[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-981017":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},981017,709,2,"多选题","埋设于地下水位以下的下埋式水池基础设计时，对于计算条件的下列设定中不正确的是（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","对不需要设置抗浮桩的下埋式水池，计算底板内力时不需要考虑浮力的作用",true,{"key":16,"text":17,"correct":14},"B","如果设置了抗浮桩，浮力已由抗浮桩承担了，因此计算水池底板内力分也不需要重复考虑浮力的作用",{"key":19,"text":20,"correct":21},"C","水池底板内力验算的最不利工况是放水检修的时候",false,{"key":23,"text":24,"correct":21},"D","对水池基础进行地基承载力验算时，最不利的荷载条件是水池蓄满水","AB","验算底板内力时需考虑净反力，而净反力与浮力有关，不论是否设置抗浮板，内力验算均需考虑浮力；对底板内力而言，放水检修时（无水）内力最大，对地基承载力而言，蓄满水时对地基压力最大。",{"id":6,"name":28,"category":29,"favorite":30},"岩土专业知识","建筑工程",0]