[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1013039":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},1013039,739,1,"单选题","下列关于竖向洞口防护措施的说法中，正确的是（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","当竖向空口的短边边长小于1200mm时，应采取封堵措施",false,{"key":16,"text":17,"correct":14},"B","当垂直洞口短边边长大于或等于1200mm时，应在临空一侧设置高度不低于1500mm防护栏杆，并应采用密目式安全立网或工具式栏板封闭，设置挡脚板",{"key":19,"text":20,"correct":21},"C","竖向结构高度大于等于600mm且小于1200mm的预留洞口，应设置1200mm高的防护栏杆",true,{"key":23,"text":24,"correct":14},"D","竖向结构高度大于等于600mm且小于1200mm的预留洞口，应在距地面不高于20mm处设置一道防护栏杆","当竖向空口的短边边长小于500 mm时，应采取封堵措施；当垂直洞口短边边长大于或等于500 mm时，应在临空一侧设置高度不低于1200 mm防护栏杆，并应采用密目式安全立网或工具式栏板封闭，设置挡脚板；竖向结构高度大于(含)600 mm且小于1200 mm的预留洞口安全防护措施应满足如下要求：防护栏杆采用648．3 mm×3．6 mm钢管，在距离地面或楼面1200 mm处设置一道，并在其下方距竖向结构不大于20 mm处设置一道。",{"id":6,"name":27,"category":28,"favorite":29},"安全实务-建筑施工安全","建筑工程",0]