[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-729-13":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":609},{"id":5,"name":6,"category":7,"favorite":8},729,"安全生产技术基础","建筑工程",0,13,50,1831,[13,34,46,58,70,82,94,106,118,130,142,154,162,170,182,194,205,217,229,241,253,265,277,289,301,313,325,337,349,361,373,385,397,409,421,433,445,457,469,481,493,505,517,529,537,549,561,573,585,597],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},995441,1,"单选题","异质材料互相接触，由于材料的功函数不同，当两种材料之间的距离接近原子级别时，会在接触的两个表面上产生电荷，从而形成带电体的现象。这种现象叫作（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","感应起电",false,{"key":24,"text":25,"correct":26},"B","接触一分离起电",true,{"key":28,"text":29,"correct":22},"C","破断起电",{"key":31,"text":32,"correct":22},"D","电荷迁移","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},995442,"工艺过程中产生的静电可能引起爆炸、火灾、电击，还可能妨碍生产。关于静电防护的说法，错误的是（）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"用苛性锅、四氯化碳取代汽油等易燃介质作洗涤剂能够起到良好的防爆效果",{"key":24,"text":41,"correct":22},"汽车槽车、铁路槽车在装油之前，应与储油设备跨接并接地",{"key":28,"text":43,"correct":26},"接地的主要作用是消除绝缘体上的静电",{"key":31,"text":45,"correct":22},"静电消除器主要用于消除非导体上的静电",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},995443,"防止雷电伤害的方法包括设置防雷装置和人身防雷措施，下列关于人身防雷措施的说法中，错误的是（）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"雷暴时，在户外逗留时应尽量远离大树，可选择靠近池塘",{"key":24,"text":53,"correct":22},"如有条件可进入有宽大金属架构的建筑物、汽车或船只",{"key":28,"text":55,"correct":22},"在户外避雨时，要注意离开墙壁或树干8m以外",{"key":31,"text":57,"correct":22},"雷暴时，在户内也可能遭受雷电冲击波通过电气线路对人体的二次放电伤害",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},995444,"雷电是大气中的一种放电现象，具有电性质、热性质和机械性质三方面的破坏作用。下列雷电造成的破坏现象中，属于热性质破坏作业的是（）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"破坏高压输电系统，毁坏发电机、变压器、断路器等电气设备的绝缘",{"key":24,"text":65,"correct":22},"二次放电的火花引起火灾或爆炸",{"key":28,"text":67,"correct":22},"巨大的雷电流通过被击物时，在被击物缝隙中的气体剧烈膨胀，缝隙中的水分也急剧蒸发气化，致使被击物破坏或爆炸",{"key":31,"text":69,"correct":26},"巨大的雷电流通过导体烧毁导体使金属熔化、飞溅，引起火灾或爆炸",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},995445,"静电危害是由静电电荷或静电场能量引起的，静电电压可高达数十千伏.以上，容易产生静电火花。下列关于静电危害的说法中，正确的是（）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"静电能量极大，可能会直接导致人死亡",{"key":24,"text":77,"correct":26},"在某些生产过程中，静电的物理现象会妨碍生产，导致产品质量不良",{"key":28,"text":79,"correct":22},"静电剌激会使人产生恐惧心理但不会影响工作效率",{"key":31,"text":81,"correct":22},"静电会产生过量的辐射，可引起中枢神经系统的机能障碍",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},995446,"建筑物按其重要性、生产性质、遭受雷击的可能性和后果的严重性分成三类防雷建筑物。下列建筑物中，属于第二类防雷建筑物的是（）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"汽油提炼车间",{"key":24,"text":89,"correct":26},"国家特级和甲级大型体育馆",{"key":28,"text":91,"correct":22},"省级重点文物保护的建筑物",{"key":31,"text":93,"correct":22},"火药制造车间",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},995447,"为防止雷电对建筑物和雷电产生的过程电压随线路侵入对建筑物内电气设备绝缘造成的破坏，应该在建筑物和线路上安装防雷装置。下列关于安装防雷装置的说法中，错误的是（）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"阀型避雷器上端接驳在架空线路上，下端接地",{"key":24,"text":101,"correct":26},"第一类防雷建筑的防护直击雷的接闪杆可设置在建筑物上",{"key":28,"text":103,"correct":22},"第一类防雷建筑应采取防闪电感应的防护措施",{"key":31,"text":105,"correct":22},"第一类、第二类、第三类防雷建筑物均应采取闪电电流侵入的防护措施",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":28,"analysis":33},995448,"静电防护的主要措施包括静电接地、增湿、添加抗静电剂、使用静电中和器等几大类。下列关于静电防护措施的说法中，正确的是（）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"减少氧化剂含量，混合气体中含氧量不超过10%时即不会引起燃烧",{"key":24,"text":113,"correct":22},"油罐装油时，对于导电率低于50pS\u002Fm的液体石油产品，最大速度不应大于10m\u002Fs",{"key":28,"text":115,"correct":26},"工厂、车间的氧气等管道必须连成一个整体，应予以接地",{"key":31,"text":117,"correct":22},"在静电危险场所，穿脱衣物时应主要防止静电危害，并避免剧烈的身体运动",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},995449,"为防止静电危害，在装、卸油现场，应将所有正常时不带电的导体连通成整体并接地。下列装油操作步骤，正确的是（）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"先接地后开始装油，结束时先断开接地线后停止装油",{"key":24,"text":125,"correct":26},"先接地后开始装油，结束时先停止装油后断开接地线",{"key":28,"text":127,"correct":22},"先开始装油后接地，结束时先停止装油后断开接地线",{"key":31,"text":129,"correct":22},"先开始装油后接地，结束时先断开接地线后停止装油",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},995450,"防止雷电伤害的方法包括设置防雷装置和人身防雷措施，下列关于防雷装置措施的说法中，正确的是（）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"避雷器在正常时处在导通的状态，出现雷击时切断电路，雷电过后又恢复成导通状态",{"key":24,"text":137,"correct":26},"电涌保护器无冲击波时表现为高阻抗，冲击到来时急剧转变为低阻抗",{"key":28,"text":139,"correct":22},"防雷接地装置严禁和其他接地装置共用",{"key":31,"text":141,"correct":22},"第一类防雷建筑物防止二次放电的最小距离不得小于5m",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":28,"analysis":33},995451,"绝缘是防止直接接触电击的基本措施之一，电气设备的绝缘电阻应经常检测。绝缘电阻用兆欧表测定。下列关于绝缘电阻测定的做法中，正确的是()。",[146,148,150,152],{"key":20,"text":147,"correct":22},"在电动机满负荷运行情况下进行测量",{"key":24,"text":149,"correct":22},"在电动机空载运行情况下进行测量",{"key":28,"text":151,"correct":26},"在电动机断开电源情况下进行测量",{"key":31,"text":153,"correct":22},"在电动机超负荷运行情况下进行测量",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":28,"analysis":33},995452,"变压器内的固体绝缘衬垫、纸板、棉纱、布、木材等都属于可燃物质，不但火灾危险性较大，而且还有爆炸危险的是()。",[158,159,160,161],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":20,"analysis":33},995453,"Ⅱ类设备是带有双重绝缘结构和加强绝缘结构的设备。下列图片所示的电气设备中。Ⅱ类设备是()。",[166,167,168,169],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":31,"analysis":33},995454,"下列关于使用手持电动工具和移动式电气设备说法中，错误的是()。",[174,176,178,180],{"key":20,"text":175,"correct":22},"I类设备必须采取保护接地或保护接零措施",{"key":24,"text":177,"correct":22},"一般场所，手持电动工具应采用Ⅱ类设备",{"key":28,"text":179,"correct":22},"单相设备的相线和中性线上都应该装有熔断器，并装有双极开关",{"key":31,"text":181,"correct":26},"在潮湿或金属构架等导电性能良好的作业场所，应使用Ⅰ类设备",{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":20,"analysis":33},995455,"电气设备的防触电保护可分为四类，各类设备使用时对附加安全措施的装接要求不同。下列关于电气设备装接保护接地的说法中，正确的是( )。",[186,188,190,192],{"key":20,"text":187,"correct":26},"Ⅰ类设备必须装接保护接地",{"key":24,"text":189,"correct":22},"Ⅰ类设备可以装接也允许不装接保护接地",{"key":28,"text":191,"correct":22},"Ⅱ类设备必须装接保护接地",{"key":31,"text":193,"correct":22},"Ⅲ类设备应装接保护接地",{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":28,"analysis":33},995456,"下列关于使用手持电动工具和移动式电气设备的说法中，错误的是( )。",[198,199,201,203],{"key":20,"text":175,"correct":22},{"key":24,"text":200,"correct":22},"一般场所，手持电动工具采用Ⅱ类设备",{"key":28,"text":202,"correct":26},"Ⅱ类设备带电部分与可触及导体之间的绝缘电阻不低于2 MΩ",{"key":31,"text":204,"correct":22},"在潮湿或金属构架等导电性能好的作业场所，主要应使用Ⅱ类或Ⅲ类设备",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":28,"analysis":33},995457,"测量绝缘电阻常用的设备是兆欧表。下列关于兆欧表的使用要求中，错误的是( )。",[209,211,213,215],{"key":20,"text":210,"correct":22},"被测量设备必须在停电状态下测量",{"key":24,"text":212,"correct":22},"测量应尽可能在设备刚停止运转时进行",{"key":28,"text":214,"correct":26},"对于有较大电容的设备，可以断电后直接进行测量",{"key":31,"text":216,"correct":22},"兆欧表与接地电阻测量仪、谐波测试仪、红外测温仪统称为电气安全检测仪",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":24,"analysis":33},995458,"双重绝缘是兼防直接接触电击和间接接触电击的措施。Ⅱ类设备就是靠双重绝缘进行防护的设备。下列关于Ⅱ类设备双重绝缘的说法中，错误的是（ ）。",[221,223,225,227],{"key":20,"text":222,"correct":22},"具有双重绝缘的设备，工作绝缘电阻不低于2MΩ，保护绝缘电阻不低于5MΩ",{"key":24,"text":224,"correct":26},"Ⅱ类设备在采用双重绝缘的基础上可以再次接地以保证安全",{"key":28,"text":226,"correct":22},"Ⅱ类设备在明显位置处必须有“回”形标志",{"key":31,"text":228,"correct":22},"潮湿场所及金属构架上工作时，应尽量选择Ⅱ类设备",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":31,"analysis":33},995459,"现代居民所使用的电流通常是从电站输出后经过长距离输电线路输送后，经过变压器转换为低电压后进入配电箱和配电柜，再从配电箱和配电柜由电力线路输送到各个用电器。下列关于电力线路的安全管理中，说法错误的是（）。",[233,235,237,239],{"key":20,"text":234,"correct":22},"导线应尽量平滑顺直，工作中应尽可能减少导线的接头",{"key":24,"text":236,"correct":22},"接头过多导线不宜使用，导线连接必须紧密",{"key":28,"text":238,"correct":22},"铜导线与铝导线之间连接应尽量采用铜-铝过渡接头",{"key":31,"text":240,"correct":26},"导线连接处的力学强度不得低于原导线力学强度的60%",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":28,"analysis":33},995460,"油浸纸绝缘电缆是火灾危险性比较大的电气装置。下列情况中不属于电缆线路起火的原因是（）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"电缆终端头密封不良，受潮后发生击穿短路",{"key":24,"text":248,"correct":22},"电缆接头的中间接头因压接不紧，焊接不良，导致运行中接头氧化发热",{"key":28,"text":250,"correct":26},"电源电压波动、频率过低",{"key":31,"text":252,"correct":22},"电缆严重过载，发热量剧增，引燃表面积尘",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":31,"analysis":33},995461,"下列关于变电站安全的说法不正确的是（）",[257,259,261,263],{"key":20,"text":258,"correct":22},"变配电站应避开易燃易爆环境",{"key":24,"text":260,"correct":22},"室内油量600kg 以上的充油设备必须有事故蓄油设施",{"key":28,"text":262,"correct":22},"蓄电池室、变压器室、电力电容器室应有良好的通风。",{"key":31,"text":264,"correct":26},"变配电站各间隔的门应向内开启",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":24,"analysis":33},995462,"下列关于建筑物防雷措施的说法中不正确的是（）",[269,271,273,275],{"key":20,"text":270,"correct":22},"各类防雷建筑物均应设置防直击雷的外部防雷装置并应采取防闪电电涌侵入的措施",{"key":24,"text":272,"correct":26},"高压架空电力线路、变电站等可不采取防直击雷。",{"key":28,"text":274,"correct":22},"第一类防雷建筑物，要求装设独立接闪杆、架空接闪线或网",{"key":31,"text":276,"correct":22},"闪电感应的防护主要有静电感应防护和电磁感应防护两方面",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":31,"analysis":33},995463,"下列关于防雷装置的说法中正确的是（）",[281,283,285,287],{"key":20,"text":282,"correct":22},"内部防雷装置由接闪器、引下线和接地装置组成",{"key":24,"text":284,"correct":22},"接闪器用于将雷电流从接闪器传导至接地装置",{"key":28,"text":286,"correct":22},"防直击雷的专设引下线距建筑物出入口或人行道边沿不宜小于10 米",{"key":31,"text":288,"correct":26},"独立接闪杆的冲击接地电阻不宜大于10Ω",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":31,"analysis":33},995464,"当通风良好时，应降低爆炸危险区域等级。良好的通风标志是混合物中危险物质的浓度被稀释到爆炸下限的（）以下。",[293,295,297,299],{"key":20,"text":294,"correct":22},"12%",{"key":24,"text":296,"correct":22},"18%",{"key":28,"text":298,"correct":22},"22%",{"key":31,"text":300,"correct":26},"25%",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":20,"analysis":33},995465,"根据爆炸性气体混合物出现的频繁程度和持续时间，对危险场所分区，下列划分正确的是（）",[305,307,309,311],{"key":20,"text":306,"correct":26},"油罐内部液面上部空间为0 区",{"key":24,"text":308,"correct":22},"油罐顶上呼吸阀附近为2 区",{"key":28,"text":310,"correct":22},"油罐内部液面上部空间为20 区",{"key":31,"text":312,"correct":22},"油罐顶上呼吸阀附近为21 区",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":31,"analysis":33},995466,"在保护接零系统中，当保护零线与相线的材料相同的时候，下列说法正确的是（）",[317,319,321,323],{"key":20,"text":318,"correct":22},"当相线截面积为12mm2，保护零线截面积为6mm2",{"key":24,"text":320,"correct":22},"当相线截面积为20mm2，保护零线截面积为10mm2",{"key":28,"text":322,"correct":22},"当相线截面积为30mm2，保护零线截面积为15mm2",{"key":31,"text":324,"correct":26},"当相线截面积为40mm2，保护零线截面积为20mm2",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":24,"analysis":33},995467,"保护接零的安全原理中，其第一位的安全作用是（）",[329,331,333,335],{"key":20,"text":330,"correct":22},"将故障电压降低到安全范围以内",{"key":24,"text":332,"correct":26},"通过短路保护元件迅速切断电源",{"key":28,"text":334,"correct":22},"将电源电压降低到安全范围以内",{"key":31,"text":336,"correct":22},"通过漏电保护器迅速切断电源",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":28,"analysis":33},995468,"电气装置故障危害是由于电能或控制信息在传递、分配、转换过程中失去控制而产生的。当排放有毒气体的风机停转，致使有毒气体超过允许浓度危及人身安全。上述危险状态产生的直接原因是( )。",[341,343,345,347],{"key":20,"text":342,"correct":22},"爆炸",{"key":24,"text":344,"correct":22},"异常带电",{"key":28,"text":346,"correct":26},"异常停电",{"key":31,"text":348,"correct":22},"安全相关系统失效",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":31,"analysis":33},995469,"下列建筑物防雷分类不正确的是（ ）。",[353,355,357,359],{"key":20,"text":354,"correct":22},"火药制造车间属于第一类防雷建筑物",{"key":24,"text":356,"correct":22},"国家档案馆属于第二类防雷建筑物",{"key":28,"text":358,"correct":22},"北京市历史博物馆属于第三类防雷建筑物",{"key":31,"text":360,"correct":26},"5A 级自然景区属于第四类防雷建筑物",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":28,"analysis":33},995470,"根据爆炸性危险物质的不同，将防爆电气设备又分为3 类，下列防爆电气设备的选择合理的是（ ）。",[365,367,369,371],{"key":20,"text":366,"correct":22},"爆炸性气体场所选用Ⅲ类电气设备",{"key":24,"text":368,"correct":22},"爆炸性粉尘场所选用Ⅱ类电气设备",{"key":28,"text":370,"correct":26},"煤矿瓦斯气体环境场所选用I 类电气设备",{"key":31,"text":372,"correct":22},"爆炸性纤维场所选用I 类电气设备",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":24,"analysis":33},995471,"电气设备的外壳防护等级用“IP+数字+数字”表示。下列对IP66 的解释中,正确的是（ ）。",[377,379,381,383],{"key":20,"text":378,"correct":22},"“IP66”表示“防止直径不小于1.0mm 的金属线接近危险部件,尘密；防短时间浸水",{"key":24,"text":380,"correct":26},"“IP66”表示防止直径不小于1.0mm 的金属线接近危险部位；尘密；防强烈喷水",{"key":28,"text":382,"correct":22},"“IP66”表示防止工具接近危险部位；防止直径不小于2.5mm 的固体异物；防短时间浸水",{"key":31,"text":384,"correct":22},"“IP66”表示防止手指接近危险部位；防止直径不小于12.5mm 的固体异物；防止垂直方向滴水",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":20,"analysis":33},995472,"下列关于IT 系统的安全原理说法正确的是（ ）。",[389,391,393,395],{"key":20,"text":390,"correct":26},"可以把故障电压限制在安全范围内，但是不能切断电源",{"key":24,"text":392,"correct":22},"不可以把故障电压限制在安全范围内，也不能切断电源",{"key":28,"text":394,"correct":22},"可以把故障电压限制在安全范围内，也能切断电源",{"key":31,"text":396,"correct":22},"不可以把故障电压限制在安全范围内，但能切断电源",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":28,"analysis":33},995473,"下列关于TT 系统的安全原理说法正确的是（ ）。",[401,403,405,407],{"key":20,"text":402,"correct":22},"一般不能将触电危险性降低到安全范围以内，靠保护电器切断故障",{"key":24,"text":404,"correct":22},"可以将触电危险性降低到安全范围以内，靠保护电器切断故障",{"key":28,"text":406,"correct":26},"一般不能将触电危险性降低到安全范围以内，靠漏电保护器切断切断故障",{"key":31,"text":408,"correct":22},"可以将触电危险性降低到安全范围以内，靠漏电保护器切断切断故障",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":28,"analysis":33},995474,"下列关于电气的防触电保护分类说法正确的是（ ）。",[413,415,417,419],{"key":20,"text":414,"correct":22},"0 类设备不仅靠基本绝缘作为防触电保护的设备，还包括一种附加的安全措施",{"key":24,"text":416,"correct":22},"0I 类设备和I 类设备对于环境要求过于苛刻，使用范围受到局限",{"key":28,"text":418,"correct":26},"Ⅱ类设备不采用保护接地的措施，也不依赖于安装条件",{"key":31,"text":420,"correct":22},"Ⅲ类设备对保护接地没有要求",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":31,"analysis":33},995475,"防爆电气设备的标志中表示该设备为隔爆型，保护等级为Gb，用于ⅡB 类T3 组爆炸性气体环境的防爆电气设备的是（）",[425,427,429,431],{"key":20,"text":426,"correct":22},"Ex p ⅡB T3 Gb",{"key":24,"text":428,"correct":22},"Ex i ⅡB T3 Gb",{"key":28,"text":430,"correct":22},"Ex m ⅡB T3 Gb",{"key":31,"text":432,"correct":26},"Ex d ⅡB T3 Gb",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":28,"analysis":33},995476,"下列装置是用于限制瞬态过电压和分泄电涌电流的器件。其作用是把窜入电力线、信号传输线的瞬态过电压限制在设备或系统所能承受的电压范围内，或将强大的雷电流泄流入地，防止设备或系统遭受闪电电涌冲击而损坏的是（）",[437,439,441,443],{"key":20,"text":438,"correct":22},"屏蔽导体",{"key":24,"text":440,"correct":22},"等电位连接件",{"key":28,"text":442,"correct":26},"电涌保护器",{"key":31,"text":444,"correct":22},"避雷器",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":28,"analysis":33},995477,"根据粉尘、纤维或飞絮的可燃性物质与空气形成的混合物出现的频率和持续时间及粉尘层厚度进行分类，其中异常情况下，可燃性粉尘云偶尔出现并且只是短时间存在、或可燃性粉尘的场所应当划分为（）",[449,451,453,455],{"key":20,"text":450,"correct":22},"20 区",{"key":24,"text":452,"correct":22},"21 区",{"key":28,"text":454,"correct":26},"22 区",{"key":31,"text":456,"correct":22},"23 区",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":31,"analysis":33},995478,"下列属于事故电火花和电弧的是( )。",[461,463,465,467],{"key":20,"text":462,"correct":22},"控制器接通和断开线路时会产生电火花",{"key":24,"text":464,"correct":22},"直流电动机的电刷与换向器的滑动接触处",{"key":28,"text":466,"correct":22},"断路器接通和断开线路时会产生电火花",{"key":31,"text":468,"correct":26},"雷电直接放电及二次放电火花",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":20,"analysis":33},995479,"下列关于静电接地说法不正确的是（）",[473,475,477,479],{"key":20,"text":474,"correct":26},"静电接地属于静电消失的中和",{"key":24,"text":476,"correct":22},"在静电危险场所，所有属于静电导体的物体必须接地",{"key":28,"text":478,"correct":22},"凡用来加工、储存、运输各种易燃液体、易燃气体和粉体的设备都必须接地",{"key":31,"text":480,"correct":22},"工厂或车间的氧气、乙炔等管道必须连成一个整体，并予以接地",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":31,"analysis":33},995480,"下列低压保护电器可以实现过载保护的是（）",[485,487,489,491],{"key":20,"text":486,"correct":22},"管式熔断器",{"key":24,"text":488,"correct":22},"插式熔断器",{"key":28,"text":490,"correct":22},"螺塞式熔断器",{"key":31,"text":492,"correct":26},"热继电器",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":31,"analysis":33},995481,"雷电具有电性质、热性质和机械性质等三方面的破坏作用。其中属于机械破坏性质的是( )",[497,499,501,503],{"key":20,"text":498,"correct":22},"烧断电线或劈裂电杆",{"key":24,"text":500,"correct":22},"绝缘损坏可能引起短路，导致火灾或爆炸事故",{"key":28,"text":502,"correct":22},"使金属熔化、飞溅引发火灾或爆炸",{"key":31,"text":504,"correct":26},"被击物缝隙中的气体剧烈膨胀导致被击物破坏",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":28,"analysis":33},995482,"某工厂电气设备和线路的供电电压是380V，则该工厂的电气设备和线路的绝缘电阻不得低于（）",[509,511,513,515],{"key":20,"text":510,"correct":22},"1000Ω",{"key":24,"text":512,"correct":22},"1MΩ",{"key":28,"text":514,"correct":26},"380000Ω",{"key":31,"text":516,"correct":22},"220000Ω",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":24,"analysis":33},995483,"按照爆炸性气体混合物出现的频繁程度和持续时间存在一级释放源的场所，应当划分为（ ）。",[521,523,525,527],{"key":20,"text":522,"correct":22},"0 区",{"key":24,"text":524,"correct":26},"1 区",{"key":28,"text":526,"correct":22},"2 区",{"key":31,"text":528,"correct":22},"3 区",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":20,"analysis":33},995484,"下列系统适用于有爆炸危险、火灾危险性大及其他安全要求高的场所的是（ ）。",[533,534,535,536],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":20,"analysis":33},995485,"静电危害是由静电电荷或静电场能量引起的。静电电压可能高达数十千伏以上，容易产生放电火花。下列关于静电的危害形式和事故后果的说法中，正确的是( )。",[541,543,545,547],{"key":20,"text":542,"correct":26},"生产工艺过程中产生的静电,其能量不大，不会直接使人致命",{"key":24,"text":544,"correct":22},"静电产生的电火花,能量不大,不会成为点火源",{"key":28,"text":546,"correct":22},"静电的电压一般不会超过几百伏",{"key":31,"text":548,"correct":22},"静电会影响电子产品质量,但不会损坏电子设备",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":24,"analysis":33},995486,"下列情况不会产生危险温度的是（ ）。",[553,555,557,559],{"key":20,"text":554,"correct":22},"电气接头连接不牢",{"key":24,"text":556,"correct":26},"铜、铝接头采用铜铝过度接头",{"key":28,"text":558,"correct":22},"断路器的接触处含有过多的杂质",{"key":31,"text":560,"correct":22},"铁心过热",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":20,"analysis":33},995487,"根据电击时，所触及的带电体是否为正常带电状况,分为直接接触电击和间接接触电击,下列属于直接接触电击的是( )。",[565,567,569,571],{"key":20,"text":566,"correct":26},"换灯泡的时候,没有关开关,而直接触碰到火线端子",{"key":24,"text":568,"correct":22},"操作砂轮机的时候,当手触碰到砂轮机的外壳的时候,漏电保护器切断电源",{"key":28,"text":570,"correct":22},"人体碰到漏电的金属防护罩引起的电击",{"key":31,"text":572,"correct":22},"高压线掉落地面引起的电击",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":31,"analysis":33},995488,"下列关于电流的影响因素说法中不正确的是( )。",[577,579,581,583],{"key":20,"text":578,"correct":22},"室颤电流的大小与电流的持续时间有关系",{"key":24,"text":580,"correct":22},"电流危险性最大的途径是指流经心脏电流最多,线路最短的途径",{"key":28,"text":582,"correct":22},"电击对人体的伤害程度是因人而异的",{"key":31,"text":584,"correct":26},"人在除去角质层,干燥的情况下,人体的电阻值约为500-800Ω",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":20,"analysis":33},995489,"下列关于电击的说法中正确的是( )。",[589,591,593,595],{"key":20,"text":590,"correct":26},"电击时电流通过人体对人体造成的伤害",{"key":24,"text":592,"correct":22},"男性的感知电流约为0.7mA",{"key":28,"text":594,"correct":22},"男性的摆脱电流平均值为10.5mA",{"key":31,"text":596,"correct":22},"室颤电流指引起心室发生心室纤维性颤动的最大电流",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":28,"analysis":33},995492,"感知电流，挡在一定概率下，通过人体的使人有感觉的最小电流。感知概率为50%的平均感知电流，成年男子约为（ ）mA。",[601,603,605,607],{"key":20,"text":602,"correct":22},"0.5",{"key":24,"text":604,"correct":22},"0.7",{"key":28,"text":606,"correct":26},"1.1",{"key":31,"text":608,"correct":22},"1.5",[610,613,616,619,622,625],{"id":15,"name":611,"category":7,"favorite":612},"领导干部任职前廉政法规知识测试题",92,{"id":614,"name":615,"category":7,"favorite":15},595,"建筑结构与设备",{"id":617,"name":618,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":620,"name":621,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":623,"name":624,"category":7,"favorite":8},534,"BIM工程师",{"id":626,"name":624,"category":7,"favorite":8},535]