[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-729-12":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":610},{"id":5,"name":6,"category":7,"favorite":8},729,"安全生产技术基础","建筑工程",0,12,50,1831,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,295,307,319,331,343,352,363,375,387,399,411,423,435,445,457,469,481,493,505,517,529,541,551,563,575,587,599],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},995391,1,"单选题","为了防止触电事故和电气火灾事故的发生，某企业拟采用屏护与间距的方式作为电气安全措施。该企业设置的屏护与间距的情况中，不符合安全管理规定的是（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","企业中35kV高压输电线导线与建筑物的水平距离为5m",false,{"key":24,"text":25,"correct":26},"B","架空线路在跨越可燃材料屋顶建筑物时采取了防爆措施",true,{"key":28,"text":29,"correct":22},"C","企业规定，员工在低压操作时，人体与所携带工具质检距离不小于0.1m",{"key":31,"text":32,"correct":22},"D","企业规定，对金属材料制成的屏护装置必须可靠连接保护线","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},995392,"保持安全间距是一项重要的电气安全措施。在10kV元遮拦作业中，人体及其所携带工具与带电体之间最小距离为（）m。",[38,40,42,44],{"key":20,"text":39,"correct":26},"0.7",{"key":24,"text":41,"correct":22},"0.5",{"key":28,"text":43,"correct":22},"0.35",{"key":31,"text":45,"correct":22},"1.0",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},995393,"保护接零的安全原理是当电气设备漏电时形成的单相短路促使线路上的短路保护元件迅速动作切断漏电设备的电源。因此保护零线必须有足够的截面。当相线截面为10mm 2 时，保护零线的截面不应小于（）mm 2 。",[50,52,54,56],{"key":20,"text":51,"correct":22},"2.5",{"key":24,"text":53,"correct":22},"4",{"key":28,"text":55,"correct":22},"6",{"key":31,"text":57,"correct":26},"10",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},995394,"有电击危险环境中使用的手持照明灯和局部照明灯应采用的安全特低电压种类是（）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"50V",{"key":24,"text":65,"correct":22},"42V",{"key":28,"text":67,"correct":26},"24V",{"key":31,"text":69,"correct":22},"6V",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},995395,"保护接零是为了防止电击事故而采取的安全措施，在变压器的中性点接地系统中，当某相带电体碰连设备外壳时，可能造成电击事故。关于保护接零的说法，正确的是（）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"保护接零能将漏电设备上的故障电压降低到安全范围以内，但不能迅速切断电源",{"key":24,"text":77,"correct":22},"保护接零既能将漏电设备上的故障电压降低到安全范围以内，又能迅速切断电源",{"key":28,"text":79,"correct":22},"保护接零既不能将漏电设备上的故障电压降低到安全范围以内，也不能迅速切断电源",{"key":31,"text":81,"correct":26},"保护接零一般不能将漏电设备上的故障电压降低到安全范围以内，但可以迅速切断电源",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},995396,"所有电气装置都必须具备防止电气伤害的直接接触防护和间接接触防护下列防护措施中，属于防止直接接触电击的防护措施是（）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"利用避雷器防止雷电伤害",{"key":24,"text":89,"correct":26},"利用绝缘体对带电体进行封闭和隔离",{"key":28,"text":91,"correct":22},"IT系统",{"key":31,"text":93,"correct":22},"TN系统",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},995397,"兼防直接接触和间接接触电击的措施包括双重绝缘、安全电压、剩余电流动作保护。其中，剩余电流动作保护的工作原理是（）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"通过电气设备上的保护接零线把剩余电流引人大地",{"key":24,"text":101,"correct":22},"保护接地经剩余电流构成接地电阻从而导致熔断器熔断以后切断电源",{"key":28,"text":103,"correct":26},"由零序电流互感器获取漏电信号，经转换后使线路开关跳闸",{"key":31,"text":105,"correct":22},"剩余电流直接促使电气线路上的保护元件迅速动作断开电源",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},995398,"双重绝缘是兼防直接接触电击和间接接触电击的措施。Ⅱ类设备就是靠双重绝缘进行防护的设备。下列关于Ⅱ类设备双重绝缘的说法中，错误的是（）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"具有双重绝缘的设备，工作绝缘电阻不低于2MΩ，保护绝缘电阻不低于5MΩ",{"key":24,"text":113,"correct":26},"Ⅱ类设备在采用双重绝缘的基础上可以再次接地以保证安全",{"key":28,"text":115,"correct":22},"Ⅱ类设备在明显位置处必须有“回”形标志",{"key":31,"text":117,"correct":22},"潮湿场所及金属构架上工作时，应尽量选择Ⅱ类设备",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":28,"analysis":33},995399,"下列关于使用手持电动工具和移动式电气设备的说法中，错误的是（）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"Ⅰ类设备必须采取保护接地或保护接零措施",{"key":24,"text":125,"correct":22},"一般场所，手持电动工具采用Ⅱ类设备",{"key":28,"text":127,"correct":26},"Ⅱ类设备带电部分与可触及导体之间的绝缘电阻不低于2MΩ。",{"key":31,"text":129,"correct":22},"在潮湿或金属构架等导电性能好的作业场所主要应使用Ⅱ类或Ⅲ类设备",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":33},995400,"在建筑物的进线处将PE干线、设备PE干线、进水管、采暖和空调竖管、建筑物构筑物金属构件和其他金属管道、装置外露可导电部分等相联结，此措施称为（）。",[134,136,138,140],{"key":20,"text":135,"correct":26},"主等电位联结",{"key":24,"text":137,"correct":22},"主等电位保护",{"key":28,"text":139,"correct":22},"辅助等电位保护",{"key":31,"text":141,"correct":22},"辅助等电位联结",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},995401,"漏电保护又称为剩余电流保护。危险性较大的TT防护系统必须安装剩余电流动作保护器作为保护。但是，漏电保护不是万能的，保护不包括相与相之间，相与N线之间形成的直接接触触电事故.下列触电状态中，漏电保护不能起保护作用的是（）。",[146,148,150,152],{"key":20,"text":147,"correct":26},"人站在塑料凳上同时触及相线和中性线",{"key":24,"text":149,"correct":22},"人站在地上触及一根火线",{"key":28,"text":151,"correct":22},"人站在地上触及漏电设备的金属外壳",{"key":31,"text":153,"correct":22},"人坐在接地的金属台上触及一根带电导线",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":31,"analysis":33},995402,"额定剩余动作电流是制造厂对剩余电流保护装置规定的剩余动作电流，在该电流时，剩余电流动作保护装置在规定的条件下动作，该值反映了剩余电流动作保护装置的灵敏度。下列额定剩余动作电流中属于高灵敏度的是（）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"100mA",{"key":24,"text":161,"correct":22},"0.05A",{"key":28,"text":163,"correct":22},"0.3A",{"key":31,"text":165,"correct":26},"30mA",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":28,"analysis":33},995403,"电气设备安全防护不仅要求要能够防止人身触电事故，更重要的是防止发生群死群伤的电气火灾和爆炸事故。下列关于电气防火防爆的要求中，错误的是（）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"对于接零和接地保护系统中，所有金属部分应接地并连接成整体",{"key":24,"text":173,"correct":22},"对于接零和接地保护系统中，不接地的部分应实行等电位连接",{"key":28,"text":175,"correct":26},"如电气设备发生火灾，灭火时应采用绝缘工具操作，先断隔离开关，后断开断路器",{"key":31,"text":177,"correct":22},"如需剪断电线，剪断电线位置应在电源、方向支持点附近，以防电线掉落下来短路",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":28,"analysis":33},995404,"保护接零系统中要求有合格的工作接地和合格的保护导体面积。下列关于保护接零系统中接地装置和保护导体的说法中，正确的是（）。",[182,184,186,188],{"key":20,"text":183,"correct":22},"铜制PEN线截面积不得小于16mm 2",{"key":24,"text":185,"correct":22},"没有机械防护的PE线截面积不得小于2.5mm 2",{"key":28,"text":187,"correct":26},"接地装置与公路交叉口可能受到损伤处应穿管或用角钢保护",{"key":31,"text":189,"correct":22},"接地导体与独立避雷针之间的距离小于1m，离建筑物的距离等于1m",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":31,"analysis":33},995405,"接零保护系统中，要求发生对PE线的单相短路时，能够迅速切断电源对于相线对地电压220TN系统，手持式电气设备的短路保护元件应保证故障持续时间不超过（）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"5s",{"key":24,"text":197,"correct":22},"0.2s",{"key":28,"text":199,"correct":22},"1s",{"key":31,"text":201,"correct":26},"0.4s",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":28,"analysis":33},995406,"测量绝缘电阻常用的设备是兆欧表。下列关于兆欧表的使用要求中，错误的是（）。",[206,208,210,212],{"key":20,"text":207,"correct":22},"被测量设备必须在停电状态下测量",{"key":24,"text":209,"correct":22},"测量应尽可能在设备停止运行，冷却后进行测量",{"key":28,"text":211,"correct":26},"对于有较大电容的设备，可以断电后直接进行测量",{"key":31,"text":213,"correct":22},"兆欧表与接地电阻测量仪谐波测试仪红外测温仪统称为电气安全检测仪",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":20,"analysis":33},995407,"电气设备的防触电保护可分为四类，各类设备使用时对附加安全措施的装接要求不同。下列关于电气设备装接保护接地的说法中，正确的是（）。",[218,220,222,224],{"key":20,"text":219,"correct":26},"Ⅰ类设备必须装接保护接地",{"key":24,"text":221,"correct":22},"Ⅰ类设备可以装接也允许不装接保护接地",{"key":28,"text":223,"correct":22},"Ⅱ类设备必须装接保护接地",{"key":31,"text":225,"correct":22},"Ⅲ类设备应装接保护接地",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":28,"analysis":33},995408,"间接接触电击是人体触及非正常状态下带电的带电体时发生的电击。预防间接接触电击的正确措施是（）。",[230,232,234,236],{"key":20,"text":231,"correct":22},"绝缘、屏护和间距",{"key":24,"text":233,"correct":22},"保护接地、屏护",{"key":28,"text":235,"correct":26},"保护接地、保护接零",{"key":31,"text":237,"correct":22},"绝缘、保护接零",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":20,"analysis":33},995409,"在释放源的等级中，正常运行时周期性释放或偶然释放的是()。",[242,244,246,248],{"key":20,"text":243,"correct":26},"一级释放源",{"key":24,"text":245,"correct":22},"二级释放源",{"key":28,"text":247,"correct":22},"连续级释放源",{"key":31,"text":249,"correct":22},"多级释放源",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":28,"analysis":33},995410,"甲烷的爆炸极限为（）",[254,256,258,260],{"key":20,"text":255,"correct":22},"1.4%~7.6%",{"key":24,"text":257,"correct":22},"1.5%~8%",{"key":28,"text":259,"correct":26},"5%~15%",{"key":31,"text":261,"correct":22},"5%~20%",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":20,"analysis":33},995411,"根据爆炸性气体混合物出现的频繁程度和持续时间，对危险场所分区，分为0区、1区、2区。根据爆炸性气体环境危险区域范围典型示例图(下图)中可以看出，图中为易燃物质重于空气、设在户外地坪上的浮顶式贮罐，箭头标记处应划分为的区域为( )。",[266,268,270,272],{"key":20,"text":267,"correct":26},"0区",{"key":24,"text":269,"correct":22},"1区",{"key":28,"text":271,"correct":22},"2区",{"key":31,"text":273,"correct":22},"3区",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":24,"analysis":33},995412,"通风条件和释放源的等级综合决定了环境的爆炸危险性。同时，释放源也是划分爆炸危险区域的基础。下列关于爆炸危险区域的划分和释放源的说法中，正确的是( )。",[278,280,282,284],{"key":20,"text":279,"correct":22},"一级释放源是连续、长时间释放或短时间频繁释放的释放源",{"key":24,"text":281,"correct":26},"包含连续级释放源的区域可划分为0区",{"key":28,"text":283,"correct":22},"二级释放源是正常运行时周期性释放或偶然释放的释放源",{"key":31,"text":285,"correct":22},"包含一级释放源的区域可划分为0区",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":28,"analysis":33},995413,"电气设备安全防护不仅要求要能够防止人身触电事故，更重要的是防止发生群死群伤的电气火灾和爆炸事故。下列关于电气防火防爆的要求中，错误的是( )。",[290,291,292,293],{"key":20,"text":171,"correct":22},{"key":24,"text":173,"correct":22},{"key":28,"text":175,"correct":26},{"key":31,"text":294,"correct":22},"如需剪断电线，剪断电线位置应在电源方向支持点附近，以防电线掉落下来短路",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":24,"analysis":33},995414,"剩余电流动作保护又称为漏电保护，是利用 剩余电流动作保护装置来防止电气事故的一种安全技术措施。其装置和工作原理图如下，下列关于剩余电流动作保护的工作原理说法正确是（ ）。",[299,301,303,305],{"key":20,"text":300,"correct":22},"M电动机漏电，人触碰后形成短路，促使中间环节TL动作，发出信号导致熔断器熔断以切断供电电源",{"key":24,"text":302,"correct":26},"TA表示零序电流互感器，由TA获取漏电信号，经中间环节放大电信号,使QF跳闸",{"key":28,"text":304,"correct":22},"M电动机外壳发生漏电，能够通过电气设备上的保护接触线把剩余电流引入大地",{"key":31,"text":306,"correct":22},"剩余电流直接促使电气线路上的保护元件迅速动作断开供电电源",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":28,"analysis":33},995415,"对于有爆炸性危险的环境要使用与其危险相对应的防爆电气设备。下列关于防爆电气设备分类的说法中，错误的是（ ）。",[311,313,315,317],{"key":20,"text":312,"correct":22},"Ⅰ类电气设备适用于煤矿瓦斯气体环境，Ⅱ类电气设备用于煤矿甲烷以外的爆炸性气体环境",{"key":24,"text":314,"correct":22},"Ⅲ类电气设备用于爆炸性粉尘环境",{"key":28,"text":316,"correct":26},"对于Ⅱ类电气设备分级中，保护等级的排序为Ga\u003CGb\u003CGc",{"key":31,"text":318,"correct":22},"对于Ⅲ类电气设备分级中，保护等级的排序为Da>Db>Dc",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":24,"analysis":33},995416,"对危险物质进行分类、分组，目的在于便于对不同的危险物质进行管理，在划分的过程中，主要将爆炸性危险物质划分为三类：Ⅰ类、Ⅱ类、Ⅲ类。下列属于Ⅱ类危险物质的是（）。",[323,325,327,329],{"key":20,"text":324,"correct":22},"矿井甲烷",{"key":24,"text":326,"correct":26},"氢气",{"key":28,"text":328,"correct":22},"可燃性粉尘",{"key":31,"text":330,"correct":22},"人造纤维飞絮",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":31,"analysis":33},995417,"电气设备的外壳防护等级用“IP+数字+数字”表示。下列对标志含义的解释中，正确的是（）。",[335,337,339,341],{"key":20,"text":336,"correct":22},"“IP45”表示”防止工具接近危险部件，防止直径不小于2.5mm固体异物；防喷水”",{"key":24,"text":338,"correct":22},"”IP34”表示”防止工具接近危险部件，防止直径不小于2.5mm固体异物；防淋水”",{"key":28,"text":340,"correct":22},"”IP65”表示”防止直径不小于1.0mm的金属线接近危险部件，尘密；防短时间浸水”",{"key":31,"text":342,"correct":26},"”IP51”表示”防止直径不小于1.0mm的金属线接近危险部件，防尘；防止垂直方向滴水”",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":20,"analysis":33},995418,"根据爆炸性气体混合物出现的频繁程度和持续时间，对危险场所分区，分为0区、1区、2区。根据爆炸性气体环境危险区域范围典型示例图（下图）中可以看出，图中为易燃物质重于空气、设在户外地坪上的浮顶式贮罐，箭头标记处应划分为的区域为（）。",[347,349,350,351],{"key":20,"text":348,"correct":26},"O区",{"key":24,"text":269,"correct":22},{"key":28,"text":271,"correct":22},{"key":31,"text":273,"correct":22},{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":28,"analysis":33},995419,"防爆电器应有具体的标志并且应设置在设备外部主体部分的明显地方。以Ex d ⅡB T3 Gb例，下列解释正确的是（）。",[356,358,360,362],{"key":20,"text":357,"correct":22},"表示该设备为正压型&ldquo;d&rdquo;，保护级别为Gb，用于ⅡB类T3组爆炸性气体环境",{"key":24,"text":359,"correct":22},"表示该设备为正压型&ldquo;d&rdquo;，保护级别为Ⅱ用于Gb类T3组爆炸性气体环境",{"key":28,"text":361,"correct":26},"表示该设备为隔爆型&ldquo;d&rdquo;，保护级别为Gb，用于ⅡB类T3组爆炸性气体环境",{"key":31,"text":359,"correct":22},{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":24,"analysis":33},995420,"防爆电器应有具体的标志，并且应设置在设备外部主体部分的明显地方设备为正压型保护等级为Db，用于ⅡB类T3组爆炸性气体环境的防爆电器，下列编号正确的是（）。",[367,369,371,373],{"key":20,"text":368,"correct":22},"Ex d ⅡB T3 Db",{"key":24,"text":370,"correct":26},"Ex p ⅡB T3 Db",{"key":28,"text":372,"correct":22},"Ex o T3 Db ⅡB",{"key":31,"text":374,"correct":22},"Ex d T3 Db ⅡB",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":31,"analysis":33},995421,"具有爆炸性危险的环境需要根据环境危险等级需求，使用专用的防爆电气设备及管线。防爆电气设备的选用具有严格的要求，防爆电器线路的敷设也有严格的要求。下列关于防爆电气设备的选择和线路的敷设要求中，错误的是（）。",[379,381,383,385],{"key":20,"text":380,"correct":22},"危险区域划分为0区的，使用Ⅱ类电气设备时，需使用Ga的防护类别",{"key":24,"text":382,"correct":22},"电气线路应敷设在爆炸危险性较小或距离释放源较远的地方",{"key":28,"text":384,"correct":22},"敷设电气线路的沟道及保护管、电缆或钢管在穿越爆炸危险环境等级不同的区域之间的隔墙或楼板时，应采用非燃性材料严密封堵",{"key":31,"text":386,"correct":26},"煤矿井下可以使用铜芯或铝芯导线作为电缆材料",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":28,"analysis":33},995422,"爆炸性粉尘环境是指在一定条件下，粉尘、纤维或飞絮的可燃物质与空气形成的混合物被点燃后，能够保持燃烧自行传播的环境。根据粉尘、纤维或飞絮的可燃性物质与空气形成的混合物出现的频率和持续时间及粉尘厚度进行分类，将爆炸性危险环境分为（）。",[391,393,395,397],{"key":20,"text":392,"correct":22},"00区、01区、02区",{"key":24,"text":394,"correct":22},"10区、11区、12区",{"key":28,"text":396,"correct":26},"20区、21区、22区",{"key":31,"text":398,"correct":22},"30区、31区、32区",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":28,"analysis":33},995423,"划分爆炸危险区域时应综合考虑释放源级别和通风条件先按释放源级别划分区域，再根据通风条件调整区域划分。关于爆炸危险环境的说法，正确的是（）。",[403,405,407,409],{"key":20,"text":404,"correct":22},"混合物中危险物质的浓度被稀释到爆炸下限的35%以下为通风良好",{"key":24,"text":406,"correct":22},"混合物中危险物质的浓度被稀释到爆炸下限的75%以下为通风不良",{"key":28,"text":408,"correct":26},"存在第一级释放源区域，可划为1区，存在第二级释放源区域，可划为2区",{"key":31,"text":410,"correct":22},"存在连续级释放源区域，可划为1区，存在第一级释放源区域，可划为2区",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":20,"analysis":33},995424,"不同火灾场景应使用相应的灭火剂，选择正确的灭火剂是灭火的关键。下列火灾中，能用水灭火的是（）。",[415,417,419,421],{"key":20,"text":416,"correct":26},"普通木材家具引发的火灾",{"key":24,"text":418,"correct":22},"未切断电源的电气火灾",{"key":28,"text":420,"correct":22},"硫酸、盐酸和硝酸引发的火灾",{"key":31,"text":422,"correct":22},"高温状态下化工设备火灾",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":24,"analysis":33},995425,"爆炸性气体、蒸气按最小点燃电流比（MICR）和最大试验安全间隙（MES G）分为ⅡA级、ⅡB级、ⅡC级。下列关于这三个级别的危险气体危险性排序正确的是（）。",[427,429,431,433],{"key":20,"text":428,"correct":22},"ⅡA级＞ⅡB级＞ⅡC级",{"key":24,"text":430,"correct":26},"ⅡA级＜ⅡB级＜ⅡC级",{"key":28,"text":432,"correct":22},"ⅡA级＜ⅡC级＜ⅡB级",{"key":31,"text":434,"correct":22},"ⅡB级＞ⅡA级＞ⅡC级",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":28,"analysis":33},995426,"对爆炸性粉尘环境，需要根据粉尘与空气形成的混合物出现的频率和持续时间及粉尘层厚度进行分类。若在正常运行中，可燃性粉尘连续出现或经常出现其数量足以形成可燃性粉尘与空气混合物或形成无法控制和极厚的粉尘层的场所及容器内部，此类爆炸性环境应确定为（）。",[439,440,441,443],{"key":20,"text":269,"correct":22},{"key":24,"text":271,"correct":22},{"key":28,"text":442,"correct":26},"20区",{"key":31,"text":444,"correct":22},"21区",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":20,"analysis":33},995427,"在电气设备发生爆炸时，其外壳能承受爆炸性混合物在壳内爆炸时产生的压力，并能阻止爆炸火焰传播到外壳的周围，不致引起外部爆炸性混合物爆炸的防爆电气设备是（）。",[449,451,453,455],{"key":20,"text":450,"correct":26},"隔爆型防爆电气设备",{"key":24,"text":452,"correct":22},"充油型防爆电气设备",{"key":28,"text":454,"correct":22},"本质安全型防爆电气设备",{"key":31,"text":456,"correct":22},"充砂型防爆电气设备",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":24,"analysis":33},995428,"隔爆型电气设备的防爆标志用字母（）标识。",[461,463,465,467],{"key":20,"text":462,"correct":22},"i",{"key":24,"text":464,"correct":26},"d",{"key":28,"text":466,"correct":22},"e",{"key":31,"text":468,"correct":22},"p",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":20,"analysis":33},995429,"雷电是大气中的一种放电现象，具有雷电流幅值大、雷电流陡度大、冲击性强、冲击过电压高等特点。下列关于雷电破坏作用的说法中，正确的是()。",[473,475,477,479],{"key":20,"text":474,"correct":26},"破坏电力设备的绝缘",{"key":24,"text":476,"correct":22},"引起电气设备过负荷",{"key":28,"text":478,"correct":22},"造成电力系统过负荷",{"key":31,"text":480,"correct":22},"引起电动机转速异常",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":24,"analysis":33},995430,"直击雷、闪电感应(雷电感应、感应雷)、球形雷(球雷)、雷击电磁脉冲都可能造成严重事故。下列关于避雷针安全作用的描述中，正确的是()。",[485,487,489,491],{"key":20,"text":486,"correct":22},"避雷针能防闪电静电感应",{"key":24,"text":488,"correct":26},"避雷针能防直击雷",{"key":28,"text":490,"correct":22},"避雷针能防闪电电磁感应",{"key":31,"text":492,"correct":22},"避雷针能防雷击电磁脉冲",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":31,"analysis":33},995431,"有一种防雷装置，正常时处在不通的状态;出现雷击过电压时，击穿放电，切断过电压，发挥保护作用;过电压终止后，迅速恢复不通状态，恢复正常工作，这种装置是()。",[497,499,501,503],{"key":20,"text":498,"correct":22},"接闪器",{"key":24,"text":500,"correct":22},"接地装置",{"key":28,"text":502,"correct":22},"避雷针",{"key":31,"text":504,"correct":26},"避雷器",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":28,"analysis":33},995432,"静电防护措施包括环境危险程度的控制、工艺控制和静电接地等。下列属于环境危险程度的控制是()。",[509,511,513,515],{"key":20,"text":510,"correct":22},"限制物料的运动速度",{"key":24,"text":512,"correct":22},"加大静电消散过程",{"key":28,"text":514,"correct":26},"取代易燃介质",{"key":31,"text":516,"correct":22},"采用位于静电序列中段的金属材料制成生产设备",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":24,"analysis":33},995433,"某黏合剂厂曾发生一起由静电引起的爆炸事故。下图是事故现场简图。汽油桶中装满甲苯．开动空压机后，压缩空气经橡胶软管将甲苯经塑料软管顶入反应釜。开始灌装十几分钟反应釜内发生燃爆，导致6人死亡，1人重伤。橡胶软管内空气流速和塑料软管内甲苯流速都很高。这起事故中．产生危险静电的主要过程是()。",[521,523,525,527],{"key":20,"text":522,"correct":22},"压缩空气在橡胶软管内高速流动",{"key":24,"text":524,"correct":26},"甲苯在塑料软管内高速流动",{"key":28,"text":526,"correct":22},"工作人员在现场走动",{"key":31,"text":528,"correct":22},"空压机合闸送电",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":24,"analysis":33},995434,"雷击有电性质、热性质、机械性质等多方面的破坏作用，并产生严重后果，对人的生命、财产构成很大的威胁。下列各种危险危害中，不属于雷击危险危害的是( )。",[533,535,537,539],{"key":20,"text":534,"correct":22},"二次放电引起的电击事故",{"key":24,"text":536,"correct":26},"导致变压器断路",{"key":28,"text":538,"correct":22},"引起火灾和爆炸",{"key":31,"text":540,"correct":22},"使人遭受致命电击",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":20,"analysis":33},995435,"用于防直击雷的防雷装置中，( )是利用其高出被保护物的地位，把雷电引向自身，起到拦截闪击的作用。",[545,546,548,549],{"key":20,"text":498,"correct":26},{"key":24,"text":547,"correct":22},"引下线",{"key":28,"text":500,"correct":22},{"key":31,"text":550,"correct":22},"屏蔽导体",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":24,"analysis":33},995436,"接闪器的保护范围按照滚球法确定。滚球的半径按建筑物防雷类别确定，一类建筑物的滚球半径为( )。",[555,557,559,561],{"key":20,"text":556,"correct":22},"15 m",{"key":24,"text":558,"correct":26},"30 m",{"key":28,"text":560,"correct":22},"45 m",{"key":31,"text":562,"correct":22},"60 m",{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":20,"analysis":33},995437,"生产工艺过程中所产生静电的最大危险是引起爆炸。因此，在爆炸危险环境必须采取严密的防静电措施。下列各项措施中，不属于防静电措施的有( )。",[567,569,571,573],{"key":20,"text":568,"correct":26},"安装短路保护和过载保护装置",{"key":24,"text":570,"correct":22},"金属导体直接接地",{"key":28,"text":572,"correct":22},"限制流速",{"key":31,"text":574,"correct":22},"增加作业环境的相对湿度",{"id":576,"libraryId":5,"type":15,"typeLabel":16,"stem":577,"options":578,"answer":24,"analysis":33},995438,"当绝缘体受潮或受到过高的温度、过高的电压时，可能完全失去绝缘能力而导电，称为绝缘击穿或绝缘破坏。下列关于绝缘击穿的说法中正确的是（ ）。",[579,581,583,585],{"key":20,"text":580,"correct":22},"气体击穿是碰撞电离导致的电击穿，击穿后绝缘性能不可恢复",{"key":24,"text":582,"correct":26},"液体绝缘的击穿特性与其纯净度有关，纯净液体击穿也是电击穿，密度越大越难击穿",{"key":28,"text":584,"correct":22},"液体绝缘击穿后，绝缘性能能够很快完全恢复",{"key":31,"text":586,"correct":22},"固体绝缘击穿后只能在一定程度上恢复其绝缘性能",{"id":588,"libraryId":5,"type":15,"typeLabel":16,"stem":589,"options":590,"answer":28,"analysis":33},995439,"”这是一种奇怪的现象，它有时爆炸，有时无声而逝，有时在地面上缓慢移动，有时跳跃行走，有时在地面上不高处悬浮……”这句话形容的现象是（）。",[591,593,595,597],{"key":20,"text":592,"correct":22},"直击雷",{"key":24,"text":594,"correct":22},"闪电感应",{"key":28,"text":596,"correct":26},"球雷",{"key":31,"text":598,"correct":22},"雷电感应",{"id":600,"libraryId":5,"type":15,"typeLabel":16,"stem":601,"options":602,"answer":28,"analysis":33},995440,"电磁辐射是以波的形式传送电磁能量，辐射电磁波的波长大致为10mm-3000m。辐射电磁波的频率一般在（）kHz以上",[603,605,606,608],{"key":20,"text":604,"correct":22},"1",{"key":24,"text":57,"correct":22},{"key":28,"text":607,"correct":26},"100",{"key":31,"text":609,"correct":22},"500",[611,614,617,620,623,626],{"id":15,"name":612,"category":7,"favorite":613},"领导干部任职前廉政法规知识测试题",92,{"id":615,"name":616,"category":7,"favorite":15},595,"建筑结构与设备",{"id":618,"name":619,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":621,"name":622,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":624,"name":625,"category":7,"favorite":8},534,"BIM工程师",{"id":627,"name":625,"category":7,"favorite":8},535]