[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-981097":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},981097,709,2,"多选题","地基处理时以下（ ）对处理范围的叙述是不正确的。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","砂石桩处理范围应大于基础范围",false,{"key":16,"text":17,"correct":18},"B","真空预压法的预压范围应等于建筑物基础外缘所包括的范围",true,{"key":20,"text":21,"correct":14},"C","强夯处理范围应大于建筑物基础外缘所包括的范围",{"key":23,"text":24,"correct":18},"D","竖向承载水泥揽拌桩范围应大于建筑物基础范围","BD","根据《建筑地基处理技术规范》（JGJ 79—2002）第5. 2. 17条，真空预压区边缘应大于建筑物基础轮廓线，每边增加量不得小于3.0m，每块预压面积宜尽可能大且呈方形；根据11.2.7条，竖向承载搅拌桩可只在基础平面范围内布置，独立基础下的桩数不宜少于3根。柱状加固可采用正方形、等边三角形等布桩型式。",{"id":6,"name":28,"category":29,"favorite":30},"岩土专业知识","建筑工程",0]