[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1013119":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},1013119,739,1,"单选题","当基坑支护结构监测数据出现异常情况时，必须及时进行危险报警，并对基坑支护结构和周边环境中的保护对象采取应急措施。下列情况中不属于应当采取应急措施的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","监测数据达到检测报警值的累计值",false,{"key":16,"text":17,"correct":18},"B","基坑出现渗漏",true,{"key":20,"text":21,"correct":14},"C","基坑支护结构的支撑或锚杆体系出现过大变形、压屈、断裂、松弛或拔出的迹象",{"key":23,"text":24,"correct":14},"D","周边管线出现裂缝、泄漏等","当出现下列情况之一时，必须进行危险报警，并对基坑支护结构和周边环境中的保护对象采取应急措施： (1)监测数据达到检测报警值的累计值。 (2)基坑出现流沙、管涌、隆起、陷落或较严重的渗漏等。 (3)基坑支护结构的支撑或锚杆体系出现过大变形、压屈、断裂、松弛或拔出的迹象。 (4)周边建筑的结构部分、周边地面出现较严重的突发裂缝或危害结构的变形裂缝。 (5)周边管线变形突然明显增长或出现裂缝、泄漏等。 (6)根据当地工程经验判断，出现其他必须进行危险报警的情况。",{"id":6,"name":27,"category":28,"favorite":29},"安全实务-建筑施工安全","建筑工程",0]