[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-981269":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},981269,709,2,"多选题","桩基设计时，在下述（ ）情况下应考虑负摩阻力的影响。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","中密砂",false,{"key":16,"text":17,"correct":18},"B","桩周存在软弱土层，邻近桩侧地面承受局部较大的长期荷载",true,{"key":20,"text":21,"correct":18},"C","自重湿陷性黄土",{"key":23,"text":24,"correct":18},"D","新近沉积的欠固结土","BCD","根据《建筑桩基技术规范》（JGJ 94—2008）第5. 4. 2条，符合下列条件之一的基桩，当桩周土层产生的沉降超过基桩的沉降时，应考虑桩侧负摩阻力：①桩穿越较厚松散填土、自重湿陷性黄土、欠固结土层，液化土层进入相对较硬土层时；②桩周存在软弱土层，邻近桩侧地面承受局部较大的长期荷载，或地面大面积堆载（包括填土）时； ③由于降低地下水位，使桩周土中有效应力増大，并产生显著压缩沉降时。",{"id":6,"name":28,"category":29,"favorite":30},"岩土专业知识","建筑工程",0]