[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-732-14":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":621},{"id":5,"name":6,"category":7,"favorite":8},732,"安全生产专业实务(原案例)","建筑工程",0,14,50,1210,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,310,322,334,346,358,370,382,394,406,418,430,442,454,466,478,490,502,514,526,538,549,561,573,585,597,609],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},997399,1,"单选题","下列冷轧生产线预防跌倒及高处坠落的控制措施当中，说法错误的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","冷轧机出入口地面必须设置钢板，涂刷耐磨防腐漆",true,{"key":24,"text":25,"correct":26},"B","酸连轧机组开卷机、卷取机扇形块检修必须设置好安全跳板",false,{"key":28,"text":29,"correct":26},"C","镀锌机组退火炉换辊检修时，活动栏杆拆除后，指吊人员必须佩戴安全带作业",{"key":31,"text":32,"correct":26},"D","步进梁深坑应设法铺设伸缩盖板","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},997400,"下列冷轧生产线的安全技术措施，属于防止火灾发生的技术是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"供电主控室按相关标准设置火灾自动报警器",{"key":24,"text":41,"correct":26},"电缆进出穿线时预留孔洞应用防火泥密封",{"key":28,"text":43,"correct":26},"整流及动力变压器设施应设置防火墙",{"key":31,"text":45,"correct":22},"镀层与涂层的溶剂室必须采用防爆型电气设备",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},997401,"不属于冷轧生产过程中产生的事故类型是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"触电",{"key":24,"text":53,"correct":22},"淹溺",{"key":28,"text":55,"correct":26},"灼烫",{"key":31,"text":57,"correct":26},"机械伤害",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},997402,"现场惰性气体气瓶存放处、氮气通往现场作业线的第一道阀门处必须设置的警告标识是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"当心中毒",{"key":24,"text":65,"correct":26},"当心爆炸",{"key":28,"text":67,"correct":22},"当心窒息",{"key":31,"text":69,"correct":26},"必须强制通风",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},997403,"下列关于氨气泄漏应采取的应急措施，说法正确的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"操作工处理氨气泄漏时，为避免伤亡扩大，必须一人单独进行堵漏操作",{"key":24,"text":77,"correct":26},"操作工处理氨气泄漏时，按要求佩戴过滤式呼吸器",{"key":28,"text":79,"correct":22},"操作工应穿戴防静电服、防静电鞋",{"key":31,"text":81,"correct":26},"维护检修人员必须按要求使用钢质工具",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":28,"analysis":33},997404,"下列关于精整工艺中，防止机械伤害的控制措施，说法错误的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"严禁触摸精整设备轧辊等入口、出口的所有旋转部件",{"key":24,"text":89,"correct":26},"入口开卷、出口卷取区域运行部件多，采用集中式的安全互锁按钮集中控制",{"key":28,"text":91,"correct":22},"检查轧辊表面缺陷时，作业人员应在轧辊转动的正方向进行作业",{"key":31,"text":93,"correct":26},"上下卷时，不准站在移动小车上跟随作业",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},997405,"下列不属于精整工序主要设备的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"矫直机",{"key":24,"text":101,"correct":26},"纵剪",{"key":28,"text":103,"correct":26},"横剪",{"key":31,"text":105,"correct":22},"飞剪",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":28,"analysis":33},997406,"下列关于防止叉车车辆伤害的控制措施，说法正确的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":26},"叉车司机应持特种作业证上岗",{"key":24,"text":113,"correct":26},"叉车装载物品较重，有前倾趋势，叉车尾部应站人配重",{"key":28,"text":115,"correct":22},"斜坡处不斜向行驶",{"key":31,"text":117,"correct":26},"叉车前方物品较高，应减速行驶",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},997407,"下列防止天然气火灾的控制措施，说法错误的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"对天然气可能泄漏的部位，用点火器点火试验的方法进行检查",{"key":24,"text":125,"correct":26},"在车间生产设备总燃气管道的一端引出一根排气管道，应高出屋顶2 m",{"key":28,"text":127,"correct":26},"在有燃气存在的条件下进行维修工作，检修工具采用铜质工具",{"key":31,"text":129,"correct":26},"在停送天然气放散时，放散管周围40 m内不准有明火存在",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":31,"analysis":33},997408,"下列关于氯气的安全控制措施，说法正确的是（ ）",[134,136,138,140],{"key":20,"text":135,"correct":26},"氯气生产设备在不能采用自然通风的场所，应采用机械循环通风",{"key":24,"text":137,"correct":26},"液氯生产系统必须设置事故氯吸收装置，具备独立电源和12h能连续运行的能力",{"key":28,"text":139,"correct":26},"固定式和便携式氯气检测报警仪的报警设定值为10mg／m3",{"key":31,"text":141,"correct":22},"工作场所应在便于观察处设置醒目的风向标．并且具备夜间可视效果",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},997409,"在拉拔生产工艺中，关于水压机的安全技术措施，下列说法正确的是（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":26},"水压机开动前首先要确认回水阀门已经关闭．否则不能开动设备",{"key":24,"text":149,"correct":22},"换水压机压挤筒前，必须把低压罐中的压缩空气放掉",{"key":28,"text":151,"correct":26},"停水压机时，一定要先停低压阀门后停高压阀门",{"key":31,"text":153,"correct":26},"挤压动作完成，制品压出后，只能俯视制品",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":28,"analysis":33},997410,"下列锻压机的安全技术措施，说法错误的是（ ）。",[158,160,162,164],{"key":20,"text":159,"correct":26},"锻压机动作开关宜设计成双按钮",{"key":24,"text":161,"correct":26},"用工具往锻压机运送小型锻件时，要确认锻件夹牢",{"key":28,"text":163,"correct":22},"锻压作业时，人员必须靠近锻件",{"key":31,"text":165,"correct":26},"工作中禁止到活动梁下部探视冲模及半成品",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":20,"analysis":33},997411,"下列关于天然气的理化性质，说法错误的是（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"天然气的主要成分和瓦斯不同",{"key":24,"text":173,"correct":26},"天然气的爆炸极限为4％～15％",{"key":28,"text":175,"correct":26},"天然气的密度比空气小",{"key":31,"text":177,"correct":26},"天然气无色无味，增大了其危害性",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":31,"analysis":33},997412,"下列防止工业燃油着火的安全技术措施，说法错误的是（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":26},"在点燃烧嘴前应先通入一段时间空气，然后供给重油",{"key":24,"text":185,"correct":26},"最好采用电点燃等先进安全的点火方法",{"key":28,"text":187,"correct":26},"小于5 m3的消耗油罐可以放在车间内，但与炉子距离不应小于1．5 m",{"key":31,"text":189,"correct":22},"重油炉的车间内要配备灭火栓和消防水池",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":28,"analysis":33},997413,"下列防止铝液爆炸的控制措施，说法正确的是（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":26},"过滤除气装置放干放流口应备有该装置等量金属液容量的放干箱",{"key":24,"text":197,"correct":26},"熔炼炉上方应设置天窗",{"key":28,"text":199,"correct":22},"铸造机升降平台不应有储水空间",{"key":31,"text":201,"correct":26},"熔炼炉放流口应备有塞棒，每个眼备用一根，并定期检查记录",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":28,"analysis":33},997414,"煤气爆炸必须具备三个条件，下列内容不属于该条件的是（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":26},"煤气和空气(氧气)在煤气管道、设备或炉窑里混合",{"key":24,"text":209,"correct":26},"煤气浓度达到爆炸极限",{"key":28,"text":211,"correct":22},"空气要足够干燥",{"key":31,"text":213,"correct":26},"要有激发能源",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":31,"analysis":33},997415,"所谓煤气中毒是指一氧化碳中毒，一氧化碳是一种（ ）。",[218,220,222,224],{"key":20,"text":219,"correct":26},"致幻性毒物",{"key":24,"text":221,"correct":26},"麻醉性毒物",{"key":28,"text":223,"correct":26},"脑脊髓功能障碍性毒物",{"key":31,"text":225,"correct":22},"窒息性毒物",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":24,"analysis":33},997416,"将可燃气体控制在爆炸极限范围以外的措施，在安全工作中得到广泛应用，同时我们发现，可燃气体爆炸极限的下限越低，其爆炸的可能性越大。下列各种煤气爆炸极限的下限最低的是（ ）。",[230,232,234,236],{"key":20,"text":231,"correct":26},"高炉煤气",{"key":24,"text":233,"correct":22},"焦炉煤气",{"key":28,"text":235,"correct":26},"转炉煤气",{"key":31,"text":237,"correct":26},"发生炉煤气",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":31,"analysis":33},997417,"依据《工业企业煤气安全规定》(GB 6222)的规定，下列煤气加压站与混合站的安全要求，说法错误的是（ ）。",[242,244,246,248],{"key":20,"text":243,"correct":26},"煤气加压站应建立在地面上，禁止在厂房下设地下室或半地下室",{"key":24,"text":245,"correct":26},"煤气混合站如为两层建筑物，上层高度不得低于3．5 m，下层高度不得低于3 m",{"key":28,"text":247,"correct":26},"如用户允许间断供应煤气，煤气加压机械可设一路电源",{"key":31,"text":249,"correct":22},"煤气混合站内主机与墙壁之间如用作主要通道，净距不应小于1．3 m",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":28,"analysis":33},997418,"架空煤气管道(上方通过)与铁路、道路和其他管线的最小垂直净距，不符合规定的是（ ）。",[254,256,258,260],{"key":20,"text":255,"correct":26},"架空煤气管道与1 kv以下架空电力线路外侧边缘的最小垂直净距是1．5m",{"key":24,"text":257,"correct":26},"架空煤气管道与1～30 kV架空电力线路外侧边缘的最小垂直净距是3．0 m",{"key":28,"text":259,"correct":22},"架空煤气管道与35～110 kV架空电力线路外侧边缘的最小垂直净距是6．0 m",{"key":31,"text":261,"correct":26},"架空煤气管道与φ320 mm燃油管的最小垂直净距是0．3 m",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":31,"analysis":33},997419,"煤气隔断装置是重要的生产装置，也是重要的安全装置。下列隔断装置属于“能单独使用作为可靠隔断装置”的是（ ）。",[266,268,270,272],{"key":20,"text":267,"correct":26},"闸阀",{"key":24,"text":269,"correct":26},"密封蝶阀",{"key":28,"text":271,"correct":26},"水封",{"key":31,"text":273,"correct":22},"盲板",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":31,"analysis":33},997420,"下列关于煤气管道强度试验的说法，正确的是（ ）。",[278,280,282,284],{"key":20,"text":279,"correct":26},"煤气管道强度试验的压力介质是煤气",{"key":24,"text":281,"correct":26},"煤气管道强度试验的压力介质是空气",{"key":28,"text":283,"correct":26},"埋地管道的试验压力是设计压力的1．15倍",{"key":31,"text":285,"correct":22},"强度试验压力应逐级缓慢升压，压力首先升至试验压力的50％",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":20,"analysis":33},997421,"煤气混合站和加压站的建筑物属于防火防爆区域，按可燃气体爆炸极限下限可以分为甲、乙两类火灾危险性，其中爆炸下限小于10％的可燃气体具有甲类火灾危险性，爆炸下限大于或等于10％的可燃气体属于乙类火灾危险性。下列区域火灾危险性属于甲类的是（ ）。",[290,292,294,296],{"key":20,"text":291,"correct":22},"焦炉煤气加压站主厂房",{"key":24,"text":293,"correct":26},"转炉煤气抽气机室",{"key":28,"text":295,"correct":26},"发生炉煤气加压站主厂房",{"key":31,"text":297,"correct":26},"煤气混合站管理室",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":28,"analysis":33},997422,"依据《工业企业煤气安全规定》(GB 6222)关于煤气管道敷设的规定，下列说法正确的是（ ）。",[302,304,306,308],{"key":20,"text":303,"correct":26},"煤气管道应埋地敷设，最大程度减少煤气泄漏危害",{"key":24,"text":305,"correct":26},"管道下面经常有装载炽热物件的车辆停留时，应采取喷淋措施",{"key":28,"text":307,"correct":22},"不应穿过不使用煤气的建筑物、办公室以及通风不良的地点",{"key":31,"text":309,"correct":26},"其他管道的支吊架应直接焊接在煤气管道外壁上",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":24,"analysis":33},997423,"在一般情况下，下列架空煤气管道与建筑物、铁路、道路和其他管线的最小水平净距，不符合规定的是（ ）。",[314,316,318,320],{"key":20,"text":315,"correct":26},"架空煤气管道与道路(路肩)的最小水平净距是1．5 m",{"key":24,"text":317,"correct":22},"架空煤气管道与房屋建筑的最小水平净距是1．5 m",{"key":28,"text":319,"correct":26},"架空煤气管道与1 kV以下架空电力线路外侧边缘的最小水平净距是1．5 m",{"key":31,"text":321,"correct":26},"架空煤气管道与其他地下平行敷设管道的最小水平净距是1．5 m",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":20,"analysis":33},997424,"下列关于湿式煤气柜的安全要求，依据《工业企业煤气安全规定》(GB6222)，说法正确的是（ ）。",[326,328,330,332],{"key":20,"text":327,"correct":22},"湿式柜每级塔间水封的有效高度应不小于最大工作压力的1.5倍",{"key":24,"text":329,"correct":26},"湿式柜出人口管道上应设隔断装置，出入口管道最高处应设排水器",{"key":28,"text":331,"correct":26},"湿式柜安装完毕，应进行至少一次升降试验",{"key":31,"text":333,"correct":26},"有条件的企业可进行快速升降试验，没有条件的企业可只做快速升起试验",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":24,"analysis":33},997425,"下列关于在煤气设备内部进行检维修作业的说法，正确的是（ ）。",[338,340,342,344],{"key":20,"text":339,"correct":26},"一氧化碳含量不超过50 mg／m3时，可较长时间工作",{"key":24,"text":341,"correct":22},"一氧化碳含量不超过100 mg／m3时，入内连续工作时间不应超过0．5 h",{"key":28,"text":343,"correct":26},"工作人员每次进入设施内部工作的时间间隔至少在1 h以上",{"key":31,"text":345,"correct":26},"工作中断0．5 h后，应重新分析一氧化碳及氧气含量",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":24,"analysis":33},997426,"带压带煤气抽堵盲板作业危险性很大，下列关于安全作业的说法，正确的是（ ）。",[350,352,354,356],{"key":20,"text":351,"correct":26},"抽堵盲板前应采取措施使作业段煤气压力稳定至设计压力",{"key":24,"text":353,"correct":22},"抽堵盲板作业区40 m以内禁止存在火源或高温热源",{"key":28,"text":355,"correct":26},"距火源较近的地点进行抽堵盲板作业时，保持煤气在正压状态下方可操作",{"key":31,"text":357,"correct":26},"参加抽堵盲板作业人员应佩戴负压呼吸器，穿化纤服",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":31,"analysis":33},997427,"下列关于煤气点火设施的说法，错误的是（ ）。",[362,364,366,368],{"key":20,"text":363,"correct":26},"炉子点火时，炉内燃烧系统应具有一定的负压，点火程序必须是先点燃火种后给煤气",{"key":24,"text":365,"correct":26},"送煤气前已烘炉的炉子，其炉膛温度超过800℃时，可不点火直接送煤气，但应严密监视其是否燃烧",{"key":28,"text":367,"correct":26},"强制送风的炉子，点火时应先开鼓风机但不送风，待点火送煤气燃着后，再逐步增大供风量和煤气量",{"key":31,"text":369,"correct":22},"停煤气时，应先停鼓风机，然后关闭所有的烧嘴",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":31,"analysis":33},997428,"下列气体检测器的设置中，说法正确的是（ ）。",[374,376,378,380],{"key":20,"text":375,"correct":26},"可燃气体或含有毒气体的可燃气体泄漏时，可燃气体浓度可能达到25％爆炸下限，但有毒气体不能达到最高容许浓度时，应设置有毒气体检测器",{"key":24,"text":377,"correct":26},"有毒气体或含有可燃气体的有毒气体泄漏时，有毒气体浓度可能达到最高容许浓度，但可燃气体浓度不能达到25％爆炸下限时，应设置可燃气体检测器",{"key":28,"text":379,"correct":26},"可燃气体与有毒气体同时存在的场所，可燃气体浓度可能达到25％爆炸下限，有毒气体的浓度也可能达到最高容许浓度时，应只设置可燃气体",{"key":31,"text":381,"correct":22},"同一种气体，既属于可燃气体又属于有毒气体时，应只设置有毒气体检测器",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":28,"analysis":33},997429,"下列不属于煤气安全检测方法的是（ ）。",[386,388,390,392],{"key":20,"text":387,"correct":26},"电化学传感器检测法",{"key":24,"text":389,"correct":26},"光谱吸收法",{"key":28,"text":391,"correct":22},"金相分析",{"key":31,"text":393,"correct":26},"气相色谱分析法",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":20,"analysis":33},997430,"下列属于高压氧舱绝对禁忌证的是（ ）。",[398,400,402,404],{"key":20,"text":399,"correct":22},"未经处理的气胸",{"key":24,"text":401,"correct":26},"明显肺气肿",{"key":28,"text":403,"correct":26},"女性月经期",{"key":31,"text":405,"correct":26},"有氧中毒史",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":20,"analysis":33},997431,"下列关于煤气意外着火应采取的应急措施，说法正确的是（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"煤气管道直径在100 mm以下的可直接切断煤气灭火",{"key":24,"text":413,"correct":26},"管道直径大于100 mm的应逐渐降低煤气压力，但煤气压力不应低于50 Pa，不应突然关闭煤气阀门",{"key":28,"text":415,"correct":26},"在通风不良的场所，应第一时间快速灭火，随后降低煤气压力",{"key":31,"text":417,"correct":26},"煤气设施已烧红时，应用水快速冷却，以防煤气设施烧穿而泄漏出煤气",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":20,"analysis":33},997432,"逃生呼吸器适用于现场紧急情况下使用，其应急有效时间大约是（ ）。",[422,424,426,428],{"key":20,"text":423,"correct":22},"10 min",{"key":24,"text":425,"correct":26},"1 h",{"key":28,"text":427,"correct":26},"2 h",{"key":31,"text":429,"correct":26},"3 h",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":31,"analysis":33},997433,"实现氧氮分离的工艺是（ ）。",[434,436,438,440],{"key":20,"text":435,"correct":26},"低温液体泵",{"key":24,"text":437,"correct":26},"换热器",{"key":28,"text":439,"correct":26},"膨胀机",{"key":31,"text":441,"correct":22},"精馏塔",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":24,"analysis":33},997434,"空气分离的基本方法不包括（ ）。",[446,448,450,452],{"key":20,"text":447,"correct":26},"深度冷冻法",{"key":24,"text":449,"correct":22},"燃烧法",{"key":28,"text":451,"correct":26},"吸附法",{"key":31,"text":453,"correct":26},"膜分离法",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":28,"analysis":33},997435,"下列关于氧气管道安全控制措施的说法，错误的是（ ）。",[458,460,462,464],{"key":20,"text":459,"correct":26},"架空氧气管道与明火地点等之间的最小净距不应小于10 m",{"key":24,"text":461,"correct":26},"氧气管道与乙炔管道共架敷设时，应设在乙炔管道的下方",{"key":28,"text":463,"correct":22},"氧气管道与油质管道同沟敷设时，应设在乙炔管道的下方",{"key":31,"text":465,"correct":26},"氧气管道上的法兰连接和螺纹连接处，应用金属导线跨接，跨接电阻应小于0．03Ω",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":24,"analysis":33},997436,"下列纯净气体中，会导致中毒症状的是（ ）。",[470,472,474,476],{"key":20,"text":471,"correct":26},"氮气",{"key":24,"text":473,"correct":22},"氧气",{"key":28,"text":475,"correct":26},"氩气",{"key":31,"text":477,"correct":26},"氙气",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":24,"analysis":33},997437,"下列关于氢气的安全控制措施的说法，错误的是（ ）。",[482,484,486,488],{"key":20,"text":483,"correct":26},"每天至少应测量一次电解槽的极间电压",{"key":24,"text":485,"correct":22},"在氢气管道最高点处设放散管，并在管口处设点火器",{"key":28,"text":487,"correct":26},"保证氢气纯度和氧气纯度均不低于99．5％",{"key":31,"text":489,"correct":26},"接触氢气的阀门不应采用铜和铜合金材料",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":31,"analysis":33},997438,"下列可燃气体当中，燃烧所需点火能量最小的是（ ）。",[494,496,498,500],{"key":20,"text":495,"correct":26},"一氧化碳",{"key":24,"text":497,"correct":26},"甲烷",{"key":28,"text":499,"correct":26},"乙炔",{"key":31,"text":501,"correct":22},"氢气",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":28,"analysis":33},997439,"下列关于气瓶在运输车辆上采取的安全措施，说法错误的是（ ）。",[506,508,510,512],{"key":20,"text":507,"correct":26},"氧气瓶不可与可燃气瓶同车",{"key":24,"text":509,"correct":26},"气瓶立放时车厢高度应在瓶高的2／3以上",{"key":28,"text":511,"correct":22},"卧放时，瓶阀端应交替错开",{"key":31,"text":513,"correct":26},"夏季时气瓶要防晒",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":20,"analysis":33},997440,"工业养护率生产工艺主要用碱法，碱法生产氧化铝按照生产过程的特点，又分为拜耳法、烧结法、拜耳一烧结联合法(包括并联、串联、混联)。生产过程中，使用苛性碱溶液在一定温度、一定压力条件下溶出铝土矿，氧化铝被溶出制得铝酸钠溶液，铝酸钠溶液净化后经过降温、添加晶种、搅拌分解析出的氢氧化铝，经分离、洗涤、焙烧后得到氧化铝。上述方法属于碱法生产中的（ ）。",[518,520,522,524],{"key":20,"text":519,"correct":22},"拜耳法",{"key":24,"text":521,"correct":26},"烧结法",{"key":28,"text":523,"correct":26},"串联法",{"key":31,"text":525,"correct":26},"并联法",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":28,"analysis":33},997441,"铝主要以铝硅酸盐矿存在，氧化铝生产过程就是从铝矿石中提取氧化铝使之与杂质分离的过程。氧化铝生产方法大致可分为四类，下列不属于这四类的生产方法是（ ）。",[530,532,534,536],{"key":20,"text":531,"correct":26},"碱法",{"key":24,"text":533,"correct":26},"酸法",{"key":28,"text":535,"correct":22},"电解法",{"key":31,"text":537,"correct":26},"热法",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":20,"analysis":33},997442,"氧化铝原料制备过程中会产生二氧化硅、氧化钙、一氧化碳、二氧化碳等有害物质，这些物质中能够导致尘肺病的是（ ）。",[542,544,546,547],{"key":20,"text":543,"correct":22},"二氧化硅",{"key":24,"text":545,"correct":26},"氧化钙",{"key":28,"text":495,"correct":26},{"key":31,"text":548,"correct":26},"二氧化碳",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":24,"analysis":33},997443,"磨机在使用时周围应设置完好的护栏、平台，应设置慢转驱动装置。下列关于磨机使用安全技术的说法，错误的是（ ）。",[553,555,557,559],{"key":20,"text":554,"correct":26},"磨机的转动部位、管道法兰等部位应设置防护罩",{"key":24,"text":556,"correct":22},"磨机运行时，禁止用钢钎等物捅料口，环形筛和排矿流槽杂物应及时清理",{"key":28,"text":558,"correct":26},"进入磨机之前应提前数小时停车降温，办理工作票",{"key":31,"text":560,"correct":26},"磨机现场应设置隔噪声操作室，作业人员应配备防噪耳塞",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":28,"analysis":33},997444,"下列熟料窑安全防范措施的说法中，正确的是（ ）。",[565,567,569,571],{"key":20,"text":566,"correct":26},"熟料窑新换耐火砖点火烘窑时，应关闭窑尾立烟道门",{"key":24,"text":568,"correct":26},"熟料窑点火时现场人员应站在窑口正面稍远距离，观察窑内情况",{"key":28,"text":570,"correct":22},"捣下料口时，不应正面对着工具或把工具抱在怀里",{"key":31,"text":572,"correct":26},"打窑圈时，打圈作业人应站在窑圈正下方作业",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":28,"analysis":33},997445,"母液蒸发工序主要设备设施有蒸发器、储槽等。下列关于蒸发器安全技术措施的说法，正确的是（ ）。",[577,579,581,583],{"key":20,"text":578,"correct":26},"蒸汽缓冲器、新蒸汽总管上每处应设置1个安全阀",{"key":24,"text":580,"correct":26},"蒸发器组停车超过4 h以上，重新开车通蒸汽前须先通风15 min",{"key":28,"text":582,"correct":22},"蒸发器运转中，严禁用水冲洗液位计表面和用冷水冲洗目镜，严禁带压紧固目镜螺栓",{"key":31,"text":584,"correct":26},"蒸发器内温度40℃以下方可进入，照明应使用安全灯，电压不得大于36 V",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":31,"analysis":33},997446,"氧化铝生产设备、设施主要有固体输送设备、流体输送设备、磨矿及分级设备、煅烧设备、液固分离设备、压力容器、起重设备、除尘设备、其他相关设施等。氧化铝生产设备中的除尘设备主要包括三类，下列不属于这三类的除尘设备是（ ）。",[589,591,593,595],{"key":20,"text":590,"correct":26},"旋风除尘器",{"key":24,"text":592,"correct":26},"静电除尘器",{"key":28,"text":594,"correct":26},"布袋除尘器",{"key":31,"text":596,"correct":22},"活性炭除尘器",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":20,"analysis":33},997447,"熟料烧结工序存在的危险有害因素有火灾、爆炸、机械伤害、高处坠落、粉尘、噪声等。在煤粉制备过程的防火防爆措施中，说法正确的是（ ）。",[601,603,605,607],{"key":20,"text":602,"correct":22},"运行中及时消除磨煤机入口积煤、积粉现象，严格控制磨煤机出口温度",{"key":24,"text":604,"correct":26},"外漏煤粉发生自燃应使用柱状压力水灭火",{"key":28,"text":606,"correct":26},"停止制粉系统时，可先停止磨煤机，并持续保持通风",{"key":31,"text":608,"correct":26},"在处理分仓下粉不畅，敲击粉仓时，宜使用铁质工具",{"id":610,"libraryId":5,"type":15,"typeLabel":16,"stem":611,"options":612,"answer":20,"analysis":33},997448,"下列不属于预焙阳极电解槽四大部分的是（ ）。",[613,615,617,619],{"key":20,"text":614,"correct":22},"阳极结构",{"key":24,"text":616,"correct":26},"上部结构",{"key":28,"text":618,"correct":26},"母线结构",{"key":31,"text":620,"correct":26},"电气绝缘",[622,625,628,631,634,637],{"id":15,"name":623,"category":7,"favorite":624},"领导干部任职前廉政法规知识测试题",92,{"id":626,"name":627,"category":7,"favorite":15},595,"建筑结构与设备",{"id":629,"name":630,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":632,"name":633,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":635,"name":636,"category":7,"favorite":8},534,"BIM工程师",{"id":638,"name":636,"category":7,"favorite":8},535]