[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-981177":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},981177,709,2,"多选题","在其他情况相同时，进行液化判别下列（ ）选项不正确。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","实测标准贯入击数相同时，饱和粉细砂的液化可能性大于饱和粉土",false,{"key":16,"text":17,"correct":14},"B","标准贯入点深度相同，上覆非液化土层厚度越大，饱和粉细砂及饱和粉土的液化性越小",{"key":19,"text":20,"correct":21},"C","粉土的黏粒含量越大，实测标准贯入击数越小",true,{"key":23,"text":24,"correct":21},"D","地下水埋深越大，临界标准贯入击数越大","CD","根据《建筑抗震设计规范》（GB 50011 —2010）第4. 3. 3 ~4. 3. 4条，标准贯入击数计算公式为： 式中Ncr为液化判别标准贯入键击数临界值；N0为液化判别标准贯入锤击数基准值；ds为饱和土标准贯入点深度（m）；ρc为黏粒含量百分率，当小于3或土体为砂土时，应采用3。",{"id":6,"name":28,"category":29,"favorite":30},"岩土专业知识","建筑工程",0]