[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-729-14":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":597},{"id":5,"name":6,"category":7,"favorite":8},729,"安全生产技术基础","建筑工程",0,14,50,1831,[13,34,46,58,70,82,94,104,116,128,140,152,162,174,186,197,209,219,228,240,252,264,276,288,300,312,323,335,347,359,369,378,389,401,413,425,437,449,461,473,484,493,505,517,528,539,551,563,575,585],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},995493,1,"单选题","根据GB\u002FT13870.1《电流对人和家畜的效应第1部分：通用部分》的规定，总结出了电流对人体作用带域划分图（下图），对于AC-1所在的a区域的说法中，正确的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","a区域为AC-1所在的区域，该区域电流较小，通过人体几乎无生理效应",true,{"key":24,"text":25,"correct":26},"B","a区域为AC-1所在的区域，该区域电流较小，通过人体能产生感觉但基本没有损害",false,{"key":28,"text":29,"correct":26},"C","a区域为AC-1所在的区域，该区域电流较小，通过人体可能导致肌肉收缩但不致命",{"key":31,"text":32,"correct":26},"D","a区域为AC-1所在的区域，该区域电流较大，通过人体可能造成室颤并导致死亡","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},995494,"触电事故是由电流形态的能量造成的事故，在触电事故中（ ）%以上的死亡事故是电击造成的。",[38,40,42,44],{"key":20,"text":39,"correct":26},"70",{"key":24,"text":41,"correct":26},"75",{"key":28,"text":43,"correct":26},"80",{"key":31,"text":45,"correct":22},"85",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},995495,"对于有爆炸性危险的环境要使用与其危险相对应的防爆电气设备。下列关于防爆电气设备分类的说法中，错误的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"Ⅰ类电气设备适用于煤矿瓦斯气体环境，Ⅱ类电气设备用于煤矿甲烷以外的爆炸性气体环境",{"key":24,"text":53,"correct":26},"Ⅲ类电气设备用于爆炸性粉尘环境",{"key":28,"text":55,"correct":22},"对于Ⅱ类电气设备分级中，保护等级的排序为Ga＜Gb＜Gc",{"key":31,"text":57,"correct":26},"对于Ⅲ类电气设备分级中，保护等级的排序为Da＞Db＞Dc",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},995496,"有一种防雷装置，当雷电冲击波到来时，该装置被击穿，将雷电波引人大地，而在雷电冲击波过去后，该装置自动恢复绝缘状态，这种装置是（）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"接闪器",{"key":24,"text":65,"correct":26},"接地装置",{"key":28,"text":67,"correct":26},"避雷针",{"key":31,"text":69,"correct":22},"避雷器",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},995497,"人们接触最多的频率是（ ）Hz，对于电击来说也是最危险的频率。",[74,76,78,80],{"key":20,"text":75,"correct":26},"30",{"key":24,"text":77,"correct":26},"40",{"key":28,"text":79,"correct":22},"50",{"key":31,"text":81,"correct":26},"60",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},995498,"直流电流感知阈值约为（ ）mA。",[86,88,90,92],{"key":20,"text":87,"correct":22},"2",{"key":24,"text":89,"correct":26},"5",{"key":28,"text":91,"correct":26},"10",{"key":31,"text":93,"correct":26},"无确定值",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},995499,"用于防直击雷的防雷装置中，（）是利用其高出被保护物的地位，把雷电引向自身，起到拦截闪击的作用。",[98,99,101,102],{"key":20,"text":63,"correct":22},{"key":24,"text":100,"correct":26},"引下线",{"key":28,"text":65,"correct":26},{"key":31,"text":103,"correct":26},"屏蔽导体",{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":24,"analysis":33},995500,"采用不同的接地、接零保护方式的配电系统，如IT系统（保护接地）、TT系统和TN系统（保护接零），属于间接接触电击防护措施，下列关于上述三种系统的说法中，不正确的是（ ）。",[108,110,112,114],{"key":20,"text":109,"correct":26},"TT系统串联有R N 、R E ，同在一个数量级，漏电设备对地电压不能降低到安全范围以内",{"key":24,"text":111,"correct":22},"TT系统必须安装电流保护装置，并且优先选择过电流保护器",{"key":28,"text":113,"correct":26},"IT系统由于单相接地电流较小，才有可能通过保护接地把漏电设备故障电压限制在安全范围内",{"key":31,"text":115,"correct":26},"IT系统能够将故障电压限制在安全范围内，但漏电状态并未消失",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":20,"analysis":33},995501,"生产工艺过程中所产生静电的最大危险是引起爆炸。因此，在爆炸危险环境必须采取严密的防静电措施。下列各项措施中，不属于防静电措施的有（）。",[120,122,124,126],{"key":20,"text":121,"correct":22},"安装短路保护和过载保护装置",{"key":24,"text":123,"correct":26},"将作业现场所有不带电的金属连成整体并接地",{"key":28,"text":125,"correct":26},"限制流速",{"key":31,"text":127,"correct":26},"增加作业环境的相对湿度",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":28,"analysis":33},995502,"下列事故中，不属于电气事故的是（ ）。",[132,134,136,138],{"key":20,"text":133,"correct":26},"雷电和静电事故",{"key":24,"text":135,"correct":26},"电磁辐射事故",{"key":28,"text":137,"correct":22},"电焊操作引燃事故",{"key":31,"text":139,"correct":26},"触电事故",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":20,"analysis":33},995503,"下列电工绝缘材料中，不属于固体绝缘材料的有（ ）。",[144,146,148,150],{"key":20,"text":145,"correct":22},"硅油",{"key":24,"text":147,"correct":26},"石棉",{"key":28,"text":149,"correct":26},"橡胶",{"key":31,"text":151,"correct":26},"塑料",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":31,"analysis":33},995504,"在接零系统中，对于配电线路或仅供给固定式电气设备的线路，故障持续时间不宜超过（ ）s。",[156,158,160,161],{"key":20,"text":157,"correct":26},"0.2",{"key":24,"text":159,"correct":26},"0.4",{"key":28,"text":87,"correct":26},{"key":31,"text":89,"correct":22},{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":28,"analysis":33},995505,"工作接地的主要作用是减轻各种过电压的危险，一般可限制中性线对地电压一般不超过（ ）。",[166,168,170,172],{"key":20,"text":167,"correct":26},"10V",{"key":24,"text":169,"correct":26},"36V",{"key":28,"text":171,"correct":22},"50V",{"key":31,"text":173,"correct":26},"110V",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":24,"analysis":33},995506,"II类设备的绝缘电阻用（ ）测试。",[178,180,182,184],{"key":20,"text":179,"correct":26},"500V交流电压",{"key":24,"text":181,"correct":22},"500V直流电压",{"key":28,"text":183,"correct":26},"1000V交流电压",{"key":31,"text":185,"correct":26},"1000V直流电压",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":28,"analysis":33},995507,"电铃用变压器的额定容量不应超过（ ）V·A。",[190,191,193,195],{"key":20,"text":91,"correct":26},{"key":24,"text":192,"correct":26},"16",{"key":28,"text":194,"correct":22},"100",{"key":31,"text":196,"correct":26},"200",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":24,"analysis":33},995508,"下列关于电磁式漏电保护装置说法错误的是（ ）。",[201,203,205,207],{"key":20,"text":202,"correct":26},"结构简单",{"key":24,"text":204,"correct":22},"工艺难度小",{"key":28,"text":206,"correct":26},"灵敏度不高",{"key":31,"text":208,"correct":26},"承受过电流或过电压冲击的能力较强",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":24,"analysis":33},995509,"延时型只能用于动作电流30mA以上的漏电保护装置，其动作时间不可选（ ）s。",[213,214,216,218],{"key":20,"text":157,"correct":26},{"key":24,"text":215,"correct":22},"0.5",{"key":28,"text":217,"correct":26},"0.8",{"key":31,"text":87,"correct":26},{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":24,"analysis":33},995510,"电气火灾约占全部火灾总数的（ ）%。",[223,225,226,227],{"key":20,"text":224,"correct":26},"20",{"key":24,"text":75,"correct":22},{"key":28,"text":77,"correct":26},{"key":31,"text":79,"correct":26},{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":24,"analysis":33},995511,"剩余电流动作保护又称为漏电保护，是利用剩余电流动作保护装置来防止电气事故的一种安全技术措施。其装置和工作原理图如下图所示，下列关于剩余电流动作保护的工作原理，说法正确是（）。",[232,234,236,238],{"key":20,"text":233,"correct":26},"M电动机漏电，人触碰后形成短路，促使中间环节 TL动作，发出信号导致熔断器熔断以切断供电电源",{"key":24,"text":235,"correct":22},"TA表示零序电流互感器，由TA获取漏电信号经中间环节放大电信号，使QF跳闸",{"key":28,"text":237,"correct":26},"M电动机外壳发生漏电，能够通过电气设备上的保护接触线把剩余电流引人大地",{"key":31,"text":239,"correct":26},"剩余电流直接促使电气线路上的保护元件迅速动作断开供电电源",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":31,"analysis":33},995512,"下列属于电火花中工作火花的是（ ）。",[244,246,248,250],{"key":20,"text":245,"correct":26},"电路发生短路的火花",{"key":24,"text":247,"correct":26},"线路断开时产生的火花",{"key":28,"text":249,"correct":26},"熔丝熔断时产生的火花",{"key":31,"text":251,"correct":22},"接触器接通和断开线路时产生的火花",{"id":253,"libraryId":5,"type":15,"typeLabel":16,"stem":254,"options":255,"answer":24,"analysis":33},995513,"下列雷电参数说法中错误的是（ ）。",[256,258,260,262],{"key":20,"text":257,"correct":26},"一天之内能听到雷声的就算一个雷暴日",{"key":24,"text":259,"correct":22},"雷电流幅值指主放电时冲击电流的平均值",{"key":28,"text":261,"correct":26},"雷电流陡度指雷电流随时间上升的速度",{"key":31,"text":263,"correct":26},"直击雷冲击过电压高达数千千伏",{"id":265,"libraryId":5,"type":15,"typeLabel":16,"stem":266,"options":267,"answer":28,"analysis":33},995514,"在任何情况下，第一类防雷建筑物防止二次放电的最小距离不得小于（ ）m，第二类防雷建筑物防止二次放电的最小距离不得小于（ ）m。",[268,270,272,274],{"key":20,"text":269,"correct":26},"4、3",{"key":24,"text":271,"correct":26},"4、2",{"key":28,"text":273,"correct":22},"3、2",{"key":31,"text":275,"correct":26},"3、1",{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":31,"analysis":33},995515,"静电产生的方式也很多，最常见的方式是（ ）起电。",[280,282,284,286],{"key":20,"text":281,"correct":26},"感应",{"key":24,"text":283,"correct":26},"破断",{"key":28,"text":285,"correct":26},"摩擦",{"key":31,"text":287,"correct":22},"接触－分离",{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":28,"analysis":33},995516,"静电放电有多种形式，下图中是（ ）放电。",[292,294,296,298],{"key":20,"text":293,"correct":26},"电晕",{"key":24,"text":295,"correct":26},"云形",{"key":28,"text":297,"correct":22},"火花",{"key":31,"text":299,"correct":26},"刷形",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":24,"analysis":33},995517,"下列关于静电防护措施中接地的说法错误的是（ ）。",[304,306,308,310],{"key":20,"text":305,"correct":26},"接地的主要作用是消除导体上的静电",{"key":24,"text":307,"correct":22},"金属导体不应直接接地",{"key":28,"text":309,"correct":26},"防静电接地电阻原则上不超过1MΩ即可",{"key":31,"text":311,"correct":26},"感应静电接地只能消除部分危险",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":28,"analysis":33},995518,"电机和低压电器的外壳防护包括两种防护，第一种防护分为（ ）级。",[316,318,319,321],{"key":20,"text":317,"correct":26},"3",{"key":24,"text":89,"correct":26},{"key":28,"text":320,"correct":22},"7",{"key":31,"text":322,"correct":26},"9",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":31,"analysis":33},995519,"电动机安全运行条件中，下列说法错误的是（ ）。",[327,329,331,333],{"key":20,"text":328,"correct":26},"电压不平衡不得超过5%",{"key":24,"text":330,"correct":26},"电流不平衡不得超过10%",{"key":28,"text":332,"correct":26},"用热继电器保护时，热元件的电流不应大于电动机额定电流的1～1.5倍",{"key":31,"text":334,"correct":22},"不定期维修，有维修记录",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":31,"analysis":33},995520,"下图的低压电器有灭弧装置，能频繁操作，该低压电器是（ ）。",[339,341,343,345],{"key":20,"text":340,"correct":26},"铁壳开关",{"key":24,"text":342,"correct":26},"万能型低压断路器",{"key":28,"text":344,"correct":26},"微型断路器",{"key":31,"text":346,"correct":22},"接触器",{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":28,"analysis":33},995521,"低压配电箱落地安装的箱柜底面应高出底面50～100mm，操作手柄中心高度一般为（ ）m。",[351,353,355,357],{"key":20,"text":352,"correct":26},"0.8～1.0",{"key":24,"text":354,"correct":26},"1.0～1.2",{"key":28,"text":356,"correct":22},"1.2～1.5",{"key":31,"text":358,"correct":26},"1.5～2.0",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":31,"analysis":33},995522,"屋外单台电气设备的油量在（ ）kg以上时，应设置贮油或挡油设施。",[363,364,365,367],{"key":20,"text":194,"correct":26},{"key":24,"text":196,"correct":26},{"key":28,"text":366,"correct":26},"500",{"key":31,"text":368,"correct":22},"1000",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":20,"analysis":33},995523,"电力线路中，橡皮绝缘线最高运行温度为（ ）℃。",[373,375,376,377],{"key":20,"text":374,"correct":22},"65",{"key":24,"text":39,"correct":26},{"key":28,"text":41,"correct":26},{"key":31,"text":43,"correct":26},{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":28,"analysis":33},995524,"接地电阻测量仪测量时，接于电流极的是（ ）。",[382,384,386,387],{"key":20,"text":383,"correct":26},"E",{"key":24,"text":385,"correct":26},"P",{"key":28,"text":28,"correct":22},{"key":31,"text":388,"correct":26},"G",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":20,"analysis":33},995525,"可燃气体检测浓度用（ ）表示。",[393,395,397,399],{"key":20,"text":394,"correct":22},"百万分比",{"key":24,"text":396,"correct":26},"十万分比",{"key":28,"text":398,"correct":26},"万分比",{"key":31,"text":400,"correct":26},"千分比",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":24,"analysis":33},995526,"人体发生带电事故，通常分为电击和电伤两种。下列关于电击和电伤的说法中，错误的是（ ）。",[405,407,409,411],{"key":20,"text":406,"correct":26},"按发生电击时电气设备的状态，电击可分为直接接触电击和间接接触电击",{"key":24,"text":408,"correct":22},"电烙印是因电能转换成的热能引起的伤害",{"key":28,"text":410,"correct":26},"单线电击是发生最多的触电事故",{"key":31,"text":412,"correct":26},"电弧烧伤是最危险的电伤",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":24,"analysis":33},995527,"下列关于室颤电流说法错误的是（ ）。",[417,419,421,423],{"key":20,"text":418,"correct":26},"电击持续时间越长，越容易引起心室纤维性颤动",{"key":24,"text":420,"correct":22},"电流持续时间越长，积累局外电能越多，室颤电流明显增大",{"key":28,"text":422,"correct":26},"心脏跳动周期中，只有相应于心脏收缩与舒张之交0.1～0.2s的T波对电流最敏感",{"key":31,"text":424,"correct":26},"电击持续时间延长，如接触电压不变，将导致通过人体的电流增大",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":20,"analysis":33},995528,"根据对触电事故的分析，从发生率上看，（ ），主要原因是安全教育不够、安全制度不严和安全措施不完善，一些人缺乏足够的安全意识。",[429,431,433,435],{"key":20,"text":430,"correct":22},"错误操作和违章作业造成的触电事故多",{"key":24,"text":432,"correct":26},"中、青年工人、非专业电工、合同工和临时工触电事故多",{"key":28,"text":434,"correct":26},"低压设备触电事故多",{"key":31,"text":436,"correct":26},"移动式设备和临时性设备触电事故多",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":20,"analysis":33},995529,"判断绝缘质量最基本、最简易的指标是（ ）。",[441,443,445,447],{"key":20,"text":442,"correct":22},"绝缘电阻",{"key":24,"text":444,"correct":26},"耐压强度",{"key":28,"text":446,"correct":26},"泄漏电流",{"key":31,"text":448,"correct":26},"介质损耗",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":28,"analysis":33},995530,"氧指数在（ ）%以上的为阻燃性材料。",[453,455,457,459],{"key":20,"text":454,"correct":26},"15",{"key":24,"text":456,"correct":26},"21",{"key":28,"text":458,"correct":22},"27",{"key":31,"text":460,"correct":26},"33",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":20,"analysis":33},995531,"（ ）系统可用于有爆炸危险，或火灾危险性较大，或安全要求较高的场所，宜用于有独立附设变电站的车间。",[465,467,469,471],{"key":20,"text":466,"correct":22},"TN-S",{"key":24,"text":468,"correct":26},"TN-C",{"key":28,"text":470,"correct":26},"TN-S-C",{"key":31,"text":472,"correct":26},"TN-C-S",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":31,"analysis":33},995532,"接地装置离建筑物墙基之间的地下水平距离不得小于（ ）m。",[477,479,480,482],{"key":20,"text":478,"correct":26},"0.6",{"key":24,"text":217,"correct":26},{"key":28,"text":481,"correct":26},"1.2",{"key":31,"text":483,"correct":22},"1.5",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":28,"analysis":33},995533,"潮湿环境中直流安全电压的限值取（ ）V。",[488,489,490,492],{"key":20,"text":192,"correct":26},{"key":24,"text":460,"correct":26},{"key":28,"text":491,"correct":22},"35",{"key":31,"text":79,"correct":26},{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":20,"analysis":33},995534,"隔离开关不具备操作负荷电流的能力，切断电路时，必须（ ）。",[497,499,501,503],{"key":20,"text":498,"correct":22},"先拉开断路器，后拉开隔离开关",{"key":24,"text":500,"correct":26},"先拉开隔离开关，后拉开断路器",{"key":28,"text":502,"correct":26},"先拉开中相，再拉开下风侧边相",{"key":31,"text":504,"correct":26},"先拉开下风侧边相，再拉开中相",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":24,"analysis":33},995535,"在高温场所，对于容易触及而又无防触电措施的固定式灯具，其安装高度不足2.2m时，应采用（ ）V电压。",[509,511,513,515],{"key":20,"text":510,"correct":26},"12",{"key":24,"text":512,"correct":22},"24",{"key":28,"text":514,"correct":26},"36",{"key":31,"text":516,"correct":26},"42",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":28,"analysis":33},995536,"照明配线应采用额定电压（ ）V的绝缘导线。",[521,523,525,526],{"key":20,"text":522,"correct":26},"220",{"key":24,"text":524,"correct":26},"380",{"key":28,"text":366,"correct":22},{"key":31,"text":527,"correct":26},"750",{"id":529,"libraryId":5,"type":15,"typeLabel":16,"stem":530,"options":531,"answer":28,"analysis":33},995537,"油浸式电力变压器的绝缘材料的最高工作温度不得超过（ ）℃。",[532,533,535,537],{"key":20,"text":45,"correct":26},{"key":24,"text":534,"correct":26},"95",{"key":28,"text":536,"correct":22},"105",{"key":31,"text":538,"correct":26},"120",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":28,"analysis":33},995538,"下列电气防火防爆技术说法错误的是（ ）。",[543,545,547,549],{"key":20,"text":544,"correct":26},"消除或减少爆炸性混合物",{"key":24,"text":546,"correct":26},"保持设备清洁有利于防火",{"key":28,"text":548,"correct":22},"油量600kg以下者，应安装在单独的防爆间隔内",{"key":31,"text":550,"correct":26},"采用TN-S系统，并装设双极开关同时操作相线和中性线",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":31,"analysis":33},995539,"下列不属于架空线路主要组成部分的是（ ）。",[555,557,559,561],{"key":20,"text":556,"correct":26},"导线",{"key":24,"text":558,"correct":26},"杆塔",{"key":28,"text":560,"correct":26},"绝缘子",{"key":31,"text":562,"correct":22},"终端接头",{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":24,"analysis":33},995540,"某事故现场如下图所示，电动机接地装置的接地电阻为3Ω；该电动机漏电，流过其接地装置电流为6A；地面十分潮湿。如果电阻1000Ω的人站在地面接触该电动机，1最有可能发生的情况是（ ）。",[567,569,571,573],{"key":20,"text":568,"correct":26},"引起该人发生心室纤维性颤动",{"key":24,"text":570,"correct":22},"使该人不能脱离带电体",{"key":28,"text":572,"correct":26},"使该人有电击感觉",{"key":31,"text":574,"correct":26},"使该人受到严重烧伤",{"id":576,"libraryId":5,"type":15,"typeLabel":16,"stem":577,"options":578,"answer":28,"analysis":33},995541,"由自然界正、负电荷形态的能量，在强烈放电时造成的事故是（ ）。",[579,580,582,584],{"key":20,"text":139,"correct":26},{"key":24,"text":581,"correct":26},"静电事故",{"key":28,"text":583,"correct":22},"雷电事故",{"key":31,"text":135,"correct":26},{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":28,"analysis":33},995542,"在380V不接地低压配电网中，为限制设备漏电时外壳对地电压不超过安全范围，一般要求保护接地电阻（ ）。",[589,591,593,595],{"key":20,"text":590,"correct":26},"不小于4Ω",{"key":24,"text":592,"correct":26},"不小于10Ω",{"key":28,"text":594,"correct":22},"不大于4Ω",{"key":31,"text":596,"correct":26},"不大于10Ω",[598,601,604,607,610,613],{"id":15,"name":599,"category":7,"favorite":600},"领导干部任职前廉政法规知识测试题",92,{"id":602,"name":603,"category":7,"favorite":15},595,"建筑结构与设备",{"id":605,"name":606,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":608,"name":609,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":611,"name":612,"category":7,"favorite":8},534,"BIM工程师",{"id":614,"name":612,"category":7,"favorite":8},535]