"text":115,"correct":32},"悬挑式操作平台的外侧应略低于内侧，外侧应安装固定的防护栏杆并应设置防护挡板完全封闭",{"key":30,"text":117,"correct":22},"不得在悬挑式操作平台吊运、安装时上人",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},1013248,"脚手架的基础可以用十个字概括“平整、夯实、硬化、垫木、排水(沟槽)”，下列关于脚手架安全要求的说法中正确的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"现浇混凝土宽度应超出脚手架宽度两边各10mm以上．待混凝土强度达到70％以上时才可搭设脚手架",{"key":24,"text":125,"correct":32},"底座底面标高以高于自然地坪50mm为宜",{"key":27,"text":127,"correct":22},"地基应里高外低，坡度不少于8％。应沿地基周围设置排水槽",{"key":30,"text":129,"correct":22},"立杆底部垫设垫板时，垫板的长度应不少于5跨",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":30,"analysis":33},1013251,"下列关于脚手架的设计、搭设、使用和维护的表述正确的是（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"结构应稳定，不得发生变形",{"key":24,"text":137,"correct":22},"应满足使用要求，通过其他附加设施实现安全防护功能",{"key":27,"text":139,"correct":22},"在使用中，脚手架结构性能可发生明显改变",{"key":30,"text":141,"correct":32},"当遇意外作用或偶然超载时，不得发生整体破坏",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":30,"analysis":33},1013253,"下列关于木质脚手架材料的说法中，错误的是（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"木杆常用剥皮杉杆或落叶松",{"key":24,"text":149,"correct":22},"木杆立杆和斜杆(包括斜撑、抛撑、剪刀撑等)的小头直径一般不小于70mm",{"key":27,"text":151,"correct":22},"木杆纵向水平杆、横向水平杆的小头一般不小于80mm",{"key":30,"text":153,"correct":32},"木质脚手板的厚度一般不小于30mm",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":30,"analysis":33},1013256,"下列关于竹质脚手架材料的说法中，错误的是（ ）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"竹质立杆、斜撑、顶撑、抛撑、剪刀撑、扫地杆和纵向水平杆的小头一般不小于75mm",{"key":24,"text":161,"correct":22},"竹质纵、横向水平杆的小头不小于90mm",{"key":27,"text":163,"correct":22},"对直径为60～90mm的水平杆杆件，应双杆合并使用",{"key":30,"text":165,"correct":32},"主要受力杆件的使用期限不宜超过3年",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},1013259,"下列关于立杆设置的说法中，错误的是（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"每根立杆底部应设置底座，座下再设垫板",{"key":24,"text":173,"correct":32},"脚手架底层步距不应大于3m",{"key":27,"text":175,"correct":22},"立杆必须用连墙件与建筑物可靠连接",{"key":30,"text":177,"correct":22},"立杆接长除顶层顶部可采用搭接外，其余各层必须采用对接扣件连接",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":27,"analysis":33},1013262,"下列关于连墙杆的设置中，说法错误的是（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":22},"宜靠近主节点设置，偏离主节点的距离不应大于300mm",{"key":24,"text":185,"correct":22},"连墙件应从底层第一步处开始设置，当该处设置有困难时，应采用其他可靠措施固定",{"key":27,"text":187,"correct":32},"连墙件中的连墙杆应向脚手架一端下斜连接",{"key":30,"text":189,"correct":22},"对高度24m以上的双排脚手架，应采用刚性连墙件与建筑物连接",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":30,"analysis":33},1013266,"双排脚手架应设置剪刀撑与横向斜撑，单排脚手架应设置剪刀撑。每道剪刀撑跨越立杆的根数为5～6根，斜杆与地面的倾角应在45°～60°之间。当剪刀撑斜杆与地面的倾角为45°时，剪刀撑跨越立杆的最多根数为（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"4",{"key":24,"text":197,"correct":22},"5",{"key":27,"text":199,"correct":22},"6",{"key":30,"text":201,"correct":32},"7",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":30,"analysis":33},1013268,"下列关于剪刀撑设置的说法中，错误的是（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":22},"剪刀撑斜杆的接长应采用搭接或对接，应用旋转扣件固定，旋转扣件中心线至主节点的距离不应大于150mm",{"key":24,"text":209,"correct":22},"高度在24m及以上的双排脚手架应在外侧全立面连续设置剪刀撑",{"key":27,"text":211,"correct":22},"高度在24m以下的双排脚手架，均必须在外侧两端、转角及中间间隔不超过15m的立面上，各设置一道剪刀撑，并应由底至顶连续设置",{"key":30,"text":213,"correct":32},"高度在24m以下的单排脚手架，可只在外侧两端设置一道剪刀撑",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":24,"analysis":33},1013270,"下列关于悬挑式脚手架选择和制作的要求中，说法错误的是（ ）。",[218,220,222,224],{"key":20,"text":219,"correct":22},"型钢悬挑梁悬挑端应设置能使脚手架立杆与钢梁可靠固定的定位点，定位点离悬挑梁端部不应小于100mm",{"key":24,"text":221,"correct":32},"悬挑架的支承结构应为型钢制作的悬挑梁或悬桁架等，也可采用钢管",{"key":27,"text":223,"correct":22},"悬挑架应水平设置在梁上。锚固位置必须设置主梁或主梁以内的楼板上，不得设置在外伸阳台上或悬挑板上",{"key":30,"text":225,"correct":22},"节点的制作必须采用焊接或螺栓连接的结构，不得采用扣件连接",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":27,"analysis":33},1013273,"移动式操作平台具有独立的机构，可以搬移。常用于构件施工、装修工程和水电安装等作业。下列关于移动式操作平台的设置要求中，正确的是（ ）。",[230,232,234,236],{"key":20,"text":231,"correct":22},"从移动式的特点方面考虑移动式操作平台的面积不应超过30m2",{"key":24,"text":233,"correct":22},"为防止操作平台倾覆。其高度不应超过24m",{"key":27,"text":235,"correct":32},"为保证操作平台整体稳定性其高宽比不应大于3：1",{"key":30,"text":237,"correct":22},"为保证操作平台整体安全其所承受的施工荷载不应超过150kN／m2",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":20,"analysis":33},1013276,"落地式操作平台应独立设置，并应与建筑物进行刚性连接，不得与脚手架连接。下列关于落地式操作平台的要求中，错误的是（ ）。",[242,244,246,248],{"key":20,"text":243,"correct":32},"落地式操作平台的面积不应超过15m2",{"key":24,"text":245,"correct":22},"高度不应超过15m",{"key":27,"text":247,"correct":22},"高宽比不应大于2．5：1",{"key":30,"text":249,"correct":22},"施工平台施工荷载不应超过2．0kN／m2，接料平台的施工荷载不应超过3．0kN／m2",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":24,"analysis":33},1013279,"脚手架拆除时，交替的拆除应从上而下逐层进行，严禁上下同时作业。下列关于脚手架拆除的要求中，错误的是（ ）。",[254,256,258,260],{"key":20,"text":255,"correct":22},"拆除的杆件、构配件应采用机械或人工运至地面，严禁抛掷",{"key":24,"text":257,"correct":32},"同层杆件和构配件必须按先内后外的顺序拆除",{"key":27,"text":259,"correct":22},"剪刀撑、斜撑杆等加固杆件必须在拆卸至该杆件所在部位时再拆除",{"key":30,"text":261,"correct":22},"拆除作业过程中，当架体的自由端高度超过2个步距时，必须采取临时拉结措施",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":27,"analysis":33},1013282,"脚手架工程必须有完善的施工方案。并经企业技术负责人审批。并且有完善的安全防护措施，要按规定设置安全网、防护栏、挡脚板。下列关于脚手架工程的安全技术要求中，说法错误的是（ ）。",[266,268,270,272],{"key":20,"text":267,"correct":22},"操作人员上下架子，要有保证安全的扶梯、爬梯或斜道",{"key":24,"text":269,"correct":22},"必须有良好的防电、避雷装置，钢脚手架等均应可靠接地，高于四周建筑物的脚手架应设避雷装置",{"key":27,"text":271,"correct":32},"脚手板要铺满、铺稳，应保留探头板，并要保证有3个支撑点，并绑扎牢固",{"key":30,"text":273,"correct":22},"遇6级以上大风或大雾、大雨，应暂停高处作业，雨雪后上架操作要有防滑措施",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":24,"analysis":33},1013284,"下列不属于脚手架扣减结构形式的是（ ）。",[278,280,282,284],{"key":20,"text":279,"correct":22},"直角扣件",{"key":24,"text":281,"correct":32},"水平扣件",{"key":27,"text":283,"correct":22},"旋转扣件",{"key":30,"text":285,"correct":22},"对接扣件",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":30,"analysis":33},1013287,"扣件式钢管脚手架的立杆，纵向水平杆、横向水平杆均用扣件连接，它们之间传递荷载利用的是（ ）。",[290,292,294,296],{"key":20,"text":291,"correct":22},"静力",{"key":24,"text":293,"correct":22},"阻力",{"key":27,"text":295,"correct":22},"作用力",{"key":30,"text":297,"correct":32},"摩擦力",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":20,"analysis":33},1013289,"脚手板搭接铺设时，接头必须支在横向水平杆上，搭接长度应大于（ ）mm。",[302,304,306,308],{"key":20,"text":303,"correct":32},"200",{"key":24,"text":305,"correct":22},"400",{"key":27,"text":307,"correct":22},"500",{"key":30,"text":309,"correct":22},"800",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":27,"analysis":33},1013293,"下列关于脚手架立杆说法错误的是（ ）。",[314,316,318,320],{"key":20,"text":315,"correct":22},"搭接长度不应小于1m，应采用不小于两个旋转扣件固定，端部扣件盖板的边缘至杆端距离不应小于100mm",{"key":24,"text":317,"correct":22},"两根相邻立杆的接头不应设置在同步内，同步内隔一根立杆的两个相隔接头在高度方向错开的距离不宜小于500mm",{"key":27,"text":319,"correct":32},"立杆接长除底层底部可采用搭接外，其余各层必须采用对接扣件连接",{"key":30,"text":321,"correct":22},"脚手架立杆顶端栏杆宜高出女儿墙上端1m；宜高出檐口上端1.5m",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":27,"analysis":33},1013295,"悬挑式脚手架的型钢悬挑梁现场多使用（ ）。",[326,328,330,332],{"key":20,"text":327,"correct":22},"角钢",{"key":24,"text":329,"correct":22},"槽钢",{"key":27,"text":331,"correct":32},"工字钢",{"key":30,"text":333,"correct":22},"圆钢",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":24,"analysis":33},1013297,"下列关于操作平台说法错误的是（ ）。",[338,340,342,344],{"key":20,"text":339,"correct":22},"移动式操作平台从移动式的特点方面考虑移动式操作平台的面积不应超过10m2，高度不应超过5m，高宽比不应大于3:1",{"key":24,"text":341,"correct":32},"落地式操作平台的面积不应超过10m2，高度不应超过15m，高宽比不应大于3:1",{"key":27,"text":343,"correct":22},"悬挑式操作平台的悬挑长度不宜大于5m，承载力需经设计验收",{"key":30,"text":345,"correct":22},"当悬挑式操作平台安装时，钢丝绳应采用专用的卡环连接，钢丝绳卡数量应与钢丝绳直径相匹配，且不得少于4个",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":30,"analysis":33},1013301,"下列关于绑扎材料的说法中，错误的是（ ）。",[350,352,354,356],{"key":20,"text":351,"correct":22},"钢丝绑扎木脚手架一般采用8号或10号镀锌钢丝。不得有锈蚀或机械损伤",{"key":24,"text":353,"correct":22},"竹脚手架一般来说应采用竹篾绑扎。竹篾三个月要更换一次",{"key":27,"text":355,"correct":22},"竹竿的绑扎材料严禁重复使用",{"key":30,"text":357,"correct":32},"竹竿的绑扎材料可接长使用",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":30,"analysis":33},1013303,"为建筑施工而搭设的、承受荷载的由扣件和钢管等构成的脚手架与支撑架，统称脚手架。扣件即采用螺栓紧固的扣接连接件。下列关于脚手架的构配件的说法中错误的是（ ）。",[362,364,366,368],{"key":20,"text":363,"correct":22},"脚手架钢管宜采用φ48.3mmx3.6mm钢管。每根钢管的最大质量不应大于25.8kg",{"key":24,"text":365,"correct":22},"扣件在螺栓拧紧扭矩达到65N?m时，不得发生破坏",{"key":27,"text":367,"correct":22},"木胶板脚手板厚度不应小于50mm",{"key":30,"text":369,"correct":32},"可调托撑螺杆与螺母旋合长度不得小于5扣，螺母厚度不得小于10mm",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":30,"analysis":33},1013305,"下列关于脚手架说法错误的是（ ）。",[374,376,378,380],{"key":20,"text":375,"correct":22},"落地作业脚手架.悬挑脚手架的搭设应与工程施工同步，一次搭设高度不应超过最上层连墙件两步，且自由高度不应大于4m",{"key":24,"text":377,"correct":22},"脚手架架体的拆除应从上而下逐层进行，严禁上下同时作业",{"key":27,"text":379,"correct":22},"脚手架设置供操作人员上下使用的安全扶梯.爬梯或斜道",{"key":30,"text":381,"correct":32},"作业脚手架连墙件拆除时先将连墙件整层或数层拆除后再拆架体",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":27,"analysis":33},1013309,"纵向水平杆的对接扣件应交错布置。两根相邻纵向水平杆的接头不宜设置在同步或同跨内；不同步不同跨两相邻接头在水平方向错开的距离不应小于（ ）mm。",[386,387,388,389],{"key":20,"text":303,"correct":22},{"key":24,"text":305,"correct":22},{"key":27,"text":307,"correct":32},{"key":30,"text":309,"correct":22},{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":24,"analysis":33},1013311,"当使用竹笆脚手板时，纵向水平杆应采用直角扣件固定在横向水平杆上，并应等间距设置，间距不应大于（ ）mm。",[394,395,396,397],{"key":20,"text":303,"correct":22},{"key":24,"text":305,"correct":32},{"key":27,"text":307,"correct":22},{"key":30,"text":309,"correct":22},{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":20,"analysis":33},1013314,"某酒店综合改造工程，需要从2 层顶板布设工字钢梁用于搭设悬挑式钢管扣件脚手架，施工单位编制了悬挑脚手架方案。下列关于脚手架方案应计算内容的说法中，正确的是（ ）。",[402,404,406,408],{"key":20,"text":403,"correct":32},"应对悬挑钢梁的抗弯强度.整体稳定性和挠度进行计算",{"key":24,"text":405,"correct":22},"应对悬挑钢梁的抗弯强度.整体稳定性和硬度进行计算",{"key":27,"text":407,"correct":22},"应对悬挑钢梁的抗拉强度.整体稳定性和挠度进行计算",{"key":30,"text":409,"correct":22},"应对悬挑钢梁的抗拉强度.整体稳定性和硬度进行计算",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":27,"analysis":33},1013316,"下列悬挑式脚手架选择和制作说法错误的是（)",[414,416,418,420],{"key":20,"text":415,"correct":22},"悬挑钢梁型号及锚固件应按设计确定，钢梁截面高度不应小于160mm",{"key":24,"text":417,"correct":22},"锚固型钢悬挑梁的U形钢筋拉环或锚固螺栓直径不宜小于16mm",{"key":27,"text":419,"correct":32},"悬挑钢梁悬挑长度应按设计确定，固定段长度不应小于悬挑段长度的1倍",{"key":30,"text":219,"correct":22},{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":20,"analysis":33},1013324,"模板工程的劳动用工约占混凝土工程总用工的1／3。模板通常由3部分组成，分别是（ ）。",[425,427,429,431],{"key":20,"text":426,"correct":32},"模板面、支承结构、连接配件",{"key":24,"text":428,"correct":22},"钢支柱、扣件、脚手板",{"key":27,"text":430,"correct":22},"覆面木胶合板、覆面竹胶合板、复合纤维板",{"key":30,"text":432,"correct":22},"钢材、木材、铝合金",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":20,"analysis":33},1013327,"关于模板的面板材料下列说法错误的是（ ）。",[437,439,441,443],{"key":20,"text":438,"correct":32},"模板的面板只可用钢、木、复合纤维板",{"key":24,"text":440,"correct":22},"覆面木胶合板厚度应采用12～18mm的板材",{"key":27,"text":442,"correct":22},"覆面竹胶合板厚度不小于15mm",{"key":30,"text":444,"correct":22},"复合纤维板厚度应采用12mm及以上板材",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":27,"analysis":33},1013328,"荷载设计值应符合相关规定。荷载分项系数分为永久荷载和活荷载，永久荷载和活荷载的取值分别为（ ）。",[449,451,453,455],{"key":20,"text":450,"correct":22},"0．8；1．0",{"key":24,"text":452,"correct":22},"1．0；1．2",{"key":27,"text":454,"correct":32},"1．2；1．4",{"key":30,"text":456,"correct":22},"1．4；1．6",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":30,"analysis":33},1013330,"拆模时混凝土强度必须符合要求，下列关于模板拆除的说法中，正确的是（ ）。",[461,463,465,467],{"key":20,"text":462,"correct":22},"不承重的侧模板，应根据与结构同条件养护试块强度达到规定，方可拆除",{"key":24,"text":464,"correct":22},"一般墙体大模板在常温条件下，只要混凝土强度能保证其表面及棱角不因拆除模板而受损坏，即可拆除",{"key":27,"text":466,"correct":22},"承重模板。混凝土强度达到1N／mm2即可拆除",{"key":30,"text":468,"correct":32},"在拆模过程中，实际结构混凝土强度并未达到要求，应暂停拆模",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":20,"analysis":33},1013332,"一般现浇楼盖及框架结构的拆模顺序是（ ）。",[473,475,477,479],{"key":20,"text":474,"correct":32},"拆柱模斜撑与柱箍→拆柱侧模→拆楼板底模→拆梁侧模→拆梁底模",{"key":24,"text":476,"correct":22},"拆梁底模→拆梁侧模→拆楼板底模→拆柱侧模→拆柱模斜撑与柱箍",{"key":27,"text":478,"correct":22},"拆柱侧模→拆柱模斜撑与柱箍→拆梁底模→拆梁侧模→拆楼板底模",{"key":30,"text":480,"correct":22},"拆楼板底模→拆梁底模→拆柱模斜撑与柱箍→拆梁侧模→拆柱侧模",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":30,"analysis":33},1013334,"现浇柱模板拆除顺序是（ ）。",[485,487,489,491],{"key":20,"text":486,"correct":22},"拆除斜撑或拉杆(或钢拉条)→拆除竖楞→自上而下拆除柱箍或横楞",{"key":24,"text":488,"correct":22},"自上而下拆除柱箍或横楞→拆除斜撑或拉杆(或钢拉条)→拆除竖楞",{"key":27,"text":490,"correct":22},"自上而下拆除柱箍或横楞→拆除竖楞→拆除斜撑或拉杆(或钢拉条)",{"key":30,"text":492,"correct":32},"拆除斜撑或拉杆(或钢拉条)→自上而下拆除柱箍或横楞→拆除竖楞",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":20,"analysis":33},1013336,"模板安装应按设计与施工说明书循序拼装。下列关于模板施工的技术要求中，说法错误的是（ ）。",[497,499,501,503],{"key":20,"text":498,"correct":32},"竖向模板和支架支承部分安装在基土上时，可不加设垫板",{"key":24,"text":500,"correct":22},"模板安装时，上下应有人接应，随装随运，严禁抛掷",{"key":27,"text":502,"correct":22},"五级风及其以上应停止一切吊运作业",{"key":30,"text":504,"correct":22},"严禁将模板与井字架脚手架或操作平台连成一体",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":30,"analysis":33},1013337,"模板工程的施工安全的重要性尤为突出，下列不属于模板分类的是（ ）。",[509,511,513,515],{"key":20,"text":510,"correct":22},"定型组合模板",{"key":24,"text":512,"correct":22},"墙体大模板",{"key":27,"text":514,"correct":22},"飞模",{"key":30,"text":516,"correct":32},"自提升式钢模板",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":30,"analysis":33},1013339,"模板的结构设计，必须能承受作用于模板结构上的所有垂直荷载和水平荷载。在所有可能产生的荷载中要选择最不利的组合验算模板整体结构和构件及配件的参数不包括（ ）。",[521,523,525,527],{"key":20,"text":522,"correct":22},"稳定性",{"key":24,"text":524,"correct":22},"刚度",{"key":27,"text":526,"correct":22},"强度",{"key":30,"text":528,"correct":32},"挠度",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":30,"analysis":33},1013341,"模板的结构设计，必须保证能承受作用于模板结构上的所有垂直荷载和水平荷载，在可能产生的荷载中，应选择最不利的组合验算模板整体结构，以及构件、配件的强度、刚度和（ ）。",[533,535,537,539],{"key":20,"text":534,"correct":22},"高度",{"key":24,"text":536,"correct":22},"宽度",{"key":27,"text":538,"correct":22},"组合性",{"key":30,"text":522,"correct":32},{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":542,"options":543,"answer":30,"analysis":33},1013343,"下列模板安装做法错误的是（ ）",[544,545,547,549],{"key":20,"text":502,"correct":22},{"key":24,"text":546,"correct":22},"采用扣件式钢管脚手架作立柱支撑时，立杆接长必须采用对接，主立杆间距不得大于1m，纵横杆步距不应大于1.2m",{"key":27,"text":548,"correct":22},"模板及其支架在安装过程中，必须设置有效防倾覆的临时固定设施",{"key":30,"text":550,"correct":32},"现浇钢筋混凝土梁.板，当跨度大于6m时，模板应起拱",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":24,"analysis":33},1013344,"模板拆除作业的顺序和方法应根据模板工程专项施工方案实施。一般现浇楼板及框架拆模的正确顺序是（ ）。",[555,557,558,560],{"key":20,"text":556,"correct":22},"A拆柱模斜撑与柱箍→拆楼板底模→拆柱侧模→拆梁侧模→拆梁底模",{"key":24,"text":474,"correct":32},{"key":27,"text":559,"correct":22},"拆柱模斜撑与柱箍→拆柱侧模→拆梁侧模→拆楼板底模→拆梁底模",{"key":30,"text":561,"correct":22},"拆柱模斜撑与柱箍→拆梁侧模→拆柱侧模→拆楼板底模→拆梁底模",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":30,"analysis":33},1013346,"某公司采用机械拆除方式拆除框架结构建筑物。根据《建筑拆除工程安全技术规范》（JGJ147），拆除的正确顺序是（ ）。",[566,568,570,572],{"key":20,"text":567,"correct":22},"次梁.主梁.楼板.柱子",{"key":24,"text":569,"correct":22},"主梁.次梁.楼板.柱子",{"key":27,"text":571,"correct":22},"楼板.主梁.次梁.柱子",{"key":30,"text":573,"correct":32},"楼板.次梁.主梁.柱子",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":27,"analysis":33},1013348,"对模板施工单位进行全面的安全技术交底，施工单位应是具有资质的单位。下列关于模板施工的规定中，错误的是（ ）。",[578,580,582,584],{"key":20,"text":579,"correct":22},"现浇钢筋混凝土梁.板，当跨度大于4m时，模板应起拱",{"key":24,"text":581,"correct":22},"当层间高度大于5m时，宜选用桁架支模或多层支架支模",{"key":27,"text":583,"correct":32},"模板安装作业高度超过5m时，才须搭设脚手架或平台",{"key":30,"text":585,"correct":22},"拼装高度为2m以上的竖向模板，不得站在下层模板上拼装上层模板",{"id":587,"libraryId":5,"type":15,"typeLabel":16,"stem":588,"options":589,"answer":24,"analysis":33},1013350,"下列不属于模板载荷标准值的是（ ）。",[590,592,594,596],{"key":20,"text":591,"correct":22},"恒荷载标准值",{"key":24,"text":593,"correct":32},"雪荷载标准值",{"key":27,"text":595,"correct":22},"风荷载标准值",{"key":30,"text":597,"correct":22},"活荷载标准值",{"id":599,"libraryId":5,"type":15,"typeLabel":16,"stem":600,"options":601,"answer":27,"analysis":33},1013352,"下列关于模板载荷规定说法错误的是（ ）。",[602,604,606,608],{"key":20,"text":603,"correct":22},"对于承载能力极限状态，荷载组合应按荷载效应的基本组合采用",{"key":24,"text":605,"correct":22},"荷载分项系数：永久荷载为1.2，活荷载为1.4",{"key":27,"text":607,"correct":32},"对结构表面外露的模板，其最大变形值不得超过模板构件计算跨度的1\u002F1000",{"key":30,"text":609,"correct":22},"对于正常使用极限状态荷载组合应采用标准组合",[611,614,617,620,623,626],{"id":15,"name":612,"category":7,"favorite":613},"领导干部任职前廉政法规知识测试题",92,{"id":615,"name":616,"category":7,"favorite":15},595,"建筑结构与设备",{"id":618,"name":619,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":621,"name":622,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":624,"name":625,"category":7,"favorite":8},534,"BIM工程师",{"id":627,"name":625,"category":7,"favorite":8},535]