[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-1004984":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},1004984,736,1,"单选题","为保证检修动火和进设备内作业安全，在检修范围内的所有设备和管线中的易燃、易爆、有毒有害气体应进行置换。用惰性气体作置换介质时，必须保证惰性气体用量为被置换介质容积的3倍以上。但是，置换是否彻底，置换作业是否已经符合安全要求，最终应根据（ ）判断是否合格。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","置换时间",false,{"key":16,"text":17,"correct":14},"B","介质用量",{"key":19,"text":20,"correct":21},"C","取样分析",true,{"key":23,"text":24,"correct":14},"D","温度变化","置换要求用水作为置换介质时，一定要保证设备内注满水，且在设备顶部最高处溢流口有水溢出，并持续一段时间，严禁注水未满。用惰性气体作置换介质时，必须保证惰性气体用量(一般为被置换介质容积的3倍以上)。但是，置换是否彻底，置换作业是否已符合安全要求，不能只根据置换时间的长短或置换介质的用量，而应根据取样分析是否合格为准。置换作业排出的气体应引入安全场所。如需检修动火，置换用惰性气体中氧含量一般小于1％～2％(体积百分浓度)。",{"id":6,"name":27,"category":28,"favorite":29},"安全实务-化工安全","建筑工程",0]