[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-729-15":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":610},{"id":5,"name":6,"category":7,"favorite":8},729,"安全生产技术基础","建筑工程",0,15,50,1831,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,237,248,260,269,280,292,304,316,328,340,349,361,373,385,397,409,421,430,442,454,466,478,490,502,514,526,538,550,562,574,586,598],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},995543,1,"单选题","不导电环境是指地板和墙都用不导电材料制成，即大大提高了绝缘水平的环境，下列不符合安全要求的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","电压500V及以上者，地板和墙每一点的电阻不应低于50kΩ",false,{"key":24,"text":25,"correct":26},"B","电压500V以上者不应低于80kΩ",true,{"key":28,"text":29,"correct":22},"C","具有永久性特征",{"key":31,"text":32,"correct":22},"D","场所内不得有保护零线或保护地线","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},995544,"爆炸性气体、蒸气按（ ）分为IIA级、IIB级、IIC级。",[38,40,42,44],{"key":20,"text":39,"correct":22},"引燃温度",{"key":24,"text":41,"correct":22},"爆炸极限",{"key":28,"text":43,"correct":26},"最小点燃电流比（MICR)和最大试验安全间隙（MESG)",{"key":31,"text":45,"correct":22},"闪点",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},995545,"对爆炸性粉尘环境，若在正常运行中，可燃性粉尘连续出现或经常出现其数量足以形成可燃性粉尘与空气混合物或形成无法控制和极厚的粉尘层的场所及容器内部，此类爆炸性环境应确定为（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"1区",{"key":24,"text":53,"correct":22},"2区",{"key":28,"text":55,"correct":26},"20区",{"key":31,"text":57,"correct":22},"21区",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},995546,"在结构上采取措施，提高安全程度，避免在正常或规定的过载条件下出现电弧、火花或可能点燃爆炸性混合物的髙温的电气设备称为（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"隔爆型防爆电气设备",{"key":24,"text":65,"correct":26},"增安型防爆电气设备",{"key":28,"text":67,"correct":22},"本质安全型防爆电气设备",{"key":31,"text":69,"correct":22},"充砂型防爆电气设备",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},995547,"下列防爆电气设备型式和标志中，表示隔爆型电气设备的防爆标志的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"i",{"key":24,"text":77,"correct":26},"d",{"key":28,"text":79,"correct":22},"e",{"key":31,"text":81,"correct":22},"p",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},995548,"防爆电器应有具体的标志，并且应设置在设备外部主体部分的明显地方。设备为正压型，保护等级为Db，用于DB类T3组爆炸性气体环境的防爆电器，下列编号正确的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"ExdIIBT3Db",{"key":24,"text":89,"correct":26},"ExpIIBT3Db",{"key":28,"text":91,"correct":22},"ExoT3DbIIB",{"key":31,"text":93,"correct":22},"ExdT3DbIIB",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},995549,"在爆炸危险环境，低压电力、照明线路所用电线和电缆的额定电压不得低于工作电压，并不得低于（ ）V。",[98,100,102,104],{"key":20,"text":99,"correct":22},"220",{"key":24,"text":101,"correct":22},"380",{"key":28,"text":103,"correct":26},"500",{"key":31,"text":105,"correct":22},"750",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":28,"analysis":33},995550,"下列关于电气灭火的说法错误的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"发现起火后，首先要设法切断电源",{"key":24,"text":113,"correct":22},"拉闸时最好用绝缘工具操作",{"key":28,"text":115,"correct":26},"泡沫灭火器可用于带电灭火",{"key":31,"text":117,"correct":22},"对架空线路等空中设备进行灭火时，人体位置与带电体之间的仰角不应超过45°",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},995551,"雷电放电时形成的发红光、橙光、白光或其他颜色光的火球，出现的概率约为雷电放电次数的2%，这是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"雷云",{"key":24,"text":125,"correct":26},"雷球",{"key":28,"text":127,"correct":22},"感应雷",{"key":31,"text":129,"correct":22},"直击雷",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":31,"analysis":33},995552,"防雷装置的引下线应满足力学强度、耐腐蚀和热稳定的要求，引下线截面（ ）应予以更换。",[134,136,138,140],{"key":20,"text":135,"correct":22},"出现锈蚀",{"key":24,"text":137,"correct":22},"锈蚀10%以上者",{"key":28,"text":139,"correct":22},"锈蚀20%以上者",{"key":31,"text":141,"correct":26},"锈蚀30%以上者",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},995553,"下列不符合变、配电占安全要求的是（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"从供电角度考虑，变、配电站应接近负荷中心",{"key":24,"text":149,"correct":26},"高压配电室和高压电容器室耐火等级不应低于三级",{"key":28,"text":151,"correct":22},"变、配电站各间隔的门应向外开启",{"key":31,"text":153,"correct":22},"蓄电池室应隔离安装",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":31,"analysis":33},995554,"兆欧表中，用于消除表面电流影响测量准确性的专用端子是（ ）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"E端",{"key":24,"text":161,"correct":22},"L端",{"key":28,"text":163,"correct":22},"T端",{"key":31,"text":165,"correct":26},"G端",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":28,"analysis":33},995555,"可燃气体检测仪器安置时，下列说法错误的是（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"安装前检查探头是否完好，规格是否与安装条件相符，井校准",{"key":24,"text":173,"correct":22},"探头应尽量避开高温、潮湿、多尘等有害环境",{"key":28,"text":175,"correct":26},"可燃气体比空气重时，探头应安装在设备上方",{"key":31,"text":177,"correct":22},"探头安装可采用吊装、壁装、抱管安装等安装方式，安装应牢固",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":28,"analysis":33},995556,"构成雷电的基本条件是（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":22},"建筑带电",{"key":24,"text":185,"correct":22},"大地带电",{"key":28,"text":187,"correct":26},"带电积云",{"key":31,"text":189,"correct":22},"强烈放电",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":31,"analysis":33},995557,"下列属于第一类防雷建筑物的是（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"国家级的会堂",{"key":24,"text":197,"correct":22},"国际特级和甲级大型体育馆",{"key":28,"text":199,"correct":22},"有爆炸危险的露天气罐和油罐",{"key":31,"text":201,"correct":26},"具有0区、20区爆炸危险场所的建筑物",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":28,"analysis":33},995558,"第三类防雷建筑物的滚球半径是（ ）m。",[206,208,210,212],{"key":20,"text":207,"correct":22},"30",{"key":24,"text":209,"correct":22},"45",{"key":28,"text":211,"correct":26},"60",{"key":31,"text":213,"correct":22},"75",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":28,"analysis":33},995559,"阀型避雷器的接地电阻一般不应大于（ ）Ω。",[218,220,222,224],{"key":20,"text":219,"correct":22},"3",{"key":24,"text":221,"correct":22},"4",{"key":28,"text":223,"correct":26},"5",{"key":31,"text":225,"correct":22},"10",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":24,"analysis":33},995560,"某10KV架空线路导线经过交通困难地区时，与地面和水面的最小距离是（ ）m。",[230,232,234,236],{"key":20,"text":231,"correct":22},"5.5",{"key":24,"text":233,"correct":26},"4.5",{"key":28,"text":235,"correct":22},"3.5",{"key":31,"text":219,"correct":22},{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":28,"analysis":33},995561,"防爆电器应有具体的标志，并且应设置在设备外部主体部分的明显地方。以ExdIIBT3Gb为例，下列解释正确的是（ ）。",[241,243,245,247],{"key":20,"text":242,"correct":22},"表示该设备为正压型&ldquo;d&rdquo;，保护级别为Gb，用于IIB类T3组爆炸性气体环境",{"key":24,"text":244,"correct":22},"表示该设备为正压型&ldquo;d&rdquo;，保护级别为II用于Gb类T3组爆炸性气体环境",{"key":28,"text":246,"correct":26},"表示该设备为隔爆型&ldquo;d&rdquo;，保护级别为Gb，用于DB类T3组爆炸性气体环境",{"key":31,"text":244,"correct":22},{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":28,"analysis":33},995562,"架空电力线路严禁跨越爆炸性气体环境，架空线路与爆炸性气体环境的水平距离，（ ）。",[252,254,256,258],{"key":20,"text":253,"correct":22},"不应小于15m",{"key":24,"text":255,"correct":22},"不应小于5m",{"key":28,"text":257,"correct":26},"不应小于杆塔高度的1.5倍",{"key":31,"text":259,"correct":22},"不应小于杆塔高度的5倍",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":31,"analysis":33},995563,"某1KV架空线路导线经过居民区时，与地面和水面的最小距离是（ ）m。",[264,265,266,267],{"key":20,"text":219,"correct":22},{"key":24,"text":221,"correct":22},{"key":28,"text":223,"correct":22},{"key":31,"text":268,"correct":26},"6",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":31,"analysis":33},995564,"部分省市统计资料表明，农村触电事故约为城市的（ ）倍。主要原因是农村设备条件较差、技术水平较低和安全知识不足。",[273,275,277,279],{"key":20,"text":274,"correct":22},"1.5",{"key":24,"text":276,"correct":22},"2",{"key":28,"text":278,"correct":22},"2.5",{"key":31,"text":219,"correct":26},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":20,"analysis":33},995565,"下列关于绝缘击穿的说法，正确的是（ ）。",[284,286,288,290],{"key":20,"text":285,"correct":26},"气体绝缘击穿后绝缘性能会很快恢复",{"key":24,"text":287,"correct":22},"液体绝缘的击穿特性与其纯净度无关",{"key":28,"text":289,"correct":22},"固体绝缘的电击穿时间较长、击穿电压较低",{"key":31,"text":291,"correct":22},"固体绝缘的热击穿时间较短、击穿电压较高",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":31,"analysis":33},995566,"摆脱概率为50%的摆脱电流，成年男子约为（ ）。",[296,298,300,302],{"key":20,"text":297,"correct":22},"6mA",{"key":24,"text":299,"correct":22},"9mA",{"key":28,"text":301,"correct":22},"10.5mA",{"key":31,"text":303,"correct":26},"16mA",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":24,"analysis":33},995567,"当绝缘体受潮或受到过高的温度、过高的电压时，可能完全失去绝缘能力而导电，称为绝缘击穿或绝缘破坏。下列关于绝缘击穿的说法中，正确的是（）。",[308,310,312,314],{"key":20,"text":309,"correct":22},"气体击穿是碰撞电离导致的电击穿，击穿后绝缘性能不可恢复",{"key":24,"text":311,"correct":26},"液体绝缘的击穿特性与其纯净度有关，纯净液体击穿也是电击穿，密度越大越难击穿",{"key":28,"text":313,"correct":22},"液体绝缘击穿后，绝缘性能能够很快完全恢复",{"key":31,"text":315,"correct":22},"固体绝缘击穿后只能在一定程度上恢复其绝缘性能",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":24,"analysis":33},995568,"雷击有电性质、热性质、机械性质等多方面的破坏作用，并产生严重后果，对人的生命、财产构成很大的威胁下列各种危险危害中不属于雷击危险危害的是（）。",[320,322,324,326],{"key":20,"text":321,"correct":22},"二次放电引起的触电事故",{"key":24,"text":323,"correct":26},"导致变压器断路",{"key":28,"text":325,"correct":22},"引起火灾和爆炸",{"key":31,"text":327,"correct":22},"使人遭受致命电击",{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":31,"analysis":33},995569,"按照发生电击时电气设备的状态，电击分为直接接触电击和间接接触电击。下列触电导致人遭到电击的状态中，属于直接接触电击的是（ ）。",[332,334,336,338],{"key":20,"text":333,"correct":22},"带金属防护网外壳的排风机漏电，工作人员触碰到排风机防护网而遭到电击",{"key":24,"text":335,"correct":22},"电动机线路短路漏电，工作人员触碰电动机时触电",{"key":28,"text":337,"correct":22},"泳池漏电保护器损坏，游客游泳过程中遭到电击",{"key":31,"text":339,"correct":26},"工作人员在起重臂上操作，起重机吊臂碰到380V架空线，挂钩工人遭到电击",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":31,"analysis":33},995570,"电击分为直接接触电击和间接接触电击。下列触电导致人遭到电击的状态中，属于直接接触电击的是（）。",[344,345,346,347],{"key":20,"text":333,"correct":22},{"key":24,"text":335,"correct":22},{"key":28,"text":337,"correct":22},{"key":31,"text":348,"correct":26},"工作人员在起重臂上操作，起重机吊臂碰到380V架空线，挂钩工人遭到电击。",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":24,"analysis":33},995571,"数十至数百毫安的小电流通过人体短时间使人致命的最危险的原因是（ ）。",[353,355,357,359],{"key":20,"text":354,"correct":22},"呼吸困难",{"key":24,"text":356,"correct":26},"引起心室纤维性颤动",{"key":28,"text":358,"correct":22},"心律不齐",{"key":31,"text":360,"correct":22},"痉挛",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":24,"analysis":33},995572,"下图所示是某工地一起特大触电事故的描述图片。20余名工人抬着睐望塔经过10kV架空线下方时发生强烈放电，导致多人触电死亡。按照触电事故的类型，该起触电事故属于（）。",[365,367,369,371],{"key":20,"text":366,"correct":22},"低压直接接触电击",{"key":24,"text":368,"correct":26},"高压直接接触电击",{"key":28,"text":370,"correct":22},"高压间接接触电击",{"key":31,"text":372,"correct":22},"低压间接接触电击",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":20,"analysis":33},995573,"雷电是大气中的一种放电现象，具有雷电流幅值大、雷电流陡度大、冲击性强、冲击过电压高等特点。下列关于雷电破坏作用的说法中，正确的是（）。",[377,379,381,383],{"key":20,"text":378,"correct":26},"破坏电力设备的绝缘",{"key":24,"text":380,"correct":22},"引起电气设备过负荷",{"key":28,"text":382,"correct":22},"造成电力系统过负荷",{"key":31,"text":384,"correct":22},"引起电动机转速异常",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":24,"analysis":33},995574,"通风条件和释放源的等级综合决定了环境的爆炸危险性。同时，释放源也是划分爆炸危险区域的基础。下列关于爆炸危险区域的划分和释放源的说法中，正确的是（ ）。",[389,391,393,395],{"key":20,"text":390,"correct":22},"一级释放源是连续、长时间释放或短时间频繁释放的释放源",{"key":24,"text":392,"correct":26},"包含连续级释放源的区域可划分为0区",{"key":28,"text":394,"correct":22},"二级释放源是正常运行时周期性释放或偶然释放的释放源",{"key":31,"text":396,"correct":22},"包含一级释放源的区域可划分为0区",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":24,"analysis":33},995575,"下列关于人体电阻说法错误的是（ ）。",[401,403,405,407],{"key":20,"text":402,"correct":22},"人体电阻是由皮肤、血液、肌肉、细胞组织及其结合部所组成的",{"key":24,"text":404,"correct":26},"人体电阻是含有阻抗和电容的电阻",{"key":28,"text":406,"correct":22},"人体电容只有数百皮法",{"key":31,"text":408,"correct":22},"表皮电阻高，但容易受到机械破坏和电击穿",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":24,"analysis":33},995576,"接闪器的保护范围按照滚球法确定滚球的半径按建筑物防雷类别确定，一类建筑物的滚球半径为（）。",[413,415,417,419],{"key":20,"text":414,"correct":22},"15m",{"key":24,"text":416,"correct":26},"30m",{"key":28,"text":418,"correct":22},"45m",{"key":31,"text":420,"correct":22},"60m",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":28,"analysis":33},995577,"在户外避雨时，要注意离开墙壁或树干（ ）m以外。",[425,426,427,429],{"key":20,"text":219,"correct":22},{"key":24,"text":223,"correct":22},{"key":28,"text":428,"correct":26},"8",{"key":31,"text":225,"correct":22},{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":31,"analysis":33},995578,"对于固体，电阻率（ ）时，容易积累静电。",[434,436,438,440],{"key":20,"text":435,"correct":22},"小于1×10 7 Ω.m",{"key":24,"text":437,"correct":22},"大于1×10 7 Ω.m",{"key":28,"text":439,"correct":22},"小于1×10 9 Ω.m",{"key":31,"text":441,"correct":26},"大于1×10 9 Ω.m",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":20,"analysis":33},995579,"静电放电有多种形式，其中（ ）放电是发生在带电体尖端附近局部区域内的放电。",[446,448,450,452],{"key":20,"text":447,"correct":26},"电晕",{"key":24,"text":449,"correct":22},"刷形",{"key":28,"text":451,"correct":22},"火花",{"key":31,"text":453,"correct":22},"云形",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":24,"analysis":33},995580,"第二种防护中防护等级5，对应的防护性能（ ）。",[458,460,462,464],{"key":20,"text":459,"correct":22},"垂直的滴水不能直接进入产品内部",{"key":24,"text":461,"correct":26},"任何方向的喷水对产品应无有害的影响",{"key":28,"text":463,"correct":22},"与垂线成60度角范围内的淋水不能直接进入产品内部",{"key":31,"text":465,"correct":22},"产品在规定的压力和时间下浸在水中，进水量应元有害影响",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":28,"analysis":33},995581,"下列关于手持电动工具和移动式电气设备的安全使用说法错误的是（ ）。",[470,472,474,476],{"key":20,"text":471,"correct":22},"皿类设备没有保护接地或保护接零的要求",{"key":24,"text":473,"correct":22},"I类设备必须采取保护接地或保护接零措施",{"key":28,"text":475,"correct":26},"一般场所，手持电动工具应采用I类设备",{"key":31,"text":477,"correct":22},"操作时使用绝缘于套、绝缘鞋、绝缘垫等安全用具也是一种防止触电的安全措施",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":24,"analysis":33},995582,"下列关于热继电器说法错误的是（ ）。",[482,484,486,488],{"key":20,"text":483,"correct":22},"热继电器的核心元件是热元件",{"key":24,"text":485,"correct":26},"动作延时小",{"key":28,"text":487,"correct":22},"热容量较大",{"key":31,"text":489,"correct":22},"不能用于短路保护",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":31,"analysis":33},995583,"为了避免注意力不集中造成事故，应当采用必要的（ ）装置。",[494,496,498,500],{"key":20,"text":495,"correct":22},"屏护",{"key":24,"text":497,"correct":22},"隔离",{"key":28,"text":499,"correct":22},"防护",{"key":31,"text":501,"correct":26},"联锁",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":24,"analysis":33},995584,"SF 6 断路器的灭弧方法是（ ）。",[506,508,510,512],{"key":20,"text":507,"correct":22},"真空灭弧",{"key":24,"text":509,"correct":26},"气吹灭弧",{"key":28,"text":511,"correct":22},"拉长灭弧",{"key":31,"text":513,"correct":22},"油气纵横吹灭弧",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":31,"analysis":33},995585,"高压开关中，（ ）正确的操作顺序是拉闸时先拉开中相，再拉开下风侧边相，最后拉开上风侧边相。",[518,520,522,524],{"key":20,"text":519,"correct":22},"户内型隔离开关",{"key":24,"text":521,"correct":22},"户外型隔离开关",{"key":28,"text":523,"correct":22},"断路器",{"key":31,"text":525,"correct":26},"跌开式熔断器",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":31,"analysis":33},995586,"对于电缆10kV以下的中间接头多采用（ ）。",[530,532,534,536],{"key":20,"text":531,"correct":22},"铸铁外壳",{"key":24,"text":533,"correct":22},"瓷外壳",{"key":28,"text":535,"correct":22},"尼龙",{"key":31,"text":537,"correct":26},"环氧树脂",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":24,"analysis":33},995587,"谐波是频率为（ ）。",[542,544,546,548],{"key":20,"text":543,"correct":22},"50Hz的正弦波",{"key":24,"text":545,"correct":26},"50Hz整数倍的正弦波",{"key":28,"text":547,"correct":22},"50Hz的非正弦波",{"key":31,"text":549,"correct":22},"50Hz整数倍的非正弦波",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":28,"analysis":33},995588,"在电击的分类中，()是不接地状态的人体某两个部位同时触及不同电位的两个导体时由接触电压造成的电击。",[554,556,558,560],{"key":20,"text":555,"correct":22},"直接接触电击",{"key":24,"text":557,"correct":22},"间接接触电击",{"key":28,"text":559,"correct":26},"两线电击",{"key":31,"text":561,"correct":22},"跨步电压电击",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":31,"analysis":33},995589,"下图表示人的室颤电流与电流持续时间的关系。该图表明，当电流持续时间超过心脏搏动周期时，人的室颤电流约为()。",[566,568,570,572],{"key":20,"text":567,"correct":22},"550mA",{"key":24,"text":569,"correct":22},"500mA",{"key":28,"text":571,"correct":22},"450mA",{"key":31,"text":573,"correct":26},"50mA",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":28,"analysis":33},995590,"电击分为直接接触电击和间接接触电击。下列触电导致人遭到电击的状态中，属于直接接触电击的是()。",[578,580,582,584],{"key":20,"text":579,"correct":22},"电风扇漏电，有人碰到电风扇金属罩而遭到电击",{"key":24,"text":581,"correct":22},"有人把照明灯电线缠在铁丝上，电线绝缘层磨破，碰到铁丝而遭到电击",{"key":28,"text":583,"correct":26},"起重机吊臂碰到380V架空线，挂钩工人遭到电击",{"key":31,"text":585,"correct":22},"架空线电线折断，电线落在金属货架上。人碰到金属货架而遭到电击",{"id":587,"libraryId":5,"type":15,"typeLabel":16,"stem":588,"options":589,"answer":31,"analysis":33},995591,"数十至数百毫安的小电流通过人体短时间使人致命的最危险的原因是引起()。",[590,592,594,596],{"key":20,"text":591,"correct":22},"昏迷",{"key":24,"text":593,"correct":22},"严重麻痹",{"key":28,"text":595,"correct":22},"剧烈疼痛",{"key":31,"text":597,"correct":26},"心室纤维性颤动",{"id":599,"libraryId":5,"type":15,"typeLabel":16,"stem":600,"options":601,"answer":20,"analysis":33},995592,"屏护和间距是最为常用的电气安全措施之一，按照防止触电的形式分类，屏护和间距应属于( )。",[602,604,606,608],{"key":20,"text":603,"correct":26},"防止直接接触电击安全措施",{"key":24,"text":605,"correct":22},"兼防直接接触电击和间接接触电击的安全措施",{"key":28,"text":607,"correct":22},"间接接触电击安全措施",{"key":31,"text":609,"correct":22},"其他安全措施",[611,614,617,620,623,626],{"id":15,"name":612,"category":7,"favorite":613},"领导干部任职前廉政法规知识测试题",92,{"id":615,"name":616,"category":7,"favorite":15},595,"建筑结构与设备",{"id":618,"name":619,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":621,"name":622,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":624,"name":625,"category":7,"favorite":8},534,"BIM工程师",{"id":627,"name":625,"category":7,"favorite":8},535]